CFM/CMM Thermo Anemometer

Similar documents
USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

User's Manual. CFM/CMM Thermo Anemometer 94204

True RMS AC/DC Mini Clamp Meter

INSTRUCTION MANUAL DAFM2

WQ Series Water Quality Bench top Meters

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

User s Manual. Model Digital Sound Level Meter

BASIC PH METER BASIC PH METER KIT

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

LCD Thermometer / Clock S No. 1253

Users Manual. Stroboscope. September 2014

Entry Level Speed/Depth Display. English Français Deutsch Nederlands Espagñol Italiano

Certificate of Calibration

Snap ShotTM User Manual

Operating Instructions

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Check our knowledge base at

Video Door Entry System Kits 2 Wires Installation

Operating Instructions & Parts Manual. Laser Distance Measure. Model No. 38YG99

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

Multi-function Portable. HD LCD Monitor. User Manual

MODE MENU /F1 /F2 F3 F4 PLCMHD80

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

User Manual Power and Harmonics Analyzer Model PQ3350

Operating Instructions & Parts Manual. Laser Distance Measure. Model No. 38YG98

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Operating Instructions Digital Color Monitor

Owners SW-LCD 2.0 Manual & Specifications

User Manual. Digital Stroboscope Tachometer. Model and Model

Manual. Simrad IS80 Wind Instrument WI80. English

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

APOLO DC B Electric Thermal Radiators

DisplayPort Signal Booster - DP Extender - 4K 60Hz

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Large Display ORP Pen

KING-METER USER GUIDE SW-LCD

Instruction Manual. Electronic Level - Inclinometer Model No

P XGA TFT Monitor. User s Manual

DIGISAT MULTI USER MANUAL

Quick-disconnect cables. Adjustable mounting brackets

BUREAU OF ENERGY EFFICIENCY

INSTRUCTION & INSTALLATION GUIDE

QUAD Camera Inputs with 8 display options (see pg 14-17) Handbook & Instructions. ...and more!

DCL9AW. User Manual. English

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

USER MANUEL. SNIPE 2 Ref R13

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Quick-disconnect cables. Adjustable mounting brackets

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

TR-2 OPERATION MANUAL

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

Cronotermostato Digitale

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

QUICK SETUP GUIDE. English 65T810UAD. Contents

VGA to HDMI Scaler x1200

SCALE & WEIGHT DISPLAYS

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Instruction Manual

LITTLE SMART. learning center USER'S MANUAL LIT T L E S M A R T. VTECH Printed in China

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Tablet Oscilloscope Quick Guide

User Manual. Power and Harmonics Analyzer Model PQ3350

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Dynatel Advanced Cable Locator 2250

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Intra-oral X-ray unit with high frequency DC generator. Product Data

INFORMATION TO THE USER

Manual. Simrad IS80 Heading Repeater HR80. English

9070 Smart Vibration Meter Instruction Manual

Programmable Room Thermostat With RF

Hybrid Chart Recorder 250 mm (10")

TOUCH PANEL SPECIFICATION

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Marshall. M-CT5 Camera-Top Monitor Owner s Manual M-CT5. Camera-Top Monitor. Owner s Manual

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

Ezecal MK3 User Manual

FAULT MAPPER PRO GRAPHICAL TDR CA7027. User Manual

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Ethernet to VGA over IP Converter

Omni Ultimate Quick Start Guide. 120V AC or 230V AC.

Microwave Counter, Power Meter and DVM in One Portable Package


Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer

How to use this Manual

28 II Ex Digital Multimeter

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

The Bloomberg 15-inch Compact Display Terminal Technical Information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Transcription:

USER MANUAL CFM/CMM Thermo Anemometer Model AN510 Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech AN510 CFM/CMM Thermo-Anemometer. This instrument measures Air Velocity, Air Flow (volume), Air Temperature, and Type K Temperature (external probe). The backlit LCD includes primary and secondary displays plus numerous status indicators. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version and translations of this User Manual, Product Updates, and Customer Support. Features Built-in microprocessor circuit Low-friction ball bearing mounted wheel provides high accuracy LCD with backlight for easy viewing Compact, light-weight, easy to use design Wristlet for easy one-handed operation Safety Please read the entire User Manual and Quick Start before operating this device. Use the meter only as specified and do not attempt to service or open the meter housing. Do not allow children to handle the meter. Please dispose of batteries and meter responsibly and in accordance with all applicable laws and regulations. 2

Meter Description 1. Air Velocity vane 2. Type K Temperature probe input 3. LCD Display 4. ON/OFF Power button 5. Backlight and button 6. MODE button 7. Unit Button 8. SET and button 9. RECORD button 10. Hold Button LCD Description 1. Air Velocity 2. Record 3. Max 4. Min 5. Hold 6. Air Flow 7. Battery Indicator 8. Auto Power OFF 9. Unit of Measure 10. Temperature Units 11. Lower LCD Display 12. Upper LCD Display 13. Type K Temperature 3

Operation Power Short press the power button to power the meter ON or OFF. The meter will begin displaying readings for the mode selected. If the LCD does not switch on, check the batteries located in the rear battery compartment. Backlight The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. Press the backlight button to turn the backlight on. The backlight will automatically turn off after 10 seconds. Data Hold Short press the H (hold) button to freeze or unfreeze a reading on the display. The H icon and the most recent reading will appear in the display. Hold function will not work while in record mode. Auto Power OFF (APO) In order to conserve battery life, the meter will automatically shut off after approximately 10 minutes of inactivity. The APO icon appears in the display when APO is programmed to be ON (see the SET function section later in this manual). Mode Press the mode M button to select the mode of operation. Each press of the button will step through the three modes. 1. Air Velocity Displays the air speed through the vane in the units selected. The AIR icon will appear in the display. Air velocity will be displayed on the upper part of the LCD. Air temperature will be displayed on the lower part of the LCD while in air velocity mode. 2. Air Flow Displays the volume of air passing through a duct. The Flow icon will appear in the display. The duct area must be entered using the SET function for proper measurements. 3. Type K Temperature Displays the temperature. The K icon will appear in the display. A type K thermocouple must be connected to the meter for Type K temperature displays. Air Velocity Units 1. Select Air Velocity with the M button. 2. Press the UNIT button to step through and select the desired units. (ft/min, m/s, km/h, MPH, knots) 4

SET Function (APO On/Off, Temperature Units and Air Flow Units Settings) 1. Press and Hold the button for 2 seconds. The yes or no APO display will appear: 2. Press the or button to turn the APO ON (YES) or OFF (NO). 3. Press the R button to save the selection. 4. The temperature units display will appear: 5. Press the or button to change the degree F or degree C units. 6. Press the R button to save the selection. 7. The Air Flow units display will appear: 8. Press the or button to select CMM or CFM units. 9. Press the R button to save the selection. 10. Short press the power button or wait approximately 10 seconds for the meter to return to normal operation. Setting Dimensions for Airflow Measurements The area of the air duct in square feet or square meters must be entered to perform air flow (volume) measurements. Remember to convert square inches or centimeters to square feet or square meters for area measurements before continuing. See Useful equations and Conversions later in this manual for additional information. 1. Select Air Flow with the M button. 2. Press the SET button. F-2 (ft 2 ) or m-2 (m 2 ) will appear in the display depending on the air flow units selected (CFM or CMM). 3. Press the or button to set the area in square feet or square meters in the display. 4. Press the R button to save the value. 5. With the area values programmed, measure air flow in the duct to obtain air volume (CFM or CMM) readings. 5

MAX-MIN Recording In this mode, the meter records the maximum and minimum values over time. 1. Short press the R button to enter the Record mode. The record icon will appear on the display. The maximum and minimum values will be recorded and updated during the measurement period. 2. Short press the R button to stop the Max-Min recording. The icon and the MAX value that occurred during the recording period will be displayed. 3. Short press the R button to display the icon along with the MIN value that occurred during the recording period. 4. Short press the H button to clear the memory and start a new max/min measurement period. 5. Long press the R button to exit record mode. Maintenance Battery Replacement 1. Power OFF the meter. 2. Remove the flat head screw that secures the battery compartment at the back of the meter. 3. Open the battery compartment and replace the 3 AAA batteries observing correct polarity. Re-assemble the meter before use Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. 6

Specifications General Display Backlit LCD 35 x 30mm (1.38 X 1.18 ) Sensor Measurements Tripod mount Operating Humidity Operating Temperature Air velocity: Low friction ball bearing; Air Temperature: thermistor Air Velocity, Air Temperature, Air Flow, Type K thermometer On back of meter 80% RH Max Over Limit Display - - - - Power Supply Power Consumption Weight 0 to 50 C (32 to 122 F) 3 x 1.5V AAA batteries Approximately 5mA DC 136g (4.8 oz.) Dimensions (HxWxD) 141x 57x 25mm (5.5 x 2.3 x 1.1 ) Air Velocity Units Range Resolution Accuracy ft/min 80 to 3937 1 m/s 0.4 to 20.0 0.1 km/h 1.4 to72.0 0.1 MPH 0.9 to 44.7 0.1 knots 0.8 to 38.8 0.1 ±3% F.S. C 0 to 50 0.1 ±1.2 C F 32 to 122 0.1 ±2.5 F Air Flow CMM (m 3 ) 0.024 to 36000 0.001/0.01/0.1/1 CFM (ft 3 ) 0.847 to 1271300 Type K Thermometer C -50 to 1300-50.1 to -100 F -58 to 2372-58.1 to -148 0.001/0.01/0.1/1/10 (x10) / 100 (x100) 0.1 0.1 ±(0.4% + 0.5 C) ±(0.4% + 1 C) ±(0.4% + 1 F) ±(0.4% + 1.8 F) 7

Useful Equations and Conversions AREA equation for rectangular or square ducts Width (W) Height (H) Area (A) = Width (W) x Height (H) Area equation for circular ducts Radius Area (A) = π x r 2 Where π = 3.14 and r 2 = radius x radius Cubic equations CFM (ft 3 /min) = Air Velocity (ft/min) x Area (ft 2 ) CMM (m 3 /min) = Air Velocity (m/sec) x Area (m 2 ) x 60 NOTE: Measurements made in inches must be converted to feet or meters before using the above formulae. Unit of Measure Conversion Table m/s ft/min knots km/h MPH 1 m/s 1 196.87 1.944 3.6 2.24 1 ft/min 0.00508 1 0.00987 0.01829 0.01138 1 knot 0.5144 101.27 1 1.8519 1.1523 1 km/h 0.2778 54.69 0.54 1 0.6222 1 MPH 0.4464 87.89 0.8679 1.6071 1 Copyright 2017 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified www.extech.com 8