Environmental Technology, Inc.

Similar documents
Modular Lube Lubrication Systems System Controls

Signet 2250 Hydrostatic Level Sensor

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

3 Cold Shrink Products

SQM40/41 Actuators for air and gas dampers

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

4 Wiring Brochure Wiring and installation of specific control

446PR / 446PRI IRRIGATION CONTROLLER

3M Better Buried Closures

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Solid-State Digital Timer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Cylindrical Photoelectric Sensor CY-100 SERIES

3M Better Buried Compound Compression Closure System

ANI-5.1CH HDMI 2CH/5.1CH Audio Extractor

Instruction Manual Model BlockUpconverter

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Single Point Flow Monitor SW118 SW119

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

1:4 VGA Hub EXT-VGA-144 USER S MANUAL.

Site Installation Model MP-8433

Site Installation Model MP-8424

Warner Photoscanner MCS-500 Series LED Photoelectric Control

476PR / 476PRI IRRIGATION CONTROLLER

Absolute Rotary Encoder E6CP

Revision 1.0 Parts List Minor

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

CONTRACTORS SPECIFICATION

Model Number Structure

PRE-INSTALLATION ELECTRICAL POWER GUIDE

Instruction Manual Model # Block Upconverter

lumenalpha spot Specification Sheet

LED Driver Linear / area fixed output

Junior Max (JR Max ) Controller

TV55. Owner s Manual. Indoor/Outdoor Amplified TV Antenna

Linear flow controls VFC Linear flow controls with actuator IFC

Disclaimer. Trademarks. Copyright. Contact Us Control4 Corporation S. Election Road Salt Lake City, UT USA

MAXX BOX. MX102/202 Series. MAXX Box

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Revision 3.0 Parts List Salvador 1~, 3~

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

NEA WIRING CENTRE NEA HT 230V /24 V

02/11/2015

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

User s Manual Model WF100 Extension Cable for EXA100

Sensor technologies Proximity sensors Series ST4. Brochure

Revision 1.0 Parts List Salvador 1~, 3~

5530M and 5530MHV Adaptatone Installation Sheet

Ordering details. Approval. Classification

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Benchmark and Benchmark Platinum Electrical Power Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Inductive sensor BI1.5-EG08K-Y1

2178-L/S Series Fiber Optic Splice Case with Gasket

AGS Low profile capacitive air gap measuring sensor for rotating machines

User Manual. Model 979T and 979R Digital Audio Converters

IGNITION TRANSFORMER FOR BURNERS

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Solenoid valves VZWD, directly actuated

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

Revision 2.0 Parts List Minette 1~, 3~

Datasheet - SRB301LC 24VAC/DC

Trusted 40 Channel 120 Vac Digital Input FTA

Magnecraft Power Relays

Trusted 40 Channel 120 Vac Digital Input FTA

LED Driver Compact fixed output

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Model /29S RF Splitter

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Specification for F Connector, Male, Pin Type

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

INSTALLATION INSTRUCTIONS

Revision 2.0 Parts List Minor

Installation Manual SaVi Note Underwater LED Light

T10 Float Level Switch

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Inductive sensor NI10-M18-Y1X-H1141

LED Driver Compact fixed output

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Linear flow control with actuator IFC

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

User Manual. Model 1351 DVI Repeater with HDCP

Henkel Installation Handbook LINEGUARD 2001

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Transcription:

Models LCD 1H and LCD 3H Snow Switch Installation and Operation Manual We manage heat Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239 FAX (574) 233-2152 or (888) 234 4238 www.networketi.com

Copyright 1995, 2000, 2008 Environmental Technology, Inc. DISCLAIMER Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the products that it describes, and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Environmental Technology, Inc. reserves the right to revise this publication and to make changes and improvements to the products described in this publication without the obligation of Environmental Technology, Inc. to notify any person or organization of such revisions, changes or improvements. The ETI logo, Snow Switch, We Pro vide Managed Heat, We Manage Heat and LCD are reg is tered trademarks of En vi ron men tal Technology, Inc. Copyright 2008 Environmental Technology, Inc. All rights reserved. All rights reserved. No part of this manual may be reproduced or translated in any form or by any means, electronic or mechanical including photocopying and recording, for any purpose without the express written consent of Environmental Technology, Inc. Printed in USA PN 17820 rev A 05/08

LCD-1H/LCD-3H Sensor Specifi cations Specifi cations: Part Number: Designation: Dimension: Weight: Construction: Mounting method: Mounting location: Storage temperature: Operating temperature: Power Requirements: Power Consumption: Sensing temperature: Precipitation signal: Contact rating: Hold-on Time: LCD-1H, LCD-3H 16793, 19435 LCD 1H Snow Switch and LCD 3H Snow Switch 3.5" x 3.5" x 3.25" (8.9cm x 8.9cm x 8.3cm) 13 oz (369gm) Molded plastic and epoxy resin, both U-V stable Attaches to standard 1/2" NPT male thread (ANSI 16mm) Outdoors, exposed to ambient temperature and precipitation -65 C to 85 C (-54 F to 185 F) -30 C to 60 C (-22 F to 140 F) 24 VAC (+/- 10%), 60 Hz 2.5W maximum p/n 16793 & P/N 19435 3.3 C to -30 C (38 F to -22 F) Contact closure 3 amps. resistive Approximately 5 hours for LCD-1H. (p/n 16793) Approximately 1 hour for LCD-3H. (p/n 19435) 1.

The Model LCD 1H/LCD-3H Snow Switch detects the presence of moisture at temperatures below 38 F. (3.3 C.), providing an output relay contact closure. The Model LCD-1H keeps the relay contacts closed for a fixed hold-on time of 5 hours after the heated moisture sensing grid is dried; the hold-on time for the Model LCD-3H is 1 hour. Installation Install in accordance with the requirements of all applicable electrical and building codes and regulations. 1. Determine the best location for the LCD 1H/LCD-3H Snow Switch. It must be located above a roof line or away from a building and subject to direct precipitation. AVOID overhead trees, shrubs, wires, eaves, canopies, etc. AVOID locations subject to falling/blowing debris or potential vandalism. AVOID exposure to artificial heat sources. 2. Mount the LCD 1H/LCD-3H Snow Switch securely in an upright position, as shown in the figure. A ½" (16mm) NPT opening is provided on the underside of the housing for rigid conduit entry. 3. Thread the four pigtail conductors through the conduit to the selected splicing en clo sure. 4. Hand tighten the conduit until snug. Caution: Over-tightening may damage the housing. 5. Plumb and level the sensor housing. 6. Ensure that all conduit terminations are watertight. 7. Splice and insulate pigtail conductors to customer-supplied extension conductors. Refer to table for wire colors. 2.

Windshield with water drain slots 12 Max (304.8 mm) Ambient air temperature sensor 1/2" (16 mm) rigid conduit for mounting (customer supplied) Weatherproof box or conduit body (customer supplied) Refer to table for wire colors Wire nuts (customer supplied) 24 VAC NEC Class 2 power source Maximum sensor power consumption: 2.5 W Precipitation: Normally Open Contact 3 Amps. Resistive 1 Amp. Inductive Wire color AWG Nominal length* Description Black 18 20 (508mm) 24 VAC supply White 18 20 (508mm) 24 VAC supply Yellow 18 20 (508mm) Normally open isolated contact * Nominal Length Of Wire Is From Base Of Sensor. 3.

Wiring Diagrams 24 Vac, 50/60 Hz Unswitched Supply LCD 1H LCD 3H Solenoid Valve Figure 1: Zone Solenoid Valve 24Vac, 50/60 Hz Unswitched Supply LCD 1H LCD 3H K OL (if required) 120Vac N Figure 2: Circulating Pump L

24Vac, 50/60 Hz Unswitched Supply LCD 1H LCD 3H CR Figure 3: Control Relay 24Vac, 50/60 Hz Unswitched Supply LCD 1H LCD 3H NEC Class 2 Circuit Figure 4: NEC Class 2 Circuit 4.

QUESTIONS AND COMMENTS For technical help, questions or comments concerning this product or any of Environmental Technology, Inc. products contact the Customer Service Department between 8:00am and 5:00pm EST at: Voice: Fax: E-mail: 800.234.4239 (USA and Canada) 574.233.1202 (elsewhere) 888.234.4238 (USA and Canada) 574.233.2152 (elsewhere) helpdesk@networketi.com Environmental Technology, Inc. 1850 N Sheridan Street, South Bend, IN 46628 The ETI logo, Snow Switch, We Pro vide Managed Heat, We Manage Heat and LCD are reg is tered trademarks of En vi ron men tal Technology, Inc. Copyright 2008 Environmental Technology, Inc. All rights reserved. PN 17820 rev A 05/08