Always one idea more flexible: häwa Thermal Components

Similar documents
Features. Specifications. Finish. Notes

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Roof-mounted Blue e+ cooling unit Integration solution VX25

GENESIS Indoor Air Conditioners

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ

GENESIS Indoor Air Conditioners

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories

Safe Enclosure Cooling

Air Conditioning Components and Equipments for Enclosures

Küba comfort DP. Draught-free ventilation and extremely quiet operation

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

WCHE BTU/Hr Watts

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Panel-mounting thermostats, type series EM

T BTU/Hr Watts

M BTU/Hr Watts. Finish. Options

COMPACT CATALOGUE. Thermal Management Signaling Technology Process Cooling Service EDITION 20.1

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

T BTU/Hr Watts

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

T BTU/Hr Watts

WCHE BTU/Hr Watts

MHB BTU/Hr Watt

XR47-24 Models 24 W/ F (43 W/ C)

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Flexibility and Safety. BERNSTEIN safety hinge switches

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8

Series CT7N Bimetallic Overload Relays

Immersion Pumps HCT (High Chem) sealless

WCHE BTU/Hr Watts

Climate Solutions Handbook

AC diagonal module Ø 200 mm

Model KBF 115 Constant climate chambers with large temperature / humidity range

Panel-Mounted Thermostat

XR47-24 Models 24 W/ F (43 W/ C)

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

Systems and components for industrial enclosures. Edition 2018/1

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions


AS09..S 3-pole Contactors - Spring Terminals

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Model KT 53 Cooling incubators with thermoelectric cooling

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

02/11/2015

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Split System Air Conditioner

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Product Data Sheet 8506 VW-691

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Product Data Sheet 4656 EZ

DIGITUS WALL MOUNT ENCLOSURE

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Linear flow control with actuator IFC

LED MODULES READYLINE DL

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

ULTRALOW TEMPERATURE FREEZERS -86 C

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

Bimetal Temperature Switch

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

10 PDUs 19 PDUs Zero-U PDUs

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Process transmitter RMA422

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

COMBINATION UNITS MARCH 2018

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Product Data Sheet 4656 ZW

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Panel-mounting Thermostats EM Series

Mechanical flow switch for On/Off control

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Linear flow controls VFC Linear flow controls with actuator IFC

Gear Pump Units For single-line centralized lubrication systems

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

XR47-24 Models 24 W/ F (43 W/ C)

Photoelectrics Through-beam Type PA18C.T..., DC

Transcription:

Always one idea more flexible: häwa Thermal Components

02 Thermal components

Does the häwa thermal components program offer an economical solution that meets all or most of our requirements? The best solutions to cabinet climate control problems are not produced on the assembly line, but by discussing them with you. Joachim Pfeiffer, Head of the Rhein-Main branch As your personal häwa adviser, I'm always there for you and look forward to helping you with your individual requirements. 03

Reg.-Nr.: Q-00008-16-2-1 This certifcate is valid through: 2019-10-25 On behalf of TÜg Certification body Dipl.-Ing. Martin Lindenberg Date of Issue: 2016-10-20 TÜg-GmbH, Basler Str. 115a, 79115 Freiburg Thermal components Our customers have special requirements for thermal components. Sometimes demanding, sometimes less so but their requirements are certainly always different. At häwa, these individual requirements are at the heart of our customer service. Because we are convinced that this is the only way to find the best solution for your particular application. CERTIFICATE The organisation häwa GmbH häwa Fertigungs GmbH Industriestraße 12 88489 Wain / Germany with the facilities Bad Wörishofen, Crimmitschau, Duisburg and Maintal has been audited and has proven that the quality management system complies with ISO 9001:2015 This certificate is valid for the following areas: Developments, Manufacturing and Distribution of Cabinets, Enclosures and Accessories Technische Überwachungsgemeinschaft TÜg GmbH www.tueg-gmbh.de All our häwa custom solutions are based on our thermal components, which have proven their worth countless times. With its convincing design and functionality, its solidity and reliability, even under extreme ambient conditions, our standard thermal program already offers numerous fields of application thanks to a wealth of features, different sizes, UL approval and comprehensive accessories. On this basis and benefiting from our long-standing experience derived from numerous projects, together with you we will be able to find the perfect solution for your requirements. This may be a simple adaption for better space utilization or an optimized valveation system for your technical application up to a complete customized development of a cooling or heating system. From varying dimensions to individual material requests we at häwa make almost anything possible for you.. We at häwa make almost anything possible for you. 04

Content Heaters page 06 Filter fans page 12 Heat exchangers page 28 Air-to-air heat exchangers page 30 Air-to-water heat exchangers page 34 Air conditioners page 38 Accessories page 44 05

Thermal components häwa Heaters Our selection of heating units for cabinets will also meet your requirements. Your häwa customer standard You require other materials, different dimensions or a special configuration? We at häwa do not call this a special solution but simply customer standard. Please contact us. info@haewa.de 1 1 Flexible: The snap-on attachment provided on many housings enables the mounting of the heaters individually inside the cabinet onto the existing DIN rails. 2 Safe: The compact plastic housing ensures direct protection against accidental contact with the heating element. Some units include an integrated thermostat or hygrostat. This means, the future use of the device (heating or dehumidifying) can already be preselected. 2 3 3 Versatile: The design features of all heaters include internal temperature limitation. The program includes various small accessories such as small thermostat, hygrostat and switch modules to allow adequate execution of each individual application. 4 Approvals: CE, VDE and UL (individually listed for the different versions) 06 www.haewa.de

Heaters Examples of application: The use of cabinet heaters counteracts possible functional malfunctions due to condensation or frost. Integrated fans in the cabinet heaters ensure a better distribution of the warm air. For larger cabinets, an even heat distribution is achieved through several smaller cabinet heaters. www.haewa.de 07

Thermal components häwa Heaters Small dimensions Maintenance of minimum temperatures Avoidance of condensation Advantages of units with PTC technology: Dynamic heating, temperature limitation large voltage range 100 mm 128 mm Advantages heater fan: Small, compact design, low noise level 165 mm A häwa adviser tip: Heater fans intended to heat the air can be used as freeze protection or to prevent formation of condensation inside the cabinet. Use the HTB program or simply ask your häwa adviser for layout and dimensioning. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ heizungen.html 08 www.haewa.de

Heaters Product Description Cabinet heaters are used for warming up the air inside a control cabinet. Low ambient temperatures and high humidity can cause condensation, which can endanger the functional safety of electric and electronic components. häwa offers a whole range of cabinet heaters from 10 to 1200 W to keep the cabinet temperature at the desired level. häwa solutions also include monitoring equipment e.g. to maintain minimum temperatures and for freeze protection. Convection heaters The design of the heater supports the natural convection ensuring a very good warm air flow The plastic housing is designed so as to keep the surface temperature at the accessible sides down Heating element: PTC thermistor, temperature-limiting The heaters are designed for permanent operation Quick mounting: snap-on attachment to 35 mm DIN rail Heater fans Heater fans to provide an evenly distributed air temperature inside control cabinets and enclosures with electric/electronic components Connection through internal terminal connector Partly adjustable integrated thermostat or hygrostat, maintenance-free Its small size makes the heater fan ideal for use in densely packed cabinets where space is at a premium Dynamic heating up through PTC technology (thermistor, temperature-limiting), high-performance cartridge for HG1200 Axial fan with ball bearing providing forced air circulation in the cabinet Control indicator for HGH350/550: glow lamp Easy snap-on attachment; screw fastening M5/M6 for HG950/1200 Scope of delivery 1 heater Note Operating PTC heaters below AC/DC 140 V will reduce the heater output by approx. 10 %. The heater output specified relates to an ambient temperature of 20 C (68 F). A safety clearance of 50 to 100 mm between adjacent components must be maintained (see relevant operating instructions). Technical data Frequency: AC 50/60 Hz Protection type: IP20 Protection class: II (double insulation) Operating/storage temperature: -45 to +70 C (-49 to +158 F) Operating/storage humidity: max. 90 % relative humidity (non-condensing) Surface temperature at 20 C (68 F) ambient temperature (except upper grid) CS/CSK < 80/85 C; (185 F) HG150/250 < 90 C; (194 F) HG400 < 65 C; (149 F) HGH350/550 < 65 C; (149 F) HG950 < 90 C; (194 F) HG1200 < 120 C; (248 F) Air outlet temperature: see applicable operating instructions Air flow, free circulation, for heater fans: HG150: 13.8 m³/h, HG250/400: 45 m³/h (AC230V), 54 m³/h (AC120V); HGH350/550: 35/45 m³/h, HG950/1200: 160 m³/h Connection: 2-pin 2.5 mm² terminal connector, max. tightening torque 0.8 Nm (HG250/400/950/1200 with strain relief) Installation position: direction of air flow vertical (air outlet at top) Attachment: clip for snap-on attachment to 35 mm DIN rail EN 60715, for HG950/1200 screw fastening M5/M6 at the bottom of the housing Approvals: see table Surface finish: housing: plastic, black UL94 V-0, HG350/550: light grey Accessories Small thermostats Temperature controller page 44 ff Mechanical humidity controller Electronic hygrotherm ETF012 Fixed-temperature thermostat FTO, contact breaker Schaltmodul SM010 www.haewa.de 09

Thermal components Small Solid State Heater CSC with PTC Thermistor Heater capacity Nominal voltage Type Control Start-up current/ preliminary fuse Approvals Abmessung (BxHxT) Order number mm 10 W 120-240 V AC (min. 110, max. 265 V) CSK - 1.0 A / 2 A (slow-blow) UL, CE 38 x 98 x 75 3185-0010-02-00 10 W 24 V DC CSK - 6 A / 6.3 A (slow-blow) CE 38 x 98 x 75 3185-0010-02-24 20 W 120-240 V AC (min. 110, max. 265 V) CSK - 2.5 A / 4 A (slow-blow) UL, CE 38 x 98 x 75 3185-0020-02-00 20 W 24 V DC CSK - 8 A / 6.3 A (slow-blow) CE 38 x 98 x 75 3185-0020-02-24 Small Solid State Heater CS/CSF with PTC Thermistor Heater capacity Nominal voltage Type Control Start-up current/ preliminary fuse Approvals Abmessung (BxHxT) Order number C* mm 50 W 120-240 V AC (min. 110, max. 265 V) CS 50-2.5 A / 4 A (slow-blow) UL, CE 60 x 110 x 90 3186-0050-02-00 50 W 24 V DC CS 50-11 A / 10 A (slow-blow) CE 60 x 110 x 90 3186-0050-02-24 100 W 120-240 V AC (min. 110, max. 265 V) CS 100-4.5 A / 8 A (slow-blow) UL, CE 60 x 110 x 90 3186-0100-02-00 100 W 24 V DC CS 100-13 A / 10 A (slow-blow) CE 60 x 110 x 90 3186-0100-02-24 150 W 120-240 V AC (min. 110, max. 265 V) CS 150-8 A / 10 A (slow-blow) UL, CE 60 x 110 x 90 3186-0150-02-00 150 W 24 V DC CS 150-16 A / 10 A (slow-blow) CE 60 x 150 x 90 3186-0150-02-24 100 W 120-240 V AC (min. 110, max. 265 V) CSF 100 Ein + 5 C Aus + 15 C 4.5 A / 8 A (slow-blow) UL, CE 60 x 133 x 90 3186-0100-03-00 * Toleranz ± 5 K 10 www.haewa.de

Heaters Small Heater Fan HG150/250/400 with PTC Thermistor Heater capacity Nominal voltage Type Control Start-up current/ preliminary fuse Approvals Abmessung (BxHxT) Order number mm 150 W 230 V AC HG 150-150 W 120 V AC HG 150-250 W 230 V AC HG 250-250 W 120 V AC HG 250-400 W 230 V AC HG 400-400 W 120 V AC HG 400-12 A / 10 A (slow-blow) 6 A / 10 A (slow-blow) 9 A / 10 A (slow-blow) 6 A / 10 A (slow-blow) 15 A / 10 A (slow-blow) 9 A / 10 A (slow-blow) UL, CE 65 x 75 x 87 3184-0150-02-23 UL, CE 65 x 75 x 87 3184-0150-02-12 UL, CE 85 x 90 x 111 3184-0250-02-23 UL, CE 85 x 90 x 111 3184-0250-02-12 UL, CE 85 x 90 x 111 3184-0400-02-23 UL, CE 85 x 90 x 111 3184-0400-02-12 Heater Fan HGH350/HGH550 with PTC Thermistor Heater Start-up current/ Abmessung Nominal voltage Type Control Approvals capacity preliminary fuse (BxHxT) * ** mm Order number 400 W 550 W 115 V AC / 50 Hz 115 V AC / 60 Hz HGH 350 Thermostat 0 to +60 C 14 A / 10 A (slow-blow) UL, CE 100 x 165 x 128 3184-0350-01-15 475 W 550 W 230 V AC / 50 Hz 230 V AC / 60 Hz HGH 350 Thermostat 0 to +60 C 11 A / 10 A (slow-blow) UL, CE 100 x 165 x 128 3184-0350-02-30 510 W 650 W 115 V AC / 50 Hz 115 V AC / 60 Hz HGH 550 Thermostat 0 to +60 C 15 A / 10 A (slow-blow) UL, CE 100 x 165 x 128 3184-0550-01-15 550 W 650 W 230 V AC / 50 Hz 230 V AC / 60 Hz HGH 550 Thermostat 0 to +60 C 13 A / 10 A (slow-blow) UL, CE 100 x 165 x 128 3184-0550-02-30 * bei + 20 C ** Schalttemperaturdifferenz 7 K (± 4 K Toleranz) Heater Fan HG950 with High-Performance Cartridge/HG1200 with PTC Thermistor Heater capacity Nominal voltage Type Control Start-up current/ preliminary fuse Approvals Abmessung (BxHxT) Order number mm 950 W 230 V AC HG 950 Thermostat 0 to + 60 C - / 6.3 A (slow-blow) UL, CE 145 x 100 x 168 3184-0950-02-23 950 W 230 V AC HG 950 Hygrostat 65% r.f. - / 6.3 A (slow-blow) UL, CE 145 x 100 x 168 3184-0950-03-23 1200 W 230 V AC HG 1200 Thermostat 0 to + 60 C 13 A / 10 A (slow-blow) UL, CE 145 x 120 x 168 3184-1200-02-23 www.haewa.de 11

Thermal components häwa Filter fans häwa fan filters come in different designs and airflow capacities. The well-conceived program permits tool-free mounting into the enclosure. Your häwa customer standard You require other materials, different dimensions or a special configuration? We at häwa do not call this a special solution but simply customer standard. Please contact us. info@haewa.de 1 2 3 1 Easy-to-install: Quick and tool-free mounting into enclosure/cabinet Snap-on mounting for secure hold due to integrated V2A springs Filtermatte Luftaustritt 3 Well-conceived: Maximum air flow with very compact filter design due to slanted filter pad positioning 2 Functional: A coding nose prevents incorrect installation of the front grid No additional screw fastening required 12 www.haewa.de

Filter Fans die Einzelheiten finden Sie beim Produkt Stainless steel or sheet steel you have the choice Stainless steel Stainless steel, material no. 1.4301 Brushed outer surface Sheet steel With improved pre-treatment through iron phosphating and chromium-free passivation Structured powder-coating Plastic PC ABS Available in various colors www.haewa.de 13

Thermal components häwa Fix Filter Fan Flat design, extending max. 6 mm 122 mm - 318 mm Snap-on mounting for secure hold 65 mm - 146 mm No additional screw fastening required 122 mm - 318 mm Alternatively in RAL 7030 for high demands Air flow 11-540 m³/h A häwa adviser tip: Filter fans are the easiest and most cost-efficient way of dissipating heat from enclosures and cabinets. Your häwa adviser will be happy to answer any question you might have. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ filterluefter.html 14 www.haewa.de

Filter Fans Product Description Filtering principle: suction When used without an exhaust filter, the ambient air is drawn in from the outside, filtered and then blown into the interior of the cabinet. Thus, a static overpressure of about 30 to 325 Pascal develops inside the closed cabinet, which means that dust particles cannot leak into the inside of the cabinet. Filtering principle: suction and discharge If an exhaust filter is installed in the upper part of the cabinet in addition to the filter fan, forced air valveation is obtained. The ambient air is drawn in at the lower part of the cabinet, filtered and blown into the interior of the cabinet. The through-flowing air takes up the heat generated by the cabinet's components and discharges it through the exhaust filter in the upper cabinet part. Protection type IP44 through standard foamed sealing. IP54 can be achieved by using filter pad G4. 2 auxiliary grooves facilitate the removal of the front grid for filter replacement A coding nose prevents incorrect installation of the front grid Snap-on mounting for secure hold due to integrated V2A springs No additional screw fastening required Scope of delivery 1 Fix filter fan or exhaust filter Technical data Frequency: 50/60 Hz Protection type: IP44; with filter pad G4: IP54 type 12 (type 3R optional) Temperature range: -10 to +55 C (+14 to +131 F) Air flow with filter pad G3/G4: see table Motor connection: terminal strip / blade terminal 2.8x0.5 / braids 300 mm, see table Approvals: CE, CURus Material: plastic housing: PC/ABS, self-extinguishing UL94 V-0 Surface finish: RAL 7030 stone grey or RAL 7035 Accessories Small thermostats Temperature controller Motor power cord Replacement filter pads page 44 ff Type 3R protective cover (for outdoor application) Filter pad G3 Note The air flow rates specified relate to filter fans and exhaust filters of same size and same filter pad G3 Other motor connections available upon request. www.haewa.de 15

Thermal components Fix Filter Fan Air flow Cutout Type Color Nominal Power Motor Dimension voltage consumption connection (WxHxD) Order number with Filter mm RAL mm G3: 14/16 m 3 /h 12 W / 50 Hz 92 x 92 7030 230 V AC G4: 11/13 m 3 /h 11 W / 60 Hz Braids 122 x 122 x 65 3159-9092-23-00-01* G3: 14/16 m 3 /h 12 W / 50 Hz 92 x 92 7035 230 V AC G4: 11/13 m 3 /h 11 W / 60 Hz Braids 122 x 122 x 65 3159-9092-23-70-01* G3: 14/16 m 3 /h 12 W / 50 Hz 92 x 92 7030 115 V AC Braids 122 x 122 x 65 3159-9092-11-00-01* G4: 11/13 m 3 /h 11 W / 60 Hz FL0 G3: 14/16 m 3 /h 12 W / 50 Hz 92 x 92 7035 115 V AC Braids 122 x 122 x 65 3159-9092-11-70-01* G4: 11/13 m 3 /h 11 W / 60 Hz G3: 14/16 m 3 /h G4: 11/13 m 3 /h 92 x 92 7030 24 V DC 2,3 W Braids 122 x 122 x 65 3159-9092-24-00-01* G3: 14/16 m 3 /h G4: 11/13 m 3 /h 92 x 92 7035 24 V DC 2,3 W Braids 122 x 122 x 65 3159-9092-24-70-01* G3: 40/43 m 3 /h 20 W / 50 Hz Blade 125 x 125 7030 230 V AC G4: 26/30 m 3 /h 20 W / 60 Hz terminal 154 x 154 x 66 3159-9128-23-01-01 G3: 40/43 m 3 /h 20 W / 50 Hz Blade 125 x 125 7035 230 V AC G4: 26/30 m 3 /h 20 W / 60 Hz terminal 154 x 154 x 66 3159-9128-23-71-01 G3: 40/43 m 3 /h 20 W / 50 Hz Blade 125 x 125 7030 115 V AC 154 x 154 x 66 3159-9128-11-01-01 G4: 26/30 m 3 /h 20 W / 60 Hz terminal FL1 G3: 40/43 m 3 /h 20 W / 50 Hz Blade 125 x 125 7035 115 V AC 154 x 154 x 66 3159-9128-11-71-01 G4: 26/30 m 3 /h 20 W / 60 Hz terminal G3: 40/43 m 3 /h G4: 26/30 m 3 /h 125 x 125 7030 24 V DC 7,4 W Braids 154 x 154 x 66 3159-9128-24-01-01 G3: 40/43 m 3 /h G4: 26/30 m 3 /h 125 x 125 7035 24 V DC 7,4 W Braids 154 x 154 x 66 3159-9128-24-71-01 G3: 112/125 m 3 /h 18 W / 50 Hz 224 x 224 7030 230 V AC G4: 88/93 m 3 /h 17 W / 60 Hz Terminals 250 x 250 x 105 3159-9223-23-02-01 G3: 112/125 m 3 /h 18 W / 50 Hz 224 x 224 7035 230 V AC G4: 88/93 m 3 /h 17 W / 60 Hz Terminals 250 x 250 x 105 3159-9223-23-72-01 G3: 112/125 m 3 /h 18 W / 50 Hz 224 x 224 7030 115 V AC Terminals 250 x 250 x 105 3159-9223-11-02-01 G4: 88/93 m 3 /h 17 W / 60 Hz FL2A G3: 112/125 m 3 /h 18 W / 50 Hz 224 x 224 7035 115 V AC Terminals 250 x 250 x 105 3159-9223-11-72-01 G4: 88/93 m 3 /h 17 W / 60 Hz G3: 112/125 m 3 /h G4: 88/93 m 3 /h 224 x 224 7030 24 V DC 7,4 W Braids 250 x 250 x 105 3159-9223-24-02 G3: 112/125 m 3 /h G4: 88/93 m 3 /h 224 x 224 7035 24 V DC 7,4 W Braids 250 x 250 x 105 3159-9223-24-72 G3: 180/220 m 3 /h 45 W / 50 Hz 224 x 224 7030 230 V AC G4: 130/162 m 3 /h 39 W / 60 Hz Terminal strip 250 x 250 x 122 3159-9224-23-02-02 G3: 180/220 m 3 /h 45 W / 50 Hz 224 x 224 7035 230 V AC G4: 130/162 m 3 /h 39 W / 60 Hz Terminal strip 250 x 250 x 122 3159-9224-23-72-02 G3: 180/220 m 3 /h 27 W / 50 Hz 224 x 224 7030 115 V AC Braids 250 x 250 x 105 3159-9224-11-02-01 G4: 130/162 m 3 /h 28 W / 60 Hz FL2B G3: 180/220 m 3 /h 27 W / 50 Hz 224 x 224 7035 115 V AC Braids 250 x 250 x 105 3159-9224-11-72-01 G4: 130/162 m 3 /h 28 W / 60 Hz G3: 180/220 m 3 /h G4: 130/162 m 3 /h 224 x 224 7030 24 V DC 13 W Braids 250 x 250 x 105 3159-9224-24-02 G3: 180/220 m 3 /h G4: 130/162 m 3 /h 224 x 224 7035 24 V DC 13 W Braids 250 x 250 x 105 3159-9224-24-72 G3: 320/350 m 3 /h 292 x 292 G4: 280/310 m 3 /h G3: 320/350 m 3 /h G4: 280/310 m 3 /h 7030 230 V AC FL3A 292 x 292 7035 230 V AC 64 W / 50 Hz 80 W / 60 Hz Terminal strip 318 x 318 x 146 3159-9291-23-03 64 W / 50 Hz 80 W / 60 Hz Terminal strip 318 x 318 x 146 3159-9291-23-73 16 www.haewa.de

Filter Fans Air flow Cutout Type Color Nominal Power Motor Dimension voltage consumption connection (WxHxD) Order number mit Filter mm RAL mm G3: 320/350 m 3 /h 64 W / 50 Hz Terminal 292 x 292 7030 115 V AC G4: 280/310 m 3 /h 80 W / 60 Hz strip 318 x 318 x 146 3159-9291-11-03 G3: 320/350 m 3 /h G4: 280/310 m 3 /h G3: 320/350 m 3 /h G4: 280/310 m 3 /h 64 W / 50 Hz 292 x 292 7035 115 V AC 80 W / 60 Hz FL3A 292 x 292 7030 24 V DC 55 W Terminal strip Terminal strip 318 x 318 x 146 3159-9291-11-73 318 x 318 x 146 3159-0291-24-03** G3: 320/350 m 3 /h G4: 280/310 m 3 /h 292 x 292 7035 24 V DC 55 W Terminal strip 318 x 318 x 146 3159-0291-24-73** G3: 480/540 m 3 /h G4: 440/500 m 3 /h 292 x 292 7030 230 V AC 67 W / 50 Hz 95 W / 60 Hz Terminal strip 318 x 318 x 146 3159-9292-23-03 G3: 480/540 m 3 /h G4: 440/500 m 3 /h 292 x 292 7035 230 V AC 67 W / 50 Hz 95 W / 60 Hz Terminal strip 318 x 318 x 146 3159-9292-23-73 G3: 480/540 m 3 /h G4: 440/500 m 3 /h G3: 480/540 m 3 /h G4: 440/500 m 3 /h 292 x 292 7030 115 V AC FL3B 292 x 292 7035 115 V AC 67 W / 50 Hz 95 W / 60 Hz 67 W / 50 Hz 95 W / 60 Hz Terminal strip Terminal strip 318 x 318 x 146 3159-9292-11-03 318 x 318 x 146 3159-9292-11-73 G3: 480/540 m 3 /h G4: 440/500 m 3 /h 292 x 292 7030 400 V AC 60 W / 50 Hz 80 W / 60 Hz Terminal strip 318 x 318 x 146 3159-0292-40-03** G3: 480/540 m 3 /h G4: 440/500 m 3 /h 292 x 292 7035 400 V AC 60 W / 50 Hz 80 W / 60 Hz Terminal strip 318 x 318 x 146 3159-0292-40-73** * with GL-Approvals ** without UL-Approvals Exhaust Filter for Fix Filter Fan suitable for type Cutout Type Color Order number RAL FL0 92 x 92 AF0 7030 3159-9092-00-00-01* FL0 92 x 92 AF0 7035 3159-9092-00-70-01* FL1 125 x 125 AF1 7030 3159-9128-00-01-01 FL1 125 x 125 AF1 7035 3159-9128-00-71-01 FL2A / FL2B 224 x 224 AF2 7030 3159-9224-00-02 FL2A / FL2B 224 x 224 AF2 7035 3159-9224-00-72 FL3A / FL3B 292 x 292 AF3 7030 3159-9292-00-03 FL3A / FL3B 292 x 292 AF3 7035 3159-9292-00-73 * with GL-Approvals www.haewa.de 17

Thermal components häwa Super Flat Filter Fans Super flat design, front grid extends only 5 mm Front grid removable without tools 144 mm - 324 mm Snap-on mounting with secure hold Air flow: 58 495 m³/h 144 mm - 324 mm 75 mm - 132 mm A häwa adviser tip: The wealth of the häwa world - ready for download. Simply convenient: Just go to our download center where all brochures, catalogs and technical drawings are available at a click. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ filterluefter.html 18 www.haewa.de

Filter Fans Product Description The front grid can easily be over-painted to match the color of your unit. Large front grid cut-outs ensuring maximum air flow, low noise level and easy visual inspection of filter pollution The filter is designed to easily allow size variations providing a cost-efficient solution to the specific requirements of your application Environmentally-friendly as all parts are made of galvanized sheet steel permitting easy recycling Snap-on attachment with coding noses integrated in the components Optional fastening with tapping screws Technical data Frequency: 50/60 Hz Protection type: IP42 Temperature range: -10 to +55 C (+14 to +131 F) Air flow with filter pad G3: see table Motor connection: terminal strip / blade terminal 2.8x0.5 see table Approvals: CE, CURus Material of housing: 1 mm sheet steel Surface finish: housing: sendzimir galvanized; front grid: powder-coated RAL 7035, slightly structured All interior components are made of galvanized sheet steel with contact brackets and integrated wire grid providing a high degree of EMI/RFI-shielding Accessories Small thermostats page 44 ff Scope of delivery 1 Stück superflache Filterlüfter oder Austrittsfilter Filtermatte G3 Temperature controller Motor power cord Replacement filter pads G3 Note Air flow rates specified relate to filter fans and exhaust filters of the same size and the same filter pad G3 Other motor connections available upon request Attention: Version 0324 is designed for screw attachment. No contact brackets and no wire grid Super Flat Filter Fan Air flow Cutout Type Color Nominal Power consumption connection (WxHxD) Motor Dimension voltage Order number Order number with Filter mm RAL mm Filter fan Exhaust Filter G3: 58 m 3 /h 122 x 122 0144 7035 230 V AC 15 W / 50 Hz Blade 14 W / 60 Hz terminal 144 x 144 x 75 3149-0144-23-07-01* 3149-0144-00-07* G3: 58 m 3 /h 122 x 122 0144 7035 115 V AC 15 W / 50 Hz Blade 14 W / 60 Hz terminal 144 x 144 x 75 3149-0144-11-07-01* 3149-0144-00-07* G3: 60 m 3 /h 138 x 138 0160 7035 230 V AC 15 W / 50 Hz Blade 14 W / 60 Hz terminal 160 x 160 x 75 3149-0160-23-07-01 3149-0160-00-07 G3: 60 m 3 /h 138 x 138 0160 7035 115 V AC 15 W / 50 Hz Blade 14 W / 60 Hz terminal 160 x 160 x 75 3149-0160-11-07-01 3149-0160-00-07 G3: 495 m 3 /h 292 x 292 0324 7035 230 V AC 64 W / 50 Hz 80 W / 60 Hz Terminals 324 x 324 x 132 3149-0324-23-07 3149-0324-00-07 G3: 495 m 3 /h 292 x 292 0324 7035 115 V AC 64 W / 50 Hz 80 W / 60 Hz Terminals 324 x 324 x 132 3149-0324-11-07 3149-0324-00-07 * with GL-Approvals www.haewa.de 19

Thermal components häwa Filter Fan IP 55 Splash-Proof 148 mm - 276 mm Protection type IP55 Maximum air flow capacity with very compact de sign due to slanted filter pad positioning Air flow 41 155 m³/h 160 mm - 292 mm 40 mm - 60 mm A häwa adviser tip: You will find technical drawings of this and other filter fans on our website. Also, your häwa adviser will be happy to answer all additional questions that you might have. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ filterluefter.html 20 www.haewa.de

Filter Fans Product Description Protective cover made of powder-coated sheet steel or alternatively brushed stainless steel. For roof-mounting: protection type IP52. Flexible air discharge either towards the front, the sides or the rear Scope of delivery Filterlüfter 1 fan, 1 protection grill, protective cover for filter with foamed sealing, filter pad G4, fastening screws Scope of delivery Eintrittsfilter Filterhaube mit aufgeschäumter Dichtung, Filtermatte G4, Befestigungsschrauben Technical data Frequency: 50/60 Hz Protection type: IP55, protective cover type 12 Temperature range: -10 to +55 C (+14 to +131 F) Air flow with filter pad G4: see table Motor connection: terminal strip / blade terminal 2.8x0.5 / braids 300 mm, see table Approvals: CE, curus Material of housing: 1 mm sheet steel or stainless steel Surface finish of housing: powder-coated RAL 7035, slightly structured or brushed Note The air flow rates specified relate to filter fans and inlet filters of the same size and the same filter pad G4 Other motor connections available upon request Accessories Small thermostats page 44 ff Temperature controller Motor power cord Replacement filter pads G4 www.haewa.de 21

Thermal components Filter Fan IP55 Splash-Proof Power Nominal Motoranschluss (WxHxD) Dimension Air flow Material Type Color consumption voltage with Filter RAL mm A/I* G3: 50 m 3 /h G4: 41 m 3 /h Order number Sheet steel 0148 7035 15 W / 50 Hz 3142-0148-02-27-01** 230 V AC 15 W / 60 Hz Blade terminal 148 x 160 x 40/43 Stainless steel 0148 3142-0148-02-25-01** G3: 50 m 3 /h G4: 41 m 3 /h G3: 50 m 3 /h G4: 41 m 3 /h G3: 90 m 3 /h G4: 75 m 3 /h G3: 155 m 3 /h G4: 142 m 3 /h G3: 90 m 3 /h G4: 75 m 3 /h G3: 155 m 3 /h G4: 142 m 3 /h G3: 90 m 3 /h G4: 75 m 3 /h G3: 155 m 3 /h G4: 142 m 3 /h Sheet steel 0148 7035 15 W / 50 Hz 3142-0148-01-17-01** 115 V AC 15 W / 60 Hz Blade terminal 148 x 160 x 40/43 Stainless steel 0148 3142-0148-01-15-01** Sheet steel 0148 7035 3142-0148-00-24** 24 V DC 7,44 W Braids 148 x 160 x 40/43 Stainless steel 0148 3142-0148-00-25** Sheet steel 0276 7035 15 W / 50 Hz 3142-0276-02-27-01 230 V AC Blade terminal 276 x 292 x 50/43 15 W / 60 Hz Stainless steel 0276 3142-0276-02-25-01 Sheet steel 1276 7035 45 W / 50 Hz 3142-1276-02-27-02 230 V AC 39 W / 60 Hz Terminal strip 276 x 292 x 50/60 Stainless steel 1276 3142-1276-02-25-02 Sheet steel 0276 7035 15 W / 50 Hz 3142-0276-01-17-01 115 V AC 15 W / 60 Hz Blade terminal 276 x 292 x 50/43 Stainless steel 0276 3142-0276-01-15-01 Sheet steel 1276 7035 29 W / 50 Hz 3142-1276-01-17-01 115 V AC 29 W / 60 Hz Braids 276 x 292 x 50/43 Stainless steel 1276 3142-1276-01-15-01 Sheet steel 0276 7035 3142-0276-00-24 24 V DC 7,44 W Braids 276 x 292 x 50/43 Stainless steel 0276 3142-0276-00-25 Sheet steel 1276 7035 3142-1276-00-24 24 V DC 12 W Braids 276 x 292 x 50/43 Stainless steel 1276 3142-1276-00-25 * A = External depth / I = Internal depth ** with GL-Approvals Inlet Filter for IP55 Splash-Proof suitable for type Material Dimension Order number mm Sheet steel 3142-0148-00-07* 0148 148 x 160 x 40 Stainless steel 3142-0148-00-05* 0276 / 1276 Sheet steel 3142-0276-00-07 276 x 292 x 50 Stainless steel 3142-0276-00-05 * GL approved 22 www.haewa.de

Filter Fans Fix filter fan: approved type 12 version approved type 3R version www.haewa.de 23

Thermal components häwa Roof-Mounted Valveator Air discharge to all four sides Space-saving 77 mm 330 mm 330 mm Air flow 290 m³/h A häwa adviser tip: The wealth of the häwa world - ready for download. Simply convenient: Just go to our download center where all brochures, catalogs and technical drawings are available at a click. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ filterluefter.html 24 www.haewa.de

Filter Fans Product Description For heat dissipation through the top of cabinets. Radial fan ensuring very high air flow Scope of delivery Roof-mounted valveator complete with fan and mounting hardware or roof cover without fan with mounting hardware Note As air inlet, we would recommend the installation of a filter, product code 3159-0292-00-73 with filter pad G3 at the bottom of the cabinet The air flow rates specified relate to the use of a size 3 inlet filter in conjunction with filter pad G3 Versions with special voltages available upon request Technical data Frequency: 50/60 Hz Protection type: IP43 Temperature range: -25 to +40 C (-13 to +104 F) Motor connection: plug connection Approvals fan motor: CE Material of housing: 1 mm sheet steel Surface finish of housing: powder-coated, RAL 7035, slightly structured Accessories Small thermostats Temperature controller page 44 ff Roof-Mounted Valveator Air flow Cutout Dimension Nominal (WxHxD) voltage mm mm 290 m 3 /h 249 x 249 330 x 330 x 77 230 V AC Power consumption 53 W / 50 Hz 51 W / 60 Hz Valveator Motorconnection Order number with fan Plug connection 3148-0300-02-27 290 m 3 /h 249 x 249 330 x 330 x 77 115 V AC 70 W / 60 Hz with fan Plug connection 3148-0300-01-17 - 249 x 249 330 x 330 x 77 - - without fan - 3148-0300-00-07 www.haewa.de 25

Thermal components häwa Interior Fan/ Built-in Fan 122 mm - 60 mm 80 mm - 119 mm Interior Fan Preventing hot spots Air flow 27 180 m³/h 38 mm 50 mm Built-in Fan 136 mm 60 mm A häwa adviser tip: You will find technical drawings of interior fans on our website. Also, your häwa adviser will be happy to answer all additional questions that you might have. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ filterluefter.html 26 www.haewa.de

Filter Fans Product Description Used for air circulation inside the cabinet and to avoid the buildup of heat at certain places in the cabinet. Scope of delivery Interior fan or built-in fan (complete with clip or screw fastening) Mounting hardware Technical data Frequency: 50/60 Hz Protection type: IP20 Temperature range: -10 to +70 C (+14 to +158 F) Motor connection interior fan: blade terminal 2.8x0.5 Motor connection built-in fan: 2-pin duo press terminal Note Versions with special voltages available upon request Accessories Small thermostats page 44 ff Temperature controller Interior fan Air flow unimpeded airflow 50 m 3 /h 61 m 3 /h Power consumption 12 W / 50 Hz 11 W / 60 Hz Mounting Type Screw fastening Nominal voltage 230 V AC Motor connection Blade terminal Approvals fan motor Dimension Order number (WxHxD) mm VDE, CSA, UL 80 x 122 x 38 3157-0088-02-20 160 m 3 /h 180 m 3 /h 19 W / 50 Hz 18 W / 60 Hz Screw fastening 230 V AC Blade terminal VDE, CSA, UL 119 x 161 x 38 3157-0119-02-20 Build-in fan Air flow freiblasend Power consumption Mounting Type Nominal voltage Motor connection Approvals fan motor Dimension (WxHxD) mm Order number 27,6 m 3 /h 4 W Clip fastening 100-240 V AC (min. 90, max. 265 V) 2-pin duo press terminal CE 50 x 60 x 136 3157-0050-11-23 27,6 m 3 /h 4 W Screw fastening 100-240 V AC (min. 90, max. 265 V) 2-pin duo press terminal CE 50 x 60 x 136 3157-0051-11-23 www.haewa.de 27

Thermal components häwa Heat Exchangers häwa heat exchangers come in different capacity versions. The wide range of our heat exchanger program provides virtually unlimited possibilities suitable also for your application. Your häwa customer standard You require other materials, different dimensions or a special configuration? We at häwa do not call this a special solution but simply customer standard. Please contact us. info@haewa.de 1 2 4 1 Comfortable: Due to the well-conceived design of the units, they are extremely lowmaintenance All parts are easily accessible 2 Easy to mount: Can be adapted to any connection condition by means of hose nozzles or threaded sleeves 3 Functional: Optional upgrading to stainless material for extreme requirements To be used also under rough ambient conditions such as dirty environments and oily or contaminated air 4 Stable: Carcass and cover are made of metal to make the housing torsion-resistant Easy and quick mounting via the existing fastening points 28 www.haewa.de

Wärmetauscher die Einzelheiten finden Sie beim Produkt Stainless steel or sheet steel you have the choice Stainless steel Stainless steel material no. 1.4301 Brushed outer surface Sheet steel Improved pre-treatment through iron phosphating and chromium-free passivation Powder-coated, structured www.haewa.de 29

Thermal components häwa Air-to-Air Heat Exchangers 150 mm - 445 mm Non-filter, low-maintenance Easy to service Compact design 130 mm - 1800 mm A häwa adviser tip: 65 mm - 145 mm Up to an ambient temperature of approx. 40 C (104 F), airto-air heat exchangers are the most economical solution for dust-free cooling of cabinets. Your häwa adviser will be happy to answer all questions that you might have. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ luft-luft-waermetauscher. html 30 www.haewa.de

Heat Exchangers Product Description häwa air-to-air heat exchangers with their highly conductive aluminum fin system have two separate IP54-sealed air circuits. This ensures that no air can penetrate from the outside into the cabinet. The fan of the internal circle draws hot air from the cabinet, blows it down along the heat exchanger where it is cooled by the cooling fins before it is forced back into the interior of the cabinet. For devices up to 1150 W, the heat is transmitted via thermal conduction through the continuous aluminum fins for devices of 2000 W or more through the channel walls to the external circuit. The fan of the external circuit draws in the cool ambient air, blows it through the fins, where the heat is absorbed by the air, which is then forced back outside. For external or internal cabinet mounting, roof-mounting or any other mounting position Installation inside cabinets requires a clean, dry environment (same drill pattern, however turned upside down, from the inside) Internal and external fans connected / controlled separately Easy cleaning of externally mounted heat exchanger core, applicable to units of 220 W to 1150 W Easy removal of heat exchanger core for thorough wet cleaning, applicable to all devices Technical data Frequency: 50/60 Hz Protection type: IP54, interior fan IP22/44 Ambient temperature: max. +75 C (+167 F) Dissipated heat at 25 K temperature difference: 150 3250 W Approval: CE Material of exchanger element: aluminum Material of housing/cover: 1 mm sheet steel Surface finish: powder-coated RAL 7035, slightly structured Accessories Small thermostats Temperature controller page 44 ff HTB thermo-calculation program Scope of delivery Heat exchanger with 2 power cords Seals Mounting hardware Note Special voltages or stainless steel housing available upon request www.haewa.de 31

Thermal components Air-to-Air Heat Exchangers, Internal or External Mounting Spec. thermal output Type Nominal voltage Power consumption Mounting type Dimension (WxHxD) Order number mm 6 W/K Kleinst-WT 230 V AC 2 x 14 W Partially internal 150 x 130 x 110 3114-0150-15-07 8,8 W/K Mini-Mini 220 230 V AC 2 x 14 W External/internal 160 x 325 x 120 3114-0220-16-07 14 W/K Superflach 350 230 V AC 2 x 14 W External/internal 250 x 510 x 65 3114-0350-25-07 20 W/K Kompakt 500 230 V AC 2 x 28 W External/internal 250 x 510 x 90 3114-0500-25-07 30 W/K Kompakt 750 230 V AC 2 x 80 W External/internal 316 x 780 x 90 3114-0750-31-07 46 W/K Standard 1150 230 V AC 2 x 80 W External/internal 250 x 1330 x 90 3114-1150-25-07 80 W/K SH2000 230 V AC 2 x 85 W External/internal 445 x 1330 x 100 3114-2000-23-07 130 W/K SH3250 230 V AC 2 x 155/210 W External/internal 390 x 1800 x 145 3114-3250-23-07 Air-to-Air Heat Exchanger, Roof-Moun Spec. thermal output Type Nominal voltage Power consumption Mounting type Dimension (WxHxD) Order number mm 64 W/K DW1600 230 V AC 2 x 85 W roof-mount 600 x 300 x 380 3115-1600-60-07 32 www.haewa.de

Heat Exchangers Custom Solutions Key features: Air outlet towards the top Design and drill pattern to allow optional mounting of heat exchanger or cooling unit Key properties: Can be used in dust-laden environment (heat exchanger preferable to filter fan) www.haewa.de 33

84 mm - 205 mm Thermal components häwa Air-to-Water Heat Exchangers 207 mm - 500 mm For connection to cold water supply Low-maintenance Very easy to service High cooling capacity 460 mm - 1200 mm A häwa adviser tip: häwa heat exchangers to be connected to cold water supply are a cost-efficient and environmentally friendly alternative to air cooling devices using refrigerants. They are particularly useful in applications where a reliable source of sufficiently cool water is available. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ luft-wasser-waermetauscher.html 34 www.haewa.de

Heat Exchangers Product Description These devices have been developed to cool the air inside control cabinets. Air-to-water heat exchangers are particularly suitable for use at high ambient temperatures. The air-to-water heat exchanger consists mainly of a housing, the heat exchanger core (tube bundle with fins), a fan and connection lines. The fan draws the hot air from the cabinet into the housing of the heat exchanger, where the air is cooled down via the core (using water as coolant) and blown back into the cabinet. Very flat design, min. 84 mm External mounting or as 19 slide-in module Available with or without valve Suitable for use even in most unfavorable environmental conditions such as high ambient temperatures and heavily polluted or aggressive air, provided cooling water is available Suitable for use at extremely high ambient temperatures of up to 75 C (167 F), as the temperature that can be reached inside the cabinet depends primarily on the water inlet temperature. Hence, it is possible to cool the air down to well below the ambient temperature. This means that air-to-water heat exchangers can also be used in environments where neither filter fans nor air-to-air heat exchangers or air conditioners can be used. Wearing parts such as fan and valve are easy to exchange Units with valve include a thermostat-controlled valve with interference suppressor to save water and avoid excessive under-cooling In the 19 type WE2800 version, the air is routed at the side, and in the WE2800 V version, the air is drawn in at the front In both 19 types, the thermostat has a separate cable fed through the rear panel. This allows measuring and controlling the temperature inside the cabinet at any point in the cabinet We recommend the use of our mechanical hygrostat, order number 3150-0030-02-30, to avoid condensation inside the cabinet which may occur when cooling below the cabinet's dew point. Scope of delivery Heat exchanger with power cord Seals Mounting hardware Thermostat with DIN rail (only for 19 slide-in devices) Note Versions with special voltages, other water connections mit Kompaktregler / Display, with continuously regulating valve, with stainless steel tubings or housings available upon request The WW3500 unit includes water connection fittings with 3/8 internal thread at the top and the bottom. The unused fitting must be closed. Technical data Frequency: 50/60 Hz Protection type: IP55; WE 2800 in connection with cabinet Ambient temperature: +75 C (+167 F) max. Suitable coolant: clean water Effective cooling capacity specified relates to an amount of water of 400 l/h Operating pressure: 10 bar max. For units with valve: factory setting of thermostat at +35 C (+95 F) Fitting for water connection: Ø 10 mm or 3/8 internal thread at the bottom of the device, for WW4000S on the left-hand side wall Condensation discharge nozzle: Ø 10 mm at the bottom of the device, for WW4000S on the left-hand side wall curus Approval File no. E163420 Material: exchanger element: copper/aluminum housing/cover: 1 mm sheet steel Surface finish: powder-coated RAL 7035, slightly structured Accessories Small thermostats Temperature controller Humidity controller page 44 ff. HTB thermo-calculation program www.haewa.de 35

Thermal components Air-to-Water Heat Exchanger for External Mounting Useful cooling capacity Type Nominal voltage Control Water connection Approvals Dimension (WxHxD) Order number L35 - W10 mm 800 W WW700 230 V AC Fitting Ø 10 mm CE/UL 207 x 460 x 84 3116-0700-22-07 800 W WW700 115 V AC Fitting Ø 10 mm CE/UL 207 x 460 x 84 3116-0700-11-07 800 W WW700 230 V AC Valve Fitting Ø 10 mm CE 207 x 510 x 84 3116-0700-23S03 1500 W WW1500 230 V AC Valve Fitting Ø 10 mm CE 316 x 780 x 84 3116-1500-22-07 2000 W WW2000 230 V AC Valve Fitting Ø 10 mm CE 380 x 1200 x 84 3116-2000-22-07 3500 W WW3500S 230 V AC 3/8" internal thread CE/UL 380 x 1200 x 205 3116-3500-22-07 3500 W WW3500S 115 V AC 3/8" internal thread CE/UL 380 x 1200 x 205 3116-3500-11-07 4300 W WW4000S 230 V AC Thermostat Fitting Ø 10 mm CE/UL 500 x 800 x 180 3116-4000-22S07 4300 W WW4000S 115 V AC Thermostat Fitting Ø 10 mm CE/UL 500 x 800 x 180 3116-4000-11S07 Slide-in 19 Air-to-Water Heat Exchanger Useful cooling capacity Type Nominal voltage Discharge Control Water connection Approvals Dimension (WxHxD) Order number L35 - W10 mm 2800 W WE2800V 230 V AC front Valve 3/8" internal thread CE 446 x 170 x 462 3117-2800-23-07 2800 W WE2800 230 V AC left Valve Fitting Ø 10 mm CE 435 x 170 x 460 3117-2800-22-07 36 www.haewa.de

Heat Exchangers Custom Solutions Key features: Inspection glass for fan monitoring Key features: Optimal outside dimensions for efficient air circulation Size and location of heat exchanger cores adapted to cabinet www.haewa.de 37

Thermal components häwa Air Conditioners häwa air conditioners come in a variety of designs. The wide range of our air conditioner program provides virtually unlimited possibilities. Your häwa customer standard You require other materials, different dimensions or a special configuration? We at häwa do not call this a special solution but simply customer standard. Please contact us. info@haewa.de 1 2 4 1 Comfortable: All non-filter units are easy to install or remove, no additional components required Low space requirements due to the typical well-conceived design 2 Easy to service: Exchanging the filter on the devices is easy to do Any maintenance works on häwa devices that might be required are easy and fast to perform 3 Stable: Carcass and cover are made of metal to make the housing very torsion-resistant and weather-proof 4 Innovative: Larger surface area despite more compact design 5 Energy-saving: Many units include condensed water evaporation without needing additional electric energy Easy selection of adequate control method 38 www.haewa.de

Air Conditioners die Einzelheiten finden Sie beim Produkt Stainless steel or sheet steel you have the choice. Stainless steel Stainless steel material no. 1.4301 Brushed outer surface Sheet steel Improved pre-treatment through iron phosphating and chromium-free passivation Powder-coated, structured www.haewa.de 39

Thermal components häwa Air Conditioners 270 mm - 600 mm Compact design High cooling capacity Protection type: IP54 Stable Stainless steel / sheet steel design Clever details Approvals: CE, curus, culu 420 mm - 1665 mm A häwa adviser tip: Our häwa thermo-calculation program HTB will help you to very easily find the right air conditioner for your cabinets. Your häwa adviser will be happy to personally answer all questions that you might have. http://www.haewa.de/ loesungen-produkte/thermokomponenten/thermokomponenten/gruppe/ kuehlgeraete.html 122 mm - 375 mm 40 www.haewa.de

Air Conditioners Product Description häwa air conditioners for control cabinets can be used as independent devices up to an ambient temperature of max. 50/55 C (122/131 F). They have two separate IP54-sealed air circuits, equipped with 1 fan each. Cooling or heat transfer from the inside of the cabinet to the outside takes place through active cooling (refrigerating unit). This allows to cool down the temperature in the cabinet below ambient temperature. haewa air conditioners operate with the CFC-free, ozone-friendly refrigerant R134a. With or without filter For external or external/internal mounting or roof-mounting The factory-set temperature inside the cabinet of +35 C (95 F) can be field-adjusted after removal of the cover panel or, for devices equipped with a display, from outside. A control line for the door switch, separately connected for units with a cooling capacity of 800 W or more, permits remote ON/OFF switching of the unit without power disconnect. General fault signal as potential-free changeover contact fed out in the control line. Free from silicone compounds, PCB, PCT, formaldehyde and cadmium Thermostat-control: A capillary thermostat controls the compressor and the external fan (for small air conditioners directly, for larger ones via a contactor). The switching hysteresis is ca. 6 Kelvin. Control electronics for standard controller KR-HS: control PCB with 1 temperature gauge integrated in the device Control electronics for display controller KR-HD: control PCB with 4 temperature gauges integrated in the device and KR-B control unit built into the front panel of the device. Compact controller EKC, EKC202C, AK or ECB: A compact controller built in at the front of the device controls the compressor and the external fan, the AK and the EKC202C also controls the interior fan via the door switch. Non-filter devices Low maintenance Any condensed water is evaporated in the outside circuit. In case of excessive condensation, e.g. due to doors that were left open or excessive humidity, excess condensation is drained off via a drain pipe through the slots provided in the bottom of the enclosure cover (for KF800 to KF2400), or directly by connecting a drain hose. For KF800 to KF2400, power connection is effected via plug-in terminal at the rear of the device. The mating connector is included in the scope of delivery. For KF400, the power cord is fed through the rear of the device. Units with filter For devices of 1000 W or more, the condensation is drained off directly via a discharge nozzle in the bottom panel. Power connection by means of a power cord (not included in the scope of delivery) fed through the entry plate at the rear of the device. Units with microchannel heat exchanger Devices with 1400 W or more with integrated condensation evaporator Power connection by means of a power cord (not included in the scope of delivery) fed through the entry plate at the rear of the device Ready to be installed. For external mounting onto a cabinet, a mounting frame is required With lint pad Technical data Frequency: 50/60 Hz Protection type: IP54, external fan IP44 Ambient temperature: see table Refrigerant: R134a Units with product code..u.. are curus File no. SA12365 approved Microchannel units are culus File no. SA12365 approved Material: sheet steel or stainless steel Surface finish: powder-coated RAL 7035, slightly structured or brushed stainless steel Scope of delivery Air conditioner, power cord, plug-in terminal or screw-type terminal, rubber seals, mounting hardware Note Power consumption and cooling capacity specifications relate to L35-L35 according to DIN 3168 and DIN EN 14511. Three-phase devices can also be operated with 460 V / 60 Hz Accessories Replacement filter pads etc. page 44 ff www.haewa.de 41

Thermal components Non-Filter Air Conditioners Useful cooling capacity L35 - L35 400 W 400 W Material Type Ambient Nominal Mounting Dimension Control temperature Order number voltage type (WxHxD) range mm Sheet steel KF400 3120-0400-23-07 230 V AC Thermostat 20 C / 50 C External/internal 275 x 525 x 144 Stainless steel KF400 3120-0400-23-02 Sheet steel KF400U 3120-0400-23U07 230 V AC Thermostat 20 C / 45 C External/internal 275 x 525 x 144 Stainless steel KF400U 3120-0400-23U02 780 W Sheet steel KF800RD 230 V AC Kompakt 20 C / 50 C External/internal 395 x 980 x 190 3120-0800-23-37 780 W Sheet steel KF800U 230 V AC Themostat 20 C / 45 C External/internal 395 x 980 x 190 3120-0800-23U07 1000 W Sheet steel KF1000RD 230 V AC Kompakt 20 C / 50 C External/internal 395 x 850 x 190 3120-1000-23-07 1.200 W Sheet steel KF1200RD 230 V AC Kompakt 20 C / 55 C External/internal 400 x 1450 x 140 3120-1200-23-37 1.600 W Sheet steel KF1600 230 V AC KR-HS +B* 20 C / 55 C External/internal 400 x 1450 x 162 3120-1600-23-37 1.600 W Sheet steel KF1600U 230 V AC KR-HS +B* 20 C / 40 C External/internal 400 x 1450 x 140 3120-1600-23U17 2.400 W Sheet steel KF2400RD 400 V AC Kompakt 20 C / 55 C External/internal 460 x 1500 x 233 3120-2400-40-07 * with control unit Air Conditioners with Filter Useful Ambient Nominal Mounting Dimension cooling Material Type Control temperature voltage type (WxHxD) capacity range Order number L35 - L35 mm 370 W Sheet steel K400F 230 V AC Thermostat 20 C / 50 C External/internal 270 x 520 x 122 3129-0400-23-07 370 W Sheet steel K400FQ 230 V AC Thermostat 20 C / 50 C External/internal 520 x 320 x 122 3129-0401-23-07 850 W Sheet steel K1000F-RD 230 V AC Kompakt 20 C / 55 C External 400 x 900 x 210 3127-1500-22-07 980 W Sheet steel K1000FD-RD 230 V AC Kompakt 20 C / 55 C External 400 x 950 x 205 3129-1000-23-37 1550 W Sheet steel K1500FD-RD Kompakt 3129-1500-23-37 230 V AC 20 C / 55 C External 400 x 1120 x 260 Stainless steel K1500FD-RD Kompakt 3129-1500-23-32 2600 W Sheet steel K2600FD-RD 400 V AC Kompakt 20 C / 55 C External 460 x 1500 x 260 3129-2600-40-37 42 www.haewa.de

Air Conditioners Air Conditioners with Filter, Roof-Mount Useful cooling capacity L35 - L35 1440 W Nominal Ambient temperature range Mounting Material Type Control voltage type Dimension Order number (WxHxD) mm Sheet steel KA1500F 230 V AC 3128-1500-22-17 Kompakt 20 C / 55 C roof-mount 600 x 420 x 375 Stainless steel KA1500F-RD 230 V AC 3128-1500-22-32 Air Conditioners UL-Listed with Microchannel Useful Nominal Ambient temperature range cooling Material Type Control voltage capacity L35 - L35 500 W Sheet steel K500FE 115 V AC Kompakt 20 C / 55 C 500 W Sheet steel K500FE 230 V AC Kompakt 20 C / 55 C 1000 W Sheet teel K1000FE 115 V AC Kompakt 20 C / 55 C 1000 W Sheet steel K1000FE 230 V AC Kompakt 20 C / 55 C 1400 W Sheet steel K1400FE 115 V AC Kompakt 20 C / 55 C 1400 W Sheet steel K1400FE 230 V AC Kompakt 20 C / 55 C 2000 W Sheet steel K2000FE 115 V AC Kompakt 20 C / 55 C 2000 W Sheet steel K2000FE 230 V AC Kompakt 20 C / 55 C 2000 W Sheet steel K2000FE 460 V AC** Kompakt 20 C / 55 C 3000 W Sheet steel K3000FE 460 V AC** Kompakt 20 C / 55 C Mounting type External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* External/ internal* Dimension (WxHxD) Order number mm 375 x 957 x 212 3122-0500-11-17 375 x 957 x 212 3122-0500-23-17 375 x 957 x 212 3122-1000-11-17 375 x 957 x 212 3122-1000-23-17 454 x 1665 x 197 3122-1400-11-17 454 x 1665 x 197 3122-1400-23-17 454 x 1665 x 197 3122-2000-11-17 454 x 1665 x 197 3122-2000-23-17 454 x 1665 x 197 3122-2000-46-17 496 x 1665 x 237 3122-3000-46-17 * Accessories required for external mounting ** Can be reconnected to 400 V on transformer Mounting Frame for Air Conditioners with Microchannel Material Type Mounting type Dimension ** (WxHxD) Order number mm Sheet steel K500FE External 375 x 957 x 196 3122-0957-37-19 Sheet steel K1000FE External 375 x 957 x 196 3122-0957-37-19 Sheet steel K1400FE External 454 x 1665 x 180 3122-1665-49-19 Sheet steel K2000FE External 454 x 1665 x 180 3122-1665-49-19 Sheet steel K3000FE External 496 x 1665 x 221 3122-1665-49-23 ** Mounting depth incl. cover plate of air conditioner www.haewa.de 43

Thermal components Accessories Thermal Components Below, you will find a list of the most important accessories for our häwa thermal components. Please visit our homepage for more detailed information and order numbers. Temperature Controller Used to control the temperature of heaters, filter fans, heat exchangers or for fault indication Humidity Controller Used to control the humidity of heaters or for fault indication Switch Module SM010 Electronic relay to switch DC devices, in particular DC heaters, high-performance. Thermostat and hygrostat can be connected via the separate input to actuate the electronic relay Operating voltage: DC24V (DC 20 28 V) Max. switching capacity: DC28V 16 A 44 www.haewa.de

Type 3R Protective Cover For Fix filter fans of the 3159 series Mounting without additional mounting bores with Fix filter fan or exhaust filter Maintenance Accessories Replacement filter pads to be exchanged against used-up / dirty filter pads of filter fans and air conditioners Mounting Accessories Mounting frame for external mounting of microchannel air conditioners Power Connection Accessories Motor connection cable for filter fan with blade terminal (fast-on) connection 2-pin version: with molded PVC plug, black, length = 1 m 3-pin version: cord set with fully insulated 2.8x0.5 fast-on plugs and grounding line with ring cable lug, length = 3 m HTB Thermo-Calculation Program The häwa calculation program is used to determine heat dissipation and to select the häwa thermal components for cabinet climate control www.haewa.de 45

cabinet system enclosures x-frame FIRE PROTECTION For each application as individual as your requirements the häwa product program häwa securely the best solution We are your reliable partner for wellconceived cabinet and enclosure systems, smart IT solutions, effective thermal components, modular machine racks, functional cable ducts and practical tools. In particular when individual and flexible solutions are needed. From the conceptual and structural design to manufacture and logistics including a fast delivery and maintenance service, we at häwa are your one-stop shop your personal häwa adviser will always be there to assist you. More than 400 committed staff members are available to find the best possible solution for your challenges and your budget. The result: high-quality products which meet or even exceed your expectations today and tomorrow. 46 www.haewa.de

häwa Produktportfolio Thermal Components Custom Construction Ducts, Accessories Tools Our way to develop unique solutions for you: Customer-oriented We listen to you, we make your issues part of our planning, we consult and assist you: In a nutshell, as your partner, we work closely together with you this is how we find solutions tailored to your needs. Personally We at häwa rely on personal contact your personal häwa adviser is always there for you, brings your ideas to life and is dedicated to accompanying you on your way to your optimal solution. Reliable Go for a trustworthy partner, on which you can rely in any situation especially when the safety of components is at stake, i.e. when functional reliability is key. Our motto at häwa is: We keep our promises. This is what it's all about. High-quality We at häwa have very high standards to provide excellent quality as proven by the DIN EN ISO 9001 2008 certification. The same applies to our consultancy and the service we provide. We do not rely on what we have already achieved we are always striving for more for your benefit. Thinking ahead We come up with surprising ideas tailored to your individual requirements and smart solutions that always meet or even exceed your expectations today and tomorrow. There is only one goal to pursue for us: Finding the best possible solution for your challenges. www.haewa.de 47