Development of 16-channels Compact EEG System Using Real-time High-speed Wireless Transmission

Similar documents
Real Time Bio-signal Acquisition System

Real-time EEG signal processing based on TI s TMS320C6713 DSK

A BCI Control System for TV Channels Selection

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

An Integrated EMG Data Acquisition System by Using Android app

IOT BASED ENERGY METER RATING

An Exploration of the OpenEEG Project

WEB SERVER NETWORK FOR ECG RECORDING AND BODY TEMPERATURE MONITORING SYSTEM BASED ON ARM MICROCONTROLLER

DESIGN AND DEVELOPMENT OF A MICROCONTROLLER BASED PORTABLE ECG MONITOR

C-MAX. CMM-9301-V3.1S Bluetooth 4.0 Single Mode HCI Module. Description. 1.1 Features

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Design and analysis of microcontroller system using AMBA- Lite bus

Why Use the Cypress PSoC?

Digital Strobe Tuner. w/ On stage Display

Design of Vision Embedded Platform with AVR

CoLinkEx JTAG/SWD adapter USER MANUAL

WEB BASED HEALTH RECORDING AND MONITORING SYSTEM USING ARM MICROCONTROLLER

RF4432F27 wireless transceiver module

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools

Automatic Projector Tilt Compensation System

ISSN (PRINT): , (ONLINE): , VOLUME-5, ISSUE-4,

Walter Graphtek's PL-EEG

Getting Started with Launchpad and Grove Starter Kit. Franklin Cooper University Marketing Manager

Senior Design Project A FEW PROJECT IDEAS

Design and Realization of the Guitar Tuner Using MyRIO

medlab One Channel ECG OEM Module EG 01000

TV Character Generator

Enhancing the TMS320C6713 DSK for DSP Education

Introduction to Digital Signal Processing (DSP)

Connecting To and Programming the LPC2148 Blue Board. Method 1 ISP (In-System Programming) w/ Flash Magic

Design of Electro Cardiograph Machine Based on ATmega Microcontroller

Brain-Computer Interface (BCI)

DSP in Communications and Signal Processing

EDUCATIONAL TUTOR FOR MENTALLY DISABLE STUDENTS

Low-Power Decimation Filter for 2.5 GHz Operation in Standard-Cell Implementation

Chapter 1. Introduction to Digital Signal Processing

Introduction to Data Conversion and Processing

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

A 5-Gb/s Half-rate Clock Recovery Circuit in 0.25-μm CMOS Technology

1 Feb Grading WB PM Low power Wireless RF Transmitter for Photodiode Temperature Measurements

RF4432 wireless transceiver module

User s Guide - 64 Bit Digital Electronic Crossover

A Guide to Selecting the Right EMG System

HEART ATTACK DETECTION BY HEARTBEAT SENSING USING INTERNET OF THINGS : IOT

VOB - data over Video Overlay Box

Distributed by Pycom Ltd. Copyright 2016 by Pycom Ltd. All rights reserved. No part of this document may be reproduced, distributed, or transmitted

Tutorial 11 ChipscopePro, ISE 10.1 and Xilinx Simulator on the Digilent Spartan-3E board

ProMOS. Bravo1601. Stand-alone BLE SMD Modules. Datasheet (V1.0) ProMOS Co., Ltd. IoT Solutions Provider.

LMH0340/LMH0341 SerDes EVK User Guide

ECE 4220 Real Time Embedded Systems Final Project Spectrum Analyzer

Prototype Model of Li-Fi Technology using Visible Light Communication

SMARTING SMART, RELIABLE, SIMPLE

System Quality Indicators

Sharif University of Technology. SoC: Introduction

HEALTH MONITORING SYSTEM USING IOT

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

SUBSYSTEMS FOR DATA ACQUISITION #39. Analog-to-Digital Converter (ADC) Function Card

EEG A1452 SCTE-104 Inserter Frame Card

Using SignalTap II in the Quartus II Software

Sensor Development for the imote2 Smart Sensor Platform

A Noble Identification System for Tumors and Implementation

RAPID SOC PROOF-OF-CONCEPT FOR ZERO COST JEFF MILLER, PRODUCT MARKETING AND STRATEGY, MENTOR GRAPHICS PHIL BURR, SENIOR PRODUCT MANAGER, ARM

RF (Wireless) Fundamentals 1- Day Seminar

Lab experience 1: Introduction to LabView

RF Solution for LED Display Screen

Datasheet. Dual-Band airmax ac Radio with Dedicated Wi-Fi Management. Model: B-DB-AC. airmax ac Technology for 300+ Mbps Throughput at 5 GHz

DMC550 Technical Reference

An Ultra-Low Power Physical Layer Design For Wireless Body Area Network

Development of an Analog ECG Simulator using Standalone Embedded System

Solutions to Embedded System Design Challenges Part II

Real-Time Compensation of Chatter Vibration in Machine Tools

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

Experiment # 4 Counters and Logic Analyzer

Smart Night Light. Figure 1: The state diagram for the FSM of the ALS.

TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS:

Advanced System LSIs for Home 3D Systems

Make technology more simple, Make life more intelligent. Firefly-RK3128. Product. Specifications. Version Date Updated content

Honeywell HomMed Wireless Scale Quick Reference Guide

Therefore, HDCVI is an optimal solution for megapixel high definition application, featuring non-latent long-distance transmission at lower cost.

VHDL Design and Implementation of FPGA Based Logic Analyzer: Work in Progress

INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET) APPLIANCE SWITCHING USING EYE MOVEMENT FOR PARALYZED PEOPLE

ECG Demonstration Board

MEE 1000A. Neuromaster MEE-1000A. Intra-Operative Monitoring System

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

Exhibits. Open House. NHK STRL Open House Entrance. Smart Production. Open House 2018 Exhibits

WizFi250 Datasheet. Introduction. Features. WizFi250 Datasheet v English. Datasheet History

FPGA-BASED EDUCATIONAL LAB PLATFORM

Monitor QA Management i model

Make technology more simple, Make life more intelligent. Firefly-PX3-SE. Product. Specifications. Version Date Updated content

Using an IEEE Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems. Zbigniew Czaja 1, Bogdan Bartosinski 2

A Low Power Delay Buffer Using Gated Driver Tree

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

Vision Standards Bring Sharper View to Medical Imaging

Input / Output to module

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

Welcome to Electrical and Electronic Engineering UCD. Electronic/Computer Engineering (ECE)

ADDRESSING THE CHALLENGES OF IOT DESIGN JEFF MILLER, PRODUCT MARKETING MANAGER, MENTOR GRAPHICS

High Performance TFT LCD Driver ICs for Large-Size Displays

Pattern Based Attendance System using RF module

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Transcription:

Engineering, 2013, 5, 93-97 doi:10.4236/eng.2013.55b019 Published Online May 2013 (http://www.scirp.org/journal/eng) Development of 16-channels Compact EEG System Using Real-time High-speed Wireless Transmission B. R. Myung 1, S. K. Yoo 2 1 Graduate Programs of Biomedical Engineering, Yonsei University, Seoul, Korea 2 Correspondence author, Department of medical Engineering, College of Medicine, Yonsei University, Seoul, Korea Email: jacob84@yonsei.ac.kr, sunkyoo@yuhs.ac Received 2013 ABSTRACT For the convenience of people with disability and for normal people, a demand for intelligent interfaces is ever increasing and therefore related studies are actively being conducted. Recently a study is being conducted to develop an interface through face expression, movement of the body and eye movements, and further more active attempts to use electrical signals(brainwave, electrocardiogram, electromyogram) measured from the human body is also actively being progressed. In addition, the development and the usage of mobile devices and smart devices are promoting these research activities even more. The brainwave is measured by electrical activities between nerve cells in the cerebral cortex using scalp electrodes. The brainwave is mainly used for diagnosis and treatment of diseases such as epilepsy, encephalitis, brain tumors and brain damage. As a result, the brainwave measurement methods and analytical methods were developed. Interface using the brainwave will not go through language or body behavior which is the result of the information processed by the brain but will pass directly to the system providing a brain-computer interface (BCI). This is possible because a variety of the brainwave appears depending on the human s physical and mental state. Using the brainwave with the intelligent brain-computer interface or combining it with mobile devices and smart devices, regardless of space constraints, the brainwave measurement should be possible.[4,7] In this study, in order to measure the brainwave without spatial constraint, 16 channel compact brainwave measurements system using a high-speed wireless communications were designed. It was designed with a 16 channel to classify the various brainwave patterns that appear and for estimating the location of the nerve cells that triggered the brainwave. And in order to transmit the brainwave data within the channel without loss, a high-speed wireless communication must be possible that can enable a high-speed wireless transmission more sufficient than the Bluetooth, therefore, 802.11 compliant Wi-Fi communication methods were used to transfer the data to the PC. In addition, by using an analog front-end IC having a single-chip configuration with real-time digital filters, the miniaturization of the system was implemented and in order to verify the system Eye-blocking was used to observe the changes in the EEG signal. Keywords: Electroencephalography; High-speed Wireless Transmission; Real-time 1. Introduction The brainwave(eeg: Electroencephalography) means the measurement of the displacement using the electrode that appears as a microscopic signal on the surface of the brain in forms of synthesized electrical signal which have occurred by the numerous nerve cells in the brain. The brainwave signal has temporal and spatial variation depending on the brain activity, condition of the body at the time of measurement and brain function. The measurement of the brainwave is essential for the diagnosis of brain function and dysfunction. Currently used mainly in hospitals and doctors will measure and analyze the brainwave for the diagnosis of diseases such as epilepsy and brain damage. In the recent years, research has been actively conducted in order to utilize the brainwave with the intelligent brain-computer interface (BCI) and human-computer interface (HCI). For each part of the cerebral cortex where most of the nerve cells exist, functions that appear physically and mentally are different and estimating the location of the activated nerve cells can be used in a variety of research. In the past, it was verified by opening the skull but currently a noninvasive method of medical equipments such as X-ray, CT and MRI is used. But MRI and CT cause a behavioral constraint to the patients when measuring because it requires over 30 minutes of measuring time and it is in adequate to measure in daily life. Whereas the brainwave measurement equipment can be manufactured inexpensively and by wearing the helmet with attached electrodes can lessen the constraints on behavior enabling a continuous health

94 B. R. MYUNG, S. K. YOO monitoring. EEG measurement system used for heath status monitoring systems such as BCI and HCI are to be used during a daily life therefore it should be simple to wear and provide maximum activity.[3,5,6,7] In this study, while ensuring the user s activity, a miniaturized 16-channel EEG system that uses Wi-Fi module for transferring the measured EEG data at high speed will be developed. This EEG system will be de- signed with 16 channels for estimating the location of the various brainwave pattern category and nerve cells and will be able to transmit measured brainwave data within the channel without loss using 802.11 compliant high speed Wi-Fi modules. Also it will be designed with an analog front-end IC having a single-chip configuration with digital filters to enable portability and wear. Also in this article, based on 10-20 system to reference A1 will verify the system by observing the changes in the EEG signal by attaching electrodes. 2. Materials EEG system which was developed in this study uses 802.11 compliant Wi-Fi modules for high speed wireless communications and was designed by using Analog front-end IC and digital filter for miniaturization. It is important for wireless EEG system for BCI and HCI health status monitoring to have low power consumption, so devices with low power consumption such as Wi-Fi module, A/D converter, memory, micro controller, Analog front-end IC that includes UART module which can operate under a low power was used.[6,7] The Figure 1 is a block diagram of the 16 channel EEG system. This system is configured with EEG measurement part (Analog front-end IC), microprocessor part and Wi-Fi module part. The electrodes that are attached to the user s head for EEG measurement will be disc electrodes which are attached to the area by paste. Signals received from the electrodes will be amplified through the Analog Frontend IC and converted to a digital signal through A/D converter which will be transferred to the micro processsor using the SPI communication. A signal processing will take place within the microprocessor with an incomeing signal through the digital filter. This signal through the UART communication will be transferred as Wi-Fi communication packets and the Wi-Fi module will use its wireless communication to transfer the data to the PC and the program will display the measured EEG signal from the user s head by channel. Transferring of data between the microcontroller and Wi-Fi module is made possible through UART communication and the transfer rate is 115,200 bps. Wi-Fi can have maximum transfer rate (802.11 b) of 11 Mbps. 16 channel EEG system has maximum power consumption of 80 ma, A/D s resolving ability of 24 bit and sampling frequency of 512 Hz.[4,5,7] 2.1. Analog front-end Analog Front-end IC used in this study is developed with 8 channel 24 bit dedicated for EEG/ECG which is integrated version of Analog Front-end product. It has power consumption of only 1mW per channel and can save up to 95% of power with high channel density and equipment portability which is very suitable IC for this study. The Figure 2 is an internal block diagram for Analog Front-end IC. Analog Front-end IC has 8 input channels. In this study, EEG is measured by arranging the electrodes in common reference method thus each input channel s negative input is binding with reference and EEG s GND channel is connected to the Right-Leg-Driven(RLD) circuit built in the Analog Front-end IC. EEG input signal measured through the electrodes will go through the internal amplifier within Analog Front-end IC to be amplified 12 times which then the signal will be transferred through the Delta-sigma A/D converter to the microprocessor through the built in SPI communications module. At such time, A/D converter s sampling frequency is 512 Hz. 2.2. Microprocessor The microprocessor uses SPI communications to control and receive data from the Analog Front-end IC and transfers the data through Wi-Fi module using UART communication. Figure 1. 16 channel EEG system block diagram. Figure 2. Analog front-end block diagram.

B. R. MYUNG, S. K. YOO 95 For the microprocessor, STM32F103 series of ST Microelectronics was used. STM32F103 series provides 16 MHz, 3.3 v with typical 25 ua current consumption which has low power characteristics and includes SPI and UART communications module and suitable to be utilized for this study. Also with JTAG emulation mode built in, without the need of surrounding circuits for the emulation, software upgrade and debugging is possible even with the chip mounted on the target board. The Figure 3 is a program flowchart for the KEIL uvision 4 compiler coded microprocessor. 2.3. Digital Filter Signal received through the SPI communication is stored in the internal buffer then through digital filter signal processing is performed. The brainwave has the frequency band of 0.1-100 Hz and the Table 1 shows each divided frequencies of the brainwave.[1] When measuring the EEG, in order to see the frequency band of preference, EEG system is equipped with Low Pass Filter (LPF), High Pass Filter (HPF) and Notch Filter. Using a program, filter setting value can be selected at the microprocessor.(table 2) Each filter is configured with 4th LPF, 2nd HPF, 6th Notch Filter and designed with the Direct Form-II IIR Filter.[2] 2.4. Wi-Fi Module Wi-Fi is grafting of a wireless technology onto a Hi-Fi, which is a wireless LAN technology enabling high performance communication. It uses the frequency band of 2.4 Ghz and using this technology, a notebook can be used around the house with a wireless connection. Also using this high speed technology, 5 PC s can be connected to share files, graphics, videos and audios. Wi-Fi can provide 11Mbps of speed and at optimal environment can be used anywhere in the radius of 500m. Wi-Fi module used in this study is WizFi210 by Wiznet. Wizfi210 is Serial to Wi-Fi product that can easily and rapidly change the previous serial application to Wi-Fi capable solution. WizFi210 provides the AT Command Set which allows all functions of the module to be selected using a serial interface. Therefore, not only the serial equipment but for microprocessor as well, Wi-Fi can be easily set-up using the UART. WizFi210 is 801.11b compliant and supports up to 11Mbps of speed during a wireless interface. Also uses low power wireless communications technology with an optimal hardware provides stability and also provides Serial to Wi-Fi solution with dramatically improved power consumption, therefore it is suitable for this study.[8] The Figure 4 is an internal block diagram of WizFi- 210. Wi-Fi module receives EEG data from the microprocessor and transfers the data to the PC through wireless communication. Wi-Fi module operates with the Limited AP Mode where the wireless communication was possible by connecting through the AP set by the Wi-Fi module using a PC. Wave Delta Theta Alpha Beta Gamma Figure 3. Micro processor flow chart. Table 1. EEG wave. Frequency band Below 4 Hz 4-7 Hz 8-13 Hz 14-30 Hz Over 30 Hz 2.5. PC EEG Viewer Program To check the changes in EEG signal measured from the EEG System developed through this study, PC Viewer Program was realized using the C# and this program was created by Visual Studio 2010. Filter High Pass Filter Low Pass Filter Notch Filter Table 2. EEG frequency setting value. Frequency value 0.159 Hz, 0.53 Hz, 1.09 Hz, 5.31 Hz 30 Hz, 50 Hz, 70 Hz, 100 Hz 60 Hz

96 B. R. MYUNG, S. K. YOO The Viewer program function receives the EEG data sent from the Wi-Fi module and displays the received signal by channel. After initiating this program, clicking the button on top left corner, Wi-Fi module and connection will be conducted and it will analyze the header and tail information of the transferred data packet to display the EEG signal by channel. Signals that are displayed can be stored for EEG signal analysis and the stored signals in file format can be analyzed by using the Tool. Also High Pass Filter, Low Pass Filter, Notch Filter and Gain can be adjusted to select the desired frequency band. The Figure 5 shows the EEG Viewer Program developed by this study. Similar to the Figure 6 above, using the EEG system with confirmed Sine Wave through the simulator, have measured the EEG by having a stable normal person with its eye open. A paste was attached to the area where the measurement of the Glass Corporation s Disc electrodes was necessary. International 10-20 system was based to attach the electrodes and the EEG was measured as seen in the Figure 7, Figure 8 and the measured signal is shown on the Figure 9. Then, the reference electrodes and the ground electrodes were attached to the A2.[7] 3. Methods The following is the 16 channel miniaturized EEG system developed by this study. Figure 6. 16 channels EEG system using Wi-Fi. Figure 4. Wizfi210 block diagram. Figure 7. International 10-20 System. Figure 5. PC Viewer program. Figure 8. Setup Electrode using EEG Cap.

B. R. MYUNG, S. K. YOO 97 at O 2 a signal was measured near the 13Hz and thus Alpha Wave measurement was checked.[2] Figure 9. Measurement EEG Signal. 4. Results In this study, 16 channel miniaturized EEG system using the Wi-Fi module s real-time high speed wireless communication was designed and produced. And using this system to measure the EEG we have conducted an Eye-blocking test. Measuring the brainwave to be used with BCI and HCI health monitoring, it was necessary to develop a system that is easy to wear having the mobility during a daily life. To achieve this, in this study, a wireless module was used to configure the system to reduce the activity constraint and also we have selected a single chip for configuration in order to miniaturize the system and to reduce power consumption controlling the single chip using a microprocessor. Also, using a high speed Wi-Fi module, a lot of data within the 16 channel was transferred without loss to the PC. 5. Acknowledgements This work was supported by the National Research Foundation of Korea(NRF) grant funded by the Korea government(mest) (No.2010-0026833) and supported by the Industrial Strategic Technology Development Program (10031977-2012-23) funded by the Ministry of Knowledge Economy (MKE, Korea) Figure 10. Stored EEG Data. Figure 11. Power Spectrum of EEG Signal. In order to analyze the signal by storing it as the data, the data was brought from the Complexity. Complexity is a program for analyzing the measured signal. Stored EEG data can be seen in the Figure 10. As in Figure 11, a power spectrum for the stored signal was checked. The Figure 11 is a measurement of EEG Signal(top) from Fz and EEG signal(bottom) from O2. Both graphs were measured with an eyes closed and REFERENCES [1] R. Cooper, J. W. Osselton and J. C. Shaw, EEG Technology- Third edition, Butterworths&Co Ltd, 1980 [2] L. Sornmo and P. Laguna, Bioelectrical Signal Processing in Cardiac and Neurological Applicaions, Elsevier academic press. [3] J. D. Bayliss, A Flexible Brain-Computer Interface, University of Rochester, 2001 [4] Gilsup Song, A Study Compact EEG Measurment System Development Using Bluetooth and EEG Pattern Classification, Chonnam national university, Gwangju, Korea. [5] L. Brown, J. van de Molengraft and C. Van Hoof, A Low-Power, Wireless, 8-Channel EEG Monitoring Headset, 32 nd Annual International Conference of the IEEE EMBS, 2010 [6] Ching-Sung Wang, Design of a 32-Channel EEG System for Brain Control Interface Applications, Journal of Biomedicine and Biotechnology, Vol. 2012, Article ID 274939, 2012. doi :10.1155/2012/274939 [7] M. Modarreszadeh and R. N. Schmidt, Wireless, 32-Channel, EEG and Epliepsy Monitoring System, Proceedings of 19 th International Conference, IEEE/EMBS 1997, Chicago, IL. USA. [8] Wiznet, WizFi210 User Manual V1.14, 2013, www.wiznet.co.kr.