Professional Media Server Quick Start Guide

Similar documents
ipump 622 Streaming Media Decoder Installation Quick Start Guide

ipump6400 Professional Media Server User s Manual

Correspondence regarding this publication, Revision A First Edition: November 2003

DTV742 Installation Quick Start Guide

DTV744 Installation Quick Start Guide

ipump 525 IP Media Player Quick Start Guide

ipump 562 Digital Media Server Quick Start Guide

DTV701 Broadcast Digital Television Processor. User's Reference Manual

Unity 552. Digital Media Receiver Installation Quick Start Guide

DTV742. 8VSB 4-Channel Multiplexer. User s Manual

Simple Media Platform Quick Installation Guide V1.0-N. Simple Media Platform. Quick Installation Guide

DTV735 Digital Television Processor Fox Version. User's Manual

For flexible advertisement insertion configurations, this receiver provides four types of outputs:

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

AMD-53-C TWIN MODULATOR / MULTIPLEXER AMD-53-C DVB-C MODULATOR / MULTIPLEXER INSTRUCTION MANUAL

Dell Wyse 5030 PCoIP Zero Client

Video Server SED-2100R/S. Quick Installation Guide

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

Installation Guide. Model DVR395/DVR396 DIGITAL VIDEO RECEIVER

Operation and Installation Guide

Instruction Manual Model Block Up/Downconverter

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Amb-OS Media, LLC AMR-100

MediaKind RX

UMH160 Integrated Digital Receiver Quick Installation Guide

Broadcast Satellite Modulator

V pro8 QUICK START GUIDE

FS3. Quick Start Guide. Overview. FS3 Control

Professional 4-Channel DVB Receiver and Transmodulator Item: 5213

MyM-3S Micro Master. Installation Guide. English. design for TV

DCD-24 Word Clock Distributor

CompactMax-2 DVB-S/S2 TO DVB-T2 TRANSMODULATOR - 0 MI2100 -

Installation & Operational Manual

DSR-7400 Series. Commercial Integrated Satellite Receiver/Transcoder. Highlights. Product Overview

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

UPCOM UC-250L L-BAND DVB MODULATOR

MyM Pro 3S/6S Installation guide

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

X-Band Redundant LNB Systems

MyM Pro T2 Installation guide

EEG A1452 SCTE-104 Inserter Frame Card

CRT1041M-C-02 CRT1041M-C-02 DATASHEET DATASHEET. 4-channel DVB-C modulator

1/3 RACK-MOUNTED BLOCK CONVERTERS

Operation and Installation Guide

Ku-Band Redundant LNB Systems

Distribute 2x FULL-HD Video to All TV over Coax

MediaKind RX8200 SkyUK CA

Disclaimer. Warning and Caution CAUTION!

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Cisco D9859 Advanced Receiver Transcoder

C-Band Redundant LNB Systems

7881IRDA Series QUICK START GUIDE

The VeCOAX PRO2 HD SDI is The #1 Best HD Quality & Price solution to distribute HD SDI video signals to

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

EtherneTV-STB Set Top Box

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

ipump 562 Digital Media Server User s Manual

CompactMax-4 DVB-S/S2 TO ISDB-T TRANSMODULATOR - 0 MI2101 -

WNE CLIENT V.4.2 EMR CONFIGURATION GUIDE SEPTEMBER 30, 2010

Cisco D9859 Advanced Receiver Transcoder

Instruction Manual Model

AES/EOU R-AUDIO2 R-AUDIO1 L-AUDIO1 L-AUDIO2 CVBS CVBS OUT R-AUDIO1 R-AUDIO2 ASI OUT2 GPI/LS DATA

ipump 562 Digital Media Server ipump 562 Digital Media Server User s Manual Rev. A

SAT IF distribution system

Dragon. manual version 1.6

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DSR-4520X IRD Set-Up and Configuration Guidelines for Direct Reception on Galaxy 13

HD Digital MPEG2 Encoder / QAM Modulator

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

FS4 Quick Start Guide

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Cisco D9865 Satellite Receiver

HD Digital MPEG2 Encoder / QAM Modulator

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Cablecast Server. Setup Guide. c Tightrope Media Systems For Cablecast version Build 74

N+1 Redundancy with the VCom HD4040 Upconverter

Hardware Setup. HP Dual TV Tuner/Digital Video Recorder. Document Part Number:

Agilis Fiber Optic Transceiver AFOT Series

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

Modular Matrix Solution. Complete A/V Signal Control in One Expandable System.

Honeywell HomMed Wireless Scale Quick Reference Guide

Cisco Explorer 8650HD DVR

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

First Time Setup Guide

MANUAL ENG DT-1000CI ENGLISH QPSK

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

QRF5000 MDU ENCODER AND QAM MODULATOR

Noise Detector ND-1 Operating Manual

Applications & Features of the SB- SDQM- 2130

Instruction Manual Model

Model /29S RF Splitter

Cisco D9824 Advanced Multi Decryption Receiver

T3316 IP QAM Modulator User Manual

QAM HD Integrated Receiver Decoder with SDI/HDMI/ASI/IP Signal Outputs. User Manual B-IRD-HD-PRO-Q HD IRD

Transcription:

ipump 6400 Professional Media Server Quick Start Guide Figure 4. ipump Web Interface Status Page 6. Shut down your ipump from the front panel. Navigate from the home screen to the Shutdown screen as follows: j. UNIT SETUP Menu k. UNIT STATUS DETAIL Menu l. NAVIGATION HELP Menu m. UNIT SHUTDOWN Menu n. ENTER Are You Sure?!!! No-ESC, Yes-ENTER (Press ESC to cancel or ENTER to shut down.) o. ENTER Press ESC to cancel or ENTER to shut down. Status Display At shutdown, the LCD screen becomes blank and the LED indicators go out. The ipump is now shut down. The power switch on the rear panel may be left in the on position for quick restart from the front panel. (See note in Step 4). 8000009-03 Rev. A 12 Professional Video Professional Video

Data, drawings, and other material contained herein are proprietary to Wegener Communications, Inc., and may not be reproduced or duplicated in any form without the prior written permission of Wegener Communications, Inc. The information contained herein is subject to change without notice. Revisions may be issued to advise of such changes and/or additions. WEGENER, COMPEL CONTROL, MEDIAPLAN, ENVOY, UNITY, UNITY IP, and ipump are trademarks of Wegener Communications, Inc. All other trademarks are the property of their respective owners. 2004 Wegener Communications, Inc. All rights reserved. Portions copyright 1992-2001 FairCom Corporation. "FairCom" and "c-tree plus" are trademarks of FairCom Corporation and are registered in the United States and other countries. All Rights Reserved. Correspondence regarding this publication, 800009-03 Release A First Edition: April 2005 should be forwarded to: Wegener Communications, Inc. Technology Park/Johns Creek 11350 Technology Circle Duluth, GA 30097-1502 Phone: 770-814-4000 Fax: 770-623-0698 The Wegener ipump 6400 is approved under FCC Part 15B Class A, UL1950, CSA, and CE. a. UNIT SETUP Menu b. ENTER RECORD AND PLAY Menu c. DECODER SETUP Menu d. AUDIO SETUP Menu e. IP SETUP Menu f. ENTER IP Address Data Display g. Record the IP Address of the ipump unit displayed on the LCD screen. h. Using a computer on the Ethernet LAN attached to the ipump, open your web browser. i. Type the IP Address noted from the IP Address screen in the browser's address box. Note: For IP addresses that include subfields with leading zeros, you must omit those zeros when entering the address in your browser. For example, IP address 128.092.056.004 would be entered as 128.92.56.4. Note: In some cases, it may be necessary to set specific values for the IP and Subnet addresses. Consult your network administrator. j. Press <Enter> (on the computer keyboard) and the ipump's Status page will be displayed (Figure 4). k. Click the appropriate tab to select Files, Schedule, Status, Help, or Setup. 800009-03 Rev. A 2 Professional Video Professional Video 11 800009-03 Rev. A

8 To configure your ipump's decoder output, navigate from the Home screen to the Decoder Setup screen as follows: a. ENTER RECORD AND PLAY Menu b. DECODER SETUP Menu c. ENTER DECODER NUMBER 1 (Available decoders are 1 and 2. If your ipump has only one decoder, this Decoder Number screen will not appear. Instead, the Decoder Setting Select screen described in step e will appear. d. DECODER SETTING SELECT: FOLLOW TUNE (FOLLOW TUNE accepts the program selection from the current RF setup and sends you back to the Decoder Setup screen. PROGRAM allows you to select a particular program from the stream. OFF turns off the decoder) If PROGRAM is selected, go on to step f. Otherwise your decoder setup is complete. e. ENTER ENTER PROGRAM NUMBER: 001 (Number of program to select from stream. Available program numbers are dependent on transport stream.) Your decoder setup is now complete. The selected program will begin playing from the selected decoder. 9 For web browser control and status checking, first navigate from the home screen to the IP Setup screen as follows: Welcome to your ipump Media Server/Store and Forward Receiver! Your Wegener ipump is an advanced multimedia appliance that allows simple, efficient management of both live and recorded digital video, audio, and data content. With a single unit, you can receive, decode, and play out broadcast-quality transmissions while receiving and recording multiple programs or IP data files from a satellite or TCP/IP connection. Along with our Compel MediaPlan software, you can insert content into real-time or recorded programs and can schedule playback of custom sequences of live and recorded content. This Quick Start Guide will help you quickly set up and start operating your ipump. For a full description of the ipump's abilities and detailed installation and operation instructions, please consult the ipump User's Reference Manual available on the worldwide web at wegener.com. For additional help, contact us by phone at (770) 814-4057, by fax at (678) 624-0294, or by email at service@wegener.com. 1. Remove your ipump, ac power cord, and bagged accessories from the shipping carton. Call your shipping carrier immediately if any damage is discovered. 2. Place your ipump indoors on a well-supported, flat table or desktop or mount it in a standard equipment rack. If rackmounting your ipump, please consult the ipump User's Reference Manual for detailed instructions and specific cautions. 3. Connect the following items (refer to Figures 1 and 2): f. The L-band output from your antenna's LNB to the ipump's RF input port (a) [950 to 2150 MHz; female Type F connector with extender cable attached or BNC connector if your unit has the optional ASI input] g. A suitable monitor to the ipump's audio port (b). [A DB-15 HD cable assembly is included.] h. A suitable video monitor to the ipump's video port (c1) [c1 is a female BNC for SDI.] or (c2) [c2 is a female BNC for composite video.] Note: Repeat steps (b.) and (c.) for the second decoder if your ipump is equipped with two decoders. 800009-03 Rev. A 10 Professional Video Professional Video 3 800009-03 Rev. A

i. Y our LAN line to the ipump's Ethernet port (d) [10/100baseT; female RJ-45 connector] Figure 1. ipump Rear-Panel Connectors The Alarm port (e, Figure 1) on the rear panel may be used to provide a contact closure during alarm conditions or on command from Compel. See the ipump User s Manual for complete connector and signal details. Figure 2. ipump Connections LED Label Color and State Meaning AUTH WARNING* ALARM* AMBER constant RED constant Current transport stream is protected by conditional access (CA) and ipump is authorized and descrambling. Current transport stream is protected by conditional access (CA) but ipump is unauthorized. Tracked channel is not scrambled ("in the clear"). One or more warning conditions exist. Read warning information from front-panel LCD. No warning conditions exist. One or more alarm conditions exist. Read alarm message from LCD. No alarm condition exists * Only one alarm or warning condition is displayed at a time on the LCD. When multiple alarm or warning conditions exist, those conditions are displayed in the order of importance. The most critical condition is displayed first and others may be viewed by pressing the right arrow button. 7. Set up or adjust your ipump's RF settings at the front panel. (If your unit has the optional ASI input, this step is not necessary - go to step 7). From the home screen, navigate to the RF Setup screen as follows: Note: Use the arrow buttons to move left and right through the menu screens and the ENTER button to move down a level. Use the ESC button to move upward through the menu screens. By pressing ESC repeatedly, you can always return to the ipump home screen. Note: Do not connect devices to the mouse, keyboard and other connectors not described here. They are for factory use only. a. ENTER UNIT SETUP Menu b. UNIT SETUP 8000009-03 Rev. A 4 Professional Video Professional Video 9 800009-03 Rev. A

The liquid crystal display (LCD) provides menu, data, and input screens to the user. Menu screens are entry points to further screens showing signal or unit status or to user-input screens that can be changed by the user. The "home" screen displays the ipump unit's Serial Number, Eb/N0, and alternately displays FEC Ratio, Signal Frequency, and Transport Rate. This screen may be reached at any time by repeatedly pressing the ESC button. Six pushbuttons allow you to move through the various screens, select characters for input, and accept or reject changes. To move downward or upward through the menu screens, use the ENTER and ESC buttons. To enter or change data in editable fields, press the ENTER button and use the up and down arrow buttons to increment the highlighted character or digit. Use the right and left arrow buttons to move to adjacent digits and press ENTER again to accept your input. Pressing ESC before accepting your input will cancel any changes. Eight light-emitting diodes (LEDs) illuminate to show unit status at a glance. Table 1 gives the meaning of each LED indicator. Table 1. LED Indicator Descriptions LED Label Color and State Meaning CARRIER RECORD DOWNLOAD LAN COMPEL Receiver is tracking carrier. Receiver is not tracking carrier. ipump is recording a program. ipump is not recording. ipump is downloading a file via Compel. ipump is not downloading. Light network activity over the ipump's LAN interface. Heavy network activity over the ipump's LAN interface. ipump observed no packet transfers during the last 20 secs. ipump has received a Compel command within the last two minutes. GREEN fast blink ipump has been addressed by Compel within the last five seconds. ipump is in tracking mode and Compel is required but no Compel command received within the last two minutes. 4. Next, start your ipump as follows: a. Connect the ac power cord to the ipump's IEC receptacle (f, Figure 1) and to a 100-to-120-Vac or 200-to-240- Vac source. b. Set the power switch to the On position ( I ) and press and hold the ENTER button on the front panel for two seconds. The ipump will power up and begin the boot process. Outputs are muted during the short initialization time. All eight LED indicators flash on and off as the unit begins initialization. Until you configure your ipump's RF settings (see Step 6), a loss-of-carrier alarm may be displayed (red ALARM LED indicator is lit and LCD screen indicates the alarm state). RF settings are not necessary for units with the optional ASI input. Note: To easily restart the ipump any time after a normal shutdown (see Step 9), simply press the ENTER button on the ipump s front panel (refer to the User's Manual for details). If the receiver is tracking a carrier signal, the green CARRIER LED will light. 5. Get to know the ipump's front panel Figure 3. ipump Front-Panel Controls and Indicators Liquid Crystal Display (LCD) LED Indicators Pushbuttons 800009-03 Rev. A 8 Professional Video Professional Video 5 800009-03 Rev. A

a. ENTER UNIT SETUP Menu b. UNIT SETUP Menu c. ENTER RECORD AND PLAY Menu d. DECODER SETUP Menu e. AUDIO SETUP Menu f. IP SETUP Menu g. RF SETUP Menu Note: To enter data in editable fields, press ENTER and use the up and down arrow buttons to increment the highlighted character or digit. Use the right and left arrow buttons to move to adjacent digits. Press ENTER again to accept your input or ESC to cancel changes. From RF Setup, adjust RF settings as follows: k. CURRENT CHANNEL Menu l. ENTER DOWNLINK FREQUENCY: XXXXX.XX MHz (Enter downlink frequency from the LNB local oscillator in megahertz.) m. TRANSP. DATA RATE: XXX.XX Mbps (Enter transport stream data rate in megabits per second.) n. RF-MOD/FEC RATIO: QPSK 3/4 (RF Modulation is QPSK. Available Forward Error Correction Ratios are 1/2, 2/3, 3/4, 5/6, and 7/8.) o. PROGRAM NUMBER: 00001 (Number of program to select from stream). Editable Editable Editable p. TAG SITE: <Unused> q. SAVE ALL CHANGES? YES<ENT> NO<ESC> (Press ENTER to save or ESC to cancel all RF Setup changes.) If you are satisfied with all data entered, press ENTER to save your changes. Pressing either ENTER or ESC (which cancels all changes) completes your RF setup and returns you to the Current Channel screen. If all settings are correct and the red ALARM LED remains lit, there may be a problem with the antenna, its position, or cable connections. Consult the ipump User s Manual for more troubleshooting help. 6. To configure your ipump's decoder output, navigate from the Home screen to the Decoder Setup screen as follows: h. ENTER RF STATUS: TRACKING: Eb/No = XX.X (RF status is shown. If tracking, then E b/n 0 is also displayed.) i. CURRENT CHANNEL Menu j. ENTER RF STATUS: TRACKING: Eb/No = XX.X (RF status is shown. If tracking, then E b/n 0 is also displayed.) Data Display Data Display 8000009-03 Rev. A 6 Professional Video Professional Video 7 800009-03 Rev. A