GSCmini - Pneumatic Timer Based Valve-Gate Sequence Controller lnstruction Manual

Similar documents
GSC2mini - Pneumatic/Hydraulic Timer Based Valve-Gate Sequence Controller lnstruction Manual

GSC2mini - Pneumatic/Hydraulic Timer Based. lnstruction Manual

1. Uses. 2. Power Supply. 1) Removal or Positioning of Weld Lines. 2) Regulation of the Injection Quantity by Gate Operation

Operating instructions Electronic preset counter Type series 717

MATE3 Owner s Manual Addendum

Synchronization Check Relay ARGUS 7

Sprite TL Quick Start Guide

STD-525T PRECISION TIMER

Revision 1.2d

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

AT450SAW Programmable Selective Amplifier

(Cat. No IJ, -IK)

Operating Manual. Basic Control BC16. two-channel for eco moon

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

Sentinel I24 Digital Input and Output Configuration

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Standard signal metering in wall-mounting case

Table of Contents. 1. Description of Timer!!! Operating Instructions!!! Operation Examples!!!

COMPONENTS & COMPONENTS & ACCESSORIES

INSTRUCTION MANUAL. J800 Weld Controller. 3/25/2018 Revision

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

AT47SAW Programmable Selective Amplifier

FOREST SHUTTLE S / L / M RECEIVER

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Modular Lube Lubrication Systems System Controls

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

K9123, K9134, K9135 Remote Programming Instructions and Specifications

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Battery Operated Controllers

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Junior Max (JR Max ) Controller

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

LED Backlight for Technics amplifiers

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

Intellex Digital Video Management System. Troubleshooting Guide

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Valve Amplification Company

RECT-STx-XXX and RECT-STx13-XXX Triple Lamp Operational and Programming Instructions

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Digital differential pressure controller Model DPD Instruction manual

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Specification Type 1.1 Interface

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

STX Stairs lighting controller.

Digital differential Pressure switch Model DPS Instruction manual

ATS50SAW Programmable Selective Amplifier

Installing the FOREST SHUTTLE S / L

Troubleshooting CS800/LC900 Bikes

Thermo-Simple 1 version 2 (TS.1 ver.2) 2013

K3NX Process Meter OPERATION MANUAL

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

User Manual M1 - tricolour

Style 5S Clock / Timer

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Operating Instructions

Operating Instructions

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

MANUAL ENG DT-1000CI ENGLISH QPSK

Operational & Programming. Instructions Manual 930L. Lightbar Series

Arbor Scientific PO Box 2750 Ann Arbor, Michigan (800) Timer & Photogates 2.0 P Owners Manual

Multi-functional safety relay modules PROTECT SRB-E

ICOD PLUS instruction manual

Rebis Audio Ltd. RA226 Digital Sampler User Guide

BooBox FlexMax. OPERATING MANUAL V1.1 (Aug 14, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

Solid-State Digital Timer

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

Camera 220C Document Camera User s Guide

SureFire PDI Lubricator

IEFIS G3 Inputs, outputs and Alarms

INSTALLATION & USER GUIDE

OWL micro+ WIRELESS ELECTRICITY MONITOR

User Manual M1 - tricolour

Sample BD Tech Concepts LLC

MS2540 Current Loop Receiver with RS485 Communication

Transcription:

lnstruction Manual

CONTENTS 1. Power 4. Getting Started 2. Interface Features 5. Mode Examples 3. Mode Descriptions 6. Wiring Specifications CAUTION A minimum of one gate must be opened at the start of the injection fward (signal) (time=0sec.) with zero (0) Delay (DEL) time. Failure to do so may cause damage to the Hot Runner system. * Unit will have a facty setting: Gate 1 will be set with a default of zero (0) Delay time and 1 second Open time. Page 2 2016 INCOE 08/16 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com

1. POWER A) Main Power Input: 115/120/220 VAC B) Signal Input Power: 24 VDC from Machine when Injection Fward C) Solenoid Valve Output Power: 24 VDC Less than 100mA per GATE 2. INTERFACE FEATURES 12 11 10 1 2 3 4 7 8 9 5 6 1 Left Select 6 Machine Injection Fward/Mold 10 OPEN LED indicates the gate is open 2 Up Select Closed 24 VDC Signal Input Indicat 11 OPEN display indicates time gate 3 Right Select 7 Mode A Indicat LEDs remains open 4 Down Select 8 Mode B Indicat LEDs 12 DELAY (DEL) display indicates time 5 Ouput Voltage LED Indicat 9 Mode B2 Indicat LEDs when gate is to open 2016 INCOE 08/16 Page 3 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com

3. MODE DESCRIPTIONS Mode A - Able to set Delay (DEL) Time only. All gates stay open during injection signal (Mode A LEDs are illuminated). Mode B - Able to Set Delay Time and Open Time (Mode B LEDs are illuminated). Mode B2 - Able to set Delay Time, Open Time and Second Delay Time and Open Time (Both Mode A & Mode B LEDs are illuminated). Gate Off - A/B Mode LEDs, DEL /OPEN display panel off. 4. GETTING STARTED Connect Cables from GSCmini 1. Connect 24 VDC output cable to Solenoid Valve Stack. 2. Connect 24 VDC input cable to injection fward machine output. 3. Plug in unit to a 120 VAC power outlet. Power on Press Power To Select Mode 1. Press and Hold Mode f 4 seconds. Mode LED of 1st gate flashes. 2. While Mode LED is flashing press up down to scroll through mode types (A Mode B Mode B2 Mode (A & B mode LEDs will be flashing) Off (A & B flashing separately). 3. Press left right to change between gates and repeat mode selection f each gate. This must be done while displays are flashing mode function times out and Mode will need to be pressed again. 4. Keep idle f 4 seconds to automatically save. GSCmini - Pneumatic Timer Based Valve-Gate Sequence Controller To Change Unit Selection (Decimal Placement): 1. Move to Gate (1-8) using While Gate DEL Display is flashing, press and hold Mode f 4 seconds,"uni" (Unit) displays in DEL panel and 999 99.9 / 9.99 displays in OPEN panel f that gate. 2. While OPEN panel digits are flashing press up Page 4 2016 INCOE 08/16 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com down to change unit selection (decimal place) f that gate. 3. Once unit is selected f that gate, press left right to change between gates and repeat unit selection (#2). Must be done while displays are flashing Unit Selection times out and must repeat unit selection process. 4. Keep idle f 4 seconds to automatically save. To Manually Open Gates: A. To Manually Open all Gates 1. Press OPEN 2. To close Gates press Open again. B. To Manually Open an Individual Gate 1. Move to Gate (1-8) using 2. Once at selected gate, press OPEN while the Gate Display is flashing.

To Set DEL Time In Mode A 1. Set desired gates to Mode A. 2. Move to Gate (1-8) using 3. Once at selected Gate, press Enter to select (Right Digit in DEL display will flash). 4. To set the time, press up down while DEL display is flashing. 5. To move between digits, press left right. 6. Press Enter keep idle f 4 seconds to automatically save. To Set DEL Time AND OPEN Time In Mode B 1. Set desired gates to Mode B. 2. Move to Gate (1-8) using 3. Once at selected gate, to change between DEL and Open display press up down. While display is flashing press Enter to select (Right Digit in display will flash). To Set 1st and 2nd DELAY Time AND OPEN Time In Mode B2 1. Set desired gates to Mode B2. 2. Move to Gate (1-8) using 3. Once at selected gate de1 (Delay 1) will be displayed. Press up down to scroll through op1 (Open 1), de2 (Delay 2) and op2 (Open 2). The Delay Open value will be flashing below. 4. Press Enter to select (Right Digit in display will flash). 5. To set the time, press up down while digit is flashing. 6. To move between digits, press left right. 7. Press Enter keep idle f 4 seconds to automatically save. 4. To set time, press up down while display is flashing. 5. To move between digits, press left right. 6. Press Enter keep idle f 4 seconds to automatically save. 2016 INCOE 08/16 Page 5 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com

5. MODE EXAMPLES CAUTION: A minimum of one gate must be opened at the start of the injection fward (signal) (time=0 sec.) with zero (0) Delay (DEL) time. Failure to do so may cause damage to the Hot Runner system. MODE A MODE B Select Mode A to have a Closed Gate open at a set delay time (DEL). Select Mode B to have a Closed Gate open at a set delay time The gate will remain open until injection signal is finished. (DEL). Then close that gate at a set open time. INJECTION INJECTION T 0 sec 4 sec 10 sec EXAMPLE: (First gate opens at Signal (not shown). Second gate opens 4 seconds later). 1. Injection signal: 10 seconds and DEL time: 4 seconds. After DEL time, gate 2 opens f 6 seconds. 2. The delay time counts down and displays it in DEL display panel, and just after DEL time, gate 2 opens. 3. If injection signal is off befe delay time passed, the gate will not open. 4. After DELAY time has passed and the injection signal remains on, gate 2 opens, and displays that time in the OPEN display panel. 5. When injection signal is off, delay set time will be displayed in DEL display panel. The OPEN display panel displays counted open time until next injection signal comes on. 0 sec 4 sec 10 sec EXAMPLE: (First gate opens at Signal (not shown). Second gate opens 4 seconds later). 1. Injection signal: 10 seconds, DEL time: 4 seconds and OPEN time: 4 seconds. When injection signal comes on, after DEL time, the gate opens f OPEN time (4 seconds). 2. The delay time counts down and displays it in DEL display panel. 3. If injection signal is off befe delay time passed, the gate resets to set time. 4. When injection signal is off, delay set time and open set time will be displayed in DEL display panel OPEN display panel respectively. Page 6 2016 INCOE 08/16 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com

MODE B-2 Select Mode B-2 to have a Closed Gate open at a set Delay (DEL) time. The gate will remain open past the injection fward signal f a set time (Pack and Hold Phase). 6. WIRING SPECIFICATIONS GSCmini - Pneumatic Valve-Gate Sequence Controller INJECTION (Figure 1) (Figure 2) 0 sec 4 sec 10 sec -4 sec EXAMPLE: (Keeping gate open during pack and hold phase). Injection time: 10 seconds, DEL time: 4 seconds, open time: - 4 seconds) Note: Open time is entered as a negative number. 1. The gate gets the injection signal and after 4 seconds open the gate then the gate stays open during signal time. After the injection signal is completed, the gate stays open f the next 4 seconds and then close the gate. 2. The delay time counts down and displays it in DEL display panel. After DEL time it displays OPEN time until finishing signal. After that, it counts down and displays in OPEN display panel. 3. If injection signal is off befe delay time passed, the gate becomes initialization as setting time. VALVE 1 VALVE 2 VALVE 3 VALVE 4 VALVE 5 VALVE 6 VALVE 7 VALVE 8 2 4 1 9 3 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 COMMON (Figure 3) (Figure 4) 1. Power Input Connection: Connect power plug in 115/120/220 VAC socket (Figure 2). 2. Signal Input Connection: Connect cable signal injection output (Figure 2). 3. Gate Output Connection 4. Connect Solenoid Valve (Figure 3 and Figure 4). CAUTION Use the same electric poles using 24 VDC Solenoid Valve connection. 2016 INCOE 08/16 Page 7 INCOE Cp. Global Headquarters 1740 E. Maple Road Troy, MI 48083 USA T: 248-616-0220 E: tech.suppt@incoe.com www.incoe.com

INCOE Cpation Global Headquarters 1740 E. Maple Road Troy, Michigan 48083 USA T: + 1 (248) 616-0220 E: info@incoe.com Technical Suppt: T: + 1 (248) 556-7790 E: tech.suppt@incoe.com Customer Service and Sales: T: + 1 (248) 556-7770 E: customer.suppt@incoe.com