Single sensor setup with NIVEL210

Similar documents
TeamWork Installation Guide

Installation Note. Agilent 89441A Option AYC Installation Kit

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Camera Setup Instructions

G.R.A.S. Sound & Vibration

Collator series 300/400, 310B Spare parts list

TeamWork Kits Installation Guide

Site Installation Model MP-8433

Site Installation Model MP-8424

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

FELIX3.1 assemblymanual

Contents Section 9, Illustrated Parts

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HDMI over CAT5 HDBaseT Extender - 4K

DX-10 tm Digital Interface User s Guide

8341LS PRODUCT SPECIFICATIONS MODEL 8341LS LED BASEBALL SCOREBOARD OUTDOOR SCOREBOARD. Baseball 10-Inning Line Score

Mounting Set ACCESSORIES

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

DLMP-45/45R Installation Instructions

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

Cable ISOBUS Active Termination

User Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708)

P-2 Installing the monitor (continued) Carry out as necessary

Installation Operation Maintenance

HC20 Healthcare Kit Installation Instructions

VNS2210 Amplifier & Controller Installation Guide

Cabling and Completing Assembly of the Cisco TelePresence System 1000

Field Service Procedure Replacement GACP Control Panel Kit, ST24

SERIES 400 SERIES 620

USER S MANUAL

LineLight Crosswalk Installation Manual: Solar Panel & Motion Radar

Connecting cables NEBS, for sensors

Optical Distribution Box 300 Installation Guide. Version : R0.0

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

HDMI over Wireless Extender - 65 ft. (20 m) p

FPM Series. Industrial Flat Panel Touch-Screen Monitors

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

VNS2200 Amplifier & Controller Installation Guide

Dual extruder upgrade manual addendum to assembly manual

Revision 1.0 Parts List Minor

Bionic Elephant Trunk. Assembly Instructions

NewScope-7A Operating Manual

TeamWork 601 Kit Installation Guide

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

Active UTP Transceiver Hub Installation Guide

Connecting cables for valves, round plug connectors Product range overview

What You Need to Get Started USER GUIDE

Agilent 11713A Attenuator/Switch Driver

Adder 882i Intercom/Data Multiplexer

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

Digital Clock with Second Circle DA Series

TELEDYNE HASTINGS INSTRUMENTS

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Field Service Procedure Replacement PCU Kit, Coastal

Lt DELTA USA, Inc

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

MAXX BOX. MX102/202 Series. MAXX Box

VPS1 Installation Manual

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

MultiView 9D Cat5 Distribution Amplifier

HighBand 25. TrueNet Category 6 Solutions

AristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection

COPYRIGHT NOVEMBER-1998

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

COMPONENTS & COMPONENTS & ACCESSORIES

TeamWork Kits Installation Guide

OPTICAL TRANSMISSION SOLUTION.

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Quick Operation Guide of LTN7700/7600 Series NVR

ivw-ud322 / ivw-ud322f

Revision 1.0 Parts List Salvador 1~, 3~

VersaCap Lighting System

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Hex-color RGBAW+UV LED strip light

User Guide MD755. Programmable Motion Sensor for BrightSign Solid State Digital Sign Controllers. Overview

DLMP Installation Instructions

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

Systems Pow-R Breakers Renewal Parts and Accessories

Vocia VI-6. Operation Manual

ICS Digital Menu. Installation Guide Version 1.1

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

Mini Micro Pulse Lidar System

Magnetic Sensor - Incremental EHP

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Snail Fence InteleCell Deployment Guide

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

E3/DS3 Fibre Extender

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

1.1 Introduction Getting Connected Guide - Wireless Setting up a Wireless Network Getting Connected Guide - Wired...

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Multi-Format AV Scaler with DisplayPort

Transcription:

Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748 335 722 409 Regional and local Leica support specialists will help you selecting the optimal equipment configuration.

Single sensor setup with NIVEL210 and GPS1200 Essential Items: 576 198 NIVEL210 RS232 749 916 Cable, Lemo 0 GPS1200 port 1,2 or 3 GPS1200 GPS1200 576 198 749 916 Regional and local Leica support specialists will help you selecting the optimal equipment configuration.

Multiple sensor setup with NIVEL220 Essential Items: Cable, Converter RS232 / RS485 bus converter 748 488 Cable, Lemo 1 - Converter 722 409 Power supply 748 489 Cable, Converter - Lemo 0 576 199 NIVEL220 RS485 802 906 or 802 907 Cable, Lemo 0 - Lemo 0 576 199 NIVEL220 RS485 802 906 or 802 907 Cable, Lemo 0 - Lemo 0 - or 575 869 Terminator In order to run the bus system properly it has to be terminated. This has to be done via the terminator resistor. 576 199 576 199 Cable, Converter RS232 / RS485 bus converter 748 488 748 489 802 906 or 802 907 802 906 or 802 907 or 575 869 722 409 Regional and local Leica support specialists will help you selecting the optimal equipment configuration.

NIVEL200 equipment 1. NIVEL200 sensors: Select the NIVEL200 sensor 576 198 NIVEL210, inclination sensor RS232 576 199 NIVEL220, inclination sensor RS485 2. Power supply equipment: 2.1 Continuous 12V Power supply A permanent 12V power supply is needed for a NIVEL200 sensor, except for using in combination with a GPS1200. 722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60 HZ, output 12VDC, cable with 5 pin Lemo. Standard mains/line cable select from following list. Can be used for NIVEL200 sensors. Select power cords for 12V power supply unit 722 409: 731 772 Power Cord for Dual Bay Charger GKL24 or NIVEL200 Power supply unit, US-Version. 731 773 Power Cord for Dual Bay Charger GKL24 or NIVEL200 Power supply unit, EU-Version. 734 232 Power Cord for Dual Bay Charger GKL24 or NIVEL200 Power supply unit, UK-Version. 734 233 Power Cord for Dual Bay Charger GKL24 or NIVEL200 Power supply unit, AUS-Version. 738 586 Power Cord for Dual Bay Charger GKL24 or NIVEL200 Power supply unit, CH-Version. 2.2 Power cables To connect power supply to NIVEL210 sensor. 748 335 1.7 m power supply cable, connects NIVEL210 sensor to power supply unit 722 409. To connect power supply to NIVEL220 sensor. Refer to 5. Converter.

3. Cables: 3.1 Power supply cables Refer to 2. Power supply equipment. 3.2 Communication cables Essential cable, at least one should be ordered for each NIVEL210 sensor, except for using in combination with a GPS1200. Direct serial connection: 802 902 1.0 m Connection cable. Connects NIVEL210 sensor Ports 1 and 2 to for data communication etc. Lemo to 9 pin RS232 serial connector. 3.3 Bus system cables Essential cable, at least one should be ordered between each NIVEL220 sensor 802 906 5.0 m Connection cable RS485. Connects two NIVEL220 sensors Ports 1 or 2, Lemo to Lemo. 802 907 20.0 m Connection cable RS485. Connects two NIVEL220 sensors Ports 1 or 2, Lemo to Lemo. 3.4 RS232 / RS485 Converter cables Refer to 5. Converter. 3.5 GPS1200 communication / power cable 749 916 1.8m communication and power cable, GEV209, Nivel210 to GPS1200

4. To mount NIVEL200 sensor: Holder for fixed mounting of NIVEL200 sensors. 749 031 Wall Mounting Kit for NIVEL200 sensors. Each Wall Mount kit comprises: 1x steel assembly (chemical nickel-plated, including 1x angle profile, 1x turning flange with screw and spring for adjustment, 3x M5 ball pressure screws, 3x M4 sensor screws, cable tie fastener with screw) 3x M6 brass plugs 3x M6 screws 3x M6 washer 2x cable tie C C C E B D A G B F B A B C D E F G - M6 screw - M6 screw and M6 washer - M4 screw - Flange assembly - M5 ball pressure screw - Centre screw - Nuts

5. Converter: 5.1 RS232 / RS485 Converter Leica Geosystems recommends to use the following RS232 to RS485 converter: I-7520 http://www.icpdas.com 5.2 RS232 / RS485 Converter cables Essential cable, at least one should be ordered for each converter Power supply cable: 748 488 0.8 m power supply cable, connects power supply unit 722 409 to RS232 / RS485 converter, Lemo 2 wires to terminal strip. Communication cable: 748 489 1.8 m communication cable, connects NIVEL220 sensor to RS232 / RS485, Lemo 4 wires to terminal strip. 6. Terminator: One terminator must be ordered and installed for each structural monitoring installation with NIVEL220 sensors. 575 869 Terminator for RS485