A New 4MW LHCD System for EAST

Similar documents
Detailed Design Report

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

RF Solutions for Science.

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

High-power klystrons. The benchmark in scientific research. State-of-the-art RF sources for your accelerator

XFEL High Power RF System Recent Developments

RF Power Generation II

INFN School on Electron Accelerators. RF Power Sources and Distribution

TOSHIBA Industrial Magnetron E3328

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Next Linear Collider. The 8-Pack Project. 8-Pack Project. Four 50 MW XL4 X-band klystrons installed on the 8-Pack

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

CPI Gyrotrons For Fusion EC Heating

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

RF Upgrades & Experience At JLab. Rick Nelson

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

ANKA RF System - Upgrade Strategies

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

Development of high power gyrotron and EC technologies for ITER

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

IOT RF Power Sources for Pulsed and CW Linacs

DEVELOPMENT OF X-BAND KLYSTRON TECHNOLOGY AT SLAC

The LEP Superconducting RF System

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

Chris Gilmour Studies into the Design of a Higher Efficiency Ku Band ring-loop Travelling Wave Tube SWS using the CST PIC Software.

Solid State Modulators for X-Band Accelerators

SPINNER BROADCAST EXPLANATION OF THE MULTI CHANNEL COMBINER SPECIFICATIONS

X-Band Klystron Development at

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

SLS RF operation report 2003

Limitations of a Load Pull System

North Damping Ring RF

Pulses inside the pulse mode of operation at RF Gun

Status of BESSY II and berlinpro. Wolfgang Anders. Helmholtz-Zentrum Berlin for Materials and Energy (HZB) 20th ESLS-RF Meeting

Modifying the RW1127 and similar TWTs for 24GHz

Modulator Overview System Design vs. Tunnel Topologies. Snowmass Workshop August 16, 2005 Ray Larsen for the SLAC ILC Group

MILLIMETER WAVE VNA MODULE BROCHURE

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Studies on an S-band bunching system with hybrid buncher

Empirical Model For ESS Klystron Cathode Voltage

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

OF THIS DOCUMENT IS W8.MTO ^ SF6

DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING QUESTION BANK

LH Systems International Status and Prospects

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

P P S - M W S C A N 1 H

Investigation of Radio Frequency Breakdown in Fusion Experiments

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

Spear3 RF System Sam Park 11/06/2003. Spear3 RF System. High Power Components Operation and Control. RF Requirement.

High Power ARNS/IFF Limiter Module: Ultra Low Flat Leakage & Fast Recovery Time

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

Power Amplifier 0.5 W 2.4 GHz AM TR Features. Functional Schematic. Description. Pin Configuration 1. Ordering Information

Present Status and Future Upgrade of KEKB Injector Linac

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Recent ITER-Relevant Gyrotron Tests

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

CEPC Klystron Development

The PEFP 20-MeV Proton Linear Accelerator

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

ILC-LNF TECHNICAL NOTE

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

Screen investigations for low energetic electron beams at PITZ

!"!3

J/NLC Progress on R1 and R2 Issues. Chris Adolphsen

Parameter Symbol Units MIN MAX. RF Input power (CW) Pin dbm +23

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

650MHz/800kW Klystron Development at IHEP

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

Synchrotron Light Facility. Operation of ALBA RF. Angela Salom on behalf of RF team: Francis Perez, Bea Bravo and Jesus Ocampo

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Prisma Optical Networks Ancillary Modules

STATUS OF THE SwissFEL C-BAND LINAC

Parameter Symbol Units MIN MAX. RF Input Power (CW) Pin dbm +20. LO Input Power (CW) Pin dbm +27

OPTICAL DISTRIBUTION STATION -

US-ILC Waveguide Industrialization Study. Marc Ross, Chris Nantista and Chris Adolphsen

RF POWER GENERATION FOR FUTURE LINEAR COLLIDERS* 1. Introduction

Hitachi Kokusai Electric Comark LLC

CEBAF 8 kw CW KLYSTRON SPECIFICATION EE0043, Rev. H January 15, 1998

Advanced Test Equipment Rentals ATEC (2832)

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

GaAs MMIC Triple Balanced Mixer

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

USB Mini Spectrum Analyzer User s Guide TSA5G35

Synthesized Block Up- and Downconverter Indoor / Outdoor

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

Features. = +25 C, 50 Ohm System

Transcription:

1 EXW/P7-29 A New 4MW LHCD System for EAST Jiafang SHAN 1), Yong YANG 1), Fukun LIU 1), Lianmin ZHAO 1) and LHCD Team 1) 1) Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, China E-mail contact of main author: yangyon@ipp.ac.cn Abstract. To achieve a steady-state operation of the Experimental Advanced Superconducting Tokamak (EAST) with high parameters and to control its plasma current density profile more actively and effectively, a new 4MW/2.45GHz Lower Hybrid Current Drive (LHCD) system will be upgraded from the present 2MW/2.45GHz system. It is expected to couple more than 3MW lower hybrid power into EAST plasmas and to sustain 0.8MA non-inductive current with a central line averaged electron density at 2 10 19 m -3 and 0.6MA at 4 10 19 m -3. Key technologies developed for new 4MW LHCD system are presented in this paper, which including the power source, multi-junction antenna, high voltage power supplies, different protection and control subsystems. The experimental results with the present 2MW LHCD system are also given briefly in this presentation. 1. Introduction It is well known that the Lower Hybrid Current Drive (LHCD) is an effective non-inductive approach to modify the plasma current density profile and to improve the plasma confinement in tokamaks [1]. To achieve a steady-state operation of the Experimental Advanced Superconducting Tokamak (EAST) with higher parameters and to control its plasma current density profile more actively and effectively, a 4MW/2.45GHz LHCD system will be upgraded from the present 2MW/2.45GHz system. It is expected to couple more than 3MW lower hybrid power into EAST plasmas and to sustain 0.8MA non-inductive current with a central line averaged electron density at 2 10 19 m -3 and 0.6MA at 4 10 19 m -3. Key technologies developed for 4MW LHCD system will be presented in this paper, which including the power source, multi-junction antenna, water cooling subsystem, high voltage (HV) power supply, different protection and control subsystems. The experimental results with the present 2MW LHCD system are also given briefly in this article. 2. System Design The overall structure of the new 4MW LHCD system is same to the present 2MW LHCD system, which is shown in Fig.1. The core of the microwave power source is composed of 20 2.45GHz klystrons and the multi-junction waveguide array is adopted in the design of antenna with the passive sub-waveguides.

2 EXW/P7-29 Fig.1. The structure of 4MW LHCD system for EAST The main technical items of new LHCD system are listed in the following table: Frequency 2.45GHz Power 4MW(20 200KW CW) Pulse width 1000S Antenna 5 4 8 Multi-junction N // 1.84~2.83 Max. Power Density 30MW/m 2 To meet the need of the new LHCD system, the modification of several subsystems is necessary, which including the klystrons, transmission lines, HV power supplies, water cooling subsystem and overcurrent protection subsystem. The main parts of the new LHCD system will be described as follows. 2.1 Power Source The power source of the 4MW LHCD system is composed of the low power microwave drive and 20 high power microwave klystrons. The drive of the klystrons consists of one master oscillator, one PIN modulator, two power dividers and 20 independent microwave chains. The master oscillator has three outputs: two 30dBm outputs are connected to power dividers respectively and one 20dBm output is acted as the phase reference of the phase control subsystem. The power divider has 12 outputs, 10 of which are used and 2 reserved. The maximum output of each microwave chain is 3W, which is made up of one digital phase shifter, one PIN switch, one DC break, one amplifier with the voltage controlled attenuator and one power detector. The output of each drive chain is connected to the microwave input of the corresponding klystron with a coaxial cable.

3 EXW/P7-29 The technical parameters of 20 high power microwave klystrons are listed in the table 1 and as the core of 4MW LHCD system s power source, the klystrons are installed on a two level platform, which is shown in Fig.2. Transmission lines working in a TE10 mode are installed between klystrons and the antenna. Each transmission line consists of a four-port high power ferrite isolator, a standard rectangular waveguide (WR430) with a length of 30m to 40m, a flexible rectangular waveguide of 1m, two 99% Al2O3 ceramic windows, two bidirectional couplers and so on [2]. The total loss of each transmission line is about 1.0dB to 1.1dB. The waveguide between two ceramic windows is filled with 1 atmospheric pressure nitrogen to smooth the wave transmission. If the ceramic window closer to the tokamak breaks down, the nitrogen will be pumped out and the vacuum will be maintained by the second ceramic window. TABLE 1: TECHNICAL PARAMETERS OF THE KLYSTRON. Operating frequency 2.45GHz Output power 200KW Input microwave power 0.3~1.0W Gain 53dB Input HV power Max 420KW Beam voltage -40~-46KV Beam current 10A Efficiency 50% Fig.2. The structure of the klystron and waveguide assembly

4 EXW/P7-29 2.2 Multi-junction Antenna To meet the need of plasma physics, the multi-junction waveguide array (5 rows 4 columns) shown in Fig.3 is adopted in the design of antenna. Each main waveguide, whose width is expanded from 54.6mm to 101mm by the H-plane transformer, is divided into 8 active sub-waveguides with a fixed adjacent phase difference of 90 o and the passive sub-waveguides are inserted between waveguides and both sides. Thus the whole launcher is composed of 185 sub-waveguides, 160 active sub-waveguides and 25 passive sub-waveguides, and the size of each sub-waveguide is 109.2mm 10mm with a thickness of 2mm.The water cooling tubes put between two waveguide rows and the graphite guard limiters are designed to protect the antenna from overheating [2]. The parallel refractive index N // of the antenna can be adjusted from 1.84 to 2.83 by changing the phase difference between the adjacent main waveguides and its power density spectrum is demonstrated in Fig.3. For a better coupling, the antenna can be moved horizontally up to 300mm by a hydraulic position controller. Fig.3. The installed LHCD antenna and its power spectrum 2.3 HV Power Supplies Four sets of high voltage power supplies, each feeds five klystrons, are employed in the new 4MW LHCD system. The rated voltage and current of each new 200KW klystron s high voltage input are -42KV and 9A. Thus, it is necessary to upgrade the present phase controlled HV power supplies from -33KV/40A to -46KV/50A. For making the best use of the present HV power supplies, four sets of -20KV/50A power supplies based on the Pulse Step Modulator (PSM) technology are used in the design of new HV power supplies. A PSM power supply and a present HV power supply are connected in series to form a needed -46KV/50A power supply.

5 EXW/P7-29 Because of the limitation of the phase controlled HV power supplies, the rise time of new HV power supplies is about 50ms. For a faster rising, the phase controlled HV power supplies should be replaced with the PSM HV power supplies in the future. 2.4 Water Cooling Subsystem The high power devices in the LHCD system, such as klystrons, transmission lines, multi-junction antenna and so on, are in need of water cooling. Each new 200KW klystron needs a water flow of 20T/h instead of the former 100KW klystron s 10T/h. According to the demands of different devices, two water pumping stations with different output pressures are designed in the water cooling subsystem. The water pressure of one station is 8 atm for the cooling of klystrons, solenoids, high power ferrite isolators and antenna. The other is 4 atm for the cooling of transmission lines and ceramic windows. 2.5 Protection and Control Subsystems The protection and control subsystems are designed to meet the demand of the physical experiments on EAST and the security of LHCD system. The demand of EAST experiments mainly includes: the radiated microwave power and the phase difference between the adjacent main waveguides of the antenna can be adjustable; the parameters can be set remotely by EAST central control system and the experimental data of LHCD system can be accessed remotely. The demand of system security mainly includes: the protection of arc and high reflected microwave power; the overcurrent protection of the klystrons electron collector and body; the measurement and monitoring of the devices state and physical parameters. The LHCD protection and control subsystems consist of the LHCD central control console, the arc and high reflection protection subsystem, the power/phase control subsystem and the data acquisition and processing subsystem. Due to the advantage of high realtime performance and reliability for mission-critical applications, QNX realtime operation system (RTOS) is adopted for guaranteeing the successful operation of LHCD system in the physical experiments [3]. As the most widely used tool for the storage and management of the complex scientific data in the magnetic fusion energy program, MDSplus is also employed in the EAST LHCD system and a researcher with permissions can access data stored in this database anywhere on the internet [4]. 3. Experimental Results The plasma shape and position could be optimized to maximize the wave coupling into the plasma with newly developed plasma control algorithm. Maximum 1.2MW power of LHW at a fixed parallel refractive index N peak = 2.3 has been successfully delivered, with 80% power being coupled into the plasma. With the assistance of LHCD system, the low loop voltage plasma startup has been studied for reducing the current ramping rate in the PF coils and increasing the safety of machine operation. The fully non-inductive plasma discharge with double null configuration has been sustained

6 EXW/P7-29 over 60s when about 600KW LHW power applied, which is shown in the Fig.4. The longer plasma discharge will be obtained if the performance of heat load on the plasma facing components (PFCs) is improved [5]. Fig.4. Plasma discharge over 60s with 2MW LHCD system on EAST. The curves from top to bottom: plasma current, central line averaged density, loop voltage, LHW forward power, LHW reflected power. 4. Summary The 4MW/2.45GHz LHCD system for EAST will be built up based on the present 2MW/2.45GHz system and the modification of several subsystems is now in progress. With new 4MW LHCD system, it is expected to couple more than 3MW lower hybrid power into EAST plasmas and to sustain longer non-inductive current with high plasma parameters for operating tokamak in a steady state and studying advanced plasma physics. Meanwhile, there is still some space for the improvement of the whole system. Acknowledgements Give thanks to all the researchers and friends of LHCD team for all your encouragement and assistance. References [1] Wesson J. Tokamaks (1997). Clarendon Press, Oxford. [2] ZHAO Lianmin, et al., Plasma Sci. Technol. 12 (2010) 118. [3] QNX Neutrino RTOS (2004). QNX software system Itd.

7 EXW/P7-29 [4] Qu L.Z., et al., Application of MDSplus in Data System of HT-7 Tokamak, Computer Engineering, vol. 32, pp. 64-66, March 2006. [5] B. Wan, et al., Fusion Eng. Des. (2010). In press.