Silicon Microstrip Detectors for the ATLAS SCT

Similar documents
ATLAS QA Procedures for Silicon Microstrip Detectors

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Status of CMS Silicon Strip Tracker

DEPFET Active Pixel Sensors for the ILC

The ATLAS Pixel Detector

THE ATLAS Inner Detector [2] is designed for precision

The Status of the ATLAS Inner Detector

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Results on 0.7% X0 thick Pixel Modules for the ATLAS Detector.

CMS Upgrade Activities

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

A pixel chip for tracking in ALICE and particle identification in LHCb

The Silicon Pixel Detector (SPD) for the ALICE Experiment

Electronics procurements

The field cage for a large TPC prototype

The hybrid photon detectors for the LHCb-RICH counters

Features. = +25 C, Input Drive Level = +15 dbm. Parameter Min. Typ. Max Min. Typ. Max. Units. Frequency Range Input GHz

Hamamatsu Silicon Sensors

Flexible Electronics Production Deployment on FPD Standards: Plastic Displays & Integrated Circuits. Stanislav Loboda R&D engineer

High ResolutionCross Strip Anodes for Photon Counting detectors

Advanced WLP Platform for High-Performance MEMS. Presented by Dean Spicer, Director of Engineering

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

Review Report of The SACLA Detector Meeting

Features. = +25 C, LO = 36.1 GHz, LO = +15 dbm, LSB [1] Parameter Min. Typ. Max. Min. Typ. Max Min. Typ. Max Units

Technology Overview LTCC

Sensors for the CMS High Granularity Calorimeter

Features. = +25 C, LO = 50 GHz, LO = +12 dbm, USB [1] Parameter Min. Typ. Max. Units. RF Frequency Range GHz. LO Frequency Range GHz

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Features. = +25 C, IF = 1 GHz, LO = +13 dbm*

SLHC- PP EU DELIVERABLE: SLHC-PP v1.0. End of Month 36 (March 2011) 23/03/2011. Integration in full-scale detector modules

A Review of Tracking Sessions

Features. = +25 C, IF = 1GHz, LO = +13 dbm*

arxiv:hep-ex/ v1 27 Nov 2003

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

SR1320AD DC TO 20GHZ GAAS SP3T SWITCH

The Time-of-Flight Detector for the ALICE experiment

MAAP DIEEV1. Ka-Band 4 W Power Amplifier GHz Rev. V1. Features. Functional Diagram. Description. Pin Configuration 2

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Standard Operating Manual

A Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout

RX40_V1_0 Measurement Report F.Faccio

Features OBSOLETE. = +25 C, As an IRM. IF = MHz. Frequency Range, RF GHz. Frequency Range, LO

Silicon Drift Detectors for the NLC

A new Scintillating Fibre Tracker for LHCb experiment

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

HAPD and Electronics Updates

Parameter Min. Typ. Max. Min. Typ. Max. Units

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Parameter Min. Typ. Max. Min. Typ. Max. Units

CBC2: X-ray Irradiation Results

SCT Activities. Nick Bedford, Mateusz Dyndal, Alexander Madsen, Edoardo Rossi, Christian Sander. DESY ATLAS Weekly Meeting 03. Jun.

LHC Beam Instrumentation Further Discussion

The Cornell/Purdue TPC

Monolithic Thin Pixel Upgrade Testing Update. Gary S. Varner, Marlon Barbero and Fang Fang UH Belle Meeting, April 16 th 2004

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Application Note AN SupIRBuck MCM Power Quad Flat No-lead (PQFN) Inspection Application Note

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Compact Size Perfect for rack mount router and other applications with space limitations.

Front End Electronics

Pixel Detector Control System

Addressing 80 µm pitch Cu Pillar Bump Wafer probing: Technoprobe TPEG MEMS solution

SciFi A Large Scintillating Fibre Tracker for LHCb

R&D on high performance RPC for the ATLAS Phase-II upgrade

Integrated Circuit for Musical Instrument Tuners

AMP DISPLAY INC. SPECIFICATIONS AMP DISPLAY INC 9856 SIXTH STREET RANCHO CUCAMONGA CA TEL: FAX:

Optimizing BNC PCB Footprint Designs for Digital Video Equipment

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

Note on the preliminary organisation for the design, fabrication and test of a prototype double-sided ladder equipped with MAPS

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

INSTRUMENT CATHODE-RAY TUBE

Review of the CMS muon detector system

MIL-STD-883H. b. Radiographic film: Very fine grain industrial X-ray film grade, either single or double emulsion.

Test ofatlas SCT barrel modules with Nd:YAG laser

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Local Trigger Electronics for the CMS Drift Tubes Muon Detector

CCD 143A 2048-Element High Speed Linear Image Sensor

SILICON SOLAR MODULE VISUAL INSPECTION GUIDE

LW10-T600. P10 Led Wall Display

SPECIAL SPECIFICATION 8311 LED Countdown Pedestrian Signal Module

Data Sheet. AMMC GHz Image Reject Mixer. Description. Features. Applications. Absolute Maximum Ratings [1]

Mechanical aspects, FEA validation and geometry optimization

CGEM-IT project update

Features. LO = +13 dbm, IF = 1 GHz Parameter. Units Min. Typ. Max. Frequency Range, RF & LO GHz Frequency Range, IF DC - 8 GHz

Silicon PhotoMultiplier Kits

CCD220 Back Illuminated L3Vision Sensor Electron Multiplying Adaptive Optics CCD

Drift Tubes as Muon Detectors for ILC

APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS

High aspect ratio deep RIE for novel 3D radiation sensors in high energy physics applications

HDMI Demystified April 2011

SLHC tracker upgrade: challenges and strategies in ATLAS

Progress Update FDC Prototype Test Stand Development Upcoming Work

Report from the Tracking and Vertexing Group:

SmartSwitch TM. Wide View LCD 36 x 24 Pushbutton DISTINCTIVE CHARACTERISTICS PART NUMBER & DESCRIPTION

MAURICE TE PLATE EUROPEAN SPACE AGENCY ESA-ESTEC

ADA-4789 Data Sheet Description Features Specifications Package Marking and Pin Connections 4GX Applications

A High-Speed CMOS Image Sensor with Column-Parallel Single Capacitor CDSs and Single-slope ADCs

NT Output LCD Segment/Common Driver NT7701. Features. General Description. Pin Configuration 1 V1.0

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

Transcription:

Silicon Microstrip Detectors for the ATLAS SCT D. Robinson, Cavendish Laboratory for the ATLAS SCT 5th International Conference on Large Scale Applications and Radiation Hardness of Semiconductor Detectors Firenze 4-6th July 21 The ATLAS SCT Sensor Design and Specifications Sensor Development - prototype to production Production Schedule & QA Strategy Quality Control during Production Summary This talk is available as a PDF file from www.hep.phy.cam.ac.uk/silicon

The ATLAS SemiConductor Tracker The SCT comprises 4 barrel layers and 9 end-cap wheels on each side, incorporating a total of ~6m 2 of silicon. The barrel region uses ~16 sensors with rectangular geometry, and the end-cap wheels use ~87 wedge shape sensors. Cross-Section through right side of ATLAS Inner Detector

Barrel Module Wedge module

Barrel Sensor Design Hamamatsu barrel 64 x 63.6mm (active area 62 x 61.6mm) x 285µm 768 AC-coupled strips at 8µm pitch (+2 dummies) Bias resistors at one end Reach-through protection 5-1µm implant-to-bias rail Strip metal width / Implant width = 16-22 / 16-2 µm HV contact: metallised non-passivated n-implant on back, also front contacts to edge-implants for pre-irradiation QA Optimised edge termination (manufacturer-dependant)

Wedge Sensor Design Hamamatsu W12 Five geometries: W12, W21&W22, W31&W32 Length(mm) Outer W idth(mm) Inner W idth(mm) Pitch(µrad) W12 61.6 55.488 45.735 27 W21 65.85 66.13 55.734 27 W22 54.435 74.847 66.152 27 W31 65.54 64.636 56.475 161.5 W32 57.515 71.814 64.653 161.5

Manufacturers Following the process of qualification of their sensors, and competitive tendering, 3 companies were awarded contracts to supply the SCT microstrip sensors. Hamamatsu CiS Sintef (*) Contribution: 79% 17% 4% Sensor types: All Wedges only Barrels only It is not realistic to ask different manufacturers to fabricate sensors from a common design template because sensors from different manufacturers are fabricated using their own commercially-confident design rules and processing techniques. Therefore detailed design issues and choice of substrate are at the discretion of each manufacturer. However, for people building ATLAS SCT modules, the sensors look identical (ie same overall geometries, and locations of bond pads etc) (*) At the time of this conference, the contribution from Sintef is subject to on-going qualification tests

Differences between Manufacturers Hamamatsu CiS Sintef Substate Orientation: <111> <111> <1> Oxygenation: None W12 only(*) None Bias Resistors: Polysilicon Implant Polysilicon Edge Design: Single Guard 14-multiguard 11-multiguard Strip Dielectric: Composite stucture, manufacturer-dependent Corner Detail - Sintef Barrel Implant resistors - CiS Wedge (*) at the time of this presentation, the contribution from oxygenated CiS W12 sensors are still subject to qualification tests

Acceptance Criteria - Pre-Irradiation Characteristics Total leakage current at 2 o C: <6µA@15V and <2µA@35V Leakage current stability: to increase by no more than 2µA @15V in dry air over 24 hours Depletion Voltage < 15V R bias = 1.25 +/-.75 MΩ C coupling >= 2 pf/cm @ 1kHz C interstrip < 1.1pF/cm @ 1kHz @ 15V bias R interstrip >2xR bias at operating voltage Strip metal resistance <15Ω/cm Strip quality: a mean of >99% good readout strips per detector in each delivery batch, with no detector having less than 98% good strips. A strip is counted as defective if any of the following conditions apply: - An electrical short through the dielectric with 1V applied between the metal and substrate - Metal break or metal short between neighbours - Implant break or implant short between neighbours - Implant strip connection via resistor to bias rail broken

Acceptance Criteria - Post-Irradiation Characteristics During Irradiation Detector leakage current should increase in a stable and monotonic fashion After 3x1 14 p.cm -2 and 7 days anneal at 25 o C: Total leakage current <25µA up to 45V @ -18 o C Leakage Current stability: tovarybynomorethan3%in24 hours at 35V at -1 o C Strip defects: Number of strip defects (dielectric & metal) within pre-irradiation acceptance level R bias to remain within pre-irradiation limits R interstrip >2xR bias Charge collection: Maximum operating voltage for >9% of maximum achievable charge : 35V (checked with SCT128A analogue readout at 4MHz) Microdischarge: must be <5% increase in measured noise on any channel due to microdischarge when raising detector bias from 3V to 4V (checked with readout electronics running at 4MHz)

Sensor Development from Prototype to Production 1995-1999 Prototyping, including n-on-n Early 1999 Formal qualification of manufacturer Late 1999 Competitive tendering, contracts awarded Jan-Apr 2 PreSeries Production Jan 21 - late 22 Full scale production (in progress)

Sensor Qualification Interested manufacturers were invited to supply several of their optimised prototype sensors that should meet ATLAS specifications. The prototypes were evaluated extensively by ATLAS both before and after irradiation to ~3x1 14 p.cm -2. Only those manufacturers that had supplied several prototypes (nominally 1) with identical processing that gave consistent characteristics and were within all ATLAS specifications before and after irradiation were considered to be qualified. Four companies qualified their sensors, and after competitive tendering three of these companies (Hamamatsu, CiS, Sintef) were awarded contracts to supply the SCT sensors. Before full scale production, companies were required to deliver a preseries production (~5% of their total order)

PreSeries Production (Jan-April 2) Manufacturers were initially required to supply a preseries production, which comprised ~5% of their total delivery. The preseries was used to demonstrate: that the quality of the produced sensors will be maintained, with characteristics consistent with the qualified sensors. the ability to comply with delivery schedules the ability of both the manufacturer and ATLAS to effectively implement the QA procedures compatibility of QA data between the manufacturer and different ATLAS institutes the effectiveness of packaging, labelling, transportation and other procedural and QA issues A Production Readiness Review in August 2 approved the release of funds for the full series production.

4. Series Production (Jan 21 to late 22)... Is currently underway! Manufacturers are contractually obliged to deliver detectors in regular monthly shipments, distributed to the 7 modulebuilding clusters in ATLAS: CE: Freiburg, MPI, Nikhef, Prague, Potvino UK-V: Glasgow, Lancaster, Liverpool, Manchester, RAL, Sheffield, Valencia CS: Australia, CERN, Cracow, Geneva, Llubljana, MSU, Prague, MPI Nordic: Bergen, Oslo, Uppsala Japan:Hiroshima, Tsukuba/KEK, Kyoto edu, Okayama USA:LBL,UCSC UK-B: Birmingham, Cambridge, QMW,RAL red indicates QA institute Each of the module-building clusters has one or two institutes that receives the detectors and performs all the QA. The receiving ATLAS institute has three months to perform all QA tests before payment is due. Eg: Schedule at Cambridge: total delivery: 23 Hamamatsu barrels monthly batch size: 12 Jan 21 to August 22.

Acceptance Criteria - Mechanical Properties Not all mechanical properties are easily quantifiable, and some may be quantified somewhat arbitrarily. However, it is important to state all possible problems and to set reasonable limits where possible to ensure that manufacturers are contractually obliged to take back detectors that are mechanically defective Quality of cut edges: Edge chipping to be avoided, no chips or cracks to extend inwards by > 5µm Damage and Defects: Device free from scratches and other defects that ATLAS judges could compromise the detector performance during the lifetime of the experiment. The criteria were mainly established in collaboration with the manufacturer during the pre-series production, and may continue to evolve. Thickness: 285 +/- 15µm Uniformity of thickness: 1µm Flatness: Sensors must be flat to 2µm when unstressed Mask alignment tolerance: <3µm misalignment Bond Pads: Metal quality, adhesion and bond pad strength to be such as to allow successful uniform bonding to all readout strips using standard bonding techniques. Alignment fiducials: Must be visible

The Manufacturer QA Strategy Following the process of qualification of a detector from a particular manufacturer, it is the responsibility of the manufacturer to ensure no changes in processing occur during production that may modify: any parameters relevant to ATLAS specifications any pre- and post-irradiation electrical behaviour from that observed during the qualification program. ATLAS As consistency of processing is ensured, the role of ATLAS is mainly that of a visual examination and IV measurement on every detector as a basic check on quality. However, on a subset of detectors (~1%), an extensive evaluation of detector characteristics is performed as a check on processing consistency and as a verification of the manufacturers tests. Furthermore, samples of detectors (<1%) will be regularly irradiated throughout production to ensure that the post-irradiation behaviour of the qualified detectors is being maintained.

Quality Control by the Manufacturer The manufacturer is expected to perform sufficient checks to ensure consistency of processing and to maintain all electrical parameters within ATLAS specifications. In addition, the manufacturer is expected to perform the following test measurements on every detector, and to supply the results to ATLAS: IV to 35V DepletionVoltage Determine strip dielectric shorts with 1V across across the dielectric (and must ground the strip metals afterwards!) Determine strip metal breaks Determine strip metal shorts to neighbours

Quality Control Procedures by ATLAS Compulsory tests on every sensor (Detector placed on probestation chuck) - Visual examination (~8 mins) - IV scan to 5V Tests on a subsample (~1%) (Detector mounted into frame) - Depletion - Full Strip Test - Metal Resistance - (interstrip capacitance) Tests on irradiated sensors (<1%) (after 3x1 14 p.cm -2 and 7 days anneal at 25 o C) - IV scan to 5V - Plateau in Signal vs bias (analogue r/o) - Strip noise distribution (binary/analogue r/o)

Visual Inspections Full sensor area scanned under a microscope (automated probestation). Sensor must be free from gross defects and scratches and edge chips must not exceed 5µm. What is a gross defect? Requires judgement by operator, and agreement with manufacturer: REJECT ACCEPT Rear Edge Chip REJECT Debris in packaging from edge chipping poses danger

Visual Inspections What about general visual curiosities? Almost certainly harmless, but if frequently occurs (eg observed several times in a batch of ~1 sensors), choose as candidate for irradiation:

Leakage Current Tests Measure from to 5V in 1V steps, reject if any of the following apply: I>6µA@15V I>2µA@35V I(ATLAS-manufacturer) > 2µA@15V or 4µA@35V Fails I testonly NB: Hamamatsu agreed I rejection criteria to be tightened to 1µA

For more extensive tests (on ~1% of total sample), detectors are held and bonded into a frame to minimise risk of damage by excessive handling Sensor held in by very light spring pressure between 3 delrin clamps Delrin support block Bias connections, bonded to bias rail (gnd) and edge implant (HV)

Leakage Current Stability Test at Cambridge 5 detectors on support blocks, with bias connections wire bonded out to soldered leads. Environment Chamber

Full Strip Test Setup at Cambridge Support Block, held down by chuck vacuum Probestation Chuck Wire bonds to bias connections

Full Strip Test With the sensor partially biassed (to ~5% of full depletion voltage), step through every strip to probe the strip metal. For every strip, apply 1V across strip dielectric to determine robustness of dielectric, then return strip metal to ground and model CR in series on the measured impendance @1 Hz between strip metal and bias rail C=C coupling R=R bias Sensitive to any strip defect, and any general processing defect that may effect operation of sensor, and yields the bias resistance and coupling capacitance for every strip.

Detection of implant breaks, strip metal defects Metal short Implant break

Detection of broken resistors

Detection of Resistor Process Defect

Irradiations Samples of detectors will continue to be irradiated throughout production, to ensure that the post-irradiation performance observed from qualified detectors is being maintained. The detectors are irradiated with 24 GeV/c protons to 3x1 14 p.cm -2 at the T7 irradiation facility at the PS. During irradiation, the detectors are chilled in nitrogen to -8 o C, and biased at 1V with all strip metals grounded. The irradiation takes typically 6-1 days, and following irradiation the detectors are annealed for 7 days at 25 o C to bring them to the minimum of the anneal point.

Post-Irradiation Leakage Currents Qualification W12 detectors from Hamamatsu Early prototypes from non-qualified manufacturer, showing current increase from 4V due to microdischarge.

Measuring Strip Noise Distribution using rebondable modules

Detail of wirebonding scheme of rebondable binary module Effective strip length connected to chip: 6cm 12cm 6cm 12cm

Strip Noise Distributions Binary Readout (LBIC/CDP) at 4MHz 4 Annealed Ham98-3 (ATLAS97) after 2.8x1 14 p.cm -2. 12cm Strips. Noise (electrons) vs Channel No. Strip Noise Histogram Unbonded hybrid 4 Annealed HamB15 (ATLAS98) after 3x1 14 p.cm -2. Chip 1, 6cm Strips. Noise (electrons) vs Channel No. Strip Noise Histogram Unbonded hybrid 4 4 2 2 2 2 4 2 15 2 25 4 25V 2 1 2 3 4 5-12 degc -18 degc 4 2 15 2 25 4 2V 2 1 2 3 4 5-12 degc -18 degc 4 15 2 25 4 3V 1 2 3 4 5 4 15 2 25 4 3V 1 2 3 4 5 2 2 2 2 4 15 2 25 4 35V 1 2 3 4 5 4 15 2 25 4 4V 1 2 3 4 5 2 2 2 2 4 15 2 25 1 1 2 3 4 5 4 15 2 25 4 5V 1 2 3 4 5 2 4V 5 2 2 15 2 25 1 2 3 4 5 Early prototype, showing widespread microdischarge with increase bias 15 2 25 1 2 3 4 5 Detector from qualification batch, no signs of microsdischarge.

Charge Collection, using SCT128A B2 22292141 after 3x1 14 p.cm -2 and 7days anneal at 25C Data taken at -18C by SCT128A.1 bonded to 12cm strips Signal (ADC counts) Noise (ADC counts) 15 1 5 1 2 3 4 5 6 Bias (V) Noise vs Bias 15 1 5 Either 6cm or 12cm portion of the sensor is bonded to a SCT128A analogue chip running at 4MHz. Charge measurements are performed using a Ru 16 β-source Signal/Noise 1 2 3 4 5 6 Bias (V) Signal/Noise vs Bias 15 1 5 1 2 3 4 5 6 Bias (V)

Summary The quality and robustness after irradiation of the SCT microstrip sensors has been demonstrated in a qualification program The QA strategy defined by ATLAS is that production sensors must use identical masks and processing as qualified sensors. QC procedures are now well established to check basic quality and to monitor the characteristics of production sensors in comparison to qualified sensors. Production is underway and (mostly) on schedule for Hamamatsu and CiS. Some further qualification tests are in progress for Sintef sensors and CiS oxygenated W12s. QC by the receiving institute is essential, particularly in the early stages of mass production Eg: - severe edge chipping on rear side on early deliveries due to misinterpretation of specifications - some subtle but severe processing abnormalities passed unnoticed by the manufacturer - manufacturer is completely reliant on ATLAS for feedback on post-irradiation robustness