Electronic 7 User Operating Instructions

Similar documents
ServicePlus S17R Series 2 User Operating Instructions

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

ChannelPlus H17XL Series 2 User Operating Instructions

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

1. General Information:

Digital Economy Seven Programmer

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

1 Channel Multi-Purpose Programmer User Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

7 Day Digital Programmer

7 Day Digital Programmer 3 Channel Surface Mount

Programmable Room Thermostat With RF

7 Day Digital Time Switch

Digital Time Switch. Installation & Operating Instructions

USER & ENGINEER INSTRUCTION MANUAL

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ST9100C User Guide. Features

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

7 Day Digital Light Switch with Optional Dusk Start

24Hour/7Day Electronic Timeswitch

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Waterline Room Controller - Type WLCT3

16 Amp Electronic 24 Hour/7 Day Time Controller

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Ducasa Digital Programmer

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Inserting the batteries. Basic settings of the remote control

APOLO DC B Electric Thermal Radiators

TDDFM14 OWNER S MANUAL

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Aspect 2 Circuit Digital Scene Control

EDMI Mk 7C Electricity Meter User Guide to LCD Screen Displays

Honeywell. Manual DFRC. RF Remote Control Decorative Fire

QUADRANT DVB-T Modulator USER GUIDE. Quadrant DVB A N T E N N A I R. Copyright 2012 Antennair Limited, Neo House, Shaw Road, OLDHAM OL1 4AW. Issue 1.

Analog/digital watch Multi frequency reception, 4 digit LCD, 3 hands. Preliminary Specification

MP-7424 Football Scoreboard with MP5000 Console

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Comfort System T-32-P Universal Thermostat. Operation Manual

XTM72 Exerciser Timer Module

Philips LightMaster. KNX Timeclock Installation and Operation Manual

American DJ. Show Designer. Software Revision 2.08

ST625TX Digital Room Thermostat

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

OWL micro+ WIRELESS ELECTRICITY MONITOR

WiFi Controlled Fused Spur Time Switch

3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

HD Digital Set-Top Box Quick Start Guide

Evolution Digital HD Set-Top Box Important Safety Instructions

Single Station Waterproof Timer

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

Scoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control

ZoneTouch V2 Zone Control System User Manual

Operating instructions. Universal timer switch display

The Dangerous Music D-Box user s operating guide

INSTRUCTION MANUAL DAFM2

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

SwiftMix Automation Safety

To identify the type of meter you have, look at the descriptions below. To find out how to read your meter, select the relevant option.

User s Manual. SmarTV

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

Hip Hop Activity Box. Instruction Manual. Hip Hop Activity Box 22875, October 2018 Copyright ROMPA Ltd

Quick Start Guide. Large-capacity Automatic Pet Feeder

Third Edition. Product instructions (English version) LCD TEST TOOL. Instructions. (All rights reserved, pirates must investigate) 2015/08/

Xtreme Power Systems RFU. Installation And Usage Manual. Firmware v1.1. Manual v1.1. Revision Date: June 5 th, 2014

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Operations. BCU Operator Display BMTW-SVU02C-EN

SceneStyle2 User Guide

Tube Rotator. User Guide. Version 1.2

FD Trinitron Colour Television

FiliBuster. User Manual

Integrated Remote Commander

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

NMS ETA TM Stereo Advanced Digital TV Set-top Box

Registers type ILR7XX and ILR7XXT

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

Scoreboard Operator s Instructions MPCX Volleyball Control

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

DIGITAL TIMER - MODES- rev. 5.5

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Instructions Manual

Operation Manual. Model MCS350. Modular Communication System. Document No (01)

C-net WIND. User s Guide

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

2.0 Wall Mount TV Soundbar Instruction Manual

Radio Thermostat Clock

ZVOX AccuVoice TV Speaker Model AV203

Transcription:

Electronic 7 User Operating Instructions The Horstmann Electronic 7 Water Heater Controller has been especially developed to control the immersion heater as economically and conveniently as possible. During the night, water in the tank will be heated by cheap night-rate electricity, ensuring a tank of hot water is available for the morning. Depending on the size of the tank and usage of hot water, this will usually last a day; however, if required, more hot water can be heated at any time by using the boost button which switches on the immersion heater for one hour. Alternatively if it is known that extra hot water will be required every day, the boost element (in the tank) can be programmed so that it will heat only a small part of your tank. This is normally the upper element in the tank and can be programmed to come on once each day at a set time. Some tariffs offer additional cheaper electricity periods during the day time; the Electronic 7 has extra off peak switching periods available to accommodate this. 1

The Electronic 7 - an overview The simple instructions in this user guide are designed to help you with programming and operation of the unit. 1 2 TIMED RUN CLOCK SUMMER AM WINTER BOOST PROGRAMME OFF PEAK PROGRAMME TIMED BOOST SET ST 3 MINUS PLUS SELECT BO O ISOLATE MAINS BEFORE OPENING OR SERVICING IMMERSION HEATER(S) OFF SWITCHED OUTPUT TIMED 4 ELECTRONIC 7 LCD Display: The LCD display allows you to view the current time and set programme times. Indicators: Illuminated indicators give a visual feedback, indicating the status of the programmes or boost operation. Key: 1 - Timed display indicator 2 - LCD Display 3 - Boost Button 4 - Switched Output control Manual Boost: To use the manual boost, press the BOOST button on the unit which will then boost your tank for 1 hour and then switch off. THE BOOST WILL NOT OPERATE OR WILL BE CANCELLED DURING TIMED HEATING PERIODS 2

Programme Security Lock If the 4 black squares are showing in the display then this indicates that the automatic programme of switching times has been locked on installation and cannot be altered by the user. This will ensure that the programme stays matched to any preferential tariffs which should mean that your water is heated as economically as possible. The manual boost button will still be operative allowing one hour of extra hot water each time the boost is operated. TIMED RUN CLOCK SUMMER AM WINTER BOOST PROGRAMME OFF PEAK PROGRAMME TIMED BOOST Switched Output In the OFF position the electrical supply to the immersion heater(s) is disconnected even though the clock, display and indicator lights continue to operate. In the TIMED position the over-night immersion heater will be switched on and off at the programmed switch-time settings, at other times the boost facility is available. OFF SWITCHED OUTPUT TIMED 3

Time Display The Electronic 7 is fitted with an automatic clock that is pre-set on manufacture and should not normally require any adjustments by the user. The summer / winter setting is automatically selected and will automatically change. This is indicated on the screen next to the appropriate setting. Therefore no adjustment is needed to be made by the user for the summer / winter clock change. Should a minor correction to the clock be necessary or if the unit has been reset then see the section on Setting Time of Day. On installation the installer will have selected whether the Electronic 7 will switch at GMT times throughout the year or whether the timings need to alter as the clocks change. For example: GMT/BST Switching time will be changed by one hour. In the GMT/BST mode the clock display will match the actual switching time. GMT ONLY Switching will always take place at GMT times (summer and winter). Although the clock display will show the correct time. Setting Time of Day Press the green SET button until the indicator on the left hand side of the screen is next to CLOCK. Adjust the hour by pressing the white MINUS or PLUS buttons. Once you are happy with the hour selected, press the blue SELECT button. The minutes will now flash. To adjust the minutes you need to once again press the MINUS or PLUS buttons. Once you are happy with the time selected, press the blue SELECT button, this will now take it back to the RUN position on the left hand side of the screen. 4

Setting Off-Peak Heating Periods The time hour will now flash for the 1st on time, this can be adjusted by pressing the MINUS and PLUS buttons. Once you are happy with the hour you have selected press the SELECT button. Press the green SET button until the indicator on the left hand side of the screen is next to OFF PEAK PROGRAMME The hour will be flashing on the 2nd on time, if this is not required then press the green SET button which will take you back to the main screen. However, if you require any further off-peak periods then simply repeat the same steps as above. This will then make the minutes flash, which can be adjusted by pressing the MINUS and PLUS buttons as required. Once you are happy with the minutes, press the SELECT button to take you to the 1st off time Use the MINUS and PLUS buttons to adjust the hour. When you are happy with the hour selected then press the SELECT button which shall now take you to the minutes. Press the MINUS and PLUS buttons to SELECT the minutes you require and once you are happy with the minutes press the SELECT button. Resetting the Unit Sometimes electronic equipment can become scrambled or frozen. To overcome this you should reset the unit. This can be achieved by holding down BOOST, MINUS, PLUS & SELECT simultaneously. The unit will now revert back to pre-set factory default off peak times and the current time will show the time as it was at the time of re-set. The hour will be flashing and should be adjusted as detailed in the section Setting the time of day. Default Time Settings Default Times 1st ON 2:15am 1st OFF 7:15am 2nd ON 12:00am 2nd OFF 12:00am 3rd ON 12:00am 3rd OFF 12:00am After re-setting the unit the off-peak heating times will revert back to the default factory settings, these are shown above, however if you wish to change these times please proceed as instructed in the Setting Off-Peak Heating Periods above. 5

Programmed Boost This setting is not recommended for single element installations and is normally only used with twin or dual immersion heaters. With the TIMED BOOST indicator on the right hand side of the screen selected the boost, or upper element within the tank will heat up at the same time automatically everyday. This can be turned on and off by pressing the SELECT button. To Set Boost Programme Press the green SET button until the indicator on the left hand side of the screen is next to BOOST PROGRAMME. The time hour will now flash for the on time, this can be adjusted by pressing the MINUS and PLUS buttons. Once you are happy with the hour you have selected, press the "SELECT" button. This will then make the minutes flash, which can be adjusted by pressing the "MINUS" and "PLUS" buttons as required. Press the MINUS and PLUS buttons to SELECT the minutes you require and once you are happy with the minutes press the SELECT button which will take you back to the RUN position. An indicator should be shown on the right hand side of the screen next to TIMED BOOST, if there isn t then you need to press the SELECT button. Once you are happy with the minutes, press the SELECT button to take you to the off time. Use the MINUS and PLUS buttons to adjust the hour. When you are happy with the hour selected, press the SELECT button which shall now take you to the minutes. Battery Reserve The Electronic 7 is designed to be permanently connected to the mains electricity supply. This unit has a non-rechargeable long-life battery which will maintain the display and switch time settings for approximately 2 years with the mains electricity supply disconnected. This should be sufficient to cover all power interruptions during the life of the unit. Neon Indicators There are two neon indicators on this unit, one to indicate when the boost is active and the other to indicate when the timed off-peak is active. With the SWITCHED OUTPUT SWITCH in the OFF position the indicators lights will still illuminate but no electrical switching will take place. 6

Service and Repair The Horstmann Electronic 7 is not user serviceable, so please do not try to dismantle the unit. In the unlikely event of a fault developing try resetting the unit, which is in this manual under RESETTING THE UNIT. If this fails to resolve the problem then please contact your installer or a local heating engineer or a qualified electrician. Questions (Q) There is no display on the screen? (A) Ensure there is mains supply getting to the unit and that the battery switch on the rear of the unit is in either the GMT/BST or GMT ONLY position. (Q) The display has become frozen? (A) This could be due to local electrical interference. Using the RESET procedure in this manual may rectify the fault. (Q) The neon indicator will illuminate but there is no hot water? (A) Ensure the SWITCHED OUTPUT switch is in the TIMED position. If this still fails to rectify the problem please contact a local heating engineer or a qualified electrician. (Q) How do I change the back-up battery? (A) You can t as it is an integral part of the unit, and therefore would invalidate your guarantee if you dismantled the unit. (Q) I want to adjust my off-peak times, how is this achieved? (A) Please go to SETTING OFF PEAK PERIODS in this manual. (Q) What does the indicator next to the word TIMED BOOST mean? (A) If there is an indicator next to this word on the right hand side of the screen, then this means the boost programme is selected. Please see BOOST PROGRAMME in this manual. (Q) Why are there 4 black squares showing in the display? (A) The security feature has been engaged on installation to stop any programme settings being altered by the user. (Q) I cannot alter the programme times set into the Electronic 7. (A) The programme security feature may have been engaged. This is shown by 4 black squares showing in the display. 7

South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP t: +44 117 978 8700 e: sales@horstmann.co.uk www.horstmann.co.uk Part Number P83079 Issue 3