ITS specification Lane control signal supply and installation (ITS-04-02)

Similar documents
INTERIM ADVICE NOTE 109/08. Advice Regarding the Motorway Signal Mark 4 (MS4)

Special Provision No. 685S07 February This Special Provision refers to the following standards, specifications, or publications:

Drop Passives: Splitters, Couplers and Power Inserters

ROAD COMMISSION FOR OAKLAND COUNTY SPECIAL PROVISION FOR LIGHT EMITTING DIODE (LED) VEHICLE TRAFFIC SIGNALS

A.D. Engineering International Pty Ltd - Product Range

AMERICAN NATIONAL STANDARD

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

MONDO VIDEOSCREENS AND LED SOLUTIONS

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

SPECIAL SPECIFICATION 2344 TMC Support Equipment

September 28, 2018 CITY OF BERKELEY JOHN MUIR SCHOOL CROSSING IMPROVEMENTS SPECIFICATION NO C ADDENDUM NO. 2

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

AMERICAN NATIONAL STANDARD

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

ENGINEERING COMMITTEE

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Colour Explosion Proof Video Camera USER MANUAL VID-C

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

IndyGo Facility Upgrades Project 35671EE

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

AU OPTRONICS CORPORATION. Specification for Approval. INCOMING INSPECTION STANDARD FOR A201SN02 TFT-LCD MODULES (A- Grade)

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Signal Sighting Standard

SURFACE MOUNT LED LAMP 0603 (0.8 mm Height)

Kingbright. L-7104YD-12V T-1 (3mm) Solid State Lamp DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1210

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

CONTENTS. Table of Figures

OM2000N INSTALLATION MANUAL

MATERIAL SPECIFICATION FOR SIGNAL HEADS

Lineside Signal Aspect and Indication Requirements

SURFACE MOUNT LED LAMP STANDARD BRIGHT PLCC-2

LED modules for illuminated signs Opto Semiconductors

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

LMT X1 - a 12.1" VHB

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount)

INSTRUMENT CATHODE-RAY TUBE

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Specification for F Connector, Male, Pin Type

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Special Provision No. 685S01 February 2016

Reference Manual. Notes 9/16 Series H

Photovoltaic Module Installation Manual (IEC)

S195AVGC-2BM 1.6x0.8mm, Red & Yellow Green LED Surface Mount Bi-Color Chip LED Indicator

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

Guidelines for Specification of LED Lighting Products 2010

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

HighBand 25. TrueNet Category 6 Solutions

Harvatek International 2.0 5x7 Dot Matrix Display HCD-88442

Photovoltaic Module Installation Manual (IEC)

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

CM-S23349SV. Vari-Focal IR Bullet Camera

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

Features 1.0 MIN. CATHODE LEAD. Sq Typ 0.50 ±0.10

Outdoor IR Audio Camera

WP36BHD T-1 (3mm) Blinking LED Lamp

CHROMAPOWERLINE 100 DATASHEET

SURFACE MOUNT LED LAMP FULL COLOR 1210

Bulb Down Light Decorative Light

P XGA TFT Monitor. User s Manual

CM-S38901SV TVL IR Long Range camera

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Special Specification 6293 Adaptive Traffic Signal Control System

RESOLUTION MSC.95(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR DAYLIGHT SIGNALLING LAMPS

TRF STEP-DOWN TRANSFORMER USER MANUAL

Don t let Potential Customers pass you by!

Winmate Communication INC.

THE CABLE TRAY SYSTEM

PLCC Series W Horticulture Series

SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Altman Lighting Spectra Cyc 50 Specification

ENGINEERING COMMITTEE

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

Roof-mounted Blue e+ cooling unit Integration solution VX25

INSTRUMENT CATHODE-RAY TUBE

WAH WANG HOLDINGS (HONG KONG) CO., LTD.

LCD Thermometer / Clock S No. 1253

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

OWNER'S MANUAL MYCRO SUB

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

PLCC Series EMC 3030 Single color

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

Transcription:

ITS specification Lane control signal supply and installation (ITS-04-02) NZ Transport Agency Effective from September 2011

Copyright information This publication is copyright NZ Transport Agency (NZTA). Material in it may be reproduced for personal or inhouse use without formal permission or charge, provided suitable acknowledgement is made to this publication and the NZTA as the source. Requests and enquiries about the reproduction of material in this publication for any other purpose should be made to: NZ Transport Agency Private Bag 6995 Wellington 6141 The permission to reproduce material in this publication does not extend to any material for which the copyright is identified as being held by a third party. Authorisation to reproduce material belonging to a third party must be obtained from the copyright holder(s) concerned. Disclaimer The NZTA has endeavoured to ensure material in this document is technically accurate and reflects legal requirements. However, the document does not override governing legislation. The NZTA does not accept liability for any consequences arising from the use of this document. If the user of this document is unsure whether the material is correct, they should refer directly to the relevant legislation and contact the NZTA. More information Published September 2011 If you have further queries, call our contact centre on 0800 699 000 or write to us: NZ Transport Agency Private Bag 6995 Wellington 6141 This document is available on the NZTA s website at www.nzta.govt.nz.

Page i Document management plan 1) Purpose The purpose of this document is to specify the general requirements for the supply and installation of Lane Control Signals. 2) Document information Document name Document number Document status Document availability ITS specification: Lane control signal supply and installation ITS-04-02 Final This document is located in electronic form on the NZ Transport Agency s website at www.nzta.govt.nz. Document author Waterview ITS Requirements Working Group: Jamie French Jamie.French@beca.com (09) 300 9340 Tom Harris Tom.Harris@opus.co.nz (09) 355 9542 Document owner Henry Pretorius 3) Key words ITS Lane Control Signal Supply and Installation.

Page ii Record of amendments Amendment number Section amended Description of change Updated by Effective date 0 All ITS Draft Specifications Issue TLH 20/9/2010

Page iii Contents Document management plan Record of amendments i ii 1.0 Lane control system 1 1.1 Scope 1 1.2 Advisory speed lane signal units 1 1.3 Mandatory speed lane signal units 1 2.0 Lane control signals 2 2.1 General 2 2.2 Lane signal unit requirements 2 2.2.1 Symbol display 2 2.2.2 Text display 2 2.2.3 Optical performance 2 2.2.4 Viewing angle 3 2.2.5 LED s 3 2.2.6 Display intensity 3 2.2.7 Display colour 3 2.2.8 Display maintenance access 4 2.3 Lane signal unit enclosure and mounting 4 2.3.1 General 4 2.3.2 Materials 4 2.3.3 Doors 5 2.3.4 Sign mounting 5 2.3.5 Construction requirements 5 2.4 Control/data interface requirements 5 2.4.1 Sign control 5 2.4.2 Status feedback 5 2.4.3 Data transmission 6 2.5 Electrical requirements 6 2.6 Testing requirements 6 2.7 Maintenance requirements 7

Page 1 1.0 Lane control system 1.1 Scope This section sets out the requirements for the supply, testing, installation and commissioning of the lane control system (LCS). Each LCS field installation (LFI) shall provide specific, localised lane availability status and advisory or regulatory speed information to motorists, using multiple display devices, and shall comprise the following elements: a. Lane signalling units (LSU), capable of displaying a limited set of lane use and speed advisory messages complemented by amber flashers; b. Overhead gantry sign support structure, which positions the LSUs above the motorway lanes as specified in the NZ Transport Agency s (NZTA) ITS specification: Lane control system civil and structural works (ITS-04-01); c. Ancillary control and communications equipment. The LSU shall each be capable of displaying a fixed limited message set of speed indications and graphic lane control symbols. LCSs require either advisory speed LSUs or Mandatory speed LSUs. 1.2 Advisory speed lane signal units Advisory speed LSUs shall: a. Display speed indications at 10km/h increments from 10 to 100 inclusive using a standard 5 x 7 pixel matrix; b. Each character shall have a minimum height of 450 mm; c. Display move left and right arrows, divert left and right arrows and a lane closed ("X") symbol; d. Aspects shall be amber with the exception of the lane closed "X", which shall be displayed in red; e. Utilise proportional spacing to separate each character displayed; f. Have 150mm diameter amber flashers located at each corner of each LSU display; g. Have a 100mm wide bezel surrounding the flashers. Note that preference is given to utilisation of the same or similar hardware for advisory speed LSUs as that already installed. 1.3 Mandatory speed lane signal units Mandatory speed LSUs shall: a. Comply with the above requirements for advisory speed LSU s; b. Have a red roundel, comprising of LED elements which can be turned on or off independently of any other displays. This rondel shall surround the speed display and shall be of a size and width to emulate the proportions of a standard static mandatory speed sign; c. Have a 100mm wide bezel surrounding the flashers and the roundel.

Page 2 2.0 Lane control signals 2.1 General For all LCS applications, LED display technology is the de-facto standard for all LCS displays. This technology provides good visibility under most viewing conditions and has low maintenance requirements. Other technologies may be considered subject to specific approval from the NZTA s National Office Network Operations Network Demand staff. Lane Control Signs shall employ light emitting technology, not requiring external or supplementary illumination. Each sign shall display messages comprising any combination of text, numerals and free-format graphics. In general the signs will operate in either a text mode, or in graphics mode. In text mode, the signs shall display text, numerals and standard punctuation marks. In graphics mode, the signs shall be able to display graphics only. Signs shall be of the continuous matrix type. 2.2 Lane signal unit requirements 2.2.1 Symbol display All symbols shall be developed in accordance with the Manual of traffic signs and markings (MOTSAM) and are subject to the approval of the Engineer. Aspects shall be white, or white/yellow with the exception of the lane closed "X", which shall be displayed in red. The display shall be updated in a manner that appears instantaneous. An amber flasher shall be located at each corners of each LSU display (size to match existing LSU s at diameter of 150mm). 2.2.2 Text display Each LSU shall be capable of displaying numerals using a standard 5 x 7 pixel matrix. Each character shall be a minimum of 450mm high. Signs shall utilise proportional spacing to separate each character displayed. Each sign shall be capable of displaying messages comprising any combination of text and numerals, including a limited graphics capability incorporating arrows. A means of flashing complete messages and individual characters or groups of characters within a message shall be provided. The time taken to display an alphanumeric message generated at the local controller shall not exceed 0.5 seconds. Default and fail-safe messages shall be employed. Default and fail-safe messages shall be configurable at the central control computer(s). A blank fail-safe message shall be displayed in the event of a power failure, display character module failure, communications failure or the failure of any other significant component of the control system. 2.2.3 Optical performance The LSU displays shall be clearly legible from any distance between 75m and 300m under normal motorway operating conditions, and from any part of the approaching lanes, including the hard shoulder.

Page 3 The optical performance of all signs shall conform with BS EN 12966-1, Visual Performance as detailed in section 4.2 of the NZTA s Fixed variable message sign design guide (SP/M/026). 2.2.4 Viewing angle The LED elements for LSU s shall have a minimum of fifteen (15) degrees viewing angle. The LED s shall be grouped to form a symmetrical, circular shaped pixel in the display matrix. The luminous intensity of the pixel shall not decrease by more than 50% when viewed at a minimum angle of 15 (7.5 1/2 angle) centered about the optical axis and perpendicular to the surface of the display. The luminance for different pixels shall not vary by more than +/- 20% of the mean output of all the pixels. 2.2.5 LED s The Contractor shall supply evidence that LED s supplied as part of any LSU meet the quality, life expectancy, candela ratings and batch requirements outlined in this document and any referenced external standard. The Contractor shall also supply details of the current rating of the proposed LED s to be used and what actual current they will be driven at to meet the candela requirements of the NZTA for the LSU. LED s used in the LSU shall all be sourced from the same batch / bin to mitigate minor variations in colour. The decrease in luminous intensity of any LED pixel under 24 hour continuous operation shall not exceed 30% after one year and 40% after five years. No LED or group of LED s shall be overdriven or supplied additional current such that the stated LED life expectancy is compromised, to achieve the candela ratings required under BS EN 12966-1. LED s selected shall be highly reliable for the intended application; with a target continuous operating period of five years, the Mean Time Between Failures (MTBF) of a single LED display element shall not be less than 150,000 hours; (a display element is defined as failed when less than 75% of the LED in the display element are operational or when the display element has failed to achieve 75% of the intended output intensity). The LED pixels shall be waterproofed to protect the LED; All soldering of LED s required to form pixels will be of a type that minimises the exposure of the LED s to sudden excess heat and creates a reliable, tested set of connections, (wave soldering combined with component PCB preheating) and meet viewing angle performance levels. 2.2.6 Display intensity Each LCS Field Installation (LFI) Lane Control System shall include no less than two integral light sensors (facing forward and to the rear) to measure the ambient external light conditions from all directions and automatically adjusts the intensity of the LSU displays to a minimum of four different levels. The light sensor system shall ensure that the luminance output of the LSU s is maintained in accordance with the ambient and background light conditions, including direct sunlight and darkness. The controller shall ensure that the intensity of the sign display is unaffected by short fluctuations in ambient light conditions by averaging light sensor readings over a suitable, (60s ± 30s), and configurable period of time. The LSU s shall prove conformance to the minimum luminance under external illumination prescribed in BS EN 12966-1. 2.2.7 Display colour The text and arrow graphic pixels shall display an amber colour using LED s having a nominal wavelength of 590nm.

Page 4 The lane closed ("X") symbol and red roundel pixels shall display a red colour using LED s having a nominal wavelength of 630nm. The colour of LED s shall be uniform across the sign; When measured with the test module fully dimmed on axis and at the horizontal and vertical half angle positions, the colour coordinates shall be within the limits given below (from CIE 1931 Colour Domain). Table 2-1: Display colour 1 2 3 4 Yellow Red X 0.618 0.612 0.564 0.560 Y 0.382 0.382 0.426 0.440 X 0.618 0.612 0.564 0.560 Y 0.382 0.382 0.426 0.440 2.2.8 Display maintenance access Display elements and control equipment shall be readily accessible and removable for maintenance. Removal of display modules shall be undertaken by the loosening of easily accessible screw fixings, or other suitable fastening arrangement, and disconnection of power and control connectors only. The display elements shall be designed in modules to facilitate maintenance and replacement. Failure of operation of a single display element (pixel) shall not require on-site replacement of more than one display module. Failure of a single pixel shall not affect the operation of any other pixels. Pixels and or Pixel mounting blocks shall be modular and easy to swap / replace without requiring any soldering or any other form of heat based bonding to other electrical components as part of the process. During replacement of faulty driver boards or light emitting modules the sign shall remain operational. 2.3 Lane signal unit enclosure and mounting 2.3.1 General The LSU enclosure shall be a black non-reflective corrosion resistant enclosure that shall contain all display elements and driver electronic equipment. Individual LSU control electronic equipment may be housed in a separate enclosure mounted inside the LSC gantry truss. The LSU and individual LSU control enclosures shall be constructed to present a clean, neat appearance. All LSU s and individual LSU controllers shall be fully serviceable from the rear of the enclosure. Sign and individual controller design for replacement, repair, or maintenance activities, shall ensure there is no risk of any element of the sign, enclosure, maintenance materials or tools falling on to the carriageway below. The equipment housed within the LSU and individual LSU controller enclosures shall be protected from moisture, rain, snow, sun radiation, dust, dirt and salt corrosion. The enclosure shall provide a minimum IP65 ingress protection as defined in AS 1939-1990. 2.3.2 Materials The LSU enclosures shall be constructed from sheet metal (aluminium or mild steel) treated as necessary to provide the required protection and mechanical strength for the application and environment.

Page 5 Materials used shall ensure deterioration due to atmospheric and/or local environmental conditions shall have no detrimental effect on the structural integrity or visual appearance (including colour fading or corrosion) of the finished enclosure for a period of not less than ten (10) years. Contact between untreated, dissimilar metals shall be avoided. Protective screens shall have an impact resistance suitable for their purpose. Protective screens shall not deflect by more than 2mm at any point on the surface due to the effects of environmental conditions. Protective screens shall be coated to mitigate dirt adhesion, and shall remain effective, without any maintenance other than cleaning, for the design life of the equipment. 2.3.3 Doors LSU and individual LSU controller enclosures shall have flush fitting doors with secured access. Locks of a type approved by the Engineer shall be used, and at least two keys shall be supplied with each sign. All keys shall be keyed identically and shall match the existing LCS units. 2.3.4 Sign mounting Installations shall be provided with a facility to adjust and align the optical axes, according to the local geometry. This adjustment mechanism shall employ a suitable arrangement for locking the sign in the desired position. 2.3.5 Construction requirements All hardware supplied shall be: Industry standard, readily available from multiple suppliers; Modular; Flexible, allowing for enhancement of hardware and functions; Low maintenance, self diagnostic and easily serviceable; and Supplied new. Materials shall be selected to prevent premature ageing. In particular, plastics shall be stabilised against the effects of UV radiation. 2.4 Control/data interface requirements 2.4.1 Sign control The LCS shall comply with the NTCIP standard for device communications. The LCS equipment shall respond to control commands issued at the local field controller. These commands will be initiated by the local field controller processing, or by central control computer(s) processing. A control unit with an industry standard electrical interface shall be employed for each sign to enable control from the Traffic Operations Centre and to report the status of the sign to the central system. 2.4.2 Status feedback A heartbeat signal originating at the central control computer(s) shall be used to confirm communications with the event response equipment. A default message shall be displayed in the event of a communications failure between the equipment and the central control computer(s).

Page 6 The event response equipment shall incorporate an industry standard electrical interface to the local controller for purposes of control and status feedback. The control unit shall provide the following status information to the central system: Power failure; Communications failure; Display element failure; Incorrect message displayed; Message updated; External luminance level (lux); and Luminance setting. 2.4.3 Data transmission The Contractor shall provide a means for data transmission between the central computer system and each sign, utilising an appropriate technology. The performance of the data transmission shall not be adversely affected by other simultaneous operations of VMS, CCTV, FMS etc. The Contractor shall provide all equipment, interface devices, cabinets, cabling, software and license agreements, as required, to establish error-free data transmission communications between each sign and the central computer system in accordance with this specification. 2.5 Electrical requirements A UPS shall be provided to provide on-line power to each LCS field controller and any other components that are necessary to maintain communication with the Traffic Operations Centre. The UPS shall be sized to maintain the systems for a period of one hour. The UPS shall be an on-line type and shall provide a no-break transfer to battery backed power in the event of mains power failure. The UPS shall utilise low maintenance, sealed gel type lead acid batteries. A bypass switch shall be provided to enable the UPS to be either a) switched into circuit, b) switched out of circuit or c) the mains disconnected to test the UPS. Each sign shall be fitted with lightning and surge diversion equipment. All internal and external wiring to the display units shall utilise cable connectors or card slot contacts to readily facilitate disassembly for maintenance purposes. 2.6 Testing requirements The Contractor shall ensure that factory acceptance testing on all signs includes tests for the following: Assessment of pixel output intensity levels; Assessment of colour uniformity; Demonstration of correct operation under varying external luminance conditions; Demonstration of door operation and weatherproofing; Demonstration of all pixels activated/deactivated in alternating mode using a checkerboard test pattern for 30 minutes minimum;

Page 7 Demonstration of operation with the sign control unit, including demonstration of the use of all software commands and application messages; Continuous soak test operation over 48 hours using a message display change every 15 minutes. Any pixel failures during this test will require satisfactory repeat of the complete test; and Sign response time for commands implemented at the sign control unit. In addition to the tests defined above a representative communication link between the sign and its control unit, utilising the intended equipment for communication to be installed in the field shall be established to confirm correct operation in accordance with this specification. All testing to include FAT, SAT and Commissioning shall conform to section 8 of Document SP/M026R2 in Appendix A. 2.7 Maintenance requirements Each event response equipment shall be designed to facilitate planned and breakdown maintenance with the minimum of equipment and in the shortest time. All event response equipment shall be fully serviceable from the rear. Event response equipment design shall for all replacement, repair, or maintenance activities, shall ensure there is no risk of any element of the event response equipment, enclosure, maintenance materials or tools falling on to the carriageway below. Event response equipment shall not require more than two field visits annually for routine maintenance.