IP-LINX Fiber :: X-XXXX

Similar documents
IP-LINX. Installation Guide

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Optical Distribution Box 300 Installation Guide. Version : R0.0

3M Distribution Box (DDB)

HCS - HES Cabling Systems

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Panduit Recommended Best Case Practice Split Fibre

Medium Box for Cable Termination

LTX Optical Distribution Panels. Ordering Guide

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SLiC Fiber Aerial Closure System

Section Communications Optical Fiber Backbone Cabling

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Gel-sealed in-line fiber optic closure

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

FOSC 450 C6 and D6 Closures

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

3M Fiber Optic Wall Mount Enclosure 8430 Series

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

27mm ECAM Double Cable Entry Port

2178-L/S Series Fiber Optic Splice Case with Gasket

LGX Compatible (LSX) Connector Module) User Manual)

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

18mm ECAM Cable Entry Port

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

INSTALLATION INSTRUCTIONS

GENUINE PARTS CAUTION

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Connectivity accessories by Nestor Cables

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

PRODUCT DESCRIPTION N3S

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

INSTALLATION INSTRUCTIONS MO023A

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

ADF Module. Installation Guide. 1.1 Overview

Coyote popup display set up instructions

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Seal Kits for BUDI Enclosures

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

LANmark-OF ENSPACE Patch Panel

Water blocking tape. Locator ridge HPA-0486

Preferred ordering guide for NETCONNECT

Fiber Cable Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr Fiber CFDP2 Pedlockr OSP Pedestal)

Instruction manual. Midi Fiber Dome. Instruction manual

3. Electronics and MMU2 unit assembly

Cabling and Completing Assembly of the Cisco TelePresence System 1000

Cable Installation Tips

Cable Installation Tips

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

INSTALLATION INSTRUCTIONS

3M Coupling Tray FDTC-10S-COUPLINGTRAY

NewScope-7A Operating Manual

What is SnoCam? SnoCam Installation Guide. SolarVu

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Opterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction

The FiberMark1 offers an ideal solution for

GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)

NGF optical distribution frame

Cable ISOBUS Active Termination

FACT Cable Termination Unit

Cable and Power Management Open-Frame Rack Cable Managers

6000 Series Patch Panel Terminating Instructions

Bulkhead Style Optical Panels. Telect LCX Series Installation Guide

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

3 SLiC Aerial Closure with Rubber End Seal

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

3M Better Buried Compound Compression Closure System

FOSC 400 A4 Fiber Optic Splice Closure

RetractaNet XS. Extractable Solutions for OSP. October 2012

UNSIGNED HARDCOPY NOT CONTROLLED

ASSEMBLY INSTRUCTIONS

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

Crane Systems Extension Reel Cable Guide Hardware Kit

VIP-35 Manual. Video Inspection Probe

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

GENUINE PARTS. SIRIUS Under Glass Antenna Kit

4320 SS-25 Self-Strip Terminating Block

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

Public Works Division Lighting District Fiber Optic Specifications April 2009

FOSC 400 C5 & D5 Fiber Optic Splice Closures

2178 L/S Series Fiber Optic Splice Cases and Accessories

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

Transcription:

Fiber :: 055-797X-XXXX User Manual Telect, Inc. All rights reserved. 146653-A0

Table of Contents Chapter 1: Introduction...3 1.1 Tools Required...3 1.2 Additional Parts...3 1.3 Assemblies...3 Chapter 2: Installation...4 2.1 Installing Patch Plates...4 2.2 Mounting the IP-LINX Enclosure...5 2.3 Installing the Incoming Cable...5 2.3.1 Installing the Optional Cable Clamp Kit for Standard Indoor Enclosure...6 2.3.2 Installing the Incoming Cable in the Outdoor Assembly...6 2.4 Using IP-LINX to Patch Only...8 2.5 Splice and Patch: Installing Pigtails...9 2.6 Splice and Patch: Mounting the Splice Cassette and Finish...9 Chapter 3: Accessories and Ordering Information... 11 List of Figures Figure 1-24-Fiber IP-LINX Enclosure...3 Figure 2 - Patch Plate Installation...4 Figure 3 - Rubber Grommet...5 Figure 4 - Rubber Grommet at Cable Entry Location...5 Figure 5 - Cable Bracket...6 Figure 6 - Cable Clamp on Enclosure...6 Figure 7 - Example of Installed Panel...7 Figure 8 - Patch-Only Fiber Routing...8 Figure 9 - Splicing Pigtails...9 Figure 10 - Splice Cassette (P/N TTN-HS12)...10 Figure 11 - Splice Cassette Installation...10 2

Chapter 1: Introduction This guide explains how to install the wall-mounted IP-LINX and Mini IP-LINX enclosures and how to route and secure the fiber-optic cable within the enclosures. 1.1 Tools Required You need the following tools: Marking pen Phillips screwdrivers/drill Utility knife Heat gun (optional) Flathead screwdriver (for power plates) 1.2 Additional Parts IP-LINX enclosures reccomend the following additional parts that must be ordered separately: Patch plates with adapters Splice sleeves (P/N KIT-SLEEVES) Cable clamp for standard indoor enclosure only (P/N KIT-CLMP-IPL) Fiber pigtails Labels to identify pigtails (masking tape or pre-numbered cable labels) When patching only (no splice), you do not need splice cassettes or pigtails. However, you do need adapter plates to terminate the incoming cable. Refer to Accessories and Ordering Information on page 11 to order additional parts. 1.3 Assemblies Each enclosure consists of a metal chassis with a cam or keyed locking door, cable entry slots, cord grips or grommets, splice cassettes, and spools for fiber routing. An optional installation kit (P/N KIT-IP-LINX), found on page 11, includes the following: Figure 1-24-Fiber IP-LINX Enclosure Cable ties, 4 inches (6) Cable tie mount (4) Velcro cable wraps (6) Splice sleeves (12) 3

Chapter 2: Installation Please read and understand all instructions before starting installation. If you have questions, contact Telect Technical Support at support@telect.com or call 1.509.926.6000. When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Telect at support@telect.com or call 1.509.926.6000. Telect is not liable for transit damaged. If the product is damaged, please report it to the carrier and contact Telect. 2.1 Installing Patch Plates 1. Make sure the latches on the patch plates are pulled out. 2. Insert the patch plate (adapter key way facing up) latches into their mounting holes on the IP-LINX enclosure bulkhead. 3. Push the patch plates until they are flush with the bulkhead. 4. Push in the latches to secure each plate. Adapter plate Latch Adapter key ways Bulkhead Figure 2 - Patch Plate Installation 4

2.2 Mounting the IP-LINX Enclosure 1. Place the mounting-hole template against the wall where you want to mount the enclosure. 2. Mark the location of the appropriate template holes on the wall. 3. Install suitable wall anchors (not included). 4. Secure the enclosure to the wall. Figure 3 - Rubber Grommet 2.3 Installing the Incoming Cable 1. Score the grommet with a utility knife at the desired cable entry location. Refer to Figures 3 and 4 2. Push the cable through the hole that you cut in the grommet. 3. Mark the cable according to the number of wraps you wish to store in the IP-LINX enclosure. Use the tables below to determine where to make the mark. The tables provide the length of incoming cable that can be stored given the number of spool layers in the enclosure. Figure 4 - Rubber Grommet at Cable Entry Location Table 1 - Splice & Patch Marking Location: Storage Spools (Enclosure & Cassette) Inches Cm 1 80 203 ±2 2 140 356 ±2 Table 2 - Patch Only Storage Spools Inches Marking Location: 1.5 70 178 ±2 2.5 102 259 ±2 3.5 138 351 ±2 The number of wraps the cables make within the IP-LINX enclosure is left up to installer preference. For other lengths or paths, use the spools, and maintain proper bend radius. Cm 5

4. Slide the grommet up the cable past the mark on the cable jacket. 5. If not already, re-install the rubber gromment int he slot on the enclosure. 2.3.1 Installing the Optional Cable Clamp Kit for Standard Indoor Enclosure 1. Using a Phillips screwdriver, remove two screws from the cable bracket at the top or bottom of the panel. 2. Place the bracket around the cable in the desired location. 3. Reinstall the two screws to hold the cable bracket firmly in place. 4. Attach the clamp bracket to the top or bottom of the enclosure, next to the cable entry slot. Figure 5 - Cable Bracket Figure 6 - Cable Clamp on Enclosure 2.3.2 Installing the Incoming Cable in the Outdoor Assembly 1. Loosen compression nut by turning counter clockwise. 2. Insert cable end through the cord grip gland. (Accepts cable dia..435-.705 in.) 3. Tighten compression nut by turning clockwise. 6

Figure 7 - Example of Installed Panel 7

2.4 Using IP-LINX to Patch Only Use the instructions in this section if you are using the IP-LINX enclosure for patch only. 1. From the cable entry end, wrap the fiber strands counter-clockwise around the spools. For bottom cable entry, route the strands clockwise. 2. Attach the connectors to the column of patch plate adapters closest to the back wall of the enclosure. Attach the connectors in order, from top-to-bottom. Use Table 3, Fiber Connection Color Codes, listed below. 3. Repeat Steps 1 and 2 for the next group of 12 fiber strands, and attach the connectors to the next column of adapters (1-12, top to bottom). NOTE: Always load the patch plates from top to bottom and from the rear of the IP-LINX enclosure to the front of the enclosure. Figure 8 - Patch-Only Fiber Routing Refer to the following table for fiber connection color codes. Table 3 - Fiber Connection Color Codes For This Connection: 1 Blue 2 Orange 3 Green 4 Brown 5 Gray 6 White 7 Red 8 Black 9 Yellow 10 Purple 11 Pink 12 Aqua Use This Color: 8

2.5 Splice and Patch: Installing Pigtails Use the instructions in this section if you are using the IP-LINX enclosure to splice and patch. 1. Attach the pigtail connectors to the column of patch plate adapters closest to the back wall of the enclosure. Always attach pigtails from top to bottom and from the back wall of the enclosure to the front. Label the pigtails accordingly. 2. Route the pigtails around the spools to take up the amount of desired slack. 3. Repeat Steps 1 and 2 for each group of 12 pigtails, then go to the next section. NOTE: The number of wraps that pigtails and incoming cable fibers make within the IP-LINX enclosure and the splice tray is left up to installer preference. 2.6 Splice and Patch: Mounting the Splice Cassette and Finish Skip this section if you are patching only. Figure 9 - Splicing Pigtails 1. (Optional) Apply heat-shrink tubing around the jacket cut point. Keep half of the heat-shrink tube length over the cable jacket, and the other half over the exposed buffer tubes or fiber strands. See Figure 7 for an example of the installed cable and panel. If incoming cable is jacketed unsheathe the fiberoptic cable by cutting the outside jacket to an appropriate length for each fiber to be spliced according to splicing machine recommendations. 2. Trim away the excess fiber length, but leave enough fiber for splice preparation. Remove the fiber from the splice cassette to the splice station. NOTE: Use this trimmed fiber to measure and trim the length of the bundle s remaining five fibers. 3. Remove the desired splice tray. 9

4. Splice the pigtail fiber strand to the appropriate 900-μm colored fiber strand from the incoming cable. 5. Repeat Step 4 to splice the remaining pigtail fibers to the incoming cable s color-coded fiber strands. Splice the pigtails in order. Refer to Table 3, Fiber Connection Color Codes, on page 8 to follow the color-codes. 6. Once the splicing is complete, carefully route the pigtails around the provided storage spools and inside of the splice cassette once or twice counterclockwise. For bottom cable entry, wrap the fiber strands clockwise. 7. Place the completed splice into the splice holder. 8. Carefully tuck in any stray fiber strands so that they will not be pinched. Replace the cover plate on the splice cassette. 9. Slide the splice cassette onto the threaded post. 10. Secure the cassette with the wing nuts. 11. Use the adhesive designation label to identify each connection. 12. Apply the designation label to the inside of the enclosure door. 13. Close and lock the enclosure. 14. Apply grounding cables/straps to enclosure where necessary. Figure 10 - Splice Cassette (P/N TTN-11S12) Figure 11 - Splice Cassette Installation 10

Chapter 3: Accessories and Ordering Information Contact your Telect Customer Service Representative at 1-800-551-4567 to order connectorized cables or any of the parts listed below. Table 4 - Accessories 6-Port Patch Panels SC/UPC 055-0000-6010 SC/APC 055-0000-6070 8-Port Patch Panels SC/UPC 055-0000-6080 SC/APC 055-0000-6090 12-Port Patch Panels LC/UPC 055-0000-5010 LC/APC 055-0000-6090 SC/UPC duplex 055-000-6210 SC/APC duplex 055-0000-6270 24-Port Patch Panels LC/UPC 055-0000-5210 LC/APC 055-0000-5290 Other Patch Panels LC/APC 6-fiber, 6 DC terminals 055-0000-3P6G LC/UPC 8-fiber, 6 DC terminals 055-0000-3P8L 12 DC terminals 055-0000-PWR12 Blank patch panel 055-0000-9000 Other Splice cassette TTN-HS12 Splice sleeves (qty 12) KIT-SLEEVES Fiber spool, 2-pack 055-SPOOL Cable clamp (bracket, hardware) KIT-CLMP-IPL Accessory kit: KIT-IP-LINX Velcro cable wraps, cable ties/mounts 12-pack splice sleeves Weatherproof Compression Gland, 2-pack 055-CRDGRP Ordering Information Table 5 - IP-LINX Part Number Decoder 0 5 5 7 7 6 Fiber only 9 Fiber/DC E Fiber/Ethernet D DC only 0 Indoor Standard Enclosure 1 Outdoor Standard Enclosure 2 Outdoor Mini Enclosure 3 Indoor Mini Enclosure Standard 03 3 Fbr / 3 pair PWR 06 6 Fbr / 3 pair PWR 08 8 Fbr / 3 pair PWR 84 8 Fbr / 4 pair PWR 12 12 Fbr / 6 pair PWR 24 24 Fbr / 6 pair PWR 48 48 Fbr / 6 pair PWR 00 No Pigtails 02 Stranded Pigtails 11 Ribbon Pigtails G LC/APC L LC/UPC N SC/APC S SC/UPC K Keyed (Blank is telecom hex) Mini 03 3 Fbr / 3 pair PWR 06 6 Fbr / 3 pair PWR 08 8 Fbr / 3 pair PWR 84 8 Fbr / 4 pair PWR 12 12 Fbr or 6 pair PWR 11