Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1

Similar documents
USB Contents. Definitions SPECIFICATIONS. RF Power Sensor Device

This document lists specifications for the PXI-5691 RF amplifier.

This document lists specifications for the NI PXIe-1491 high-definition multimedia interface (HDMI) analyzer.

NI PXI/PXIe-2543 Specifications

Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 C to 55 C, unless otherwise noted.

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. may impair the protection the NI PXIe-7822R provides.

2.7 GHz RF Vector Signal Analyzer with Digital Downconversion. This document lists specifications for the NI PXI-5661 RF vector signal analyzer.

NI 9238 Datasheet DATASHEET. 4 AI, ±500 mv, 24 Bit, 50 ks/s/ch Simultaneous

Note In this document, the NI 9202 with spring terminal and the NI 9202 with DSUB are referred to inclusively as the NI 9202.

NI 9239 DATASHEET. 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI 9244 Datasheet DATASHEET. 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

NI 9260 DATASHEET. 2 AO, 3 Vrms, 24 Bit, 51.2 ks/s/ch Simultaneous

NI 9246 DATASHEET. 3-Channel, 20 Arms Continuous, 24-Bit, Analog Input Module

NI 9230 DATASHEET. 3 AI, ±30 V, 24 Bit, 12.8 ks/s/ch Simultaneous

NI 9251 with mini XLR

Specification Value Comments

NI R Series Multifunction RIO Specifications

Digital Input Modules for Compact FieldPoint

USER MANUAL. Inverted Pendulum Experiment CAPTIVATE. MOTIVATE. GRADUATE.

Used for writing unscaled or raw data and covers the range from negative full scale (0) to positive full scale (65,535).

Thermocouple and RTD Modules for Compact FieldPoint

USER MANUAL. IP02 Base Unit Experiment. Set Up and Configuration CAPTIVATE. MOTIVATE. GRADUATE.

MAP110 AC-DC Series Data Sheet

FP-AI-112 and cfp-ai-112

Supplement. TDS1000 and TDS2000 Series User Manual Specifications Update

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

NI USRP-2950R/2952R/2953R/ 2954R

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Specifications. Reference Documentation. Performance Conditions

NI GSM/EDGE+ Toolkit Specifications

Magnecraft Power Relays

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Software. Documentation. Test Equipment

LONWORKS Fibre Optic Converter

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

POWER. DA10-M Series. 10 Watts. Data Sheet. Total Power: 10 Watts Input Voltage: Vac # of Outputs: Single, 5 Volts SPECIAL FEATURES

R&S ZN-Z154 Calibration Unit Specifications

WVR500 Waveform/Vector Monitor

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

02/11/2015

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Data Pattern Generator

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Fibre optic router for TP/FT-10 LRW-112PP

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

LONWORKS Fibre Optic Router

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

BNC-2090A QUICK START GUIDE. Rack-Mount Connector Accessory for E/M Series DAQ Devices

R&S ZN-Z85 Switch Matrix Specifications

SWR Programmable Audio Switcher U S E R S M A N U A L

NI PXIe Contents GETTING STARTED GUIDE. 6.6 GHz RF Vector Signal Analyzer with Digital Downconversion

PXIe-5667 (7 GHz) Contents GETTING STARTED GUIDE. Vector Signal Analyzer

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC connection. 500 MHz system bandwidth. Double HF adjustment

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC Connection. 500 MHz System Bandwidth. Double HF Adjustment

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

PMG. Vibration Energy Harvesters

Fibre Optic Modem ODW-611

MKH 8060 Directional studio microphone

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI PXI Contents GETTING STARTED GUIDE. 2.7 GHz RF Vector Signal Analyzer with Digital Downconversion

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

Fibre Optic Modem ODW-622

NI PXIe-5668R. Contents GETTING STARTED GUIDE GHz or 14 GHz Vector Signal Analyzer

Electrical Specifications

PXIe Contents GETTING STARTED GUIDE. 3.6 GHz or 14 GHz Vector Signal Analyzer

NI GSM/EDGE Toolkit Specifications

3500/42E Vibration Monitor

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

AW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

HD-One DX/DX500 HDMI Extender

Instructions. P MHz 1X/10X Passive Probe

ODW-621. RS-232 Point-to-point applications

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

MILLITARY SPECIFICATION SHEET

NI PXIe-5667 (3.6 GHz)

Datasheet - SRB301LC 24VAC/DC

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Model Number Structure

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Ordering details. Approval. Classification

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

32 Channel CPCI Board User Manual

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

MKE 2 Gold. Instruction manual

MultiView T4 / T5 Transmitter

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

R&S RT-Zxx Standard Probes Specifications

User Guide. HDMI Fiber Optic Extender. DVI-7350a

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

OM2000N INSTALLATION MANUAL

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Transcription:

DEVICE SPECIFICATIONS NI PXIe-2524 Multibank Configurable 1-wire Multiplexer This document lists specifications for the NI PXIe-2524 (NI 2524) multiplexer relay module. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications.... Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1 Contents About These Specifications... 1 Input Characteristics... 2 RF Performance Characteristics...3 Dynamic Characteristics... 4 Physical Characteristics... 4 Environment...5 Operating Environment...5 Storage Environment...5 Shock and Vibration...5 Diagrams... 6 Accessories8 Compliance and Certifications...9 Safety 9 Electromagnetic Compatibility... 9 CE Compliance... 10 Online Product Certification... 10 Environmental Management... 10 About These Specifications Specifications characterize the warranted performance of the instrument under the stated operating conditions. Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 C ambient temperature. Typical specifications are not warranted. All voltages are specified in DC, AC pk, or a combination unless otherwise specified.

Caution The protection provided by the NI 2524 can be impaired if it is used in a manner not described in this document. Input Characteristics Maximum switching voltage Channel-to-channel 150 V Channel-to-ground 150 V, CAT O Note This module is rated for Measurement Category I. It is intended to carry signal voltages no greater than 150 V. This module can withstand up to 800 V impulse voltage. Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Do not connect to MAINS supply circuits (for example, wall outlets) of 115 VAC or 230 VAC. Refer to the Read Me First: Safety and Electromagnetic Compatibility document for more information about measurement categories. Measurement Categories CAT I and CAT O (Other) are equivalent and are for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. This category is for measurement of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special hardware, limited-energy parts of hardware, circuits powered by regulated low-voltage sources, and electronics. Caution When hazardous voltages (>42.4 V pk /60 VDC) are present on any channel, safety low-voltage ( 42.4 V pk /60 VDC) cannot be connected to any other channel.... Maximum switching power 60 W, 62.5 VA Caution The switching power is limited by the maximum switching current, the maximum voltage, and must not exceed 60 W, 62.5 VA. CH-COM... DC isolation resistance >1 GΩ, typical at 25 C Maximum current Switching 2 A (per channel) Carry 2 A (per channel)... Minimum switch load 20 mv/1 ma Note The NI 2524 is not recommended for 2-wire resistance measurements. 2 ni.com NI PXIe-2524 Specifications

Note Switching inductive loads (for example, motors and solenoids) can produce high voltage transients in excess of the module s rated voltage. Without additional protection, these transients can interfere with module operation and impact relay life. For more information about transient suppression, visit ni.com/info and enter the Info Code relayflyback. DC path resistance Initial <0.8 Ω End-of-life 1.8 Ω DC path resistance is a combination of relay contact resistance and trace resistance. Measure path resistance by combining the resistance of the high and low signal paths from one row to one column. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly above 1.8 Ω. Thermal... EMF <10 µv RF Performance Characteristics... Bandwidth (-3 db, typical at 23 ºC) 10 MHz 50 Ω termination Open channel isolation (typical at 23 ºC) 50 Ω termination 10 khz 65 db 100 khz 59 db 1 MHz 37 db Channel-to-channel crosstalk (typical at 23 ºC) 50 Ω termination 10 khz -68 db 100 khz -55 db 1 MHz -36 db NI PXIe-2524 Specifications National Instruments 3

Dynamic Characteristics Relay operate time Typical 1 ms Maximum 3.2 ms Simultaneous drive limit 90 relays Expected relay life Mechanical 1 10 8 cycles Electrical 30 mv, 10 ma resistive 2.5 10 6 cycles 30 V, 1 A 5 10 5 cycles 30 V, 2 A 1 10 5 cycles 60 VDC, 1 ADC resistive 1 10 5 cycles Note Relays are field replaceable. Refer to the NI Switches Help at ni.com/ manuals for more information about replacing a failed relay. Physical Characteristics Relay... type Electromechanical, non-latching... Relay contact material Palladium-ruthenium, gold covered... Front panel connector 160 DIN 41612, 160 positions, male Power requirement PXI Express 12 V 24 W 3.3 V 3.4 W... Dimensions (L W H) 3U, one slot, PXI/cPCI module, PXI Express compatible 21.6 cm 2.0 cm 13.0 cm (8.5 in. 0.8 in. 5.1 in.) Weight... 241 g (8.5 oz) 4 ni.com NI PXIe-2524 Specifications

Environment Maximum... altitude 2,000 m (800 mbar) (at 25 C ambient temperature)... Pollution Degree 2 Indoor use only. Operating Environment... Ambient temperature range 0 C to 55 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative... humidity range 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) Storage Environment Ambient... temperature range -40 C to 71 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) Relative... humidity range 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) Shock and Vibration... Operating shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) Random vibration Operating 5 Hz to 500 Hz, 0.3 g rms Nonoperating 5 Hz to 500 Hz, 2.4 g rms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) NI PXIe-2524 Specifications National Instruments 5

Diagrams The following figure shows the NI 2524 power-on state. 6 ni.com NI PXIe-2524 Specifications

Figure 1. NI 2524 Power-On State CH 0 CH 4 CH 1 CH 5 CH 2 CH 6 CH 3 CH 7 kb0s1 kb0s2 kb0s3 kb0s4 kb0com1 kb0com2 COM0 COM 0 CH 0 Bank 0 kbc08 Bank 8 CH 64 COM 8 CH 7 COM 1 CH 8 CH 15 COM 2 CH 16 Bank 1 Bank 2 kbc01 kbc02 kbc89 kbc810 Bank 9 Bank 10 CH 71 COM 9 CH 72 CH 79 COM 10 CH 80 CH 23 COM 3 CH 24 Bank 3 kbc23 kbc1011 Bank 11 CH 87 COM 11 CH 88 CH 31 COM 4 CH 32 Bank 4 kbc04 kbc812 Bank 12 CH 95 COM 12 CH 96 CH 39 COM 5 CH 40 CH 47 COM 6 CH 48 Bank 5 Bank 6 kbc45 kbc46 kbc1213 kbc1214 Bank 13 Bank 14 CH 103 COM 13 CH 104 CH 111 COM 14 CH 112 CH 55 COM 7 CH 56 Bank 7 kbc67 kbc1415 Bank 15 CH 119 COM 15 CH 120 CH 63 CH 127 The following figure shows the NI 2524 connector pinout. NI PXIe-2524 Specifications National Instruments 7

Figure 2. NI 2524 Connector Pinout CH 0 COM 0 CH 4 CH 8 COM 1 CH 12 CH 16 COM 2 CH 20 CH 24 COM 3 CH 28 CH 32 COM 4 CH 36 CH 40 COM 5 CH 44 CH 48 COM 6 CH 52 CH 56 COM 7 CH 60 CH 64 B32 A32 B31 A31 B30 A30 B29 A29 B28 A28 B27 A27 B26 A26 B25 A25 B24 A24 B23 A23 B22 A22 B21 A21 B20 A20 B19 A19 B18 A18 B17 A17 C32 D32 E32 C31 D31 E31 C30 D30 E30 C29 D29 E29 C28 D28 E28 C27 D27 E27 C26 D26 E26 C25 D25 E25 C24 D24 E24 C23 D23 E23 C22 D22 E22 C21 D21 E21 C20 D20 E20 C19 D19 E19 C18 D18 E18 C17 D17 E17 C16 CH 1 CH 2 CH 3 CH 5 CH 6 CH 7 CH 9 CH 10 CH 11 CH 13 CH 14 CH 15 CH 17 CH 18 CH 19 CH 21 CH 22 CH 23 CH 25 CH 26 CH 27 CH 29 CH 30 CH 31 CH 33 CH 34 CH 35 CH 37 CH 38 CH 39 CH 41 CH 42 CH 43 CH 45 CH 46 CH 47 CH 49 CH 50 CH 51 CH 53 CH 54 CH 55 CH 57 CH 58 CH 59 CH 61 CH 62 CH 63 CH 65 CH 66 CH 64 COM 8 CH 68 CH 72 COM 9 CH 76 CH 80 COM 10 CH 84 CH 88 COM 11 CH 92 CH 96 COM 12 CH 100 CH 104 COM 13 CH 108 CH 112 COM 14 CH 116 CH 120 COM 15 CH 124 A17 B16 A16 B15 A15 B14 A14 B13 A13 B12 A12 B11 A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1 A1 CH 65 C16 D16 CH 66 E16 CH 67 C15 CH 69 D15 CH 70 E15 CH 71 CH 73 C14 D14 CH 74 E14 CH 75 CH 77 C13 D13 CH 78 E13 CH 79 C12 CH 81 D12 CH 82 E12 CH 83 CH 85 C11 D11 CH 86 E11 CH 87 CH 89 C10 D10 CH 90 E10 CH 91 C9 CH 93 D9 CH 94 E9 CH 95 C8 CH 97 D8 CH 98 E8 CH 99 C7 CH 101 D7 CH 102 E7 CH 103 C6 CH 105 D6 CH 106 E6 CH 107 C5 CH 109 D5 CH 110 E5 CH 111 C4 CH 113 D4 CH 114 E4 CH 115 CH 117 C3 D3 CH 118 E3 CH 119 C2 CH 121 D2 CH 122 E2 CH 123 C1 CH 125 D1 CH 126 E1 CH 127 Accessories Table 1. NI Accessories for the NI 2524 Accessory Part Number DIN160 to 50-pin D-SUB switch cable, 1 m 782417-03 DIN160 to DIN160 switch cable, 1 m 782417-02 8 ni.com NI PXIe-2524 Specifications

Table 1. NI Accessories for the NI 2524 (Continued) Accessory Part Number DIN160 to bare wire switch cable, 1 m 782417-01 Relay replacement kit for IME02TS Relays 782461-10 Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions EN 55022 (CISPR 22): Class A emissions EN 55024 (CISPR 24): Immunity AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations, certifications, and additional information, refer to the Online Product Certification section. NI PXIe-2524 Specifications National Instruments 9

CE Compliance This product meets the essential requirements of applicable European Directives, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 电子信息产品污染控制管理办法 ( 中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物质指令 (RoHS) 关于 National Instruments 中国 RoHS 合规性信息, 请登录 ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2014 National Instruments. All rights reserved. 376204A-01 Dec14