SR Series. Spring Return dosing pump D - mechanical diaphragm. The right dosing choice

Similar documents
Type D mechanical diaphragm

Spring Return dosing pump FM - mechanical diaphragm

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

PRIMEROYAL Series API 675 metering pump

2.9 Sigma/ 2 Plunger Metering Pumps

GRUNDFOS alldos product information. The solution for complex dosing tasks

istep STEPPER MOTOR PUMP

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

Tekna evo. innovation technology future 03

istep STEPPER MOTOR PUMP

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

PRIMEROYAL Series. Metering Pump. Model PN

Admiss. counterpressure

Motor-driven and process metering pumps for all capacity ranges

Screw pump Series ALLFUEL AFT

Series description: Wilo-Jet HWJ

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Magnetic Stirrers Magnetic Stirr

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Gear Pump Units For single-line centralized lubrication systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

DM 50 / DM / 2- component dosing and mixing system. engineering

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Revision 2.0 Parts List Minor

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Smart Standard. With ProCam Smart Bran+Luebbe offers a high quality, economic pump for the customer with less demanding applications.

Immersion Pumps HCT (High Chem) sealless EN

Series description: Wilo-Drain VC

Series description: Wilo-Sub TWU 3 HS

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Up to 85% higher Service Life due to efficient sealing method.

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Gear Pump Units. For single-line lubrication systems

Modular Lube Lubrication Systems System Controls

Revision 1.0 Parts List Minor

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

Immersion Pumps HCT (High Chem) sealless

82540/ /2-way diaphragm valves

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Bartels Micropumps. ( ) Rev. 2.8

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

Portable Filter Cart Type SPFC

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Agilent High Capacity RV Pumps & Roots Pumping Systems

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

Ecoline S Series. Efficient solutions for quality production. Innovations for a better world.

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Electric Rotary Modules. Rotary Actuators

Solenoid valves VZWD, directly actuated

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

w w w.o r i g i n a l d o m e v a l v e.c o m The number one valve for bulk material handling applications Dome Valve Line and Vessel Isolation Valve

800 Displaying Series Flowmeter

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

DM 402/ / multi-component low pressure dosing and mixing system. engineering

DM 402/ / multi-component low pressure dosing and mixing system. engineering

Optical Cryostat - Omniplex TM

GS-HYDRO END FORMING MACHINES

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Revision 2.0 Parts List Minette 1~, 3~

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

The full range of performance

SureFire PDI Lubricator

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Solenoid valves VZWD, directly actuated

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

MVSI-TS. Technical features

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

SMALL OIL SEALED PUMPS

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

XR47-24 Models 24 W/ F (43 W/ C)

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Split System Air Conditioner

Level Measurement Point level measurement - RF Capacitance switches

Revision 1.0 Parts List Mega

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

PROPORTIONAL VALVES Sentronic plus

Revision 3.0 Parts List Salvador 1~, 3~

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

High Head Close-Coupled Centrifugal Pumps

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories

FLOMAT Electromagnetic Insertion Flowmeter

For over a decade, FCI Watermakers has been providing. the industry s finest reverse osmosis systems available.

Functions and Features: Prime key for fast filling and emptying.

Mechanical flow switch for On/Off control

Transcription:

SR Series Spring Return dosing pump D - mechanical diaphragm The right dosing choice

SR Series Type D

Spring Return Mechanical Diaphragm Dosing Pumps MAIN ELEMENTS TO SUPPORT OUR PRODUCTS Versatility Different diaphragm sizes are available to suit different applications, starting from 4 until 574 l/h Reliability The high degree of accuracy and reproducibility with high quality materials selected make the mechanical diaphragm SR series to assure the maximum reliability. Quality The best performance for the applications is achieved by optimal selection of material and diaphragm design. FEATURES Mechanical Diaphragm pumps are suitable for use when: - The dosed liquid contains small amounts of suspended solids - The dosed liquid contains a toxic solution - A drip proof/air tight application is required - High pressure is not required Each pump is fitted a standard gearbox reduction system and with a vertical mounted B14 shaped electric motor in accordance with UNEL-MEC specifications. The motor power range is from 0.18 up to 0.37 KW as the European standard: 3 phase voltages of 230/400V @ 50/60Hz, 4 pole and 1 phase voltages of 230/50/60 Hz or 110/60 Hz. As motors conform to UNEL-MEC specifications, there are many alternative option available, including different voltages, insulation class and special explosion proof versions. The gearbox is a standard wormwheel reduction system with all bearings supported within a fully lubricated gearbox. The mechanism for variation of the stroke length a positive stroke spring return that is operated by an eccentric.

SR Series Type D PUMPING HEADS Pumping heads are made in standard executions: S.S. 316, PVC and PP. A wide range of other materials like HASTELLOY, ALLOY, PTFE, PVDF are according to the liquid to be dosed. Standard liquid handled maximum temperature - 60 C with S.S. 316 pump head - 40 C with PVC pump head Jacketed pump head for either cooling or heating are available to suit requirements. DIAPHRAGM There are made in PTFE / NBR SUCTION AND DISCHARGE CONNECTIONS Normally are threaded, but they can be supplied also flanged. All the pumps have a ball valve standard: single and double balls by the function of the diaphragm diameter or the material execution. Stroke adjustment can be carried out: - Manual: by a linear micrometer screw - Electrical: via servo motor with 4-20 ma signal upon request interface PROFIBUS or other BUS - Pneumatic: by a pneumatic servo control with signal from 3 to 15 PSI MULTIPLE HEADED PUMPS Different multiple heads units are available on request. Each pumping element has independent adjustment while running or at standstill. D series Mechanical Diaphragm pumps are available in different sizes: - D 50 N Stroke lengh 5 mm - D 100 N Stroke lengh 10 mm - D 101 N Stroke lengh 10 mm - D 121 N Stroke lengh 12.50 mm For these four types, different diaphragm sizes are available to suit different applications for capacity and pressure. STROKE ADJUSTMENT Flow rate adjustment is possible while running or at standstill. The movement of the diaphragm is based on a precise reciprocating gearbox, which provides an exact volumetric displacement.

Spring Return Mechanical Diaphragm Dosing Pumps SOME STANDARDS EXECUTIONS FOR MECHANICAL DIAPHRAGM PUMPS EXECUT. PUMPHEAD VALVE (ball) VALVE SEATS DIAPHRAGM VALVES GASKETS 11 S.S. 316 S.S. 316 S.S. 316 PTFE/NBR FPM 12 PP/FRV PYREX PP/FRV PTFE/NBR FPM 13 PVC PYREX PVC PTFE/NBR FPM 16 PVC S.S. 316 PVC PTFE/NBR FPM 17 PP S.S. 316 PP PTFE/NBR FPM 23 PVDF PYREX PVDF PTFE/NBR FPM FPM = fluoroelastomer S.S 316 = stainless steel 316 C.O. = Chromium Oxide PP/FRV = polypropylene + glass fibber Difference executions on request Glossary and numbering system to identify pumps type D 100N 70/ B 11 DV 1ST group 2nd group 3rd group 4th group 5th group 6th group D series Reduction ratio group Diaphragm diameter Materials in touch with Not standard-special Mechanical diaphragm Stroke length (N of strokes/min) in mm the fluid code dosing pump F(1/24) B (1/12) In case of pumps supplied without motor add: W/M GENERAL OVERALL DIMENSIONS D050 D100 D101 D121 A 57 57 68 68 B 90 90 100 100 C 70 70 65 65 D 75 75 73 73 E 375 375 410 410 F 90 90 90 90 G 75 75 75 75 H 115 115 125 125 E H I I 65 65 65 65 L 7 7 7 7 D F G O M 130 130 170 170 N 33 33 33 33 L O 80 80 78 78 A B C N M General dimensional quote are indicative and adverted to the maximum acceptable pump dimension

SR Series Type D 050N TECHNICAL CHARACTERISTICS Pump type D-050N-30 D-050N-50 (*1) Reducer ratio Capacity (*2) Max Press. Kg / cm2 Connections (*3) SPM (*1) L/1 L/h Kg/cm2 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PP+FV PVC I 35 42 0,066 0,08 4 4,8 F 58 70 0,116 0,140 7 8,4 C 96 116 0,191 0,230 11,5 13,8 B 116 139 0,233 0,270 14 16,8 I 35 42 0,233 0,280 14 16,8 F 58 70 0,400 0,480 24 28,8 C 96 116 0,683 0,820 41 49,2 B 116 139 0,816 0,970 49 58,8 14 // 10 SS 316+ PVC+PP 1/2 G.m. Motor Features 0.18 3 Ph ~1400 rpm or 0.18 1 ph ~1400 rpm ø mm Diaphrag. 30 Stroke Lenght 5 Net Weights Kg (*4) SS 316 10 50 12 11 PVC- PP+FV 8 (*1) Piston s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1 ) I = Reducer ratio 1 : 40 = 35 strokes at 50 Hz / 42 strokes at 60 Hz F = Reducer ratio 1 : 24 = 58 strokes at 50 Hz / 70 strokes at 60 Hz C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz B = Reducer ratio 1 : 12 = 116 strokes at 50 Hz / 139 strokes at 60 Hz (*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and installation asset. (*3) Different ranges of connections are available on request (*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor. (5) The pumps can be supplied with accessories if requested (6) The pumps are epoxy coated RAL 7030

Spring Return Mechanical Diaphragm Type D 100N TECHNICAL CHARACTERISTICS Pump type D-100N-70 D-100N-90 D-100N-105 D-100N-120 (*1) Reducer Ratio Capacity (*2) SPM (*1) L/1 L/h Max Press. (*3) Kg/cm2 Connections (*4) Motor Features ø mm Diaphrag. Stroke Lenght Net Weights (*5) 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PVC SS 316 PVC SS 316 PVC I 35 42 0,75 0,9 45 54 F 58 70 1,25 1,50 75 90 C 96 116 2,06 2,50 124 150 B 116 139 2,50 3,00 150 180 I 35 42 1,15 1,38 69 82,8 F 58 70 1,91 2,30 115 138 C 96 116 3,16 3,83 190 230 B 116 139 3,83 4,59 230 276 I 35 42 1,56 1,87 94 112,3 F 58 70 2,60 3,12 156 187,2 C 96 116 4,30 4,96 258 298 B 116 139 4,96 5,95 298 357,6 I 35 42 1,78 2,12 106 127,4 F 58 70 2,95 3,54 177 212,4 C 96 116 4,86 6,23 292 374 B 116 139 6,23 7,47 374 448,8 5 1/2 G.m. 3 1,5 3/4 G.m. 0.18 3 Ph or 0.18 1 ph ~1400 rpm 70 10 11 8 90 12 8 105 12 8.5 1 G.m. 120 14 10 (*1) Piston s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1 ) I = Reducer ratio 1 : 40 = 35 strokes at 50 Hz / 42 strokes at 60 Hz F = Reducer ratio 1 : 24 = 58 strokes at 50 Hz / 70 strokes at 60 Hz C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz B = Reducer ratio 1 : 12 = 116 strokes at 50 Hz / 139 strokes at 60 Hz (*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and installation asset. (*3) Different ranges of connections are available on request (*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor. (5) The pumps can be supplied with accessories if requested (6) The pumps are epoxy coated RAL 7030

SR Series Type D 101N and D 121N TECHNICAL CHARACTERISTICS Pump type D-101N-70 D-101N-90 D-101N-105 D-101N-120 Reducer Ratio Capacity (*2) Max Press. Net Weights Kg Connections (*3) Kg/cm2 Motor ø mm Stroke SPM (*1) L/1 L/h (*4) (*1) Features Diaphrag. Lenght 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PVC SS 316 PVC SS 316 PVC F 70 84 1,50 1,80 90 108 C 96 116 2,05 2,46 123 147,6 B 120 144 2,56 3,07 154 184,8 F 70 84 2,46 2,96 148 177,6 C 96 116 3,36 4,04 202 242,4 B 120 144 4,25 5,10 255 306 F 70 84 3,35 4,02 201 241,2 C 96 116 4,58 5,50 275 330 B 120 144 5,51 6,61 331 397,2 F 70 84 3,75 4,50 225 270 C 96 116 5,13 6,16 308 369,6 B 120 144 6,80 8,16 408 489,6 8 1/2 G.m. 5 3 3/4 G.m. 0.25 3 Ph or 0.25 1 ph ~1400 rpm 70 10 11,5 8 90 13,5 10 105 14,5 11 1 G.m. 120 18 12 D-121N-120 F 70 84 5,36 6,44 322 386,4 C 96 116 7,30 9,56 438 525,6 B 120 144 9,56 11,47 574 688,8 3 1 G.m. 0.37 120 12,5 18 12 (*1) Piston s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1 ) F = Reducer ratio 1 : 20 = 70 strokes at 50 Hz / 84 strokes at 60 Hz C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz B = Reducer ratio 1 : 11,5 = 120 strokes at 50 Hz / 144 strokes at 60 Hz (*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and installation asset. (*3) Different ranges of connections are available on request (*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor. (5) The pumps can be supplied with accessories if requested (6) The pumps are epoxy coated RAL 7030

Spring Return Mechanical Diaphragm Dosing Pumps Accessoriability SAFETY VALVES PULSATION DAMPENERS BACK PRESSURE VALVES FILTERS Each metering pump can be supplied with accessories in order to improve the operation and accuracy of the units. The benefits of fluid control assure - Increase efficiency and pump life - Decrease maintenance and operation costs The control of fluid dynamics is essential to ensure efficient and safe use of process systems. Uncontrolled fluid in motion can physically destroy. A pumping system including the pumping, valves, meters, back pressure valves, inline instrumentation and equipment. 1.- FILTERS We suggest to install filters (on the suction pipe) to keep back impurities that can be presented on liquid to be dosed or coming from pipeline system. The use of filters assures a trouble-free dosing. 2.- SAFETY VALVES Safety valves are designed to protect the pump and chemical feed system from over pressure damage caused by defective equipment or a blockage in the chemical feed line. 3.- BACK PRESSURE VALVES Back pressure valves apply positive discharge pressure to a metering pump system to prevent siphoning and eliminate varying down-stream pressure. 4.- PULSATION DAMPENER Metering pumps have a pulsating flow. Both spring return plunger dosing pumps and quick closing valves start and stop fluids that are in motion. Spring return plunger dosing pumps derive their pumping action by capturing a given amount of fluid in a chamber and pushing it out the pump s discharge. Each pump cycle includes a suction stroke during the fluid flow is stopped. This pumping action produces an acceleration/ deceleration of the fluid, creating units of uncontrolled energy, resulting in PULSATION, observed as pressure spikes. Pulsation dampener is required for two reasons: - Two reduce high, non- permissible pressure fluctuations. - To create a nearly continuous flow.

Accessories Safety relief valves Type Pump capacity Connections TS-10 200 l/h 3/8 or 1 2 TS-13 400 l/h 1 2 G.F TS-21 1000 l/h 1 G.F Body PVC or S.S. 316 * S.S. 316 Relief - Safety valve setting pressure: max 40 kg/cm2 (588 Psi) higher pressures are available on request. PVC Relief safety valve setting pressure: max 10 kg/cm2 (145 Psi). For higher setting pressures consult our technical dept. Pulsation dampeners Type: HSTX Body in S.S.316, composed of two parts assembled by a special hosing that under dynamic pressures tends to close itself. Diaphragms are compatible to the liquid used. Built in accordance with ASME VIII Div. 1 rules. Type: HSTPVC Body in PVC, composed of two parts assembled by a special hosing that under hydraulic pressures tends to close itself. Maximum temperature: + 50 C. Diaphragms are compatible with the process liquid.

Relief valves Type Pump Capacity Connections VSCS-6 90 l/h 1 2 G.F VSCS-10 230 l/h 1 2 G.F VSCS-14 420 l/h 3 4 G.F VSCS-22 1050 l/h 1 G.F Body PVC or S.S. 316 Diaphragm PTFE/NBR * Relief valve setting pressure: 0 20 kg/cm2 the max value change due the size and materials G.F.= Cylindrical, Female Back pressure valves Type Pump Capacity Connections VSCC-6 90 l/h 1 2 G.F VSCC-10 230 l/h 1 2 G.F VSCC-14 420 l/h 3 4 G.F VSCC-22 1050 l/h 1 G.F Body PVC or S.S. 316 Diaphragm PTFE/NBR * Back pressure valve setting pressure: 0 2.5 kg/cm2 G.F.= Cylindrical, Female Polyethylene tanks suitable to be fitted with metering pump on its top

Our range of production also includes: SR series: Hydraulic diaphragm dosing pumps B, BR and SD types Mechanical diaphragm dosing pumps FM types Plunger dosing pumps A types PDP series: Positive displacement dosing pump AI and SDI types High pressure positive displacement dosing pump AP-AI types SDP series: Solenoid dosing pumps S type Solenoid dosing pumps GA type H series: Automatic plants for dissolution and preparation of powder polyelectrolytes HA, HB types EM series: Electric mixers for chemical mixing DMT, DEM, DRV and DRC types Distributor: SEALMECH TRADING P.O.Box:113216,DUBAI,UAE Tel:+9714-3371230,Fax;+9714-3373301 e-mail:sealmech@eim.ae,www.sealmech.com HEAD OFFICE Via G. Carducci 141 20093 Cologno Monzese (MI) Italy Tel.: +39 02 27301324 Fax: +39 02 26700883 e-mail: info@doseuro.com www.doseuro.com DOSEURO (UK) LTD. Unit 8, East Road Industrial Estate Sleaford, Lincolnshire NG34 7EH Tel.: +44 1529 300045 Fax: +44 1529 410967 e-mail: info@doseuro.co.uk www.doseuro.co.uk XNME0PCDG000G0207 The right dosing choice