PRODUCT DESCRIPTION N3S

Similar documents
PRODUCT DESCRIPTION N3S

INSTALLATION INSTRUCTIONS MO023A

INSTALLATION INSTRUCTIONS

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

IP-LINX Fiber :: X-XXXX

IP-LINX. Installation Guide

Connectivity accessories by Nestor Cables

Optical Distribution Box 300 Installation Guide. Version : R0.0

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

LANmark-OF ENSPACE Patch Panel

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

HCS - HES Cabling Systems

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

NGF optical distribution frame

3M Distribution Box (DDB)

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

Guide for. Fibre To The Home network constructors

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

RetractaNet XS. Extractable Solutions for OSP. October 2012

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Fiber ICT. Optical Fiber Catalogue

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Cable Installation Tips

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

LGX Compatible (LSX) Connector Module) User Manual)

INSTALLATION INSTRUCTIONS

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Section Communications Optical Fiber Backbone Cabling

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Infinity Fibre Distribution Frame

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

SLiC Fiber Aerial Closure System

Cable Installation Tips

FACT Cable Termination Unit

Original BMW Accessory. Installation Instructions.

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Cable and Power Management Open-Frame Rack Cable Managers

MS 2. Modular Splicing System. Instructions. May A

Medium Box for Cable Termination

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

Channel Cable Tray - Accessories

Cabling and Completing Assembly of the Cisco TelePresence System 1000

3M Coupling Tray FDTC-10S-COUPLINGTRAY

Instruction manual. Midi Fiber Dome. Instruction manual

Bionic Elephant Trunk. Assembly Instructions

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

LANmark. Copper Cabling Solutions

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs

INSTALLATION INSTRUCTIONS

Replacing the Tubes

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

2 Hour Electronic Boost Timer

HI-DEX PRODUCT SET DATASHEET

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

WaveTrax. Fiber Cable Management System

GPON installation in high rise buildings via Fiber Tree system

RACKS, ENCLOSURES AND CABLE MANAGEMENT

Hi-Rez Projections Inc. 20 Main St. Ashland, MA MP8 CRT Installation

2178-L/S Series Fiber Optic Splice Case with Gasket

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

COMBINATION UNITS MARCH 2018

Reference Manual. Notes 9/16 Series H

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Water blocking tape. Locator ridge HPA-0486

STB Distribution Box Screw or IDC Type Indoor DP Outdoor DP Wall & Pole DP Pillar DP

OPTICAL FIBRE CABLE NETWORK 2004/1

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Cable harness for bodywork functions

3 SLiC Aerial Closure with Rubber End Seal

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Building + Mounting Learn Rooftop Basics

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

LCS 2 RJ 45 Cat. 6A HD panels and units

Touch Panel RGB LED Controller Part No. touch-panel-rgb

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

6000 Series Patch Panel Terminating Instructions

Gel-sealed in-line fiber optic closure

Litile34 INSTALLATION MANUAL

Azatrax Model Railroad Track Signal Control - Single Track

Laying of cables and lines in electrical installations and data networks

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Termination Instructions. FO Patch panel OV-A / OV-AT 19 /1U. Cabling Solutions

Public Works Division Lighting District Fiber Optic Specifications April 2009

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Transcription:

PRODUCT DESCRIPTION N3S Nexans N3S ODF system

NEXANS N3S ODF SYSTEM Contents Contents Systems description Patching frame Splice frame Patching module (KB 104/109) Splicing module Accessories Page 2 Page 3-4 Page 5 7 Page 8-9 Page 9 Page 10 Page 11-12 N3S 2012-02-28 2

Nexans Space Saving Solution = N3S N3S is a modular system for terminating a large number of optical fibres in a small floor space. The system consists of patching frame, splice frame (not a splice box on the wall), splice module, patch modules and a complete solution for handling patch cords and cables. Three different sizes of frame are available, 2200 mm, 2000 mm and 1800 mm (the height of the cable ladder is to be added). The 600 mm width and the 300 mm depth are the same for all three heights. Two alternative systems solutions are available. (1) N3S-system S with integrated splice frame and (2) N3Ssystem TS with separately located splice frame. One splice frame + 2 patch frames. 1. The patching frame is equipped with a patch cord ladder (see page 10) for patch cords and cables exiting the frame. The splice frame is connected directly to the patching frame, and is fitted with a cable ladder for cables from the patch modules. Other cables to the splice frame are installed on ladders located in the distribution rooms. 2. The patching frame is fitted with a patch cord ladder (see page 10) for patch cords emerging from the frames. Cables emerging from the frames in the patching modules are positioned in cable ladders located in the node. The cables should be placed behind the patch cord ladder when they leave the frame. In this solution, the splice frame is located in another place (e.g. an adjoining room/cellar). N3S 2012-02-28 3

The patching module, which is precontacted, is available in two sizes, 48 and 96 fibres. The splicing module consists of 8 fold-out cassettes. 96 fibres (fibre ribbons) or 48 single fibres can be spliced in each cassette N3S 2012-02-28 4

Patching frame The inner frame in the patching frame can be pulled out and twisted, for access to work on cables and patch cords. The patch cords are run from the patch module to the side of the inner frame in special guides. The diagram shows an inner frame pulled out and twisted. A specific system must be observed, to avoid creating a tangle of patch cords in the guides. Outgoing patch cords should always be put in the rear compartments of the guides (yellow marking). The patch cords for the two uppermost modules must always be run into the fourth compartment in the guide, counted from the front (red marking) etc. This means that a module can be removed from the inner frame with patch cord without any need to interrupt traffic. Patching frame pulled out and twisted The open design of the top of the frame means that patch cords never need to be threaded through anything at any point. There is a radius restrictor with a spring mechanism on the top sides of the inner frame, which ensures that the patch cords are not damaged when the inner frame is pulled out and rotated. Spring-loaded radius limiter Each patching modules can be installed or removed from a frame by itself, independently of all other patching modules. One or more patching modules can be pulled out of the frame during operation (during fault-finding etc.) thanks to the cable arrangement on the rear of the frame. The cable is laid in a W, using hangers, before it is run out of the patching frame and up onto the patch cord ladder/cable ladder. All outgoing cables and patch cords exit the frame from above. Patching frame seen from rear N3S 2012-02-28 5

There are holes in the top and bottom frames of the frame so that frames can be fixed to walls, side to side, or back to back. No fixing points are needed in the ceiling. All patching frames can be delivered with doors. 2200 mm Depending on the installation system used, the total height of the frame is 2450 mm (TS) or 2550 mm (S), when the patch cord ladder has been fitted. Each patching frame can handle 16 patching modules which contain 96 fibres each. This makes a total of 1536 fibres/frame. With doors without doors Internal patch cords (blue and green) are always 5 metres long, and should be coiled as in the diagram. The length of the red (external) patch cords depends on where the patching frames are located in relation to each other. In this diagram, the length is 11 metres, add an additional 1 metre when modules in the adjoining frame are to be patched, and so on. When active equipment is to be connected, the length depends on where the active frame is located in relation to the N3S frame. In the N3S frame, 5.5 metres is required to reach all patching modules irrespective of where in the frame they are located, and to reach the patch cord ladder. The length required to reach the active equipment is then added. Patching frame seen from front 2000 mm Depending on the installation system used, the total height of the frame is 2250 mm (TS) or 2350 mm (S), when the patch cord ladder has been fitted. Each patching frame can handle 14 patching modules which contain 96 fibres each. This makes a total of 1344 fibres/frame. N3S 2012-02-28 6

Internal patch cords (blue and green) are always 4.5 metre long should be coiled as in the diagram. The length of the red (external) patch cords depends on where the patching frames are located in relation to each other. In this diagram, the length is 10 metres, add an additional 1 metre when modules in the adjoining frame are to be patched, and so on. When active equipment is to be connected, the length depends on where the active frame is located in relation to the N3S frame. In the N3S frame, 5 metres is required to reach all patching modules irrespective of where in the frame they are located, and to reach the patch cord ladder. The length required to reach the active equipment is then added. 1800 mm Depending on the installation system used, the total height of the frame is 2050 mm (TS) or 2150 mm (S), when the patch cord ladder has been fitted Each patching frame can handle 12 patching modules which contain 96 fibres each. This makes a total of 1152 fibres/frame. Internal patch cords (blue and green) are always 4 metres long should be coiled as in the diagram. The length of the red (external) patch cords depends on where the patching frames are located in relation to each other. In this diagram, the length is 9 metres, add an additional 1 metre when modules in the adjoining frame are to be patched, and so on. When active equipment is to be connected, the length depends on where the active frame is located in relation to the N3S frame. In the N3S frame, 4.5 metres is required to reach all patching modules irrespective of where in the frame they are located, and to reach the patch cord ladder. The length required to reach the active equipment is then added. N3S 2012-02-28 7

Splice frame A splice frame can handle the fibres and cables to cover 5 patching frames. This means that a maximum of 40 connection cables (192 fibres) + 80 cables from the patching modules on the patching frames can be handled in one frame. No cable slings are used in the frame. The cables finish off at the top or bottom of the frame, using a cable clamp. The cable clamp for connection cables is fastened in special holders in the frame, see diagram 2. The ribbons from the cable are protected in tubes which each contain 96 fibres/tube. The tubes are fixed by their respective cables' cable clamp. If systems solution S is used, a cable ladder is screwed to the splice frame to lead the cables from the patch modules to the correct attachment point in the rear of the frame. The cables are attached using cable ties. Splice frame, diagram 1 Diagram 2 Cable clamp for connection cables All the tubes are bundled together with the cables from the patching modules, using Velcro tape, and fixed to the frame back panel. Each splicing module is given its own row of tubes which run along the frame back panel. Since the splice module cassettes can be swung out, there is always access to the tubes in the frame. The first splicing module is located 350 mm above/below the holder for the cable grips for outgoing cables. N3S 2012-02-28 8

2200 mm The total height of the frame is 2550 mm when the cable ladder has been fitted The frame has space for 10 splice modules, each of which can handle 768 splices (96 divisible 8-fibre ribbons). The total number of fibres which can be spliced in the frame is 7680. 2000 mm The total height of the frame is 2350 mm when the cable ladder has been fitted The frame has space for 9 splicing modules, which can handle 768 splices each (96 divisible 8-fibre ribbons). The total number of fibres which can be spliced in the frame is 6912. 1800 mm The total height of the frame is 2150 mm when the cable ladder has been fitted The frame has space for 8 splicing modules, which can handle 768 splices each (96 divisible 8-fibre ribbons). The total number of fibres which can be spliced in the frame is 6144. All splice frames can be delivered with doors. With doors without doors Patching modules The connectors are located in pull-out units. Each pull-out unit has a swing-out adapter holder, for access to the inner connectors. Each adapter plate has punched holes so that damaged adapters can easily be changed. If repairs are needed, the entire patching module is pulled out of the frame without needing to undo the patch cords or the indoor cables. If N3S 2012-02-28 9

necessary, one side of the patching module can be unscrewed. 96 fibres The 96-fibre module consists of 6 pull-out units, each with 8 duplex adapters for 16 contacts. 48 fibres The 48- fibre module consists of 3 pullout units, each with 8 duplex adapters for 16 contacts (half the height of the 96-fibre module). In systems solution S, the patch module is supplied preterminated with 20 metres of indoor cable (GAQDBU). With systems solution TS the box is supplied with preterminated connectors with the required length of cable. When splicing cable outdoors or at longer lengths than 70 m ordered GASQBDUV 96 or 48 with the G652D fibres of which are 6 meters closest kk-box only consists of a tube over the ribbons. When splicing indoor and lengths at or below 70 m ordered GAQQDBU with 96 or 48 fibres. Splicing module The splicing module consists of 8 swingout cassettes. Each cassette can handle 96 splices (12 divisible 8-fibre ribbons) or 48 single fibres. The ribbons in the splicing module are long enough to allow splicing to be done with the box still installed in the frame. Splicing module N3S 2012-02-28 10

Accessories Cover When doors are not used, a cover can be fitted, on which any type of marking can be placed. The cover is installed on the patching module and is designed as a hatch. Cover Hangers Hangers can be purchased ready-installed in the frame, but can also be retrofitted as necessary. A frame with few patching modules needs a small number of hangers. Hangers Roll-out ramp A roll-out ramp is required to withdraw the inner frame from the outer frame. There are two rectangular holds at the front of the ramp that act as a stop for the inner frame when it is pulled out. The rollout ramp should be screwed onto the floor, which means 1 ramp/frame. Roll-out ramp Cable clamp for outgoing cable Connection cable terminates in cable grips. The cable grips are mounted either at the top or the bottom of the splice frame. Cable clamp Doors All frames can be installed with doors. Doors N3S 2012-02-28 11

Patch cord ladder S In systems solution S, patch cord ladder 1 is mounted on the frames. The patch cord ladder is used both for outgoing patch cords and for cables associated with the patch modules. Patch cord ladder S Patch cord ladder TS In systems solution TS, patch cord ladder TS is mounted on the frames. The patch cord ladder is used for outgoing patch cords only. In this case, the cables from the patch modules are taken directly to cable ladders located in the distribution room. Patch cord ladder TS Cable ladder When systems solution S is used, the cable ladder is mounted on the splice frame for the cables from the patch modules. No other cables going to the splice frame are positioned on the cable ladder. Cable ladder splice frame Bridge Used on those occasions patching frames placed back to back. Placed on top of the cable ladder TS for guiding the cabling between the frames. Bridge N3S 2012-02-28 12

Nexans IKO Sweden AB 514 81 GRIMSÅS Tfn 0325-800 00 Fax 0325-803 20 www.nexans.se