Control Unit CU 2.1 User Manual V6850A HPLC

Similar documents
SmartMix Manual V5350A

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Operation Manual for the Refractive Index detector VE-3580

Litile34 OPERATION MANUAL

Single cable multiswich programmer PC102W

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

LA1500R USER S GUIDE.

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

SUPPLEMENTARY INFORMATION

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

ICS-3000 System Installation Qualification

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Noise Detector ND-1 Operating Manual

SAT IF distribution system

when it comes to quality! BMR GmbH 1

USER AND INSTALLATION MANUAL ENGLISH SWITCHPACK. PART01245 CONTROL GEAR. rev 01-00

with the Field-IQ Crop Input Control System

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

2-output DALI controller

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

USER S MANUAL

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

USO RESTRITO. WSS Decoder. Option W Version: 2.0 March 20, 2015

GWL/ Power Group Technology Solutions Stay Powered for the Future

STC 160 Head-End Station Quad modulators

Liquid Chromatography- Mass Spectrometer Manual

Printed: File: RI2012 V1.02 english doc Last modified: Makowski

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

LCD Thermometer / Clock S No. 1253

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Integration of the Zetasizer µv and OmniFACE into an SEC system

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Electronic converter for level transmitters MT03L Instructions manual

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Amplifier for fiber optics. Dimensioned drawing

A6 OPERATING INSTRUCTIONS

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Throughout the whole user manual, pay special attention to the following marks that

R&S AMU-Z7 Analog I/Q Combiner Technical Information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Integre4. Audiophile integrated amplifier. v1.2

Sensopress LCD Special English

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

KHT 1000C HV-Probe Calibrator. Instruction Manual

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

If you have questions or problems in providing anything described as Customer

Infra-Red Vortex-Evaporator. User manual Version 3.4

randomrhythm Bedienungsanleitung User Guide

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Ford AMS Test Bench Operating Instructions

Controller, Scheduler-Timer Model UCS-01 version User Guide

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Multi channel programmable Filter-Amplifier

HD-CM HORIZON DIGITAL CABLE METER

OPERATION MANUAL. TECHNOS Co.,Ltd. Total Reflection X-ray Fluorescence Spectrometer

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

CP1 OAD. Owner s Manual. Stereo Control Preamplifier. Ultrafidelity

MT03A Electronic converter for flow rate transmitters

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

SPECIFICATION NO NOTE

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

isync HD & isync Pro Quick Reference Guide isync HD isync Pro Digital Video Processor and Video/Audio Switcher

Panduan Ringkas. Regulatory model T146 P/N 4J.1C DISPERINDAG No. 0287/ /09.03

Gamma instabus. Technical product information

PRO-ScalerV2HD VGA to HDMI & Audio Scaler Converter. User s Guide. Made in Taiwan

MSP 200PRO Quick Start

Multicom Optical Return Path Receiver MUL HRPR 4B

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

HP Presentation Scanner. Quick Reference Guide

VIDEO ALARM VERIFICATION UNIT VIVER

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

Owner s guide How to use your new Opalum Furniture Sound System

O w n e r s M a n u a l

Software Manual Control Panel for Professional Single Booster Units Models: MM3 BW3

SPECIFICATION NO Model 207 Automatic GTAW Welding System

ivw-ud322 / ivw-ud322f

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

UNDER TABLE 4X1 HDMI SWITCHER

INFRACOM. Tray-setup lite for LKC50 Programming Tool. Operating instructions Rev 1.51

CytoFLEX Flow Cytometer Quick Start Guide

Ford AMS Test Bench Operating Instructions

EN - English Washington Street Melrose, MA Phone Toll Free Revision 4 20/06/17

Advanced Test Equipment Rentals ATEC (2832)

Sevenlogic Comfort Timer Switch

Operating instructions

Crown FX PAR 77 LED spotlight. user manual

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

Transcription:

Control Unit CU 2.1 User Manual V6850A HPLC

3 Table of Contents Control Unit... 5 Control... 5 Start Screen... 6 Main Menu... 6 Programs and Links... 7 General Settings... 8 Choosing the Network... 8 Setting the Date and Time... 9 Setting the Leak Sensor... 9 Checking Events...10 Setting the System Wake-Up...10 Reading Out the GLP Data...11 Assistant...12 Changing the Valve Position...12 Choosing the Valve...13 Activating the Column Switching...13 Detector... 14 Activating/Deactivating the Channels...15 Inverting the Signal...15 Initiating an Autozero...16 Resetting the Detector to Default Settings...16 Selecting Reference Wavelength Correction...17 Selecting the Flow Cell...17 Settings in the Setup Menu...18 Pump... 19 Setting the Flow Rate...19 Purging the Pump... 20 Setting the Minimum and Maximum Pump Pressure... 20 Setting the PMax Mode und Maximum Pump Pressure.. 20 Settings in the Setup Menu... 21 Setting the Gradient... 23 High-Pressure Gradient (HPG)... 23

4 Low-Pressure Gradient (LPG)... 23 Solvent Selection Valve... 24 Flushing a Pump with Valve Block... 24 Resetting the Pump to Default Settings... 24 Using the Constant Pressure Mode... 25 P 2.1L... 25 Remote Operation... 27 Scope of Delivery... 27 Declaration of Conformity... 28

Control Unit 5 Control Unit Legend 1 Connector 2 Cable 3 Control Unit 3 1 2 Fig.1 Control Unit The Control Unit is a display with touchscreen functionality that is offered as an optional operating unit for the large devices ("L" devices) of the AZURA product line. The Control Unit controls one AZURA device at a time. To control another device, the Control Unit must be connected to it first. Data transfer between the device and the Control Unit is realized through the firmly installed cable. The moment the cable is connected, the Control Unit starts automatically and reads out the device-specific parameters. After a short while, the status display shows on the start screen. There are two hooks at the top that can be hooked to the housing of each device. Thereby you avoid the Control Unit getting in touch with liquids, which could cause damage to the electronic system. Control You can operate the Control Unit by tapping any grey field or button. The ON button starts the device with the set parameters, which are shown on the start screen. The back button moves one step back or, if pressed longer, back to the start screen. The menu button opens the menu. Use the arrows keys to scroll through the menu level.

6 Control Submits the entered parameters to the device. Start Screen The device-specific start screen shows the set parameters. The top line of the start screen always shows the name of the connected device. Note: Tap on the gray fields to change the parameter shown in that field. In addition to changing the device-specific parameters, the start screen allows you to set events. Events are manually activated or programmed short-circuit contacts. You can program three types of contacts: Inactive contact Active contact Pulse contact Main Menu The main menu includes at least three menus: Setup, GLP, Default parameter (P 6.1L and DAD 6.1L), and Standby. Setup GLP Default parameter The setup menu allows additional settings that go further than the settings from the start screen. GLP refers to "Good Laboratory Practice" which serves a safety check mechanism for the devices. The GLP menu lists all parameters but it does not allow to set parameters. Default parameter resets all settings to default values. The entry has to be confirmed with Yes or No.

Control 7 Standby Each device can be brought to a device-specific standby mode. The Control Unit shuts down, and the screen reads "Standby". To end the standby mode, tap the screen. For the pump P 2.1L, the P 6.1L, and the detector UVD 2.1L, the main menu also includes a Program menu and a Link menu. Programs and Links Altogether, 19 programs and one wake-up program can be stored. Links are used to connect or repeat programs. Altogether, 10 links can be stored. Opens a program for editing, changing, deleting, or adding program lines. Deletes a current program or link. Adds program lines to a program. Shows the program lines of a program.

8 Control General Settings You can find the general settings in the setup menu. Network Date/ Time Leak sensor Event check Wake Up Set the network. Set date and time. Some devices only have the date menu. Activate or deactivate the leak sensor and set its sensitivity. Check the settings of the Event outputs. Set a point in time at which the device restarts automatically. Choosing the Network 1. Tap on the start screen. 2. Tap Setup > Network. 3. Choose network connection. Fig.2 Network configuration

Control 9 Setting the Date and Time 1. Tap on the start screen. 2. Tap Setup Date/Time. 3. Tap the fielddate:. 4. Enter a value for the day and confirm with. 5. Enter month and year and confirm accordingly. 6. Tap to move up one level. 7. Tap the fieldtime:. 8. Enter hour, minute, and second and confirm accordingly. Fig.3 Date Fig.4 Time Setting the Leak Sensor 1. Tap on the start screen. 2. Tap Setup Leak sensor. 3. Tap the field Leak sensorand if necessary change the settings. 4. Tap Sensitivity: tap and select a level of sensitivity Low Medium High. Fig.5 Leak sensor

10 Control Checking Events 1. Tap on the start screen. 2. Tap Setup Event check. 3. Tap the field Active only:. 4. Select the event. Fig.6 Events Setting the System Wake-Up Under Instrument Wake-up, the point of time is set at which the devices in standby switch on automatically. 1. Tap Setup Wake-up. 2. Enter the date and start time respectively. Fig.7 Wake-up

Control 11 Reading Out the GLP Data In the main menu of each device, you find the sub-item GLP. Selecting this item reads out and displays the GLP data of the respective devices. It is possible to display the data of the instrument (Instrument) or single components (Components). Legend 1 Serial number 2 Firmware version 3 Date of installation 4 Last service date 5 Number of operating hours 1 2 3 4 5 Fig.8 GLP data of the pump P 6.1L

12 Assistant Assistant The start screen of the assistant displays which micro devices are integrated as units. Units shown on the start screen are the pumps P 4.1S and P 2.1S, the detector UVD 2.1S, the valve drive V 2.1S, and Vici/Valco valves. They can be operated from the setup menu. Degassers do not have an operating interface and are displayed as empty modules. 1 Valve position 2 Event display 3 Flow rate 4 Pressure 5 Menu button 6 ON button 1 2 Fig.9 Start screen Assistant with valve and pump units 3 4 5 6 This chapter describes how to operate valves. Further information on operating detectors and pumps can be found in the respective chapters. Changing the Valve Position The start screen shows the current valve position. To change the valve position, tap the valve. 1. Tap the valve on the start screen whose position you want to change. 2. Set the valve position. You can either use the arrow keys or tap on the valve position. Fig.10 Valve position Result: The valve position is changed. If there are two identical

Assistant 13 valves installed in the assistant and column switching is activated, the valve positions of both valves are changed simultaneously. Choosing the Valve The correct valve head is factory-set in the setup menu. If you replace a 6-port valve head, you have the option to choose between 2-position valve or multiposition valve. Note: The installed valve head must be compatible with the set valve head in the setup menu. 1. Tap on the start screen. 2. Tap Setup > Valves. 3. Choose valve. Fig.11 Valve selection Activating the Column Switching If two identical multi-position valves are installed in the assistant, column switching can be activated. 1. Tap on the start screen. 2. Tap Setup > Valves. 3. Tap the fieldcolumn switching:. 4. Change the status. Fig.12 Column switching Result: Both valves are switched synchronously.

14 Detector Detector The start screen of the detector shows signal settings and wavelength. The button initiates an autozero. Depending on the number of activated channels, several channels are displayed on the start screen. 1 Signal 2 Autozero button 3 Inverting the signal 4 Wavelength 5 Menu button 6 ON button (UVD 2.1L only) 1 2 Fig.13 Start screen detector Entering the Wavelength 3 4 5 6 1. Tap the wavelength on the start screen. 2. Enter the value for the wavelength. 3. Tap to save the settings. 4. Press the return button to return to the start screen. Fig.14 Wavelength

Detector 15 Entering the Bandwidth For DAD 6.1L, DAD 2.1L, MWD 2.1L it is possible to set a bandwidth for each wavelength. 1. Tap a channel on the start screen. 2. Enter the value of the wavelength. 3. Tap to save the settings. 4. Press the return button to return to the start screen. Fig.15 Bandwidth Activating/Deactivating the Channels With DAD 6.1L, DAD 2.1L, MWD 2.1L it is possible to take several measurements simultaneously. Up to four channels can be activated with the Control Unit. 1. Tap a channel on the start screen. 2. Enter a wavelength and bandwidth for each channel to be activated. 3. Press the return button to return to the start screen. Fig.16 Channel settings window To deactivate channels, tap the wavelength of the channel on the start screen and tap. Inverting the Signal With this setting, the measuring signal can be inverted.

16 Detector 1. Tap on the start screen. 2. Tap. Fig.17 Signal Initiating an Autozero After each solvent change, an autozero should be performed. To do so, tap. The display shows 0,000 AU after the autozero. Resetting the Detector to Default Settings With the Default parameter functionality, the detector can be reset to the factory-set parameters. Since it is possible to change a number of different detector parameters, it is helpful to reset the detector in case problems occur. 1. Tap the menu. 2. Tap Default parameters. 3. Confirm action in separate window. Fig.18 Reset

Detector 17 Selecting Reference Wavelength Correction For DAD 6.1L, DAD 2.1L, MWD 2.1L you can activate or deactivate the reference wavelength correction under Menu Setup Advanced Reference correction. The wavelength as well as the bandwidth can be adjusted. 1. Select a channel. 2. Tap Active to activate the reference wavelength correction. Fig.19 Reference wavelength correction Selecting the Flow Cell For DAD 6.1L, DAD 2.1L, MWD 2.1L, the installed flow cell has to be set. 1. Flow cell tap the flow cell field. 2. Select the installed flow cell. Fig.20 Selecting a flow cell If a fiber optics adapter is used, select Fiber optics in this menu.

18 Detector Settings in the Setup Menu The following menu points are detector specific. Menu Lamps Time Const Intensity Advanced Analog out Analog in Flow cell Fraction Meaning Turn lamp(s) on or off and initialize calibration or validation. Smoothen output signal for analog out. Show light intensity of signal and reference channel (UVD 2.1L only) Wavelength and bandwidth correction (DAD 6.1L, DAD 2.1L, MWD 2.1L) Absorption is documented by external devices depending on voltage. Control wavelength depending on voltage (UVD 2.1L only). Select flow cell (DAD 6.1L, DAD 2.1L, MWD 2.1L) Define fraction collection depending on absorption (UVD 2.1L only).

Pump 19 Pump The status bar under the flow rate in the start screen indicates that the pump is running. 1 Flow rate 2 ON button 3 Pressure 4 Status bar 5 Event display 6 Menu button 1 2 Fig.21 Start screen pump P 2.1L 3 4 5 6 1 Flow rate 2 Composition solvent (SSV) 3 ON button 4 Pressure 5 Status bar 6 Selection solvent (SSV) 7 Event display 8 Menu button 1 4 5 2 6 7 3 8 Fig.22 Start screen pump P 6.1L Setting the Flow Rate 1. Tap the field Flow on the start screen. 2. Enter the value for the flow rate. 3. Tap to save the settings. 4. Keep tapped to return to the start screen and to start the pump from there. Fig.23 Flow rate

20 Pump Purging the Pump To purge the pump, use the field Flow. The set flow rate is not changed by the purging. 1. Open the venting screw to prevent a pressure surge and damage to the column. 2. Tap the field Flow on the start screen. 3. Enter the value for the flow rate. 4. Tap to save the settings. 5. Tap to start the purging process. 6. Tap to stop the purging process. 7. Keep tapped to return to the start screen. Fig.24 Pump Fig.25 Purge Setting the Minimum and Maximum Pump Pressure 1. Tap the field Pressure on the start screen. 2. Enter a value for minimal pressure. 3. Tap to save the settings. 4. Enter a value for maximal pressure. 5. Tap to save the settings. 6. Keep tapped to return to the start screen. Fig.26 Pressure Setting the PMax Mode und Maximum Pump Pressure The PMax Mode functionality protects the column material from strong pressure fluctuations. It regulates the pump's behavior in case the maximum pressure is reached. If the PMax functional-

Pump 21 ity is activated, the pump switches from constant flow operation to constant pressure operation. It continues to convey solvent with the pre-set maximum pressure. One maximum flow rate can be set. The following options can be selected: PMax Mode: Off If the maximum pressure is reached, the pump is stopped. PMax Mode: On Although the maximum pressure has been reached, the pump continues to operate with the pre-set maximum pressure. Settings in the Setup Menu The setup menu for the pump unit in the assistant includes pump head, units, and I-control. Parameter Pump head Gradient Units Meaning Choose pump head. Decide on operating mode HPG, LPG, or isocratic. Not for P 2.1S/P 4.1S. Decide on pressure unit (bar, MPa, psi).

22 Pump Parameter Analog out Analog in Start input I-Control Meaning Pressure is defined by external devices depending on voltage. Not for P 2.1S/P 4.1S. Control flow rate depending on voltage. Not for P 2.1S/P 4.1S. Start/stop loaded programs. External signal sends a command. Enabled: External signal starts a program. Disabled: External signals get ignored. Start pump: Pump starts with set flow rate. Stop pump: Pump runs with set flow rate and can be stopped by external signal. Not for P 2.1S/P 4.1S. Pump stops when maximal pressure has been reached, with maximal pressure being determined by motor voltage. Only for P 2.1S/P 4.1S.

Pump 23 Setting the Gradient The pump can be operated isocratically, as high pressure gradient (HPG) or low pressure gradient (LPG). If the gradient has been set using software, the settings are displayed on the start screen. 1. Tap on the start screen. 2. Tap Setup > Gradient. 3. Choose HPG, LPG, or "none" for isocratic. 4. Keep tapped to return to the start screen. Fig.27 Gradient ISOBAR is used for Constant Pressure Mode. High-Pressure Gradient (HPG) To set up a pump as HPG, the individual pumps have to be set as parts of the HPG. To do so, connect every pump to the Control Unit and set HPG-A for pump A and HPG-B for pump B. Up to four pumps can be set. These settings cannot be made in the P 6.1L menu because this pump is pre-set as HPG, LPG, or isocratic. The settings described are a prerequisite for controlling an HPG system with chromatography software. If two pumps are set as HPG (HPG-A and HPG-B), it is not possible to control them with the Control Unit. Low-Pressure Gradient (LPG) To set up an LPG pump, a valve block with switching valves has to be mounted to the pump head. When working with LPG, the start screen shows the active channels. By tapping the gray fields, the gradient distribution can be entered. For LPG, you can choose between LPG binary with 2 channels and LPG ternary with 3 channels. For analytical pumps there are also quaternary gradients (with 4 channels). If necessary, single channels can be activated/deactivated.

24 Pump Solvent Selection Valve The P 6.1L is equipped with Solvent Selection valves. Solvent Selection valves enable the user to select between 2 solvents per channel of the binary pump. This way, the intake tubes do not have to be changed when the user switches to different solvents. Only a different valve has to be selected. This valve has two inlets (for solvents) and one outlet which is connected directly to the pump head inlet. 1. Tap on the start screen. 2. Tap Setup > Compressibility. 3. Select a combination of channels A1, A2, B1, B2 to choose between different solvents. 4. Keep tapped to return to the start screen. Fig.28 Solvent Selection valve Flushing a Pump with Valve Block 1. Carry out steps 1 5 from the instructions on flushing the pump. 2. Choose channels A, B, C, D, or ABCD to start the flushing process. 3. Tab Purge stop to stop the flushing process. 4. Keep tapped to return to the start screen. Fig.29 Flushing Resetting the Pump to Default Settings With the functionality Default parameter the pump can be reset to default settings. Because a number of different parameters can be set for the pump, it can be helpful to reset to pump to default settings when problems occur.

Pump 25 1. Tap Menu > Default parameter. 2. Tap Yes to confirm resetting the parameters to default settings. 3. Keep tapped to return to the start screen. Fig.30 Default settings Fig.31 Confirm reset Using the Constant Pressure Mode In this mode, the pump pumps with a constant pressure. It is not possible to use gradients. P 2.1L If a valve block is installed, channel A is used for pumping. It is recommended to use the Constant Pressure Mode without a valve block, because this may cause disturbances during operation. Prerequisite Minimum and maximum pressure is set. Flow rate is set.

26 Pump 1. Tap on the start screen. 2. Tap Setup > Gradient. 3. Choose ISOBAR. 4. Keep tapped to return to the start screen. Fig.32 Gradient Target pressure is reached within 15 s. If the target pressure is not reached because the maximum flow rate has been reached before, a note appears on the Control Unit. 1. In the P 6.1L menu, tap Menu Setup Isobar. Fig.33 Isobar 1. In the P 6.1L menu, choose between ON and OFF under the menu item Isobar. Fig.34 Isobar mode

Remote Operation 27 Remote Operation During remote operation, the software controls the devices. The device name is replaced with "Remote" on the screen. All fields are blocked and cannot be operated. Only exception is the button that can be operated even in remote operation and stops the device. The remote screen for the running pump is as follows: 1 Flow rate 2 Status bar 1 3 Button OFF 4 Pressure 2 4 2 3 Fig.35 Remote screen pump Scope of Delivery Control Unit User Manual

28 Declaration of Conformity Declaration of Conformity KNAUER Wissenschaftliche Geräte GmbH Hegauer Weg 38 14163 Berlin, Germany Control Unit CU 2.1L Product number: EZD00 The device complies with the following requirements and product specifications: DIRECTIVE 2006/42/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast) IEC 60799 (1998) Electrical accessories Cord sets and interconnection cords IEC 61010-1 (2011) Safety requirements for electrical equipment for measurement, control and laboratory use Low voltage directive (2006/95/EC) DIN EN 61000-3-2 (2006 + A1:2009 + A2:2009) Electromagnetic compatibility (EMC) Part 3-2 EMC standard (2004/108/EC) IEC 61326-1 (2006) Electrical equipment for measurement, control and laboratory use EMC requirements EN 61326-1 Corrigendum 2 (2011) Directives for an environmentally sound use of electrical and electronic equipment RoHS directives 2002/95/EC (2003) and 2011/65/EU (2012) on the restriction of the use of certain hazardous substances in electrical and electronic equipment WEEE directive 2002/96/EC (2003) on waste electrical and electronic equipment The product was tested with a typical configuration. Alexandra Knauer (CEO & Owner) Berlin, 2014-10-01 The mark of conformity has been applied to the rear panel of the device.

KNAUER Wissenschaftliche Geräte GmbH All rights reserved. The information in this document is subject to change without prior notice.translation of the original German edition of this manual, version 3.1 Last updated: 2015-05-13 Printed in Germany on environmentally friendly paper from sustainable forests. AZURA are registered trademarks of KNAUER Wissenschaftliche Geräte GmbH See up-to-date manuals online: www.knauer.net/downloads HPLC SMB Osmometry KNAUER Wissenschaftliche Geräte GmbH Hegauer Weg 38 14163 Berlin, Germany Phone: +49 30 809727-0 Telefax: +49 30 8015010 E-Mail: info@knauer.net Internet: www.knauer.net www.knauer.net KNAUER 2014 V6850A/0.01/03.14/Koe