MAKE HAZARD ANALYSES BETTER SINGLE-USE DEVICES GAIN PERMANENT PLACE PATH FOR PROCESS SAFETY EMERGES

Similar documents
How to migrate a DCS without a plant shutdown? whitepaper

Live Control System Migrations Redefining Hot Cutovers

Switching Solutions for Multi-Channel High Speed Serial Port Testing

Online Control System Migration of Industrial Centrifuge Project Description

Simple motion control implementation

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

Reducing Waste in a Converting Operation Timothy W. Rye P /F

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Final Exam review: chapter 4 and 5. Supplement 3 and 4

Enhancing Performance in Multiple Execution Unit Architecture using Tomasulo Algorithm

Design for Testability

Click Here To Start Demo

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

System Troubleshooting for

CHAPTER 6 DESIGN OF HIGH SPEED COUNTER USING PIPELINING

Powerful Software Tools and Methods to Accelerate Test Program Development A Test Systems Strategies, Inc. (TSSI) White Paper.

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

Improved Synchronization System for Thermal Power Station

Digital (5hz to 500 Khz) Frequency-Meter

Supervision of Analogue Signal Paths in Legacy Media Migration Processes using Digital Signal Processing

Eagle Business Software

Sharif University of Technology. SoC: Introduction

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Customized electronic part transport in the press shop siemens.com/metalforming

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

PRESS FOR SUCCESS. Meeting the Document Make-Ready Challenge

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Characterization and improvement of unpatterned wafer defect review on SEMs

ZX-44XL Liquid Fuel Analyzer. User s Manual Version 1.2

BER MEASUREMENT IN THE NOISY CHANNEL

StepSequencer64 J74 Page 1. J74 StepSequencer64. A tool for creative sequence programming in Ableton Live. User Manual

NH 67, Karur Trichy Highways, Puliyur C.F, Karur District UNIT-III SEQUENTIAL CIRCUITS

Product Family: DirectLogic PLC Number: AN-MISC-022

1. What does the signal for a static-zero hazard look like?

Synchronization Issues During Encoder / Decoder Tests

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

Optimization of Multi-Channel BCH Error Decoding for Common Cases. Russell Dill Master's Thesis Defense April 20, 2015

Four steps to IoT success

Alcatel-Lucent 5620 Service Aware Manager. Unified management of IP/MPLS and Carrier Ethernet networks and the services they deliver

PEP-I1 RF Feedback System Simulation

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

TELSYS Cable Mapping System

Printed Documentation

Table of Contents. iii

Analog Performance-based Self-Test Approaches for Mixed-Signal Circuits

Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows

NEW APPROACHES IN TRAFFIC SURVEILLANCE USING VIDEO DETECTION

How to Implement PoE in Your Harsh Industrial Environment

Agilent MSO and CEBus PL Communications Testing Application Note 1352

COMPLETE TISSUE PRODUCTION IMPROVEMENT SYSTEM

Design of Fault Coverage Test Pattern Generator Using LFSR

WHITEPAPER. Customer Insights: A European Pay-TV Operator s Transition to Test Automation

Digital Video Engineering Professional Certification Competencies

Why Connecting to the Internet of Things Project List

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

ECG Demonstration Board

THEATRE DESIGN & TECHNOLOGY MAGAZINE 1993 WINTER ISSUE - SOUND COLUMN WHITHER TO MOVE? By Charlie Richmond

Asynchronous inputs. 9 - Metastability and Clock Recovery. A simple synchronizer. Only one synchronizer per input

Comfort System T-32-P Universal Thermostat. Operation Manual

Electronic M.O.P Card. Instruction Manual Model D

HART technology - How to introduce HART into an existing plant

Basic Methods of Length Control Metalcon Andy Allman President AMS Controls

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION

INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN

Barco Smart Laser - High performance cinema projection

Outline. 1 Reiteration. 2 Dynamic scheduling - Tomasulo. 3 Superscalar, VLIW. 4 Speculation. 5 ILP limitations. 6 What we have done so far.

The Newsletter of Delta Automation Inc.

Agile & Lean Movie Making

USCG Exam questions related to PLCs by Frank Owen, Maine Maritime Academy, 23 October 2018

PanelView 1400e CRT Maintenance

Axle Assembly Poke-Yoke

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Optical Technologies Micro Motion Absolute, Technology Overview & Programming

ENGINEERING COMMITTEE

Chapter 12. Synchronous Circuits. Contents

"CHOOSING A STATIC MIXER"

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

ECE 4220 Real Time Embedded Systems Final Project Spectrum Analyzer

Digital Logic Design: An Overview & Number Systems

DCP100 Digital Control Programmer Specifications

TROJANUVTORRENTTM. Drinking Water Disinfection

Microwave Backhaul Solutions SUPER HIGH PERFORMANCE ANTENNAS. Not just a new backhaul solution a whole new backhaul strategy

World Class Converting Xpanded Productivity Platform Xpanded Capabilities State-of-the-Art Ergonomics

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution

Crossing the. Diplex Chasm. to 85 MHz. Author: Todd Gingrass Cable & Media Solutions

SPG700 Multiformat Reference Sync Generator Release Notes

Techniques to Reduce Manufacturing Cost-of-Test of Optical Transmitters, Flex DCA Interface

Retiming Sequential Circuits for Low Power

Upgrading a FIR Compiler v3.1.x Design to v3.2.x

SVT DAQ. Per Hansson Adrian HPS Collaboration Meeting 10/27/2015

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

Power Performance Drill Upgrades. TorqReg. ARDVARC Advanced Rotary Drill Vector Automated Radio Control. Digital Drives Upgrade

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

On the Rules of Low-Power Design

Koester Performance Research Koester Performance Research Heidi Koester, Ph.D. Rich Simpson, Ph.D., ATP

MICROMASTER Encoder Module

TV Synchronism Generation with PIC Microcontroller

Dual Link DVI Receiver Implementation

LA1500R USER S GUIDE.

COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM

Transcription:

MAKE HAZARD ANALYSES BETTER SINGLE-USE DEVICES GAIN PERMANENT PLACE PATH FOR PROCESS SAFETY EMERGES

YOU RE READY. Installation is complete. Your distributed control system (DCS) modernization project nears its end. The control loops of the distillation column have been in manual for the last four hours to allow a hot cutover to the new DCS. The project engineering team said the new controls should work just like the old ones. The operator puts the control loops in the proper mode. Everything looks good initially. Thirty minutes later, though, the key loops on the column start to cycle. Soon, the top and bottom composition (temperature) loops have hit their respective alarm limits, indicating near out-of-spec products. The operator takes manual control trying to recover. It s too late. The overhead and bottom streams have switched to recycle mode. Now the team s focus switches to troubleshooting. This, of course, delays the modernization project and cutover. Risks to both costs and schedule rise. Management looks at you and asks: What just happened? After hours of investigation, the control engineer says that many aspects of the proportional-integral-derivative (PID) control conversion weren t considered when moving from the legacy DCS to the modern automation system. APPRECIATE THE DIFFERENCES Nightmarish stories of modernizations gone wrong might make some people reach for spareparts order sheets to keep their vintage DCS on life support. However, modernizations in chemical processing can and will have happy endings when well planned. Today s DCSs bring benefits that old systems can t match: productivity, process availability and enterprise profit increases to name a few. These are lasting differences that create successful operations. Proper controller tuning paves the way for state-based control algorithms and other high-value functionality. Tools available now for systems provide help with auto tuning and advanced tuning techniques. In addition, knowledgeable control engineers can help with complex problems using the functionality correctly. In fact, controller tuning techniques can be used to minimize impact of any upsets or disturbances in hot cutovers as well as improve control performance after cold cutover startups. Consider that modernization is not just replacing in kind, one for one. Project teams must focus on forward engineering the settings to attain optimal control and process performance. That means concentrating on improvements that are attainable, such as implementing existing functionality with new features to ease use and maintenance. In addition, look at changes with new relatively simple features (e.g., an easily selectable PID structure to reduce process disturbances) that may not have existed in the legacy DCS; these can improve control and reduce variability. Lastly, explore using new embedded supervisory features such as model predictive control (MPC) that can be designed into the project, turned on shortly after the process is up and running, and bring big value to your process. By using a forward engineering methodology, planning for new control requirements and optimizing the new system, a distillation process, for example, could see improvements such as these: 40 80% reduction in quality variation; 5 10% increase in throughput; 0 4% drop in operations and maintenance costs; 10 20% decrease in safety or environmental incident risk; 5 10% cut in energy costs; and 5 10% decline in product inventories by reducing rework and offspecification product. NOT LIKE YESTERDAY S PID Today s PID differs significantly from that of legacy systems. The main reason is that current DCSs have much more power and include many useful control features inside the function blocks. Modernization teams must think about the new functionality in addition to translating functionality from the old to the new system. All this must be done on a tight

Take advantage of some cutover commissioning tips and tricks By Laurie Ben, Aaron Crews and James Beall, Emerson Automation Solutions

FORMS ON SOME LEGACY PLATFORMS Standard Form Platforms Series Form Platforms Both Standard and Series Forms MasterPiece200 INFI-90* Foxboro I/A Damatic Classic MOD 300* TDC 2000/3000 Vision 2000 Micro DCI TI-505 APACS Centrum VP, CS, Micro-XL SPEC 200 Modicon 984 L&N 440, 446-3, Electromax V * Multiple form options available, e.g., series and parallel for INFI-90. Table 1. Many legacy control systems restricted the type of form that could be used. timeline so the organization doesn t lose time or miss profits. Many people today don t realize that PID control algorithms differ from one legacy system to another. Back in the 1970s and 1980s when DCS control became more widespread, control engineers became familiar with the options in their chosen DCS. Today s modern systems usually offer many options in the PID implementation. The conversion of the controller tuning and other PID features depends upon both the legacy system options and those of the new system. The conversion of these nuances and variations tends to show up at inconvenient times like during plant startup after a system modernization. ID YOUR PID First, determine the PID form and structure used by your old DCS. The most common PID forms typically are series or standard, with the difference being in how the derivative action is applied mathematically. Less common is a third form called parallel. The use of different names for the form, e.g., interacting rather than series, can further complicate ascertaining the legacy PID form. An equation or block diagram on the PID function in the legacy system documentation is helpful in confirming the form. The PID structure determines whether the proportional and derivative action is applied to the error or to the process variable (PV) and should be documented for each loop. Next, ascertain the units of the tuning parameters in the legacy system. These can vary widely from system to system and, in some, can be set on a loop-byloop basis (integral time set as seconds, minutes or hours). The options for form, structure and tuning parameter units depend upon the legacy control system implemented and may involve a system-wide selection or a choice for each PID. Modern control systems typically provide both series and standard form options on a per-loop basis; you just need to know which one to choose. Table 1 lists some platforms and what type(s) of form each uses. We recommend that you standardize on one form (typically COSTLY CYCLING RESULTS AFTER CORRECTION Figure 1. For many hours after cutover, the ph cycled dramatically due to an incorrect form being used when moving from the old to the new system. Figure 2. Providing the proper PID form returned ph to control and stopped output cycling.

RELATED CONTENT ON CHEMICALPROCESSING.COM A Strategic Approach for Upgrading Control Systems, Part 1, http://goo.gl/mqccwc A Strategic Approach for Upgrading Control Systems, Part 2, http://goo.gl/buafhu A Strategic Approach for Upgrading Control Systems, Part 3, http://goo.gl/suautk Migration Project Meets Tight Deadline, http://goo.gl/wjcqnf Optimize Control System Migration, http://goo.gl/sb9hyu Migrate Without a Migraine, http://goo.gl/aoybfm the standard) in the new system and properly convert the tuning from the legacy system based on the form and tuning parameter units of the legacy and new systems. Other features that may have been implemented in the previous DCS also require consideration. These might include the structure (error handling), additive or multiplicative feedforward, nonlinear gain options, deadtime compensation and anti-reset windup settings, among many other possibilities. In a recent modernization project, a Provox user was transitioning to a modern DeltaV DCS. The user had 14 fermenters that had been operating well for years. After the cutover of two fermenters, the ph cycled dramatically (Figure 1) unlike before the cutover. Running with this kind of variability on a batch means loss of production and profits, potentially leading to wasted time and expensive chemicals to fix the batch. Obviously, this oversight was costly and delayed production and product delivery. Some detailed engineering early in the project could have easily avoided the problem. What had happened in this case was that a different PID form was selected for the conversion but the units for the tuning parameters weren t taken into account. To correct the problem, the loop was placed in manual, the correct tuning for the selected form was calculated so a download wasn t needed, and the loop then was returned to auto. The ph control performance then dramatically improved (Figure 2). Some visual signs at startup may indicate a problem with the converted tuning or other PID options. For instance, if you notice any of the following, start by looking at the PID tuning and control feature conversions: 1. Cycling controller outputs or PVs when in auto; 2. Loop control that either is super slow, super fast or just different compared to the legacy system; and 3. Loop in control but stabilizing at an offset to the set point. PREVENT COMMON MISTAKES With some forethought, migration teams can plan actions that help avoid startup surprises and regrets. In fact, by relying on control engineers and experts, the solutions can be incorporated into the tools used in the modernization. Know your legacy system conversion form, structure and the tuning parameter units implemented. In some legacy systems, these options are chosen on a system-wide basis, in others on a loop-by-loop basis. Also, understand the options available in the new system. Reference older system documentation to understand how the PID control was implemented. This can be tricky and needs a careful eye. Legacy documentation can be confusing, with words and definitions used inconsistently both within the documentation and between vendor platforms. Use conversion tools to get the mapping right between systems and eliminate manual errors. Some of these tools are readily available from the vendor or can be developed with simple macros within a spreadsheet. Note that the tuning conversion depends upon the form and tuning parameter units for the legacy and new system on each loop. The new system doesn t have to use the same form as the legacy one but this must be taken into account in the tuning conversion. Don t make system-wide assumptions. Each PID block could have a different implementation. Verify all critical loops. Closely examine the top 10 15% of the plant s loops. If converting PLC (programmable logic controller) tuning to DCS, pay extra attention to how PID is implemented. PIDs within a PLC are implemented differently than within a DCS. Scaling, tracking, PV filtering, derivative gain limiting, and velocity or positional algorithms all will impact the PID conversion. TROUBLE-FREE TRANSITION By planning upfront and using some forward-thinking engineering techniques, your modernization can go smoothly for a win-win situation: a win for your team now and a win for your team living with the facility and the new automation system. LAURIE BEN is director of global modernization business development for Emerson Automation Solutions, Round Rock, Texas. AARON CREWS is director of global modernization solutions for Emerson Automation Solutions in Round Rock, Texas. JAMES BEALL is principal process control consultant for Emerson Automation Solutions in Round Rock, Texas. Email them at Laurie.Ben@emerson.com, Aaron.Crews@emerson.com and James.Beall@ emerson.com. Electronic and single printed copies for distribution with permission to Emerson from Chemical Processing December 2017 PUTMAN