Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Similar documents
Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Philips StressVue Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

RF Solution for LED Display Screen

Honeywell HomMed Wireless Scale Quick Reference Guide

GWL/ Power Group Technology Solutions Stay Powered for the Future

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Data Acquisition Instructions

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

IMPORTANT! This instruction guide explains how to install your CCTV system.

Integration of the Zetasizer µv and OmniFACE into an SEC system

Interface sheet - Edan ST-1212 Stress - CPET ergometer

June/July 2016 Med Tips

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

COLOR TFT LCD MONITOR. Manual

22" Touchscreen LED Monitor USER'S GUIDE

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Camera Setup Instructions

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

2 Connect your video source

PXL2760MW LED LCD Monitor

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Med Tips. PRODUCT INFORMATION FreeStyle Battery Warranty. Q: What is the warranty for my FreeStyle Battery?

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

PLL1920M LED LCD Monitor

Modbus for SKF IMx and Analyst

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

2 Connect your video source

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

Amino. Digital Television. Sun City & Hilton Head Island

Installation Note. Agilent 89441A Option AYC Installation Kit

PXL2470MW LED LCD Monitor

Agilent 87075C Multiport Test Set Product Overview

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Ford 6.4L Powerstroke Installation Instructions

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

RADIO FREQUENCY SYSTEMS

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Wall Ball Setup / Calibration

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

Electrocardiogram (ECG) Version Date: 2017-FEB-15 Document Effective Date: 2017-MAY-15

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Safety Precautions and Maintenance

PRECAUTIONS CONTENTS: Please follow these precautions:

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

PLL2210MW LED Monitor

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

Quick Start Guide Building and Scheduling a Show

Cisco 9865H Signal Decoder Troubleshooting Guide

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Setup Guide. Panasonic VX200/VX300/BT300. Plasma Displays. Rev. 1.1

P-2 Installing the monitor (continued) Carry out as necessary

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

Setting up your Roland V-Drums with Melodics.

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

PL2410W LCD Monitor USER'S GUIDE.

TeamWork Kits Installation Guide

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0) on the disk sent with the printer. Follow the steps (see the picture):

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

VNS2200 Amplifier & Controller Installation Guide

Activity P32: Variation of Light Intensity (Light Sensor)

USER MANUAL Full HD Widescreen LED Monitor L236VA

1 Synchronising Xsens with the Delsys Trigno EMG System

Model KT 53 Cooling incubators with thermoelectric cooling

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

NS-3 RF Noise Source Operation Manual

USER MANUAL Full HD Widescreen LED Monitor L215ADS

EEG A1452 SCTE-104 Inserter Frame Card

Winmate Communication INC.

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

TFT LCD USER MANUAL TFT-15 TFT-17 TFT-19

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

2 Connect your video source

UV232A-4S & UV232A-8S 4 or 8 Channel Splitter PC Video, Audio & RS232 over Twisted-Pair

USER MANUAL Full HD Widescreen LED Monitor L215IPS

DXP A0808 Quick Start

Audio Design Associates (ADA)

Transcription:

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes To setup Tango M2 with the Q-Stress cardiac stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with the Q-Stress. This cable enables the Q-Stress to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the Q-Stress display and reports. o SunTech Part Number = 91-0013-01 o Connection Ends: Q-Stress Connection 9 pin female Tango M2 Connection 9 pin female ECG Trigger Cable provides the ECG signal from the Q-Stress to the Tango M2. o SunTech Part Number = 91-0011-01 o Connection Ends: Q-Stress Connection BNC male Tango M2 Connection BNC male Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 1 of 6

Tango M2 Monitor RS-232 Connection Part # 91-0013-01 ECG Trigger Connection Part # 91-0011-01 SunTech Tango M2 BP Monitor TTL (BNC) Cable from Trigger Module Unit Power Cord Microphone Mortara Trigger Module RS232 Data Cable (Com2) or USB connection cable BP Cuff Quinton Q-Stress Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 2 of 6

Mortara Trigger Module ECG Trigger TTL Connection T 2. Connect the RS-232 Cable From: the RS-232 connection on the rear panel of the Tango M2. To: the COM 2 port on the back of the Q-Stress. If a second serial port is not available, a PC board to provide this 2 nd serial port may be required (contact Mortara for details). 3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the TTL output connection on the back of the Mortara M12RFXXX-USB module. *Note If this port is already in use a BNC Splitter may be needed, SunTech Part Number = 64-0080-00. Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 3 of 6

4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. d. Using the UP or DOWN arrows, scroll through the list until X-Scribe is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. Q-Stress V6.x.x System Setup a. After starting a stress test, select the Settings/F1 button to open the Local Settings menu in the Observe phase. Click on the BP Equipment drop down list and select Tango M2. Enter the appropriate COM port value in the Blood Pressure COM Port field. Select OK when finished. b. These settings are remembered for future exams. Note: The Q-Stress Blood pressure entry control for Exercise and Recovery phases will now automatically initiate and acquire BP readings from the SunTech Tango M2 BP Monitor. Mortara Instrument, Inc. Technical Support - (888) MORTARA FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 4 of 6

Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. 2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). 3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 5 of 6

Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Page 6 of 6