Lesson 10 Manual Revision BIOPAC Systems, Inc.

Similar documents
Lesson 14 BIOFEEDBACK Relaxation and Arousal

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Overview. Signal Averaged ECG

Biopac Student Lab Lesson 9 ELECTRODERMAL ACTIVITY & POLYGRAPH Analysis Procedure. Rev

Lesson 9. Physiology Lessons for use with the Biopac Student Lab GALVANIC SKIN RESPONSE & THE POLYGRAPH

Pseudorandom Stimuli Following Stimulus Presentation

BASIC TUTORIAL. Jocelyn Mariah Kremer, Mike Mullins Documentation BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc.

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

Preparation of the participant. EOG, ECG, HPI coils : what, why and how

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

Experiment PP-1: Electroencephalogram (EEG) Activity

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

PRODUCT SHEET

Environmental Controls Laboratory

User Guide EMG. This user guide has been created to educate and inform the reader about doing EMG measurements

Activity P32: Variation of Light Intensity (Light Sensor)

E X P E R I M E N T 1

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

iworx Sample Lab Experiment HM-3: The Electrogastrogram (EGG) and the Growling Stomach

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

SigPlay User s Guide

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Spectrum Analyser Basics

Experiment HM-8: The Electrogastrogram (EGG) and the Growling Stomach

Calibrating the timecode signal input

User Guide Slow Cortical Potentials (SCP)

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Standard Operating Procedure of nanoir2-s

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Spectra/Chrom Chart Recorder from Spectrum Chromatography

Beginners How to Test DSO138mini

Game Show Physiology

Introduction: Overview. EECE 2510 Circuits and Signals: Biomedical Applications. ECG Circuit 2 Analog Filtering and A/D Conversion

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

Biopac Student Lab PRO Manual. Professional Version 3.7.7

Dektak Step by Step Instructions:

Audacity Tips and Tricks for Podcasters

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

User Guide. qeeg NeXus-32. This user guide has been created to educate and inform the reader about doing qeeg measurements with the NeXus-32

HBI Database. Version 2 (User Manual)

PulseCounter Neutron & Gamma Spectrometry Software Manual

THE OPERATION OF A CATHODE RAY TUBE

SedLine Sedation Monitor

ICS Chartr 200 VNG/ENG

PRODUCT SHEET TRANSDUCER MODULE GSR100C

Brain-Computer Interface (BCI)

Quick Start Bruker Dimension Icon AFM

Pre-processing of revolution speed data in ArtemiS SUITE 1

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Activity P27: Speed of Sound in Air (Sound Sensor)

PHY221 Lab 3 - Projectile Motion and Video Analysis Video analysis of flying and rolling objects.

Procedures Guide. Tektronix. HDMI Sink Instruments Differential Impedance Measurement

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

INSTRUMENTATION ESSENTIALS: DIFFERENTIAL AMPLIFICATION

Experiment: Real Forces acting on a Falling Body

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams

TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

Electrocardiogram (ECG) Version Date: 2017-FEB-15 Document Effective Date: 2017-MAY-15

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

The Syscal family of resistivity meters. Designed for the surveys you do.

THE OPERATION OF A CATHODE RAY TUBE

HV/PHA Adjustment (PB) Part

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

How to Set Up Continuous EEG (CEEG)

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Agilent N5431A XAUI Electrical Validation Application

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

OPERATING GUIDE. HIGHlite 660 series. High Brightness Digital Video Projector 16:9 widescreen display. Rev A June A

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

PRODUCT SHEET

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

PRODUCT SHEET

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Quick Reference Manual

HST Neural Coding and Perception of Sound. Spring Cochlear Nucleus Unit Classification from Spike Trains. M.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

The BAT WAVE ANALYZER project

Crane Systems Extension Reel Cable Guide Hardware Kit

BPA Laboratory manual Neil Cronin

SEM- EDS Instruction Manual

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s

DFT-709. Operation Instructions. LCD Color TV Receiver

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

PS User Guide Series Seismic-Data Display

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

Transcription:

Physiology Lessons for use with the Lesson 10 ELECTROOCULOGRAM (EOG) I Eye Movement Saccades and Fixation during Reading Manual Revision 3.7.3 061808 Vertical J.C. Uyehara, Ph.D. Biologist BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc. Horizontal BIOPAC Systems, Inc. 42 Aero Camino, Goleta, CA 93117 (805) 685-0066, Fax (805) 685-0067 Email: info@biopac.com Web: www.biopac.com BIOPAC Systems, Inc.

Page 2 I. INTRODUCTION What do these three things have in common? Two young lovers whose eyes meet across a crowded room The final scene of Casablanca A Michael Crichton novel Regardless of what else they have in common, all involve the muscular control of eye movements in your field of view. One of the most important functions your eyes can perform is to fix or lock on specific objects. When you fix on an object, you position your eyes so that the image of the object is projected onto your retina at the area of greatest acuity, the fovea. Muscular control of your eyes works to keep the image on your fovea, regardless of whether the object is stationary or moving. There are two primary mechanisms used to fixate on objects in your visual field, defined as the field of view without moving your head: 1. Voluntary fixation mechanism Voluntary fixation allows you to direct your visual attention and lock onto the selected object. 2. Involuntary fixation mechanism Involuntary fixation allows you to keep a selected object in your visual field once it has been found. In voluntary types of eye movements, you can fixate on another person from across a crowded room. Voluntary fixation involves a conscious effort to move the eyes. This mechanism is used to initially select objects in your visual field, and once selected, your brain hands off the task to involuntary fixation. Even when you fixate on a stationary object, your eyes are not still but exhibit tiny, involuntary movements. There are three types of involuntary movements: tremors, slow drifts, and flicking: Tremors a series of small tremors of the eyes at about 30-80 Hz (cycles/sec). Slow drifts involuntary movements that result in drifting movements of the eyes. This drift means that even if an object is stationary, the image drifts across the fovea. Flicking movements As the image drifts to the edge of the fovea, the third involuntary mechanism causes a reflex flicking of the eyeball so that the image is once again projected onto the fovea. The drifting movements and flicking movements will be in opposite directions. If the drifting movement is to the left, the flicking movement will be to the right, although it may not be 180 opposite of the drifting movement. When you wish to follow a moving object, you use large slow movements or tracking movements. So, as you watch Humphrey Bogart walk away during the final scene of Casablanca, your eyes are following an apparently smooth motion and tracking an object in your visual field. Although you have voluntarily directed your eyes to Humphrey Bogart, tracking movements are involuntary. Another set of motions is used when you read or when objects are streaming past you, e.g., when you watch the world go by while riding in a train. Rather than a smooth tracking motion, reading usually involves voluntary, larger movements, known as saccades, or fixating on a series of points in rapid succession. When this happens, your eye jumps from point to point at a rate of about three jumps per second. During the jumps or saccades, the brain suppresses visual images, so you don t see the transitional images between the fixation points. Typically, the eye will spend about 10% of the time moving from fixation point to fixation point, with the other 90% of the time fixating on words, although there is much variation. Eye movement can be recorded as an electrooculogram, a recording of changes in voltage that occur with eye position. Electrically, the eye is a spherical battery, with the positive terminal in front at the cornea, and the negative terminal behind at the retina of the eyeball. The potential between the front and back of the eyeball is about 0.4-1.0 mv. By placing electrodes on either side of the eye, you can measure eye movement up to ±70, where 0 is in front and ±90 is directly lateral or vertical to the eyes. The electrodes measure the changes in potential as the cornea moves nearer or further from the recording electrodes. When the eye is looking straight ahead, it is about the same distance from either electrode, so the signal is essentially zero. When the front of the eyeball, the cornea, is closer to the positive electrode, that electrode records a positive difference in voltage.

Lesson 10: EOG I Page 3 II. EXPERIMENTAL OBJECTIVES 1) Compare eye movements while fixated on a stationary object and tracking objects. 2) Measure duration of saccades and fixation during reading. 3) Instructor s option: Record spatial position of eye movements during visual examination of materials. III. MATERIALS BIOPAC electrode lead set (SS2L), Qty-2 BIOPAC disposable vinyl electrodes (EL503), 6 electrodes per subject BIOPAC electrode gel (GEL1) and abrasive pad (ELPAD) or skin cleanser or alcohol prep Adhesive Tape (TAPE 2) Computer system 3.7 BIOPAC data acquisition unit (MP36, MP35, or MP30 with cable and power) IV. EXPERIMENTAL METHODS For further explanation, use the online support options under the Help Menu. A. SET UP FAST TRACK Set Up DETAILED EXPLANATION OF SET UP STEPS 1. Turn the computer ON. The desktop should appear on the monitor. If it does not appear, 2. Make sure the BIOPAC MP3X unit is turned OFF. 3. Plug the electrode leads (SS2L) in as follows: Horizontal lead CH 1 Vertical lead CH 2 ask the laboratory instructor for assistance. Horizontal lead plugs into CHannel 1 Vertical lead plugs into CHannel 2 4. Turn the MP3X Data Acquisition Unit ON. Set Up continues Electrode lead sets (SS2L) Fig. 10.1

Page 4 5. Place 6 electrodes on the Subject as shown in Fig. 10.2. IMPORTANT For accurate recordings, attach the electrodes so they are horizontally and vertically aligned. Right side Left side 6. Attach the vertical electrode lead set (SS2L) from Channel 2 to the electrodes, following Fig. 10.3. Fig. 10.2 Proper electrode placement Attach one electrode above the right eye and one below, such that they are aligned vertically. Attach one electrode to the right of the right eye and one to the left of the left eye, such that they are aligned horizontally. The other two electrodes are for ground, and it is not critical that they are aligned. For optimal electrode adhesion, the electrodes should be placed on the skin at least five minutes before the start of the Calibration procedure. Note: Because these electrodes are attached near the eye, be very careful if using alcohol to clean the skin. Follow Fig. 10.3 to ensure that you connect each colored cable to the proper electrode. It is recommended that the electrode leads run behind the ears, as shown, to give proper cable strain relief. Vertical BLACK lead (Ground) RED lead WHITE lead Right side Left side Lead Placement for Channel 2 (Vertical) Fig. 10.3 Setup continues

Lesson 10: EOG I Page 5 7. Attach the horizontal electrode lead set (SS2L) from Channel 1 to the electrodes, following Fig. 10.4. Follow Fig. 10.4 to ensure that you connect each colored cable to the proper electrode. It is recommended that the electrode leads run behind the ears, as shown, to give proper cable strain relief. BLACK lead (Ground) RED lead WHITE lead Horizontal Right side Left side Lead Placement for Channel 1 (Horizontal) Fig. 10.4 8. Have the Subject adjust the seating position such that his/her eyes are in line with the center of the computer screen. The Subject should be positioned to see the computer screen easily without moving his/her head. Supporting the head to minimize movement is recommended. Connect the electrode cable clip (where the cable meets the three individual colored wires) to a convenient location (can be on the Subject s clothes). This will relieve cable strain. The Subject should not be in contact with nearby metal objects (faucets, pipes, etc.), and should remove any wrist or ankle bracelets. 9. Note the distance from the eyes to the computer screen. 10. Start the BIOPAC Student Lab Program. Note the distance from the eyes to the computer screen, as it will be needed in Recording Step 26. 11. Choose Lesson L10-EOG-1. 12. Type in your filename. Use a unique identifier. 13. Click OK. This ends the Set Up procedure. END OF SET UP

Page 6 B. CALIBRATION The Calibration procedure establishes the hardware s internal parameters (such as gain, offset, and scaling) and is critical for optimum performance. Pay close attention to the Calibration procedure. FAST TRACK Calibration 1. Make sure the Subject is seated in the same position as directed in Set Up Step 8. DETAILED EXPLANATION OF CALIBRATION STEPS Note: It is very important that the Subject does not move his/her head during the calibration procedure. 2. Click Calibrate. After the Calibrate button is pressed, a new window will be established and a dialog box will pop up (Fig.10.5). Fig. 10.5 The journal will be hidden from view during calibration. 3. Prepare for the next step. In the next step, after the OK button is pressed, a dot will begin a counterclockwise rotation around the screen. The Subject is to track the dot with his/her eyes without moving his/her head. 4. Click OK. This will begin the Calibration procedure. 5. Subject should follow the dot on the screen with eyes only. 6. Check the calibration data: If similar, proceed to Data Recording. If different, Redo Calibration. The Subject should follow the dot around the screen with eyes only and should not move his /her head. This procedure will continue for about 10 seconds and will stop automatically. At the end of the 10-sec calibration recording, the screen should resemble Fig. 10.6. END OF CALIBRATION Fig. 10.6 There should be fluctuation in the data for each channel. If your data resembles Fig. 10.6, proceed to the Data Recording section. If the Subject did not follow the dot on the screen or blinked, giving large data spikes or jitter, or if an electrode peeled up, giving large baseline drift, then you should redo the calibration by clicking on the Redo Calibration button and repeating the entire calibration sequence.

Lesson 10: EOG I Page 7 C. RECORDING LESSON DATA FAST TRACK Recording DETAILED EXPLANATION OF RECORDING STEPS 1. Prepare for the recording. In order to work efficiently, read this entire section so you will know what to do before recording. Check the last line of the journal and note the total amount of time available for the recording. Stop each recording segment as soon as possible so you don t use an excessive amount of time (time is memory). Hints for obtaining optimal data: a) Always track the object with your eyes and not your head. b) Subject should focus on one point of the object, and maintain that focus while following it around. c) The Subject needs to sit so that head movement is minimized during recording. d) There should be enough space near the Subject so that an object can be moved around the head at a distance of about 10 (25 cm). e) When moving the object, the Director should try to keep it at the same distance from the Subject s head. f) During recording, the Subject should not blink. If unavoidable, the Recorder should mark the data. g) Make sure electrodes do not peel up. h) The larger the monitor, the better the data results from the eye tracking portion of this lesson. 2. Subject and Director should face each Subject should not be looking at the computer screen. other. 3. Director should hold a pen in front of the Subject. 4. Subject should pick a focal point on the pen so that the eyes remain horizontal. The Director should hold a pen in front of the Subject s head at a distance of about 10 (25 cm). The pen should be centered with the Subject s head, so that the Subject s eyes are looking straight ahead. The Subject s eyes should not move up or down. Ideally, they will only move laterally to follow the object. Recording continues

Page 8 Segment 1 5. Click Record. When you click Record, the recording will begin and an append marker labeled Eyes tracking horizontal will automatically be inserted. 6. Record for 20 seconds. Subject fixates and tracks object. Director holds object center and still for about 5 seconds, then moves object laterally ±70 and back to center in about 3 seconds. Recorder inserts event markers with each change of direction: L for left R for right The Subject should fixate and track the object. Subject should try not to blink during recording, though it may be unavoidable. Director should hold object 10 (25 cm) in front of Subject for about 5 seconds, then move the object laterally to Subject s left, then right, then back to center in about 3 seconds. Director should verbalize the directions so that the Recorder knows when to place markers and what direction to label them. To insert Markers, press the F9 key. Markers and labels can be edited after the data is recorded. 7. Click Suspend. The recording will halt, and you can review the data. 8. Review the data on the screen. If all went well, your data should look similar to Fig. 10.7. If correct, go to Step 10. Fig. 10.7 End of Segment 1 (Horizontal tracking) a) Data should show that the horizontal EOG (CH 1) had large deflections, and the vertical EOG (CH 2) had very little deflection. b) Data should show a positive peak when Subject looked right, and a negative peak when the Subject looked left. If incorrect, go to Step 9. The data would be incorrect if: a) Channel connections were incorrect. b) Lead connections were incorrect (i.e., red lead was not connected to the Subject s right temple.) c) The Suspend button was pressed prematurely d) An electrode peeled up, giving a large baseline drift e) The Subject looked away or the head moved. Note: A few blinks may be unavoidable in the data and would not necessitate redoing the recording. 9. If data was incorrect, click Redo. Click Redo and repeat Steps 2-8. Note that once you press Redo, the data you have just recorded will be erased. Recording continues

Lesson 10: EOG I Page 9 Segment 2 10. Subject and Director should face each other. 11. Director should hold a pen in front of the Subject. 12. Subject should pick a focal point on the pen so that the eyes are looking straight ahead (not up or down). Subject should not be looking at the computer screen. The Director should hold a pen in front of the Subject s head at a distance of about 10 (25 cm). The pen should be centered with the Subject s head, so that the Subject s eyes are looking straight ahead. Subject may need to blink before resuming recording. 13. Click Resume. When you click Resume, the recording will continue and an append marker labeled Eyes tracking vertically will be automatically inserted. 14. Record for 20 seconds. Subject should follow object with eyes only. Director should hold object stationary and center, then move object up, down, and return to center. Recorder should insert event markers: The Subject should follow the object with is/her eyes without moving his/her head. Subject should try not to blink during the recording, although it may be unavoidable. The Director should begin with the object about 10 (25 cm) in front of the Subject for 5 seconds, and move the object vertically to the edge of the Subject s field of vision. To insert Markers, press the F9 key. Markers and labels can be edited after the data is recorded. U Object moved up D Object moved down 15. Click Suspend. The recording should halt, giving you time to review the data. 16. Review the data on the screen. If all went well, your data should look similar to Fig. 10.8. If correct, go to Step 18. Fig. 10.8 Segment 2 Vertical Tracking a) Data should show that the vertical EOG (CH 2) recording had large deflections, and the horizontal EOG (CH 1) had very little deflection. b) Data should show a positive peak when Subject looked up and a negative peak when the Subject looked down. If incorrect, go to Step 17. The data would be incorrect for the reasons from Step 8. 17. If data was incorrect, click Redo. Click Redo and repeat Steps 10-16. Note that once you press Redo, the data you have just recorded will be erased. Recording continues

Page 10 Segment 3 18. Prepare for Segment 3 reading: Director selects reading and positions it in front of Subject. Subject prepares to read. A sample reading is provided at the end of the lesson. Hold the page in front of the Subject at a distance of about 10 (25 cm), centered within his/her line of sight. 19. Click Resume. When you click Resume, the recording will continue and an append marker labeled Reading will be automatically inserted 20. Subject should read for about 20 seconds. Optional: Recorder can insert a marker when Subject starts reading each line. Subject should read silently to minimize EMG artifact. Optional: The Subject may signal the Recorder (verbally or with hand signals) when starting each new line and the Recorder can insert event markers. To insert Markers, press the F9 key. Markers and labels can be edited after the data is recorded. 21. Click Suspend. The recording should halt, giving you time to review the data. 22. Review the data on the screen. If all went well, your data should look similar to Fig. 10.9. If correct, go to Step 24. Fig. 10.9 Segment 3 If incorrect, go to Step 23. The data would be incorrect for the reasons from Step 8. 23. If data was incorrect, click Redo. Click Redo and repeat Steps 18-22. Note that once you press Redo, the data you have just recorded will be erased. 24. Click Stop. When you click Stop, a dialog box comes up, asking if you are sure you want to stop the recording. Clicking yes will end the data recording and automatically save the data. Clicking no will bring you back to the Resume or Stop options. This is simply one last chance to confirm you don t need to redo the last recording segment. Recording continues

Lesson 10: EOG I Page 11 Optional Segment 4 25. If you want to see an example of eye tracking, go to Step 26. or If you want to end the recording, go to Step 31. 26. Reposition the Subject per Set Up Step 8. IMPORTANT The distance from the eyes to the screen must be the same as it was in Set Up. Tracking demonstration Note: This part of the recording is for general interest only and data will not be saved. It shows how well the EOG can be used as an eyetracking device. Have the Subject adjust the seating position such that his/her eyes are in line with the center of the computer screen, and the distance from the eyes to the screen is as recorded. Refer to the distance noted in Set Up Step 9 to ensure that the distance from the Subject s eyes to the screen is the same as was used for the calibration procedure. 27. Click DOT PLOT. A new window will appear, similar to the calibration window. 28. Subject should focus on the center of the screen and move his or her head until the dot is also at the center of the screen. 29. Subject should look at different points within the data window. Subject should maintain this position throughout the DOT PLOT segment. The dot on the screen should track the focal point of the Subject s eyes. Subject should maintain the head position from Step 26, and should look at different points on the screen with eyes only. Note that because of amplifier limitations, the dot can not hold its position for very long and will tend to move toward the center point. 30. Click Stop. When you click Stop, the screen will change to simultaneously display all the dot positions from the last 30 seconds of the dot plot. This segment of data will not be saved. You may redo the dot plot by clicking Redo. 31. Click Done. After you press Done, a pop-up window with options will appear. Make your choice, and continue as directed. If choosing the Record from another Subject option: a) Attach electrodes per Set Up Steps 5-7 and continue the entire lesson from Set Up Step 11. b) Each person will need to use a unique file name 32. Remove the electrodes. END OF RECORDING Remove the electrode cable pinch connectors, and peel off the electrodes. Throw out the electrodes (BIOPAC electrodes are not reusable). Wash the electrode gel residue from the skin, using soap and water. The electrodes may leave a slight ring on the skin for a few hours. This is normal, and does not indicate that anything is wrong.

Page 12 V. DATA ANALYSIS FAST TRACK Data Analysis DETAILED EXPLANATION OF DATA ANALYSIS STEPS 1. Enter the Review Saved Data mode. Enter the Review Saved Data mode from the Lessons menu. Note Channel Number (CH) designation: The data window should come up the same as Fig. 10.10. Channel CH 40 CH 41 Displays horizontal vertical Fig 10.10 2. Setup your display window for optimal viewing of the first data segment. 3. Set up the measurement boxes as follows: Channel Measurement CH 40 CH 40 CH 40 ΔT p-p slope Segment 1 data begins at the append marker labeled Eyes tracking horizontal at Time 0 and continues to the next append marker. The following tools help you adjust the data window: Autoscale horizontal Horizontal (Time) Scroll Bar Autoscale waveforms Vertical (Amplitude) Scroll Bar Zoom Tool Zoom Previous Grids Turn grids ON and OFF by choosing Preferences from the File menu. The measurement boxes are above the marker region in the data window. Each measurement has three sections: channel number, measurement type, and result. The first two sections are pull-down menus that are activated when you click on them. Brief definition of measurements: ΔT: The Delta Time measurement is the difference in time between the end and beginning of the selected area, which is the duration of the selected area. p-p. The p-p (peak-to-peak) measurement shows the difference between the maximum amplitude value in the selected range and the minimum amplitude value in the selected range. slope: uses the endpoints of the selected area to determine the difference in magnitude divided by the time interval; slope indicates the relative speed of eye movement. The selected area is the area selected by the I-beam tool (including the endpoints). Data Analysis continues

Lesson 10: EOG I Page 13 4. Measure the amplitudes and durations for the data section when looking left and right. A Fig. 10.11 shows a sample of data when looking left and right. Fig 10.11 Note: The time interval will vary across subjects. TIP: 5. Zoom in on a small section of the first 5 seconds of Segment 1 data (eye fixation). When interpreting the different bumps in the data, in general: Large vertical bumps are blinks or eyes moving up or down (or when reading, eyes moving to the next line down). Large horizontal bumps are eyes moving left or right (or when reading, eyes moving left to start the next line). Small bumps are saccades (fixations). Zoom in on a section within the first 5 seconds (before the first manuallyinserted event marker) that represents the period when the eyes were fixating straight ahead. 6. Find a part of the data segment with a small spike or bump, indicating flicking movement (Fig. 10.12) and measure the duration and slope. A Use the horizontal scroll bar if needed to find a segment similar to Fig. 10.12. Small bump in data Fig 10.12 Flicking 7. Count the number of flicking movements in one-second intervals from 1-4 seconds. B Table 10.2 Use the horizontal scroll bar to move through the data. The slow drifting movements and flicking movements are small movements, so you will need to Zoom and Autoscale waveforms. The flicking movements will occur as abrupt directional changes (steep slopes) and for shorter durations than the drifting movements. The flicking movements are difficult to measure. If it is too difficult to note them in your data, state that in the Data Report. 8. Set up the measurement boxes as follows: Channel CH 41 CH 41 CH 41 Measurement ΔT p-p slope Data Analysis continues

Page 14 9. Take the measurements on Segment 2 data as needed. C 10. Set up the display window to view Segment 3 Reading data. 11. Find the saccades in the data (Fig. 10.13). D Take measurements in the first five seconds for flicking during fixation. Segment 3 data begins with the append marker labeled Reading. Identify the data section when the Subject moved his/her eyes to read the next line. The horizontal EOG will show the eyes moving left, and at the same time, the vertical EOG will show the eyes moving down. You can paste measurements into the Journal to record the results of each saccade per line of reading. Fig 10.13 12. Save or print the data file. You may save the data to a drive, save notes that are in the journal, 13. Exit the program. END OF DATA ANALYSIS or print the data file. END OF LESSON 10 Complete the Lesson 10 Data Report that follows.

Lesson 10: EOG I Page 15 ELECTROOCULOGRAM EOG DATA REPORT Student s Name: Lab Section: Date: I. Data and Calculations Subject Profile Name Age Height Weight Gender: Male / Female A. Complete Table 10.1 using Segment 1 data. Be careful to be consistent with units (msec vs secs). Note: You only need to select one example of a flicking movement. Table 10.1 Segment 1 Data of Eye Orientation with Object Movement Object Position Stationary Object Moving Object Eye Orientation Fixation Tracking Measurement [CH #] Flicking Left Right Left ΔT [CH 40] p-p [CH 40] slope [CH 40] Note: Velocity may be represented with a negative ("-") value because velocity vectors have a magnitude and direction. B. Complete Table 10.2 using Segment 1 data. Table 10.2 Flicking Movements Time Number of Flicking Movements 0-1 sec 1-2 sec 2-3 sec 3-4 sec

Page 16 C. Complete Table 10.3 using Segment 2 data. Note: You only need to select one example of a flicking movement. Table 10.3 Segment 2 Data of Eye Orientation with Object Movement Eye Orientation Stationary Object Moving Object Tracking Measurement Flicking Up Down Up ΔT [CH 41] p-p [CH 41] Slope [CH 41] D. Complete Table 10.4 with Segment 3 data. (Note: You may not have seven saccades per line.) Table 10.4 Segment 3 Reading data Measurement First Line Second Line Number of saccades Duration of saccade: #1 Total duration of saccades/line Total reading time/line % time of saccades/total reading time #2 #3 #4 #5 #6 #7 II. Questions E. Refer to Table 10.1 data and compare duration (T), relative changes in eye position (Δ), and speed of eye movement (slope) of flicking and tracking movements. F. What is the stimulus for reflex flicking movements? G. Refer to Table 10.3 data and compare duration (T), relative changes in eye position (Δ), and speed of eye movement (slope) of flicking and tracking movements.

Lesson 10: EOG I Page 17 H. Refer to Table 10.3 data and compare your results with at least three others in your class. What is the range of variation in % time of saccades per line? I. Describe three types of involuntary movements during fixation on a stationary object. J. Explain how an electrooculogram is recorded. K. Define visual field. L. Define saccade. End of Lesson 10 Data Report

Page 18

Lesson 10: EOG I Page 19 Sample Reading Saccadic movements jump from place to place. Alas, poor Yorick, I knew him well. What do these three things have in common? Two young lovers whose eyes meet across a crowded room. A Michael Crichton novel. The final scene of Casablanca.