Appendix B. Ballast Cut-sheets

Similar documents
VZT2S54 Electr DMMG Ballast

The right fit for your high-output applications

ILT-54HO-T5C/277 F54T5 HO > 0.98 ILT-39HO-T5C/277 F39T5 HO > 0.98 ILT-24HO-T5C/277 F24T5 HO > 0.

Catalogue Ignitors and power switches for HID

ICN4S5490C2LS35M 4 Light F54 T5 Ho Ballast No Leads

Sign Illuminating Products. Plastic Sign Fluorescent Ballasts HID Sign Ballasts T5, T8, T12 Electronic Ballasts

Sign Illuminating Ballasts

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Electronic Ballast, High Frequency; 2 Lamp(S); 60 W Lamp Wattage; Input Voltage 120/277 V; 50/60 HZ; Parallel Wiring; Can Type Small

I0P2P59SC35I 2-59W T8 120/277V Electronic Ballast

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

OT 100/ /700 P5

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Nova T* Controls. Nova T*

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

15 Series - Dimmer

LED MODULES READYLINE DL

DIN Power Module - Phase Adaptive

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

Instruction Manual Model # Block Upconverter

WLB SERIES HID Lighting for Hose Down Applications

Ariadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

PowPak Dimming Module with 0 10 V- Control

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

INSTALLATION & USER GUIDE

Nova T Controls. Wallbox Controls. Dimmers, Switches, and Accessories

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

Special Order To order, add color/finish suffix code to model number. Example: NT-600-BB Metal Finishes. Special Metal Finishes

Aspect 2 Circuit Digital Scene Control

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Figure 1: Device components

LED Driver Linear / area fixed output

MAP110 AC-DC Series Data Sheet

LED Driver Compact fixed output

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

PowPak Dimming Module with 0 10 V Control

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Series CT7N Bimetallic Overload Relays

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

EXLUX ECOLUX C-LUX 6480 Series

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

clipping; yellow LED lights when limiting action occurs. Input Section Features

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Instruction Manual Model BlockUpconverter

LED Driver Compact fixed output

Manual for WMR-252 built-in receiver with universal dimmer

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Series CDP2 Definite Purpose Contactors

Commercial Lighting Program TECHNICAL SPECIFICATION GUIDE. *Manitoba Hydro is a licensee of the Trademark and Official Mark.

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

PRODUCT DATA SHEET FEATURES

Cyclo Series. user manual. MartinArchitectural

Three Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield

Operating Instructions Dimmer for V Incandescent Lamps

Gamma instabus. Technical product information

Philips InstantFit LED PL-C/T Lamp

llen-bradley 194R-HM4-NFPA3

GENESIS Indoor Air Conditioners

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

Altman Lighting Spectra Cyc 50 Specification

LED control gear Compact fixed output

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

HID control gear Electronic

Modular pulse operated latching relay 16 A

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Filters for Power Lines (Low Leakage Current)

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

SCALE & WEIGHT DISPLAYS

LED Driver Compact dimming

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Telemetry Receiver Installation Guide

Emergency lighting units EM INVERTER

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

GENESIS Indoor Air Conditioners

SceneStyle2 User Guide

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

INNOVATIVE LIGHTING TECHNOLOGY ANNOUNCES THE SMALLEST ONE AND TWO LAMP ELECTRONIC FLUORESCENT BALLLAST AVAILABLE

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

EXLUX ECOLUX 6480 Series

Power Injector 1520 Series

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

Switching Power Module

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

Transcription:

Appendix B ut-sheets

Electrical Specifications VEZ-S3-S Brand Name MARK X POWERLINE Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 77 requency 50/60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (Watts) (min/max) (min/max) MAX % rest 7T8 7 50/0 0.4 3/38 0.05/.05 0 0.99.6.76 5T8 5 50/0 0.0 3/55 0.05/.05 0 0.99.6.9 * 3T8 3 50/0 0.5 5/68 0.05/.00 0 0.99.6.47 B.E.. Wiring Diagram Enclosure DIMMER BLAK WHITE BALLAST RED YELLOW LAMP LINE LAMP The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 9.50 ".7 ".8 " 8.90 " 9 / 7/0 9/50 8 9/0 4. cm 4.3 cm 3 cm.6 cm Revised 0/8/005 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL

64UNVxxx APPLIATION and PERORMANE SPEIIATION Description: Electronic compact fluorescent ballast(s) for () M4W/GX4q or () TR3W/GX4q or (/) Q/TR6W/GX4q or () T4/7W/G or () S8W/GR0q (D) 4-pin lamps or () 9T5-W or () T5-40W or () S38W/GR0q or () M36W/G0 Line Voltage: 0vac to 77vac, ±0%, 50-60Hz Programmed Rapid Start High Series onnection Line Nominal rest Model Volts Type # Watts* Line Amps 64UNV 64UNV 64UNV 64UNV 64UNV 64UNV 64UNV 64UNV 64UNV 64UNV 0 0 0 0 0 0 0 0 0 0 Q/TR6W Q/TR6W M4W TR3W T4/7W/G S8W/GR0q 9T5-W T5-40W S38W/GR0q M36W/G0 56 8 48 36 30 3 5 4 33 3 0.47 0.5 0.4 0.30 0.6 0.7 0. 0.35 0.7 0.7.98.0.98.00.90.95.00.98.80.98 > 0.95 > 0.95 > 0.95 < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% <.5 <.5 <.5 <.5 <.6 <.6 <.5 <.5 <.6 <.7 77 77 77 77 77 77 77 77 77 77 Q/TR6W Q/TR6W M4W TR3W T4/7W/G S8W/GR0q 9T5-W T5-40W S38W/GR0q M36W/G0 56 8 48 36 30 3 5 4 33 3 0. 0. 0.8 0.3 0. 0. 0.0 0.6 0. 0..98.0.98.00.90.95.00.98.80.98 > 0.95 > 0.95 > 0.95 < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% < 0% <.5 <.5 <.5 <.5 <.6 <.6 <.5 <.5 <.6 <.7 * ANSI measured wattage; 5 ambient; benchtop; lamps base up Application and Performance Specification Information Subject to hange without Notification. Performance: Safety: Meets ANSI Standard 8. No PB's Meets Part 8 (Non-onsumer), Limits for EMI/RI UL listed (lass P) Operating requency Range: Above 60 khz Type Outdoor, Type, Type HL Auto-Reset Shutdown ircuit per NEMA Recommendations SA ertified - Both lamps should be replaced at end of life - relights upon insertion in socket Suitable for use in air handling spaces when NE wiring guidelines are followed ME version: Terminals L N G intended for one supply connection only Application: Physical Parameters Minimum Starting Temperature: 0, -8 Overall Length: 4.94" Maximum ase Temperature (@ t c ): 67, 75 Width:.3" Sound Rated: A Mounting: 4.6" Lead configuration: Height:.00" xxx = SE - Side Exit (Also available with socket) Weight: 0.57 lbs or BE - Bottom Exit Qty/arton: 0 or BES - Bottom Exit with Studs (" on center) olor: SE-White or ME - Multi-Exit Replacement Kit for Distribution BE/BES-Black Remote Mounting feet ME-White Also operates on 5VD input, (+)L (-)N an Material: Metal Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 5 years from date of manufacture when properly installed and under normal conditions of use. all -800-BALLASTx800 for technical assistance. - Manufactured in North America - has plug in wire trap connectors. - Use 8 AWG solid copper wire, stripped to 3/8". - must be grounded in accordance with national and local electrical codes. Black White One Application Reds Blues Black White Two Application Reds Yellows Blues Black White One Application Red Red Blue Blue -800-BALLAST www.universalballast.com ebruary 006 Universal # BAL

Electrical Specifications VL-B3-TP-BLS Brand Name OMPAT-NP Type Magnetic Starting Method Pre-Heat onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) Starting Open ircuit (Watts) MAX % Q3W/GX3 3 0/-8 0.4 0.8 0.00 4 0.98 0 0.36 * T3W/GX3 3 0/-8 0.6 0.8 0.00 0 0.98 5 0.8 Wiring Diagram Enclosure WHITE LINE BLK/WHT AP OPTIONAL BALLAST H W M L Diag. 45 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 0 Blue 7 7.8 Red 0 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 7 7.8 Red/White 0 Enclosure Dimensions ASE "R" OverAll (L) Width (std)/(tp) Height (H) Mounting (M) 4.75 ".875 "/0 ".65 " 4.375 " 4 3/4 7/3 / 0 5/8 4 3/8. cm 5.6 cm / 0 cm 4. cm. cm Revised 07/0/999 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL3

R luorescent Dimming s Hi-lume Overview Hi-lume % Architectural Dimming Hi-lume () 07.08.04 Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industryleading performance with true full-range 00% to % fluorescent dimming, Hi-lume ballasts enable you to provide the ideal visual environment for any application. Hi-lume, case type A 3.00 w (76mm) x.00 h (5mm) x 4.90 l (4mm) eatures ontinuous, flicker-free dimming from 00% to % Standard 3-wire line-voltage phase-control technology for consistent fixture-to-fixture dimming performance Models available for T4 triple-tube compact, T5-HO linear, and T8 lamps Programmed rapid start design preheats lamp cathodes before applying full arc voltage s turn on to any dimmed level without flashing to full brightness Low harmonic distortion throughout the entire dimming range maintains power quality requency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 4 khz Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay failure End-of-lamp-life protection circuitry (for T4 and T5-HO models) ensures safe operation throughout entire lamp life cycle or linear lamps, ballasts maintain consistent light output for different lamp lengths, ensuring fixture uniformity Ultra-quiet operation Protected from miswires of any input power to control lead, or from lamp leads to each other and/or ground 00% compatible with all Lutron 3-wire fluorescent controls 00% performance tested at factory Hi-lume, case type.8 w (30mm) x.00 h (5mm) x 8.00 l (457mm) Hi-lume, case type.38 w (60mm) x.50 h (38mm) x 9.50 l (4mm) Designed and assembled in the USA 5-year limited warranty with Lutron field service commissioning (3-year standard warranty) from date of purchase Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL4

R luorescent Dimming s Specifications Hi-lume % Architectural Dimming Hi-lume () 07.08.04 Performance Dimming Range: 00% to % measured relative light output (RLO) Starting: programmed rapid start Minimum Starting Temperature: 0 (50 ) Ambient Temperature Operating Range: 0 (50 ) to 60 (40 ) Relative Humidity: maximum 90% noncondensing Operating Voltage: 0V or 77V at 60Hz rest : less than.7 licker: none visible Light Output Variation: constant ±% light output for line voltage variations of ±0% Life: average lamp life meets or exceeds rating of lamp manufacturer : greater than.85 for T8 lamps, greater than.95 for T4 lamps, equal to.0 for T5-HO lamps : greater than.95 Total Harmonic Distortion (): less than 0% Maximum Inrush : 7 amps per ballast at 0V, 3 amps per ballast at 77V Sound Rating: Inaudible in a 7dBa ambient Maximum ase Temperature: 75 (67 ) Standards UL Listed (evaluated to the requirements of UL935) SA certified (evaluated to the requirements of. No. 74) lass P thermally protected Meets ANSI 8. High requency Standard Meets Part 8 Non-onsumer requirements for EMI/RI emissions T4 and T5-HO ballasts are MIL Std. 46E compliant (meets the requirements of E0, RE0 and RE0) Meets ANSI 6.4 ategory A surge protection standards up to and including 6kV Manufacturing facilities employ ESD reduction practices that comply with the requirements of ANSI/ESD S0.0 Lutron Quality Systems registered to ISO 900.000 Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL4

R luorescent Dimming s Hi-lume Models Hi-lume % Architectural Dimming Hi-lume (3) 07.08.04 0 VOLTS 77 VOLTS Type Watts (length) s per ballast ase Type (amps) Hi-lume Model Number (amps) Hi-lume Model Number T4 triple-tube 4-pin 6W A.6 HL3-T46-0--S. HL3-T46-77--S 3W A.3 HL3-T43-0--S.3 HL3-T43-77--S / diameter T5-HO linear high output 4W (.5 ).6.45 DB-T54-0- DB-T54-0-.3.0 DB-T54-77- DB-T54-77- 39W (33.4 ).38.76 DB-T539-0- DB-T539-0-.7.3 DB-T539-77- DB-T539-77- 5/8 diameter 54W (45.3 ).58. DB-T554-0- DB-T554-0-.5.45 DB-T554-77- DB-T554-77- T8 linear and U-bent 7W (4 ) 3.9.3.43 DB-47-0- DB-47-0- DB-47-0-3.08.5.0 DB-47-77- DB-47-77- DB-47-77-3 diameter 5W (36 ) 3.4.43.6 DB-367-0- DB-367-0- DB-367-0-3..9.8 DB-367-77- DB-367-77- DB-367-77-3 3W (48 ) 3.30.57.8 DB-487-0- DB-487-0- DB-487-0-3.4.5.35 DB-487-77- DB-487-77- DB-487-77-3 40W (60 ).36.64 DB-607-0- DB-607-0-.6.30 DB-607-77- DB-607-77- T linear HO (800ma) ½ diameter 85W (7 ) 95W (84 ) 0W (96 ).75 DB-780-0- - - - -.83 DB-8480-0- - - - -.88 DB-9680-0- - - - - Mounting studs standard for T4 ballasts. Delete suffix -S in the model number if mounting studs not needed. Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL4

Electrical Specifications VEZ-T4-M3-BS Brand Name MARK X line Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (Watts) MAX % rest TR3W/GX4Q 3 50/0 0.8 0 0.05 0 0.98.6 0.5 * TR4W/GX4Q 4 50/0 0.36 0 0.05 0 0.98.6 0.5 TR57W/GX4Q 57 50/0 0.4 8 0.05 0 0.98.6 0.8 TR70W/GX4Q 70 50/0 0.9 8 0.05 0 0.98.6 0.8 B.E.. Wiring Diagram Enclosure DIMMER BLAK WHITE BALLAST RED RED YELLOW YELLOW LINE DIAG. 3 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 6.8 " 3.00 ".9 ".00 " 6 7/5 3 9/00 6 cm 7.6 cm 3.3 cm 5. cm Revised 09/0/00 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL5

Electrical Specifications VEZ-3-S Brand Name MARK X POWERLINE Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 77 requency 50/60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (Watts) (min/max) (min/max) MAX % rest 7T8 7 50/0 0.09 07/4 0.05/.05 0 0.99.6 4.38 5T8 5 50/0 0. 07/30 0.05/.05 0 0.99.6 3.50 * 3T8 3 50/0 0.3 09/35 0.05/.00 0 0.99.6.86 B.E.. Wiring Diagram Enclosure DIMMER BLAK/ WHITE WHITE BALLAST RED LINE The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 9.50 ".7 ".8 " 8.90 " 9 / 7/0 9/50 8 9/0 4. cm 4.3 cm 3 cm.6 cm Revised 0/8/005 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL6

Electrical Specifications IDL-S6-M5-BS@77 Brand Name ROVR Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 0-77 requency 50/60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (Watts) (min/max) (min/max) MAX % rest * Q3W/G4Q 3 50/0 0.07 06/8 0.03/.00 0 0.99.6 5.56 Q3W/G4Q 3 50/0 0. 09/3 0.03/.00 0 0.99.6 3.3 B.E.. Wiring Diagram Enclosure The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 0 White 0 0 Blue 0 0 Red 0 0 Yellow 0 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 0 Red/White 0 Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 4.98 " 3.00 ".8 ".00 " 4 49/50 3 9/50.6 cm 7.6 cm 3 cm 5. cm Revised /03/003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL7

R luorescent Dimming s Hi-lume Overview Hi-lume % Architectural Dimming Hi-lume () 07.08.04 Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industryleading performance with true full-range 00% to % fluorescent dimming, Hi-lume ballasts enable you to provide the ideal visual environment for any application. Hi-lume, case type A 3.00 w (76mm) x.00 h (5mm) x 4.90 l (4mm) eatures ontinuous, flicker-free dimming from 00% to % Standard 3-wire line-voltage phase-control technology for consistent fixture-to-fixture dimming performance Models available for T4 triple-tube compact, T5-HO linear, and T8 lamps Programmed rapid start design preheats lamp cathodes before applying full arc voltage s turn on to any dimmed level without flashing to full brightness Low harmonic distortion throughout the entire dimming range maintains power quality requency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 4 khz Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay failure End-of-lamp-life protection circuitry (for T4 and T5-HO models) ensures safe operation throughout entire lamp life cycle or linear lamps, ballasts maintain consistent light output for different lamp lengths, ensuring fixture uniformity Ultra-quiet operation Protected from miswires of any input power to control lead, or from lamp leads to each other and/or ground 00% compatible with all Lutron 3-wire fluorescent controls 00% performance tested at factory Hi-lume, case type.8 w (30mm) x.00 h (5mm) x 8.00 l (457mm) Hi-lume, case type.38 w (60mm) x.50 h (38mm) x 9.50 l (4mm) Designed and assembled in the USA 5-year limited warranty with Lutron field service commissioning (3-year standard warranty) from date of purchase Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL8

R luorescent Dimming s Specifications Hi-lume % Architectural Dimming Hi-lume () 07.08.04 Performance Dimming Range: 00% to % measured relative light output (RLO) Starting: programmed rapid start Minimum Starting Temperature: 0 (50 ) Ambient Temperature Operating Range: 0 (50 ) to 60 (40 ) Relative Humidity: maximum 90% noncondensing Operating Voltage: 0V or 77V at 60Hz rest : less than.7 licker: none visible Light Output Variation: constant ±% light output for line voltage variations of ±0% Life: average lamp life meets or exceeds rating of lamp manufacturer : greater than.85 for T8 lamps, greater than.95 for T4 lamps, equal to.0 for T5-HO lamps : greater than.95 Total Harmonic Distortion (): less than 0% Maximum Inrush : 7 amps per ballast at 0V, 3 amps per ballast at 77V Sound Rating: Inaudible in a 7dBa ambient Maximum ase Temperature: 75 (67 ) Standards UL Listed (evaluated to the requirements of UL935) SA certified (evaluated to the requirements of. No. 74) lass P thermally protected Meets ANSI 8. High requency Standard Meets Part 8 Non-onsumer requirements for EMI/RI emissions T4 and T5-HO ballasts are MIL Std. 46E compliant (meets the requirements of E0, RE0 and RE0) Meets ANSI 6.4 ategory A surge protection standards up to and including 6kV Manufacturing facilities employ ESD reduction practices that comply with the requirements of ANSI/ESD S0.0 Lutron Quality Systems registered to ISO 900.000 Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL8

R luorescent Dimming s Hi-lume Models Hi-lume % Architectural Dimming Hi-lume (3) 07.08.04 0 VOLTS 77 VOLTS Type Watts (length) s per ballast ase Type (amps) Hi-lume Model Number (amps) Hi-lume Model Number T4 triple-tube 4-pin 6W A.6 HL3-T46-0--S. HL3-T46-77--S 3W A.3 HL3-T43-0--S.3 HL3-T43-77--S / diameter T5-HO linear high output 4W (.5 ).6.45 DB-T54-0- DB-T54-0-.3.0 DB-T54-77- DB-T54-77- 39W (33.4 ).38.76 DB-T539-0- DB-T539-0-.7.3 DB-T539-77- DB-T539-77- 5/8 diameter 54W (45.3 ).58. DB-T554-0- DB-T554-0-.5.45 DB-T554-77- DB-T554-77- T8 linear and U-bent 7W (4 ) 3.9.3.43 DB-47-0- DB-47-0- DB-47-0-3.08.5.0 DB-47-77- DB-47-77- DB-47-77-3 diameter 5W (36 ) 3.4.43.6 DB-367-0- DB-367-0- DB-367-0-3..9.8 DB-367-77- DB-367-77- DB-367-77-3 3W (48 ) 3.30.57.8 DB-487-0- DB-487-0- DB-487-0-3.4.5.35 DB-487-77- DB-487-77- DB-487-77-3 40W (60 ).36.64 DB-607-0- DB-607-0-.6.30 DB-607-77- DB-607-77- T linear HO (800ma) ½ diameter 85W (7 ) 95W (84 ) 0W (96 ).75 DB-780-0- - - - -.83 DB-8480-0- - - - -.88 DB-9680-0- - - - - Mounting studs standard for T4 ballasts. Delete suffix -S in the model number if mounting studs not needed. Job Name: SPEIIATION SUBMITTAL Model Numbers: Page Job Number: Lutron # BAL8

Electrical Specifications VN-M3-M Brand Name ENTIUM MIRO AN Type Electronic Starting Method Instant Start onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (ANSI Watts) MAX % MAX rest T5 50/0 0.8 50.0 0 0.98.7.0 5T8 5 0/-8 0.8 49 0.88 0 0.99.7.80 8T5 8 50/0 0. 60 0.98 0 0.99.7.63 * 3T8 3 0/-8 0. 59 0.88 0 0.99.7.49 3T8/ES (30W) 30 60/6 0.0 54 0.88 0 0.99.7.63 B.E.. Wiring Diagram Enclosure WHITE BLAK RED BALLAST LINE LAMP LAMP Diag. 64 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 5L 63.5 Blue 3R 78.7 Red 37L 94 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 5L 63.5 Red/White 0 Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 9.50 ".08 ".05 " 8.9 " 9 / /5 /0 8 9/00 4. cm.7 cm.7 cm.6 cm Revised 07/3/004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL9

Electrical Specifications VN-3-M Brand Name ENTIUM MIRO AN Type Electronic Starting Method Instant Start onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (ANSI Watts) MAX % MAX rest T5 50/0 0.0 7.0 0 0.98.7 4.07 5T8 5 0/-8 0.09 5 0.98 0 0.98.7 3.9 * 8T5 8 50/0 0. 30 0.98 0 0.99.7 3.7 3T8 3 0/-8 0. 30 0.98 0 0.98.7 3.7 3T8/ES (30W) 30 60/6 0.0 8 0.98 0 0.98.7 3.50 B.E.. Wiring Diagram Enclosure WHITE BLK/WHT RED BALLAST LINE LAMP Diag. 63 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 5L 63.5 Blue 3R 78.7 Red 37L 94 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 5L 63.5 Red/White 0 Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 9.50 ".08 ".05 " 8.9 " 9 / /5 /0 8 9/00 4. cm.7 cm.7 cm.6 cm Revised 07/3/004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL0

0.3" X 0.53 4 SLOTS.8" 0.5" WIDE SLOTS 3.90".65" apacitor: 760M33 4 /4 X 5 3/4 ORE - OIL UNIT 7.75" 6.75" 5.75" 7.5" 6.5" 5.75" 5.40" 4.40" 4.5" atalog Number 7A0740 Low Pressure or 80W L74 Sodium 60 Hz HX-HP Status: Active DIMENSIONS AND DATA 0.8" 0.5".75" A 0.9" B MAX. 8 HOLES LEARED OR #0 THRU-BOLTS 4.35" INPUT VOLTS 480 IRUIT TYPE POWER ATOR (min) HX-HP 90% REGULATION Line Volts Watts ±5% ±0% LINE URRENT Operating... 0.44 Open ircuit....30 Starting... 0.55 UL TEMPERATURE RATINGS Insulation lass oil Temperature ode H(80 ) 09 A MIN. AMBIENT STARTING TEMP. NOM. OPEN IRUIT VOLTAGE -0 or -30 685 INPUT VOLTAGE AT LAMP DROPOUT... 340 INPUT WATTS 06 REOMMENDED USE... 4 ORE and OIL Dimension (A) Dimension (B) Weight (lbs.) Lead Lengths.40 4.00 6.5 " APAITOR REQUIREMENT Microfarads Volts (min.) 6.0 330 ault Withstand (amps) 60 Hz TEST PROEDURES (Refer to Advance Test Procedure for HID s - orm 70) High Potential Test (Volts) minute seconds Open ircuit Voltage Test (Volts) 000 500 60-760 Short-ircuit Test Secondary 0.90-.0... 0.0 - - - - 0.30 Wiring Diagram: Ignitor: NA apacitance: 6 Dia/Oval Dim:.5 Height: 3.75 Temp Rating: 05 OM AP AP LINE V LINE V LINE V LAMP LAMP OM OM This ballast does not require the use of an ignitor. Order Suffix ig. Q Ordering Information Description Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 03/8/0 BAL

e-vision Electronic for Metal Halide s atalog Number IMH-50-A or () 39W ANSI M30 or () 50W ANSI M0 Metal Halide 0-77V 50/60Hz Electronic Status: Active Data Number Watts Volts atalog Number* Line DIMENSIONS AND DATA (W) Max (%) Min Wiring Dia igure Weight (lb) Max Distance to (ft) 39 Watt, ANSI ode M30 Minimum Starting Temp -30 /-0 39 0 IMH-50-A-xxx 0.38 45.0 5 0.9 A.4 5 77 0.6 44 50 Watt, ANSI ode M0 Minimum Starting Temp -30 /-0 50 0 IMH-50-A-xxx 0.47 56 77 0.0 55.0 5 0.9 A.4 5 igure A Wiring Diagram ASE LENGTH = 4.7" [0mm] MOUNTING LENGTH = 5.0" [3mm] MOUNTING WIDTH =.87" [73mm] OVERALL LENGTH = 5.5" [40mm] ASE WIDTH = 3.6" [9mm] HEIGHT =.50" [38mm] MEASURE ASE TEMPERATURE ON RIGHT HEAT SINK LIP AT BALAST END Wiring Diagram ase Temperature Measurement Location INSTALLATION & APPLIATION NOTES:. Maximum allowable case temperature is 85. See figure above for measurement location. Ignition pulse is 4 kv max 3. All leads are inches long 4. output will shutdown after 0 minutes if lamp fails to ignite 5. must be cycled off then on, after replacing lamp Order Suffix -L -BLS *Ordering Information Description with side exit leads and mounting feet with bottom exit leads and mounting studs Data is based on tests performed by Advance transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Advance 075 West Higgins Road Rosemont, Illinois 6008-5603 (847) 390-5000 fax: 847-390-509 www.advancetransformer.com A DIVISION O PHILIPS ELETRONIS NORTH AMERIA ORPORATION 0///05 BAL

Electrical Specifications VL-B9-TP-BLS Brand Name OMPAT-NP Type Magnetic Starting Method Pre-Heat onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) Starting Open ircuit (Watts) MAX % Q9W/G3 9 0/-8 0.6 0.8 0.00 5 0.90 0 0.33 T5W/G3 5 0/-8 0.7 0.8 0.00 0.96 5 0.5 T7W/G3 7 0/-8 0.7 0.8 0.00 4 0.95 5 0.9 * T9W/G3 9 0/-8 0.7 0.8 0.00 4 0.9 5 0.3 Wiring Diagram Enclosure WHITE LINE AP OPTIONAL LAMP BLK/WHT BALLAST H W M L Diag. 4 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 0 Blue 7 7.8 Red 0 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 7 7.8 Red/White 0 Enclosure Dimensions ASE "R" OverAll (L) Width (std)/(tp) Height (H) Mounting (M) 4.75 ".875 "/0 ".65 " 4.375 " 4 3/4 7/3 / 0 5/8 4 3/8. cm 5.6 cm / 0 cm 4. cm. cm Revised 09/4/999 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL3

Electrical Specifications VL-B3-TP-BLS Brand Name OMPAT-NP Type Magnetic Starting Method Pre-Heat onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) Starting Open ircuit (Watts) MAX % * Q3W/GX3 3 0/-8 0.4 0.8 0.00 4 0.98 0 0.36 T3W/GX3 3 0/-8 0.6 0.8 0.00 0 0.98 5 0.8 Wiring Diagram Enclosure WHITE LINE BLK/WHT AP OPTIONAL BALLAST H W M L Diag. 45 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 0 Blue 7 7.8 Red 0 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 7 7.8 Red/White 0 Enclosure Dimensions ASE "R" OverAll (L) Width (std)/(tp) Height (H) Mounting (M) 4.75 ".875 "/0 ".65 " 4.375 " 4 3/4 7/3 / 0 5/8 4 3/8. cm 5.6 cm / 0 cm 4. cm. cm Revised 07/0/999 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL4

Electrical Specifications VN-M3-M Brand Name ENTIUM MIRO AN Type Electronic Starting Method Instant Start onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (ANSI Watts) MAX % MAX rest T5 50/0 0.8 50.0 0 0.98.7.0 5T8 5 0/-8 0.8 49 0.88 0 0.99.7.80 * 8T5 8 50/0 0. 60 0.98 0 0.99.7.63 3T8 3 0/-8 0. 59 0.88 0 0.99.7.49 3T8/ES (30W) 30 60/6 0.0 54 0.88 0 0.99.7.63 B.E.. Wiring Diagram Enclosure WHITE BLAK RED BALLAST LINE LAMP LAMP Diag. 64 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) in. cm. Black 0 White 5L 63.5 Blue 3R 78.7 Red 37L 94 Yellow 0 Gray 0 Violet 0 in. cm. Yellow/Blue 0 Blue/White 0 Brown 0 Orange 0 Orange/Black 0 Black/White 5L 63.5 Red/White 0 Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 9.50 ".08 ".05 " 8.9 " 9 / /5 /0 8 9/00 4. cm.7 cm.7 cm.6 cm Revised 07/3/004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL5

TM e-vision Electronic for Metal Halide s atalog Number IMH-70-D or () 70W Metal Halide ANSI M98, M39, M43 0-77V 50/60Hz Electronic Status: Active DIMENSIONS AND DATA Data Number Watts Volts atalog Number* Line (W) Max (%) Min Wiring Dia igure Weight (lb) Max Distance to (ft) 70 Watt, ANSI ode M98, M39 or M43 Minimum Starting Temp -30 /-0 0 0.67 80 70 IMH-70-D-xxx.0 5 0.9 3 D.6 5 77 0.9 79 (Red) (Blue) (White) (Black) om 0V - 77V igure D (Side exit leads shown see diagram at right for bottom leads with mounting studs detail) (Green) ase must be Grounded Wiring Diagram 3 Tcase max = 85 deg. 7mm. Leads Exit this end. or Bottom Lead & Stud version, solid grommets this end. 35mm. ase Temperature Measurement Location INSTALLATION & APPLIATION NOTES:. Maximum allowable case temperature is 85. See figure above for measurement location. Ignition pulse is 4 kv max 3. All leads are inches long 4. output will shutdown after 0 minutes if lamp fails to ignite 5. must be cycled off then on, after replacing lamp Order Suffix -L -BLS *Ordering Information Description with side exit leads and mounting feet with bottom exit leads and mounting studs Data is based on tests performed by Advance transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. Advance Transformer o. 075 West Higgins Road Rosemont, Illinois 6008-5603 (847) 390-5000 fax: 847-390-509 www.advancetransformer.com A DIVISION O PHILIPS ELETRONIS NORTH AMERIA ORPORATION Revised /3/06 BAL6

Electrical Specifications VEZ-T4-M3-BS Brand Name MARK X line Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 77 requency 60 HZ Status Active Type Num. of s Rated Watts Min. Start Temp ( /) (Watts) MAX % rest * TR3W/GX4Q 3 50/0 0.8 0 0.05 0 0.98.6 0.5 TR4W/GX4Q 4 50/0 0.36 0 0.05 0 0.98.6 0.5 TR57W/GX4Q 57 50/0 0.4 8 0.05 0 0.98.6 0.8 TR70W/GX4Q 70 50/0 0.9 8 0.05 0 0.98.6 0.8 B.E.. Wiring Diagram Enclosure DIMMER BLAK WHITE BALLAST RED RED YELLOW YELLOW LINE DIAG. 3 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Standard Lead Length (inches) Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M) 6.8 " 3.00 ".9 ".00 " 6 7/5 3 9/00 6 cm 7.6 cm 3.3 cm 5. cm Revised 09/0/00 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANE TRANSORMER O. O'HARE INTERNATIONAL ENTER 075 WEST HIGGINS ROAD ROSEMONT, IL 6008 ustomer Support/Technical Service: Phone: 800-37-333 ax: 630-307-307 orporate Offices: Phone: 800-3-086 BAL7