Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Similar documents
Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Multifunction devices

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

SCALE & WEIGHT DISPLAYS

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Time meter electronic

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

Hour Meters / Timers, electronic

Product Information. EIB 700 Series External Interface Box

PRINCIPLES AND APPLICATIONS

Instruction Manual NivuLog 2 Ex / NivuLog 4 / NivuLog PCM Ex

AUTOMATIC VIDEO LOSS A/B SWITCH

HS-509 VIBRATION TRIP MODULE

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

VNS2210 Amplifier & Controller Installation Guide

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

EVENT INPUT/OUTPUT MODULE [PUME]

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

STSW1001T STSW1001R STSW1001 INSTALLATION / USER'S MANUAL

Model TP4-PH Dual Input PH/ORP Display/Controller Operation and Instruction Manual

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

FIELD MOUNTED RATE TOTALISER MODEL 202D

VNS2200 Amplifier & Controller Installation Guide

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Elinchrom Wireless System

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

MS2540 Current Loop Receiver with RS485 Communication

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

MICROPROCESSOR CALCULATION MODULE - S2000

On-screen display signal strength meter Version 1.02

Model IQ4-PC User Manual Revision Date:

Modular Lube Lubrication Systems System Controls

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

DCP100 Digital Control Programmer Specifications

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

SPACESCAN SERIES SS 02

ATVC-4 Plus Amateur Television Repeater Controller Copyright Intuitive Circuits, LLC

Standard signal metering in wall-mounting case

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

What is SnoCam? SnoCam Installation Guide. SolarVu

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

User s Manual Model WF100 Extension Cable for EXA100

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

263 Series LED Bargraph Indicator and Controllers

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

TX2000 Intelligent ph/orp Transmitter

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

Preset counters, electronic

Field Service Procedure Replacement GACP Control Panel Kit, ST24

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

LAUREL ELECTRONICS, INC.

Sensopress LCD Special English

Manuel d utilisation. Série TRA 280

Capacitance Limit Detection nivotester FTC 420/421/422


POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

SingMai Electronics SM06. Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module. User Manual. Revision th December 2016

STD-525T PRECISION TIMER

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Luminaire installation box Surface-mounted box Ceiling installation box

VIDEO GRABBER. DisplayPort. User Manual

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Fibre Optic Modem ODW-622

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Snail Fence InteleCell Deployment Guide

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

SI-510 DUAL TRIP AMPLIFIER

DM1624, DM1612, DM812


ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

Wall-/Pipe-Mount Level Indicator

Filters for Power Lines (Low Leakage Current)

Netzer AqBiSS Electric Encoders

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Process transmitter RMA422

RF4432F27 wireless transceiver module

SAPLING WIRED SYSTEM

Dissolved Oxygen Transmitter

Transcription:

Data Acquisition Networks Installing and Configuring the DM Hardware

What is the DM? D.A.N developed the DM-2 to capture 6 analogue measurements and pulse count in the field. The Average, Maximum and Minimum of each analogue measurement is determined and updated every second The DM stores these measurements temporarily and transmits them wirelessly to the D.A.N. Web-server via the internet at user defined intervals (e.g. once per 2 minutes) The DM can provide local alarm indication or simple control locally as well as transmitting the alarm states to the web-server as soon as they arise. The DM has an on-board power management system that is powered by a power pack or solar panels depending upon the application. The power management system maintains the charge in the 24Vdc lead acid battery which provides the DM with uninterrupted power The DM is in an IP65 enclosure making it suitable for mounting indoors and outdoors, even on buoys in rivers or estuaries.

DM Hardware Summary 6 analogue inputs set individually to ma, V or RTD direct pulse input counter settable to count seconds or pulses Analogue Input has inbuilt totaliser 3 relays which can be associated with any alarm condition 2 alarms per input, counter and totaliser Built in GPRS/GSM or 3G modem 24V lead acid battery to run system Can be charged by mains adapter or solar power Housed in IP65 enclosure with hinged lid

Block Diagram of the DM-2 Power Adaptor or solar cells Alarm Message, Interval Data Instant Data & Settings to Server` Internet Power Supply and charge management 6 Analogue inputs & pulse input.2ah 24Vdc Battery Microprocessor, Memory Power Supply, Relays GPRS, 3G or Satellite Wireless Modem Probes & Transmitters in the field with ma, V or RTD output Loads controlled by Relays

Installing the DM The DM should be installed in the most logical location taking into account the degree of difficulty, the communications, the distance from the probes and access to power (to operate the battery charger) If communications are a bit patchy check the location to ensure that a good signal is present for the mobile communications using a normal GSM or 3G phone as long as it s on the same service as the modem. Occasionally the service provider might not have implemented GPRS in an area even if GSM is present. If in any doubt, speak to the service provider If the signal is generally weak (less than 2 bars on a 5 bar scale) then an external antenna can be fitted. Speak to DAN about ordering this accessory

Installing the DM continued Install the DM using the 4 screw holes on the outside 4 corners of the box. Do not drill fixing holes through the inside of the box anywhere inside the gasket protected area Bring cables into the DM via cable glands preferably mounted in the underside of the box body. Make sure that the cable glands tighten down onto the cable to form a good airtight seal. If not then use PVC tape on the cable to increase its diameter where it passes through the cable gland Since the signal lines are all low voltage and low current, the cables do not need to be heavy duty..5mm 2 multi-strand would be more than adequate. It is always good practice to use cables with an overall shield

DM Analogue Input Features 6 Inputs accept ma, V and RTD direct All common industrial milliamp and voltage ranges accepted RTD standard range is -25 to +25 o C If spare, input 5 can be connected to the on-board battery voltage monitoring terminal

DM Digital Input Can count external pulses or seconds Count up to 4kHz without missing pulses Two set-points on total for batching quantities or measuring elapsed time Two counters Resetable current counter in RAM Non resetable gross counter in non volatile EEPROM Resetable counter s value transfers to gross counter on reset Reset can be configured to occur from any alarm condition or via web-server command Resetable counter can reset itself and thus transfer its total to the accumulating gross counter every time the set point is reached External pulses Input conditioning Software selects source Resettable Current counter Count = set point pulse per sec Alarm Manager handles alarm functions on total and reset of counter On reset current count adds to gross count Gross counter in non volatile memory reset

DM Totaliser Input Totalises input if selected Reads A-D value of input and adds it to the binary counter once per second Will totalise for 47 days at maximum flow rate before counter overflows. 2 set-points for batching as per standard configuration. Website calculate the actual flow from the start and end values of the counter each reporting period taking into account calibration values recorded on the website A-D Now Each second totalise A-D Now Values In 4 byte binary counter Count = setpoint reset read per sec Alarm Manager handles alarm functions on total and reset of counter

Local DM Alarms 2 alarms per analogue input allow local control 2 alarms on counter/timer allow local control 2 alarms on totaliser allow local control Any of these 6 alarms can be configured to act on any of the relays R, R2, R3 Any of the Alarm conditions can also be configured to reset the digital counter/ timer and the analogue totaliser R R2 R3 Resettable Counter Software reset Resettable Totalizer Software Reset

Alarm Messages by SMS and Email These messages are NOT generated by the DM units but by the web server. The alarm set points and all other parameters are downloaded and synchronised to the DM by the web server automatically during any communication between them. SMS messages are sent via Redcoal, a company that DAN has contracted to provide our clients with SMS to anywhere in the world at a rate of approximately 2c per SMS (+GST if applicable) 5 phone numbers can be entered into the system The DAN web server sends emails free to any of 5 email addresses including web-enabled mobile phones

The GSM or 3G Modems The DM main board has a serial communications plug that connects to a GSM or 3G modem. The Modem is in packet mode only while it is transmitting and receiving data from the web server. At the time of each transmission, the web server will let the DM know if there are any settings that have changed. The new settings are then downloaded to the DM before the communications socket closes again. When communications are complete, the modem closes the socket and switches back to GSM mode.

GSM and 3G Modems (cont.) The modem can then be dialled. The DM recognises the incoming ring, stores the emanating caller number and counts the number of rings. If it counts 2, 3 4 or 5 rings it will grab the latest measurements and send them as instantaneous data to the web server together with the caller id. The web-server checks the caller id and if it is registered against that DM serial number, it will send the instantaneous data to that caller id via SMS. Note that even if there is no SMS service implemented, the data still is present on the web server and can be viewed using Data Search.

Power Supply The DM has two sealed 2V lead acid batteries which would run it for between 24 and 6 hours depending upon usage if there was no recharging. An isolated charging circuit is included on the main board that can be powered from solar panels or a mains adapter, ( 5 VDC). As standard a unit without solar power is provided with a 2V plug pack that is connected to any one of the 3 charging input power pairs. )Select one + terminal and one terminal. Make sure the polarity is correct or there will be no chrging As noted earlier battery voltage can be monitored if there is a spare input.

DM Construction Enclosure is suitable for outdoors and is IP65 rated It has a hinged lid. The electronics circuit is mounted in the lid for easy access to the terminals. The modem clips into a bracket mounted on the gear-plate. The batteries sit in a recess under a plastic cover Space for cable glands to bring in cables through the bottom of the enclosure

DM Main Board Connections Relay 2 N.O Relay 3 N.O Power from solar panels or charger Charger Switch - - - + + + On No connection Off 7 DM-2 Logger on/off 2 6 5 4 3 Off On + - + - Relay N.O 24V Battery Battery monitor Modem Power

Switch Settings for DM Analogue Inputs x -25 to +25oC X - to +V X -4V X ph/orp/-2 to +2V X 5V/-5V/-V X -2mA/4-2mA 4 3 2 8 7 6 5 4 3 2 Signal Pt RTD ma, V

DM Terminals Designation This diagram provides a good overall view of the input and output terminals of the DM

Setting Up the Inputs to the DM Set the switches on the daughter board to the correct settings. Then connect up the inputs as appropriate

Terminal Connections for DM Pulse Inputs Terminal numbers 2 3 4 5 6 Type of Input +24Vdc +5Vdc Input GND GND GND 24V Sold State Sensor + Output V Contact closure A B Voltage Pulse A B

Terminal Connections for DM Analogue Inputs Terminal numbers 2 3 4 5 6 Type of Input +24Vdc +5Vdc -5Vdc +In GND RTD Two wire tx + of TX - of TX Current or voltage source +In V RTD 2 wire A B Link to 5 RTD 3 Wire A B B Sense External DAN Amplifier +V -V Signal V

DM Analogue Input Connections DAN Amplifier +24V +5V -5V Input GND DAN Amplifiers use some or all of the +24V, +5V, -5V, +In and V Cntct Closure +24V Input Connect a 3k9 resistor between +24V and +In and set to current input for contact closure detection + - 2 Wire Tx +24V Input Connect a 2 wire tx between +24V and +In and set input for current +24 +5V -5V +In V RTD

DM Analogue Input Connections 2 Connect a voltage or current source between +In and V Input GND Connect an RTD between +In and V and link RTD and V Input GND RTD Connect an RTD between +In and V and the lead length compensation wire to RTD Input GND RTD +24 +5V -5V +In V RTD V or I Source RTD 2 Wire RTD 3 Wire

Connecting a Two Wire Transmitter to a DM Typical Two Wire Transmitter +24Vdc Pt 4-2mA Input +24V In 2 ohms Internal resistor Standard Temperature Input to DM Channels to 6

Connecting a Sourced Current Transmitter to a DM Typical Sourced Output from Transmitter 4-2mA output In GND 2 ohms Internal resistor Standard Input to DM Channels to 6

Connecting a Sourced Voltage Transmitter to a DM Typical Sourced Output from Transmitter In Input impedance approx Megaohm -V output GND Standard Input to DM Channels to 6

Connecting a 3 Wire RTD to a DM Turn on each channel of the 4 way DIP switch for that channel. Turn off all of the 8 way DIP switches -5 to 2 o C In Pt RTD Return GND RTD Cable Res Sense Standard Input to DM Channels to 6

Connecting a 2 Wire RTD to a DM -5 to 2 o C In Pt RTD Return GND RTD Standard Input to DM Channels to 6

+ 4-2mA, 2 port isolated signal transmitter, 24Vdc output loop powered 4-2mA ph or ORP Loop + Retransmit isolated 4-2mA ph or ORP signal + + + + +24Vd c Analog in + Analog in - V dc +24Vd c +5V -5V Input PLC non isolated Analog input DM Input channel GND Isolating the DM from the PLC Using a Two Wire Loop Powered Isolator RTD

+ +24Vd c Vdc 4-2mA, 3 port isolated signal transmitter, 24Vdc powered 4-2mA PLC Input Loop + Retransmit isolated 4-2mA to DM + + +24Vd c Analog in + Analog in - Vd c +24Vdc +5V -5V Input GND PLC non isolated Analog input DM Input channel Isolating the DM from the PLC Using a 3 Port Isolated Transmitter RTD

Example of Using DM to Control Acid Dosing and Log Data Power to transmitter provided by signal loop If dosing pump just needs contact closure to operate Loop Powered ph transmitter +24V One of six DM Inputs set to 4-2mA +Input DM Switched contact of your choice of the relays R or R2 or R3 Dosing Pump On/Off Control of Acid Dosing Pump via Relay on DM ph Probe

Example of Using DM to Control Acid Dosing and Log Data Power to transmitter provided by signal loop Loop Powered ph transmitter ph Probe +24V One of six DM Inputs set to 4-2mA +Input If dosing pump just needs 24V applied to operate DM Switched contact of your choice of the relays R or R2 or R3 +24V V V 24Vdc Supply Dosing Pump +24V On/Off Control of Acid Dosing Pump via Relay on DM

Normally Energised & De-energised Relay Operation We define the Normal State of an alarm relay as the state it is in when there is no alarm trip condition Thus a Normally Energised Relay is one which has its coil energised when there is no alarm condition. The coil will become de-energised when an alarm condition occurs. Also called Fail Safe mode because the alarm condition and power failure result in the same relay state A Normally De-energised Relay is one which has its coil de-energised when there is no alarm condition. The coil will become energised when an alarm condition occurs. If power fails the relay remains de-energised Normally Energised Normally Deenergised Alarm reset N.O. Coil on N.O. Coil off Alarm tripped N.O. Coil off N.O. Coil on

Alarms Signal High Alarm Setpoint Signal Dead band Low Alarm Reset point Reset point Setpoint time time Alarm reset Alarm tripped Alarm reset Alarm reset Alarm tripped Alarm reset When the signal is greater than or equal to the setpoint then a presently reset alarm will trip. Once the alarm is tripped it will remain so until the signal decreases to the reset point When the signal is less than or equal to the setpoint then a presently reset alarm will trip. Once the alarm is tripped it will remain so until the signal increases to the reset point

Next Step: See the Presentation How to Configure the DM *