CABLE LOSS MASKING EFFECT

Similar documents
By Jim Norton Bird Technologies Group Applications Engineer

JD725A Cable and Antenna Analyzer - Dual Port

Product Introduction. Duplexer Box MN2555A. Signal Analyzer MS2830A. Ver.1.0

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Lab Wireless Mathematics

Sidelighter TM Optical distance to fault measurement module

User Manual. LPA_Tool. Prepared by: Customer Support. Date: November 25, 1999 WaveRider Document N o.: LPA_Tool User Manual_V2-0.

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

db math Training materials for wireless trainers

Chapter 6 Tuners. How is a tuner build: In it's most simple form we have an inductor and a capacitor. One in shunt and one in series.

IF and L-Band Fiber Optic Links. Performance Highlights

PiMPro Rack Mount Analyzer

SPINNER BROADCAST EXPLANATION OF THE MULTI CHANNEL COMBINER SPECIFICATIONS

Academia Sinica, Institute of Astronomy & Astrophysics Hilo Operations

SAGE Instruments UCTT 8901 Release Notes

UF7500/UF17500/UF25000 Series UHF Band Pass Filters

The following pages list UK UHF DTT transmitters. These are arranged by region and then grouped into main stations with the relays in alphabetical

RF Characterization Report

PiMPro Portable Analyzer PiMPro Classic 1821

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

100G SR4 TxVEC Review Comment r01-43

Practical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011

FCC ID: IMK-ILCISA EMI TEST REPORT

X-Band Redundant LNB Systems

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

TABLE of CONTENTS. Item Description Page. 2.0 Simplified System Block Diagram 2

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

5100 Series IF Fiber Optic Links

RF (Wireless) Fundamentals 1- Day Seminar

ENGINEERING COMMITTEE

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

As shown below and on the following page, a wide variety of Azimuth patterns can be selected or customized for TRASAR antennas.

The Definition of 'db' and 'dbm'

TTA, Receiver Multicouplers & Preselectors. You re heard, loud and clear.

N5264A. New. PNA-X Measurement Receiver. Jim Puri Applications Specialist March Rev. Jan Page 1

CYL-X7CAP-1 Small Cell Cantenna X-Pol, / MHz, 1FT

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

Calibrating the timecode signal input

Network Analyzer Terminal - Scalar Network Analyzer

2W SDARS ECHO Repeater

XCOM1002JE (8602JE) Optical Receiver Manual

OTX Optical Transmitter. Operation Instructions

Ku-Band Redundant LNB Systems

Implications and Optimization of Coverage and Payload for ATSC 3.0

30 GHz Attenuator Performance and De-Embedment

OTD-3000-DC FREQUENCY AGILE TELEVISION DEMODULATOR. PAL-D (China) STANDARD INSTRUCTION MANUAL

Compact EGC Fiber Deep Nodes A90100 and A90300

High-definition services are included on both mux BBC B and the temporary HD Muxes.

Redundant LNB Systems

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

OTM-3000-I FREQUENCY AGILE TELEVISION MODULATOR PAL I STANDARD INSTRUCTION MANUAL

OTR-3550 FREQUENCY AGILE - F.C.C. COMPATIBLE TELEVISION PROCESSOR INSTRUCTION MANUAL

OTD-3000 FREQUENCY AGILE TELEVISION DEMODULATOR INSTRUCTION MANUAL

DANGER WARNING CAUTION

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Redundant LNB Systems

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.

Tests on 3G-Base Stations to TS with FSIQ and SMIQ

RF Level Test System +20 dbm to 130 dbm

OTM-3000-HR FREQUENCY AGILE - HIGH RESOLUTION TELEVISION MODULATOR INSTRUCTION MANUAL

RF4432F27 wireless transceiver module

INSTRUCTION MANUAL ALP690. Active LPDA Antenna. Fill in for your records: Serial Number: Purchase Date: Rio Rancho, NM, USA

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

What is the minimum sound pressure level iphone or ipad can measure? What is the maximum sound pressure level iphone or ipad can measure?

High Power Bundle for the Icom IC-7300

Configuration Vestas VMP3500

High Performance Coaxial Jumpers The Link for a better Network Quality SITE SOLUTIONS

Measurement of Television Channel Levels on CATV Networks

C-Band Redundant LNB Systems

40G SWDM4 MSA Technical Specifications Optical Specifications

MEVA/TMG/32 IP/03 04/05/17 Thirty second MEVA Technical Management Group Meeting (MEVA/TMG/32) Havana, Cuba, 10 to 12 May 2017

MILLIMETER WAVE VNA MODULE BROCHURE

Redundant LNB Systems

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

40G SWDM4 MSA Technical Specifications Optical Specifications

Prisma Optical Networks Ancillary Modules

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Calibrating attenuators using the 9640A RF Reference

4x50 User s guide Modbus TCP

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

PM Series Microwave Power Calibration System

2J7041BGa CELLULAR/LTE MIMO and GNSS

USB-TG124A Tracking Generator User Manual

RF Characterization Report

PM Series Microwave Power Calibration System

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Spectrum Analyzers. 2399A 9 khz to 3 GHz Spectrum Analyzer.

Using Surplus 23 GHz Modules At MHz By Al Ward W5LUA

FRQM-2 Frequency Counter & RF Multimeter

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

L-Band Fiber Optic Links

R&S FPC Spectrum Analyzer Unexpected performance in entry class

R-1550A Tempest Wide Range Receiver

DC-100 DTV CAM Series

Transcription:

CABLE LOSS MASKING EFFECT Masking Effect of Cable Loss on VSWR and Return Loss Measurements Jim Norton, Applications Engineer Bird Technologies Group Tel: 866.695.4569 / 592-APP-0905 613-APP-0905 Application Note

By: Jim Norton, Applications Engineer Bird Electronic Corporation Introduction The masking effect of cable loss may cause your antenna to "appear" to perform more efficiently than is actually the case. In fact, it is possible to measure apparently acceptable VSWR or return loss levels even though your antenna may be completely out of operation. The purpose of this article is to provide an understanding of cable loss masking effect and explain how to avoid these pitfalls. Figure 1 and Examples 1 & 2 illustrate the masking effects of cable loss. As you can see, 3 db of cable loss will produce measurements with a significant error offset. Given that a typical antenna is designed to operate at 1.5 VSWR (-14.0 db return loss) or better, this could make the difference between judging your antenna as in or out of specification. Furthermore, 7 db of cable loss could render the measurement meaningless. This worst-case scenario may allow an antenna failure to go undetected! A step-by-step procedure to arrive at these figures is discussed later in this paper. For your convenience, the "Cable Loss Masking Effect Chart" may be found in the appendix of this application note. You can also readily perform this analysis and several others for your specific application by downloading a complimentary copy of the "RF Calculator" at (under "Support" and "Technical Application Notes" tabs). Figure 1: Cable Loss Masking Effect Cable loss will mask antenna VSWR or or Return Loss () measurements taken taken at the at the transmitter end end of of the the cable. cable. VSWR VSWR or or measured at antenna measured at antenna at = at at Tx - (2 x CL) = at Tx (2 x CL) Cable Loss Cable (CL) Loss (CL) Transmitter Transmitter (Tx) (Tx) VSWR or measured VSWR at or Tx measured at Tx Example 1: Cable Loss of 3 db Example 2: Cable Loss of 7 db Cable loss: 3.0 db Cable loss: 7.0 db VSWR measured at transmitter: 1.50 VSWR (-14.0 db return loss) VSWR (actual): 2.33 VSWR (-8.0 db return loss) VSWR measurement error: 0.83 VSWR (6.0 db return loss) VSWR measured at transmitter: 1.50 VSWR (-14.0 db return loss) VSWR (actual): 100+ VSWR (0.0 db return loss) VSWR measurement error: 98.5+ VSWR (14.0 db return loss) Forward power measured at transmitter: 100.0 W Forward power at the antenna (actual): 50.1 W Forward power measurement error: 99.6 % W Forward power measured at transmitter: 100.0 W Forward power at the antenna (actual): 20.0 W Forward power measurement error: 400.0 % W Reflected power measured at transmitter: 4.0 W Reflected power at antenna (actual): 8.0 W Reflected power measurement error: -50.0 % W Reflected power measured at transmitter: 4.0 W Reflected power at antenna (actual): 20.0 W Reflected power measurement error: -80 % W Jim Norton pg. 2

Masking Effect The masking effect of cable loss causes an error offset when measuring antenna VSWR or return loss levels. This error offset may be corrected with the following equation: at = at Transmitter - (2 x CL) = Return Loss CL = Cable Loss VSWR levels may be corrected by converting to/from equivalent return loss levels. Cable Loss Cable loss is the total insertion loss of your transmission cable system. This will typically include insertion loss of the transmission cable, jumper cables, connectors and lightning protection. Note, loss of other components (e.g. VSWR/power monitor, duplexer, combiner or filter) may also come into play. As an example, the transmission cable system for an 800 MHz antenna mounted at the 200 ft (61 m) level of a tower may include the following: Transmission Cable: 7/8" Andrew LDF5-50A, 1.13 db/100 ft (3.69 db/ 100 m) @ 824 MHz Jumper Cable: 1/2" Andrew FSJ4-50B, 3.23 db/100 ft (10.6 db/ 100 m) @ 824 MHz 230 ft (70 m) of transmission cable = 2.60 db 20 ft (6 m) jumper at transmitter = 0.65 db 10 ft (3 m) jumper at antenna = 0.32 db Connection pairs x 4 = 0.1 x 4 = 0.4 db Lightning protection = 0.1 db Cable loss (total insertion loss) = 4.07 db In this case, a 1.17 VSWR (-22.1 db ) measured at the transmitter end of the cable would indicate that the antenna measurement is actually 1.50 VSWR (-14.0 db ). This would be acceptable as a typical antenna is designed to operate at 1.50 VSWR (-14.0 db ) or better. Similarly, a 1.50 VSWR (-14.0 db ) measured at the transmitter would equate to a 3.09 VSWR (-5.8 db ) at the antenna. This would signify that the antenna in not performing to the 1.50 VSWR (-14.0 db ) specification. Finally, a 2.29 VSWR (-8.1 db ) at the transmitter yields an antenna with a 100+ VSWR (0.0 db ). This measurement should alert the user that the antenna has failed and requires immediate attention! Measuring Cable Loss Cable loss can be measured with the same equipment used to measure your antenna VSWR or return loss levels. A vector network analyzer (VNA) with a cable loss mode streamlines this measurement. Simply connect one end of your cable to the VNA, place an open or short at the far end of the cable, and perform the cable loss test. A VNA with a distance-to-fault (DTF) or fault location mode will automatically correct for cable loss. The cable loss per meter or foot parameter is entered during the setup of the DTF measurement. Once setup, connect one end of your cable to the VNA with the antenna connected at the far end of the cable and perform the DTF test. The result is an antenna VSWR or return loss measurement corrected for cable loss. A power meter may also be used to calculate cable loss. Measure the power levels at the input and output of your cable, convert to units of dbm, and calculate the difference. As an example, input power of 100 W (50 dbm) and output of 50 W (47 dbm) yields a cable loss of 3 db (50 dbm - 47 dbm). Cable loss may also be estimated as we did in the previous section of this paper. Sum the insertion loss parameters for each component of your transmission cable system at your operating frequency. Note, insertion loss increases as frequency increases. Step-by-Step Procedure To review, cable loss has a masking effect on antenna VSWR and return loss measurements. The end result is an error offset that must be corrected. The following exercise walks you through this process with a step-by-step procedure. Referring to Figure 1 and Example 1 at the introduction of this paper, a 100 W transmitter is connected to a cable and antenna. Cable insertion loss is known to be 3 db. Measurements taken at the transmitter end of the cable indicate a VSWR of 1.5 (- 14.0 db return loss). What is the actual antenna VSWR or return loss? Step 1) Forward Power at We will begin by calculating the forward power present at the antenna. 1a) List Known Values Forward Power at Transmitter = 100.0 W Cable Loss = 3.0 db Jim Norton pg. 3

1b) Forward Power Forward Power at Transmitter = 100.0 W Convert W to dbm = 10 x Log 100.0 W + 30 = 50.0 dbm Forward Power at = Forward Power at Transmitter - Cable Loss = 50.0 dbm - 3.0 db = 47.0 dbm Convert dbm to W (47.0 dbm - 30) / 10 = 10 = 50.1 W Step 2) Reflected Power at 2a) List Known Values Measurement at transmitter = 1.50 VSWR = -14.0 db Return Loss Forward Power at Transmitter = 100.0 W = 50.0 dbm Cable Loss = 3.0 db 2b) Reflected Power Reflected Power at Transmitter = Forward Power x 10 = 100.0 W x 10 (-14 db / 10) = 4.0 W Convert W to dbm = 10 x Log 4.0 W + 30 = 36.0 dbm (Return Loss / 10) Reflected Power at = Reflected Power at Transmitter + Cable Loss = 36.0 dbm + 3.0 db = 39.0 dbm Convert dbm to W (39.0 dbm - 30) / 10 = 10 Step 3) VSWR and at 3a) List Known Values Forward Power at = 50.1 W = 47.0 dbm 3b) VSWR and at Rho at = Sqrt (Reflected / Forward Power) = Sqrt (8.0 W / 50.1 W) = 0.4 VSWR at = (1 + Rho) / (1 - Rho) = (1 + 0.4) / (1-0.4) = 2.33 Return Loss at = 10 Log (Reflected / Forward Power) = 10 Log (8.0 W / 50.1 W) = -8.0 db Summary As expected, the results of this step-by-step procedure agree with those listed in Example 1 at the beginning of this article. The "Cable Loss Masking Effect Chart" (see appendix) and "RF Calculator" () will confirm as well. After performing a number of calculations or reviewing the chart you will see a few trends that are worthy of note: 1) As cable loss increases the error offsets increase as well. 2) As VSWR or return loss levels increase the error offsets also increase. 3) Error offsets are independent of power levels. As an example, 3 mw, 50 W and 1 kw applications are all equally affected by the masking effect of cable loss. In conclusion, cable loss causes a masking effect when measuring antenna VSWR and return loss levels. Cable loss can be measured with the same vector network analyzer or power meter used for your antenna measurements. Correcting for this error offset is essential to determine your antenna's actual performance level. Appendix See the following attachment: Cable Loss Masking Effect Chart Reflected Power at = 39.0 dbm Jim Norton pg. 4

Chart Cable insertion loss (CL) will mask antenna VSWR or Return Loss () Measurements taken at the Transmitter (Tx) end of the cable. Specifically, at = at Transmitter (2 x CL). Example: If the cable loss is 3.0 db, a VSWR of 1.50 (-14.0 db ) Measured at the transmitter end of the cable yields an antenna VSWR of 2.33 (-8.0 db ). Note, CL may include insertion loss from cables, connectors, lightning protectors, duplexers, combiners, etc. CL VSWR at: (db) at: CL VSWR at: (db) at: (db) Tx Ant Tx Ant (db) Tx Ant Tx Ant 0.5 1.05 1.06-32.3-31.3 0.5 1.60 1.70-12.7-11.7 1.0 1.05 1.06-32.3-30.3 1.0 1.60 1.82-12.7-10.7 2.0 1.05 1.08-32.3-28.3 2.0 1.60 2.15-12.7-8.7 3.0 1.05 1.10-32.3-26.3 3.0 1.60 2.71-12.7-6.7 5.0 1.05 1.17-32.3-22.3 5.0 1.60 6.40-12.7-2.7 7.0 1.05 1.28-32.3-18.3 7.0 1.60 100+ -12.7 0.0 9.0 1.05 1.48-32.3-14.3 9.0 1.60 100+ -12.7 0.0 0.5 1.10 1.11-26.4-25.4 0.5 1.70 1.82-11.7-10.7 1.0 1.10 1.13-26.4-24.4 1.0 1.70 1.97-11.7-9.7 2.0 1.10 1.16-26.4-22.4 2.0 1.70 2.39-11.7-7.7 3.0 1.10 1.21-26.4-20.4 3.0 1.70 3.14-11.7-5.7 5.0 1.10 1.35-26.4-16.4 5.0 1.70 10.10-11.7-1.7 7.0 1.10 1.63-26.4-12.4 7.0 1.70 100+ -11.7 0.0 9.0 1.10 2.22-26.4-8.4 9.0 1.70 100+ -11.7 0.0 0.5 1.20 1.23-20.8-19.8 0.5 1.80 1.94-10.9-9.9 1.0 1.20 1.26-20.8-18.8 1.0 1.80 2.12-10.9-8.9 2.0 1.20 1.34-20.8-16.8 2.0 1.80 2.66-10.9-6.9 3.0 1.20 1.44-20.8-14.8 3.0 1.80 3.65-10.9-4.9 5.0 1.20 1.81-20.8-10.8 5.0 1.80 19.73-10.9-0.9 7.0 1.20 2.67-20.8-6.8 7.0 1.80 100+ -10.9 0.0 9.0 1.20 6.20-20.8-2.8 9.0 1.80 100+ -10.9 0.0 0.5 1.30 1.34-17.7-16.7 0.5 1.90 2.07-10.2-9.2 1.0 1.30 1.39-17.7-15.7 1.0 1.90 2.28-10.2-8.2 2.0 1.30 1.52-17.7-13.7 2.0 1.90 2.94-10.2-6.2 3.0 1.30 1.70-17.7-11.7 3.0 1.90 4.25-10.2-4.2 5.0 1.30 2.40-17.7-7.7 5.0 1.90 100+ -10.2-0.2 7.0 1.30 4.78-17.7-3.7 7.0 1.90 100+ -10.2 0.0 9.0 1.30 100+ -17.7 0.0 9.0 1.90 100+ -10.2 0.0 0.5 1.40 1.46-15.6-14.6 0.5 2.00 2.19-9.5-8.5 1.0 1.40 1.53-15.6-13.6 1.0 2.00 2.45-9.5-7.5 2.0 1.40 1.72-15.6-11.6 2.0 2.00 3.24-9.5-5.5 3.0 1.40 2.00-15.6-9.6 3.0 2.00 4.97-9.5-3.5 5.0 1.40 3.23-15.6-5.6 5.0 2.00 100+ -9.5 0.0 7.0 1.40 11.14-15.6-1.6 7.0 2.00 100+ -9.5 0.0 9.0 1.40 100+ -15.6 0.0 9.0 2.00 100+ -9.5 0.0 0.5 1.50 1.58-14.0-13.0 0.5 2.50 2.85-7.4-6.4 1.0 1.50 1.67-14.0-12.0 1.0 2.50 3.34-7.4-5.4 2.0 1.50 1.93-14.0-10.0 2.0 2.50 5.24-7.4-3.4 3.0 1.50 2.33-14.0-8.0 3.0 2.50 12.80-7.4-1.4 5.0 1.50 4.44-14.0-4.0 5.0 2.50 100+ -7.4 0.0 7.0 1.50 100+ -14.0 0.0 7.0 2.50 100+ -7.4 0.0 9.0 1.50 100+ -14.0 0.0 9.0 2.50 100+ -7.4 0.0 Jim Norton pg. 5