Philips StressVue Tango M2 Interface Notes

Similar documents
Burdick Quest Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Schiller AT-10 plus Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

GWL/ Power Group Technology Solutions Stay Powered for the Future

Honeywell HomMed Wireless Scale Quick Reference Guide

June/July 2016 Med Tips

RF Solution for LED Display Screen

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Camera Setup Instructions

Quick Start Guide Building and Scheduling a Show

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

Data Acquisition Instructions

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

2 Connect your video source

SXGA096 DESIGN REFERENCE BOARD

1 Synchronising Xsens with the Delsys Trigno EMG System

Med Tips. PRODUCT INFORMATION FreeStyle Battery Warranty. Q: What is the warranty for my FreeStyle Battery?

22" Touchscreen LED Monitor USER'S GUIDE

2 Connect your video source

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

EEG A1452 SCTE-104 Inserter Frame Card

Interface sheet - Edan ST-1212 Stress - CPET ergometer

RADIO FREQUENCY SYSTEMS

Integration of the Zetasizer µv and OmniFACE into an SEC system

Wall Ball Setup / Calibration

Electrocardiogram (ECG) Version Date: 2017-FEB-15 Document Effective Date: 2017-MAY-15

Modbus for SKF IMx and Analyst

Using LightSpace CMS for User Created Calibration LUTs

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

IMPORTANT! This instruction guide explains how to install your CCTV system.

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Interface sheet - Nihon Kohden 1550K - CPET Treadmill

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

Setting up your Roland V-Drums with Melodics.

Setup Guide. Panasonic VX200/VX300/BT300. Plasma Displays. Rev. 1.1

R Series Quick Reference Guide

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

Calibrating and Profiling Your Monitor

PXL2470MW LED LCD Monitor

PXL2760MW LED LCD Monitor

2 Connect your video source

Weschler AMT Software for the Enhanced Version Transformer Advantage

Multi RF Deck / Multi Control Head

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Operating Instructions

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Amino. Digital Television. Sun City & Hilton Head Island

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

Audio Design Associates (ADA)

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

Cablecast Server. Setup Guide. c Tightrope Media Systems For Cablecast version Build 74

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

WQ Series Water Quality Bench top Meters

Installation Note. Agilent 89441A Option AYC Installation Kit

PLL2210MW LED Monitor

PLL1920M LED LCD Monitor

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

YAMAHA 03D SERIAL AUDIO MIXER

Setup Guide. Klein K-10CP Colorimeter. Rev. 1.1

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PL2410W LCD Monitor USER'S GUIDE.

VNS2200 Amplifier & Controller Installation Guide

Video Server SED-2100R/S. Quick Installation Guide

P-2 Installing the monitor (continued) Carry out as necessary

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

TeamWork Kits Installation Guide

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

SmartCrystal Cinema Neo

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

COLOR TFT LCD MONITOR. Manual

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Activity P32: Variation of Light Intensity (Light Sensor)

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

NS-3 RF Noise Source Operation Manual

Quick Setup 1 Unpack the projector

PRECAUTIONS CONTENTS: Please follow these precautions:

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

Professional Media Server Quick Start Guide

V 2.0 RD-8. Setup Guide. Revised:

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Instructions for Use: Video Inspection Scope with Display

Transcription:

Philips StressVue Tango M2 Interface Notes To setup Tango M2 with the StressVue stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with the StressVue. This cable enables the StressVue to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the StressVue display and reports. o SunTech Part Number = 91-0013-01 o Connection Ends: StressVue Connection 9 pin female Tango M2 Connection 9 pin female ECG Trigger Cable provides the ECG signal from the StressVue to the Tango M2. o SunTech Part Number = 91-0011-01 o Connection Ends: StressVue Connection BNC male Tango M2 Connection BNC male Philips StressVue (2 nd Gen), Tango M2 Interface Notes Page 1 of 5

Tango M2 Monitor RS-232 Connection Part # 91-0013-01 ECG Trigger Connection Part # 91-0011-01 USB Interface MODULE ECG Trigger TTL 2. Connect the RS-232 Cable From: the RS-232 connection on the rear panel of the Tango M2. To: the COM 2 port on the back of the StressVue. If a second serial port is not available, a PC board to provide this 2 nd serial port may be required (contact Philips for details). Philips StressVue (2 nd Gen), Tango M2 Interface Notes Page 2 of 5

3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the TTL output connection on the back of the Philip USB Interface Module. 4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. d. Using the UP or DOWN arrows, scroll through the list until StressVue is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. StressVue System Setup a. Select Settings. b. Click on the Exercise tab. c. Click NIBP. d. Choose SUNTECH TANGO M2. e. Click on Save Profile. f. Click Yes. g. Click on Exit. During the test, click on the BP button or press F3 to prompt a BP. Please note that the first measurement taken by the Tango M2 during the test does not automatically transfer to the stress system software. All subsequent measurements will transfer as expected. FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. Philips StressVue (2 nd Gen), Tango M2 Interface Notes Page 3 of 5

c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. 2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). Philips StressVue (2 nd Gen), Tango M2 Interface Notes Page 4 of 5

3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com Philips StressVue (2 nd Gen), Tango M2 Interface Notes Page 5 of 5