training T R A I N I N G W O R K S U R FA C E A N D S U P P O RT B A S I C S T R A I N I N G TA B L E B A S I C S...9 2

Similar documents
panels PA N E L O V E RV I E W S U P E R PA N E L B A S I C S M O D U L A R P OW E R PA N E L B A S I C S...3 9

livello application guides

height-adjustable bench price & application guide

credenzas preconfigured

Non- Metal Front Finish (if applicable) Case & Metal Front Finish. Pull Style. A Full Pull B Rectangular Handle Pull D District Handle Pull.

credenzas preconfigured

Case & Metal Front Finish. Pull Style. Non- Metal Front Finish (if applicable) A Full Pull B Rectangular Handle Pull D District. Seamless.

YTH Navigate Height-Adjustable Gable Leg Complete Table

The most adaptable console solution for control rooms and critical operation environments

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Check what you have received against the component checklist and hardware above.

Element Finish. Fabric PE E PANEL MATRIX PANEL MATRIX PANEL MATRIX

product map fascias 12mm Glass Assembly Hardware Kit Electrical Side Panel

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

Synthesis Tables Price List. April 10, 2006 Updated October 24,

Emerald Cubicle System

ControlTrac PRODUCT GUIDE tbcconsoles.com

CHEMISTRY. Price List 2018

MY-HITE ADJUSTABLE TABLE

Cable System Installation Guide

TV Lift System Model CL-65 Installation Instructions

SECTION 9 CABLE MANAGEMENT CABLE MANAGEMENT. CABLE MANAGEMENT Cable Ducts.

The Two Assemblies. Standard Assembly For signs up to 11" wide. Pull flexible lens directly outward with Sucton Cup Tool for lens removal

Check what you have received against the component checklist and hardware above.

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at

velocity standard 08 velocity features and benefits: dimensions:

RACKS, ENCLOSURES AND CABLE MANAGEMENT

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

RIPPLE TANK - projection, with strobe & kit

INSTALLATION INSTRUCTIONS

Embrace 2.5 Backlit Push-Fit Tension Fabric Display

New Products. New Possibilities.

TECHNICAL INFORMATION

Cellular Signal Booster

May 2017 Specification Guide

120 V~ Feed-Through DIN Panels (and Accessories)

The Tego Ceiling System

3M Distribution Box (DDB)

Lyndhurst Secondary Technology Package Addendum # Bid Date: Wednesday, August 30, 1:00PM. Items issued in this addendum:

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Digital StoreFront JDF with non-efi JDF-Enabled Devices

velocity standard 07 velocity features and benefits: dimensions: additional information:

lumber-core Mahogany Walnut Cherry Medium Oak

INSTALATION PROCEDURE

HCS - HES Cabling Systems

In-Wall Control Mount for ipod Touch

1.0 DESCRIPTION. This specification covers roll-up signs to be used in temporary traffic control zones.

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Fiberglass - Technical Data

Power & Cable Routing for Tables Technology. Within reach.

System Satellites Acoustimass Module. 2.5" (64 mm) full-range driver (per satellite) 5.25" (133 mm) dual voice coil low frequency driver

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

IndyGo Facility Upgrades Project 35671EE

MODULAR RAILROAD SPECIFICATIONS FAQ

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

Order #XXXXX - ECO x10 Inline Display. Setups. 10 Plan View

INSTALLATION INSTRUCTIONS FOR

TITLE: FIBER OPTIC SHOCK FIXTURES

RT AUDIO RETRACTABLE CABLE

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

Coyote popup display set up instructions

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

BRIGHT BRIGHTER BRIGHTEST ONE ILLUMINATOR DESIGN THREE LIGHT SOURCES. featuring the EvenVue Reflector System


Adapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication

HANNAY REELS. Audio/Video Reels. For use in: Production & Recording Facilities Television & Radio Stations

Series 2500 Vibration Isolation Table

Cabling and Completing Assembly of the Cisco TelePresence System 1000

Con o t n e t n e t n s t

READ ME FIRST. Touchstone TV Lift

Open Frame Racks and Accessories

Tone. Price List October Knoll, Inc. P.O. Box Water Street East Greenville, PA knoll.com

HQ Electromagnetic Channel Locks

Structured Cabling Introduction & Installation Guide

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

RT USB RETRACTABLE CABLE

Price List August 2017

GENUINE PARTS ! CAUTION

CRINION OPEN TABLE Price List July 2012

Modulate Magnetic Kit 10-01

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

LUMIÈRE CONFIGURATION - D LUMIÈRE LIGHT WALL PRODUCT CODE: LLW20D

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Screen ONE XL and Screen Classic

INSTALLATION GUIDE

Power Injector 1520 Series

Instruction manual. KUZMA 4POINT 14 inch TONEARM Serial Number:

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Table of Contents. Crinion Open Table

Sliding Door System Bohle SlideTec optima 60

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Build your own: Track Display

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

CS Height Adjustable Desks ELECTRIC HEIGHT ADJUSTABLE SIT-STAND DESKS // DESK FRAMES

Distributed Design Series

Transcription:

T R A I N I N G W O R K S U R FA C E A N D S U P P O RT B A S I C S...........9 0 T R A I N I N G TA B L E B A S I C S.............................9 2 A C C E S S O RY B A S I C S.................................9 3 E D G E T R I M S T Y L E O V E RV I E W.........................9 4 89 U S E R E D G E & G R A I N D I R E C T I O N......................9 4 SUPPORT COMPATIBILITY CHART........................9 5 C O L L A B O R AT I V E W O R K S U R FA C E S H A P E S.................9 6 M O D E S T Y PA N E L D E TA I L S............................9 7 E L E C T R I C A L T R AY & C A B L E T R AY D E TA I L S................9 8 M O D E S T Y PA N E L & E L E C T R I C A L T R AY C O M PAT I B I L I T Y C H A RT..9 9 P L A N N I N G W I T H TA B L E S C R E E N S & L AT E R A L S C R E E N S......1 0 0 ACCESSORY COMPATIBILITY CHART.....................1 0 1 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S B A S I C S.......1 0 2 F I N I S H P ROTO C O L................................1 0 3

training training worksurface and support basics The following diagrams highlight Support and Modesty Panel options for the Training Tables Please refer to the Work Tools section for Focus Wall products and Storage section for Storage Products. (CTRT) and Cockpit (CTCK) 29" from floor to top 29" of finished worksurface Are ideally suited for classroom or training room like configurations 24" or 30" d 36" to 84" w Support Options Four leg styles are available for use with Training Tables 18" to 30" d All can be used on their own or in shared applications For compatibility between worksurfaces and legs, please refer to compatibility chart 36" to 84" w CTCK Fixed-Height Legs C-Leg T-Leg Int Leg Adjustable Height Option CTRT Standard (D) n/a Large Project Cart (AFAL) Focus Wall Arched (A) Slender (S) Post Leg (P) n/a n/a n/a C-Legs Casters and levelers can be specified on all legs except Intermediate Legs Modesty Panels (CTLM, CTMM) Used with most worksurfaces; see Compatibility Chart for application to the various shapes of worksurfaces Available in Laminate or Metal applied. Actual width will differ depending on the leg type Access door can be secured using a screw supplied on the modesty panel assembly Metal is available in Solid or Embossed Available with or without a built-in cable tray; the Cable Tray (CTWT) or Electrical Tray (CTET) can also be specified separately, the latter is not compatible with built-in tray When specifying the Modesty Panel, select the width to match the width of the worksurface to which it is being Laminate closed with Built-In Cable Tray without Built-In Cable Tray Metal closed Metal opened Post Leg has a 75 mm caster C-Legs and T-Legs have a 60 mm caster Levelers have a leveling range of 1" for the Standard (D) and Slender Legs (S) and 1/2" for the Arched Leg (A). When casters are specified, one caster is lockable All except Standard Legs are available in an Adjustable Height version (1" increments) that includes a securing device 26" to 34" from floor to top of finished worksurface 24" to 32" from floor to top of finished worksurface with levelers with casters Also Available: Modesty Panels for Flip-Top Table (CTLMF, CTMMF) Used with Flip-Top Table (CTFT) only Available in Laminate or Metal Metal is available in Solid or Embossed Cable Tray (CTWT) or Electrical Tray (CTET) can be specified separately When specifying the Modesty Panel, select the width to match the width of the table to which it is being applied; actual width will be smaller Includes a securing device Laminate Metal A concealed roller (1 caster, 1 leveler) is offered for the Arched Leg style. The roller option includes one leveler and one unlockable roller. This permits movement when the worksurface is lifted at one end and keeps the worksurface stationary when at rest

training worksurface & support basics (continued) The following diagrams highlight worksurface shapes, linking options, and Power/Data alternatives for the training tables. Please refer to the Storage section for Audience Storage products and the Work Tools section for Focus Wall products. Shapes Are provided in order to be able to plan collaborative work environments Intermediate Legs Specified only as a secondary support for specific worksurfaces May be used as a shared support to create corner configurations, but cannot be used to support a worksurface independently or to create rows of linked worksurfaces CTTA CTHM CTMZ CTCH CTQM Secondary Support Shared Support Audience A.V. Cart Focus Wall Linking Tables For permanent configurations, worksurfaces can be linked together using a shared leg For more temporary or casual applications, tables can either be casually clustered together on their own or with the use of the Quick Release Linking System (CAQR) Shared Leg Audience Credenza Quick Release Grommet in center (C) Grommets or Power/Data Center Can be specified when worksurfaces or tables are ordered. The surface will come with pre-drilled holes for easy installation on site Eight options are available Additional Grommets (CTGM) or Power/Data Centers (CLMP) can be field-installed and must be specified separately The Power/Data Center provided with worksurfaces and tables has a 120" long cord Grommet on left and right (E) Power/Data Center on left (F) Grommet on left (B) Grommet on right (D) 12 1/2" * Power/Data Center in center (G) 12 1/2" * * 15" for Height-Adjustable Tables Power/Data Center on right (H) Power/Data Sphere (CLPS) Can be field-installed to provide Power and Data access on both sides of the table in collaborative set up Data/Data Data/Power Power/Power

training table basics Within the training tables offering, several table options can be specified for more casual use. All Training Tables are sold as complete tables but are shipped knocked down All Training Tables can be specified with Grommets or Power/Data Centers 29" from floor to top of finished worksurface 42" to 84" w 24" or 30" d The worksurface of the Flip-Top Tables (CTFT) lock in both flat and upright positions. An activation handle is standard underneath the surface at the back edge and can be operated with one hand at any point along the surface. When a modesty panel (CTLMF, CTMMF) is installed, it activates the handle Modesty Panel Activation Handle This table accepts the Modesty Panel for Flip-Top Table (CTLMF, CTMMF) only. Can also accept the Electrical Tray (CTET) or Cable Tray (CTWT) at the same time as the modesty panel Can be nested together for storage. For example six tables will store into a space 53" wide Available in fixed height leg styles and options shown on the right Come with two lockable and two non-lockable casters C-Leg Standard Arched Slender T-Leg 36" to 84" w 24" or 30" d C-Leg 24" to 36" from floor to top of finished worksurface Height-Adjustable Tables (CTHT) Provide crank height adjustment from 24" to 36" Widths dimensions are 1" shorter than specified to allow for heightadjustment clearance and cable management Low-torque mechanism allows for minimal effort with only five turns per inches of adjustment. The mechanism can be operated on each side of worksurface (left or right) Available in fixed height leg styles and options shown on the right Are not offered with casters Arched Leg is available with an optional concealed roller (1 caster/1 leveler) 1" Arched Slender 60" to 84" w 18" to 30" d C-Leg T-Leg Standard Folding Tables (CTFL) and Lightweight Folding Tables (CTLF) Are available with C-Legs or T-Legs Three fixed height (29") Leg Styles are available Standard (D), Arched (A) and Slender (S) Casters or Levelers can be specified on each of the leg styles Include two lockable casters when casters are specified The lightweight version comes with two integrated handles Arched Leg is available with an optional concealed roller Do not accept accessories Arched Slender Mobile Table Trolley (CTMT) Available to store or move up to 7 (1,000 lbs) Folding Tables stored vertically Finished in Black

accessory basics The following diagrams highlight Screens, Electrical Trays and Accessories available within the Training Table offering. Table Screens (CTDS) and Lateral Screens (CTLS) Can only be applied to and Cockpit s and the Height-Adjustable Table (CTHT) Cannot be applied when T-Legs are specified Cannot be applied to 18" deep worksurfaces 22" in height cannot be used when casters have been specified Fabric is not tackable Lateral Screens must be used in combination with a Table Screen PAX90, PAX, PAX and PAX cannot be applied to these screens Table Screen Lateral Screen 6 1/2" 10" CPU Holder CPU Holder (CTLP) Can only be installed on the Arched Leg Style Low-profile bottom provides appropriate venting for most CPU's. However, if vents are located on the side of the CPU, 1" should be allowed on either side for sufficient air flow Cannot be applied in combination with Folding Tables (CTFL, CTLF) and Flip-Top Tables (CTFL) If Vertical Leg Covers (CTVL) are mounted on Arched Leg Styles, the inside cover must be removed prior to mounting the CPU Holder Wire Management Hook Electrical Tray (CTET) Can be used with a Modesty Panel (without built-in cable tray) Allows for front or user access to Power and Data Several electrical components such as the Under- Plug-In Power Bar (RLPP), the Under- Power Outlet (CLWP), the Splitter Box (RLBX) or the Data Box (CLDB) can be attached directly to the electrical tray See Compatibility chart for application to the various shapes of s 12" w Cable Tray (CTWT) Can be placed on any product Is mounted below a worksurface to manage cables coming from the worksurface level Under- Plug-In Power Bar (RLPP) can be attached to the Cable Tray Vertical Wire Management Cover Vertical Wire Management Covers (CTWC) Are 15" in height and are used only on the Slender Leg Style Vertical Leg Cover Vertical Leg Covers (CTVL) Vertical Leg Covers can only be mounted on the Arched Leg Style Vertical Leg Covers can be mounted to both sides of an Arched Leg Style to hide exposed cables If leg covers (CTVL) or Wire Management Covers (CTWC) are required for Folding Tables, they must be removed before folding under the worksurface When Specifying Vertical Leg Covers with cable management, only one cover gets cable management hooks

edge trim style & overview The chart below indicates which edge trim styles can be specified with Training all Tables Tables surface surface finishes. The Flintwood Straight Trim (7) will automatically default to match the surface finish color selected. Training Table worksurfaces are 1 3/16" thick Foundation Flintwood Non-User Laminate Surface Surface Edge Straight Trim (6) n/a Straight Trim (6) All Edges Bullnose Trim (2) User Edge Only n/a Finished in a coordinating Straight Trim Flintwood Straight Trim (7) All Edges n/a Flintwood Straight Trim (7) user edge & grain direction Shading indicates user edge. * (CTRT) Cockpit (CTCK) Trapeze Angular (CTTA) Half-Moon (CTHM) Mezzanine (CTMZ) Curved Hatchet (CTCH) Quarter-Moon (CTQM) * Folding Tables (CTFL) Lightweight Folding Tables (CTLF) Flip-Top Tables (CTFT) Height-Adjustable Tables (CTHT) * Only available with Straight Trim

support compatibility chart The chart below shows the compatibility between worksurface shapes and supports within the Training offering. s (CTRT) Cockpit (CTCK) Trapeze Angular (CTTA) Half-Moon (CTHM) Mezzanine (CTMZ) Curved Hatchet (CTCH) Quarter- Moon (CTQM) Legs Fixed Height 3, 6 6 4 3, 6 3, 6 3, 6 3, 4 Post Leg (CTPL) Intermediate Leg (CTST) T-Leg (CTTL) C-Leg (CTCL) Adjustable Height Fixed Height Adjustable Height Fixed Height Adjustable Height Fixed Height Adjustable Height 3 3 3 3 3 5 5 4 5 1, 2 1, 2 5 1, 2 1, 2 1 1 1, 4 1 Compatible Not Compatible 1 = The Intermediate Leg may only be used when worksurfaces are linked. 2 = The Intermediate Leg may be used as a secondary non-linking support (only for 24" and 30" deep worksurfaces). 3 = Available for 24" and 30" deep worksurfaces only. 4 = The Standard Leg style cannot be installed on this worksurface. 5 = The 18" T-Leg can be used as a secondary non-linking support. 6 = The Standard Leg style can only be installed on 24" deep worksurfaces.

collaborative worksurface shapes The following illustrations demonstrate how to use many of the shapes in shared applications. 1" Half-Moon & Mezzanine s Must be linked to other worksurfaces of the same width using shared supports These products cannot be used as a stand alone worksurface An Intermediate Leg or T-Leg must be specified as a third support These worksurfaces do not accept any accessories For back-to-back screen applications, please specify 1" wider Three Post Legs can be used to support these worksurfaces (2 in shared position plus 3rd post leg) Curved Hatchet & Quarter-Moon s Must be linked to other worksurfaces of the same width using shared supports These products cannot be used as a stand alone worksurface These worksurfaces do not accept any accessories The Quarter-Moon worksurface does not accept the "Standard" Leg Style

modesty panel details Training offers modesty panels mounted under the worksurface between supports to provide seated privacy. To determine compatibility between Modesty Panels and s, please refer to the Accessory Compatibility Chart in this section Modesty panels do not provide structural support Modesty Panels (CTLM, CTMM) Modesty Panels for Flip-Top Table (CTLMF, CTMMF) Securing Device Provide a 1/2" gap for cable access between the Modesty Panel and the worksurface 1/2" 1/16" Modesty Panels (CTLM, CTMM): Support configuration must be specified to ensure that the correct actual width is provided (H) for application on a Height-Adjustable Table (CTHT) only (P) for application on tables with Post Legs (S) for application on tables with C-Legs, T-Legs or Intermediate Legs Training electrical products (RLPP, CLWP, RLBX) can be installed on a Modesty Panel wider than 42" with built-in cable tray Not compatible with Flip-Top Table Modesty Panels for Flip-Top Table (CTLMF, CTMMF): The width specified must be equal to the worksurface width; actual width will be smaller 1/8" 7 1/4" Shared configuration cannot be achieved with Modesty Panels for Flip-Top Table (CTLMF, CTMMF)

electrical tray & cable tray details Training offers products that provide easy cable management on tables with or without modesty panel. To determine compatibility between Electrical Trays, Cable Trays and s, please refer to the Accessory Compatibility Chart in this section Electrical Tray Application With Modesty Panel Without Modesty Panel Electrical Tray (CTET): Can be installed for user or back access; if a power module is installed, only back access is possible Support configuration must be specified to ensure that the correct actual width is provided (H) for application on a Height-Adjustable Table (CTHT) and Flip-Top Table (CTFT) (P) for application on tables with Post Legs (S) for application on tables with C-Legs, T-Legs or Intermediate Legs Electrical components such as the Under- Plug-in Power Bar (RLPP), the Under- Power Outlet (CLWP), the Splitter Box (RLBX) and the Data Box (CLDB) can be fixed directly into the electrical clips that support the tray cover User Access Back Access Cable Tray Application Cable Tray (CTWT): Value alternative to a Electrical Tray (CTET) More than one tray can be specified under the same table Only Under- Plug-in Power Bar (RLPP) can be attached directly to this product With Modesty Panel Without Modesty Panel Under- Plug- In Power Bar (RLPP) Cable Tray (CTWT)

modesty panel & electrical tray compatibility chart The chart below will help determine compatibility between Modesty Panels, Electrical Trays and s. accessory widths Electrical Tray (CTET) Modesty Panels (CTLM, CTMM) Modesty Panels (CTLMF, CTMMF) worksurface/table widths (CTRT) OR Cockpit (CTCK) OR Height- Adjustable Table (CTHT) 36" 36" n/a 42" 42" n/a 48" 48" n/a 54" 54" n/a 60" 60" n/a 66" 66" n/a 72" 72" n/a 78" 78" n/a Trapeze Angular (CTTA) Flip-Top Table (CTFT) * Not available with Post Legs 84" 84" n/a 20 30 50 60 36" 24"* n/a n/a n/a n/a 42" 30" 24"* n/a n/a n/a 48" 36" 30" n/a n/a n/a 54" 42" 36" 24"* n/a n/a 60" 48" 42" 30" 30" n/a 66" 54" 48" 36" 36" n/a 72" 60" 54" 42" 42" n/a 78" 66" 60" 48" 48" n/a 84" 72" 66" 54" 54" n/a 36" n/a n/a n/a 42" 42" n/a 42" 48" 48" n/a 48" 54" 54" n/a 54" 60" 60" n/a 60" 66" 66" n/a 66" 72" 72" n/a 72" 78" 78" n/a 78" 84" 84" n/a 84" Accessories listed above are not compatible with: Half-Moon (CTHM) Curved Hatchet (CTCH) Mezzanine (CTMZ) Quarter-Moon (CTQM) Small-Convex (CTQM) and Lightweight Folding Table (CTFL and CTLF)

planning with table screens & lateral screens Table Screens (CTDS) and Lateral Screens (CTLS) can be installed on (CTRT) and Cockpit s (CTCK) or the Height-Adjustable Table (CTHT) and are offered in Fabric, Metal and Translucent finishes that finish both sides of the screen. Cannot be applied when T-Legs are specified Do not accept PAX90, PAX, PAX or PAX Fabric screens are not tackable Please refer to the Accessory Compatibility Chart in this section for details 36" Table Screen Lateral Screen Full Size Back (screen matches width of the worksurface) 1-1/4" 36" Table Screens are installed in front of the back edge without any gap Recessed Size Lateral (specify the screen the same depth of the worksurface) Lateral Screens always create a 1 1/4 " gap at the front to clear Bullnose trim style application 22 3/4" 24" 25" 36 5/32" Can be linked screens using the supplied linking piece. Please see the different configurations below: Double Configuration Triple Configuration Table Screen Lateral Screen Quadruple Configuration 1x Table Screen 1x Lateral Screen 2x Table Screen 2x Table Screen 1x Lateral Screen 1x Table Screen 2x Lateral Screen 2x Table Screen 2x Lateral Screen 22" 18" Cannot be applied to 18" deep worksurfaces or tables 22'' height cannot be used with worksurfaces where the C-Legs are installed with casters The Lateral Screen cannot be used alone. It must be linked to a Table Screen Two Table Screens cannot be installed in 90º configurations

accessory compatibility chart accessories * Must be used with the same worksurface width. CPU Holder (CTLP) Electrical Tray (CTET) Modesty Panels (CTLM, CTMM) Modesty Panels (CTLMF, CTMMF) Table Screens (CTDSF, CTDST, CTDSM) Lateral Screens (CTLSF, CTLST, CTLSM) Quick Release Linking System (CAQR) * Cable Tray (CTWT) worksurfaces (CTRT) 1, 2 3 4 Cockpit (CTCK) Trapeze Angular (CTTA) 6 5 2 3 4 4 Half-Moon (CTHM) Mezzanine CTMZ) Curved Hatchet (CTCH) Quarter-Moon (CTQM) tables Folding Table (CTFL) Lightweight, Folding Table (CTLF) Flip-Top Table (CTFT) Height-Adjustable Table (CTHT) 6 3 4 Compatible Not Compatible 1= 18" deep worksurfaces are not applicable 2 = T-Legs are not applicable 3 = Applicable with Table Screen only 4 = 18" deep tables are not applicable with Post Legs 5 = 24" wide modesty panels are not compatible with Post Legs 6 = To specify the width, refer to the Modesty Panel & Electrical Tray Compatibility Chart in this section

lighting, electrics & communications basics Training offers several ways to organize cabling and electrics under tables and worksurfaces. All electrical products can be installed into the Electrical Tray (CTET) or lay into modesty panels with built-in cable tray (CTLM, CTMM) Power/Data Center (CLMP) Can be placed on any product Is field-installed; it is the responsibility of the installer to avoid any interference Data Box (CLDB) Under- Plug-in Power Bar (RLPP) Can be attached to the Cable Tray (CTWT) Under- Power Outlet (CLWP) Splitter Box (RLBX) Pass-Through (CLPH) Base Feed (CLBF) Data/Data Data/Power Power/Power Pass-Through (CLPH_018) Under- Power Outlet (CLWP) Pass-Through (CLPH) Under- Power Outlet (CLWP) Base Feed (CLBF) 1/2" trade size straight connector Power/Data Sphere (CLPS) Can be placed on any product Is field-installed; it is the responsibility of the installer to avoid any interference Can be used when you need access on both sides of the table in a collaborative set-up. It is its main advantage compared to Power Module (CLMP) Under- Power Outlet (CLWP) Under- Power Outlet (CLWP) When needed, two Under- Power Outlets (CLWP) can be connected together To specify the correct length of the Pass-Through, calculate the dimension from the center of the worksurface to the center of the adjacent worksurface minus 12" All worksurfaces and tables must be linked together when electrical & communication products are installed

finish protocol The following diagrams show the various Teknion Fabrics and Finishes available on Training Tables. Each worksurface has metal inserts to accommodate the installation of worksurface supports and modesty panels Pre-drilled holes are done to accommodate screen and Electrical Tray installation Surfaces wider than 54" include 1 or 2 reinforcing bars Straight Trims (6) and Bullnose Trims (2) are available in a variety of Edge Trim Colors. Flintwood surfaces will come with edges that match the surface color s and Table Tops Are available in Foundation Laminates and Flintwood stains Constructed of high-pressure laminate applied to a 1 1/8" thick baseboard for a total surface thickness of 1 3/16" (except for the Lightweight Folding Table CTLF) Modesty Panels Metal (CTMM) and Modesty Panels for Flip-Top Table Metal (CTMMF) Can be specified in Foundation, Accent or Mica colors Offered in Solid or Embossed Embossed is offered with four patterns: Modesty Panels Laminate (CTLM) and Modesty Panels for Flip-Top Table Laminate (CTLMF) Can be specified in Source Laminates, Foundation Laminates or Flintwood stains Hardware is available in Foundation or Mica colors Edge Trims Are offered in Bullnose Trim (2), Straight Trim (6), Flintwood Straight Trim (7) available in a selection of Edge Trim colors or Flintwood Stains (where applicable) Flintwood Straight Trim (7) is only available with Flintwood worksurfaces Edge trim will match the worksurface color Wood print edge trim finishes are not available when Bullnose Edge Trim Style is selected Square Solo (201) Louvered Solo (305) Dot Solo (401) Large Dot (402) C-Legs (CTCL), T-Legs (CTTL), Intermediate Legs (CTST), and Post Legs (CTPL) Are available in Foundation or Mica colors Levelers are Black Casters are Black with Platinum covers Corner Details Radius (R) Corner detail option is only available when Straight Trim (6) is specified Standard (S) Radius (R) Screens can be specified in Foundation, Mica or Accent metal colors, Frosted translucent, or panel fabric from Teknion s Standard Panel Fabric Program Table Screen Grommets (CTGM) Are available in Source Laminates (Wood Prints only) or Foundation and Mica color. Source Laminate Grommets should not be specified with Flintwood worksurfaces Power/Data Center (CLMP) Available in Soft Gris (B) or Ebony (E) colors Lateral Screen Fabric Metal Translucent Fabric Metal Translucent

casual tables