English TEL: Before operating refer to the instruction manual! Any person entrusted with the set-up or operation of the device, must have

Similar documents
User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SCALE & WEIGHT DISPLAYS

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

C-net WIND. User s Guide

multi-function meters

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Inductive sensor BI1.5-EG08K-Y1

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Inductive sensor NI3-EG08K-Y1-H1341

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor NI10-M18-Y1X-H1141

Level Measurement silometer FMC 420, FMC 423

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

SAUTER flexotron RDT405 Manual

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

4 Wiring Brochure Wiring and installation of specific control

Process Transmitter RMA 422

Inductive sensor With analog output BI15-M30-LI-EXI

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Operating instructions Electronic preset counter Type series 717

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

MICROMASTER Encoder Module

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Process transmitter RMA422

3 Cleaning. 4 Technical data

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

INSTALLATION & USER GUIDE

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Installation Guide VL-MV10. Model No.

FB10000 Error Messages Troubleshooting

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

C200H-AD002/DA002 Analog I/O Units Operation Guide

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

VK-P10SE WARRANTY REGISTRATION FORM

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

USER MANUAL Full HD Widescreen LED Monitor L236VA

HS-509 VIBRATION TRIP MODULE

Installation Operation Maintenance

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

ABB Instrumentation Operating Instructions Series Transmitters. Second Retransmission Output Supplement All Models.

MT03A Electronic converter for flow rate transmitters

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Winmate Communication INC.

Operating instructions

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

USER MANUAL Full HD Widescreen LED Monitor L215ADS

DLP200M 2 Relay Module for Heating and Cooling Plants

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Capacitance Level Measurement Electronic insert FEC 12

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

T775U Series 2000 Electronic Stand-Alone Controller

Electronic converter for level transmitters MT03L Instructions manual

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Benefits. Applications

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Sensopress LCD Special English

Capacitance Limit Detection nivotester FTC 420/421/422

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Transcription:

699 TEL:755-83376549 Relative, vacuum and differential pressure transmitter Operating instructions TEL: 755-83376489 Huba Control AG - 699/full - Edition 8/22-457

English TEL:755-83376549 Before operating refer to the instruction manual! Any person entrusted with the set-up or operation of the device, must have read and understood this operation manual, in particular all safety notes.the guarantee is invalid in respect of damage resulting from a failure to follow the instructions, incorrect handling or inappropriate use. We accept no responsibility for consequential damages resulting from any of the above. Safety information General information In order to ensure safe operation, the device may only be operated in accordance to the specifications stated in this operation manual. Futhermore, all legal and safety regulations concerning this specific application should be observed.this also applies to the use of accessories. Correct use to the intended purpose These devices are designed for indication and monitoring of process variables. All other forms of usage do not comply with the intended purpose. These sensors may not be used solely as means for prevention of dangerous machine and system conditions. Machines and systems must be constructed in such a way, that faulty states cannot lead to a dangerous situation for the operating staff (e.g. due to independent limit switches, mechanical interlocking devices, etc.). Qualified staff The devices may only be installed, connected, set-up and operated by qualified staff and in compliance with the technical specifications. Qualified staff is defined as persons, who are familiar with set-up, mounting, start-up and operation of this device and who possess a recognized degree or certificate of appropriate professional training. Remaining hazards These sensors employ state-of-the-art technology and are safe to operate. However, if they are installed and operated by unqualified staff, an element of risk remains. In this manual the remaining risks are marked by the following symbol: This symbol is posted where there is a risk of serious injury or death or the damage of material and property, if the warning is ignored TEL: 755-83376489 2 Huba Control AG - 699/full - Edition 8/22-457

Installation and set-up instructions Even though the device is excellently protected against electro-magnetic interference, installation and cabling must be carried out correctly to ensure interference immunity. TEL:755-83376549. Use shielded cables for the signal and control lines with the connecting lead of the screen being kept as short as possible. The connection point of the shielding depends on the existing connection conditions. 2. Never route signal and control cables together with the trunk line or feeder cables of motors, cylinder coils, rectifiers etc. The cables must be routed in conductive and grounded cable conduits. This applies especially to long-distance cables, or environments in which the cables are exposed to strong radio waves from broad casting stations. 3. Signal lines should be installed in mounting cabinets and as far away as possible from contactors, control relays, transformers and other sources of interference. 4. Fix plug screw only with closed cover Mounting Prior to mounting or removing the sensor it must be verified that the system is depressurized. Do not mount sensors in locations subject to high pressure pulses. Significant thermal changes in the sensor environment can lead to a zero shift. As a result, the measuring value displayed in a depressurized state will not read zero. This kind of drift can be corrected by zero point reset. Supply from SELV or class 2 source limited energy circuit 5 W or less Use Copper conductors only Further information Voltage version... 5,... V Please consider a possible fall of voltage in the GND supply especially in connection with the use of the display and display lighting. Recommended is a short cable with a large crosssection. To prevent over-heating the display lighting swtiches off automatically with higher temperatures. TEL: 755-83376489 Huba Control AG - 699/full - Edition 8/22-457 3

Installation arrangement TEL:755-83376549 Recommended installation arrangement: vertical, with pressure connections facing downward, drain of possible condensed water (factory calibration). Notice: Mount the transmitter with minimum mm distance to magnetic material. If this is not possible there is a failure of up to minus Pa for transmitters mounted on sheet steel. ZP = Push Zero point reset. ZP The installation position is variable by using the zero point reset button. Pressure variations are resettable after installation. Ensure the power supply is not interrupted when storing customer settings (ZP reset,). Connection diagrams TEL: 755-83376489 2 wire 3 wire Universal 2 and 3 wire 4 Huba Control AG - 699/full - Edition 8/22-457

Version with measurement configuration only (Adjustability ) TEL:755-83376549 2 3. DIP-Switch (dual) 2. Zero point reset 3. Connecting terminals 4. Pressure connectors P and P2 4 Pressure range ) Range Range Range customer adjustment 2) 3) ) Pressure range TEL: 755-83376489 2) Customized factory adjustment 3) DIP-Switch position according to factory adjustment (see inside cover) Huba Control AG - 699/full - Edition 8/22-457 5

Complete configurable version TEL:755-83376549 (Adjustability 2) 2 7 3 5 4 (Adjustability 3 - with display) 2 6. DIP-Switch (tenfold) 2. Zero point reset 3. Connecting terminals 4. Pressure connectors P and P2 5. Turbo potentiometer (Signal amplifications potentiometer) 6. LCD (by adjustability 3 only) 7. LCD receptacle 3 5 TEL: 755-83376489 4 6 Huba Control AG - 699/full - Edition 8/22-457

Adjustable pressure ranges TEL:755-83376549 ) Pressure ranges 2) DIP-Switch position according to factory adjustment (see inside cover) 2 3 4 5 6 7 8 9 2) Factory Settings Pressure Range range ) Range Range Output... V 3W... 2 ma 3W 4... 2 ma 3W 4... 2 ma 2W Filter off: / on: x Signal linear: / root extracted: x DIP-Switch position 2 switchable pressure ranges Range (in mbar).5 3 5 6 25 5 2 2 Range (in mbar).3.5 3 5 6 25 Range (in mbar).3.3.5 3 5 6 output signal % TEL: 755-83376489 linear % Pressure range Huba Control AG - 699/full - Edition 8/22-457 7

Adjustable full scale pressure inside the pressure ranges TEL:755-83376549 With turbo potentiometer it`s possible to make additional continuously variable adjustment inside the pressure ranges. 27À output signal % ouput signal % linear % Pressure range linear % Pressure range TEL: 755-83376489 8 Huba Control AG - 699/full - Edition 8/22-457

Adjustable output signals TEL:755-83376549 Factory Settings 2 3 4 5 6 7 8 9 Pressure Range range Range Range Output )... V 3W... 2 ma 3W 4... 2 ma 3W 4... 2 ma 2W Filter off: / on: x Signal linear: / root extracted: x ) four possible setting options, otherwise an output error may occur DIP-Switch position output signal Connection diagrams 3 4 5 6 7 8... V... 5 V* 3 wire 3 4 5 6 7 8... 2 ma 3 wire 3 4 5 6 7 8 4... 2 ma 3 wire 3 4 5 6 7 8 2 wire 4... 2 ma TEL: * -5V only possibile with adjustability 3 - adjust via menu control 755-83376489 Huba Control AG - 699/full - Edition 8/22-457 9

Adjustable filter fuction 2 3 4 5 6 7 8 9 Factory Settings TEL:755-83376549 Pressure Range range Range Range Output... V 3W... 2 ma 3W 4... 2 ma 3W 4... 2 ma 2W Filter off: / on: x Signal linear: / root extracted: x DIP-Switch position 9 9 % Filter off Filter on ( sec.) other response time on request ATTENTION: Filter ıon = Other filter response time are selectable via software - only 63% possible with adjustability 3 (see menu control) TEL: 755-83376489 time τ Huba Control AG - 699/full - Edition 8/22-457

Adjustable reponse curve 2 3 4 5 6 7 8 9 Factory Settings TEL:755-83376549 Pressure Range range Range Range Output... V 3W... 2 ma 3W 4... 2 ma 3W 4... 2 ma 2W Filter off: / on: x Signal linear: / root extracted: x DIP-Switch position output signal % linear response curve linear % Pressure range output signal % root extracted TEL: 755-83376489 % Pressure range Huba Control AG - 699/full - Edition 8/22-457

Menu control long keypress short keypress 控制 ttp://www.sensor-ic.com/ TEL:755-83376549 FAX:755-83 E- 化 tp://www.sensor-ic.com/ TEL: 755-83376489 FAX:755-83 E-

控制 ttp://www.sensor-ic.com/ TEL:755-83376549 FAX:755-83 E- 化 tp://www.sensor-ic.com/ TEL: 755-83376489 FAX:755-83 E-

Menu descriptions TEL:755-83376549 Normal Display Pressure display in selected pressure range Turbo-Poti Display Unit Output signal Output attitude Display full scale pressure adjustment by turpopotentiometer Selection of display the pressure or % full scale Select pressure unit (no direct conversion of the pressure unit - see order code selection table) Select the output signal Parallel moving or adjustment of pressure range Out % Out % Zero @ % - % Pressure 9% % % Pressure % Out % Max. under pressure -mbar Zero @ 5% TEL: 755-83376489 -% % % Pressure 4 Huba Control AG - 699/full - Edition 8/22-457

Filter Select response time at pressure changes TEL:755-83376549 Display light Select light - on/off and automatic power shut-off after 5 min. Serial number Product information - reference only Factory Adjustment Software reset to factory setting according specification plate and DIP-Switch position TEL: 755-83376489 Huba Control AG - 699/full - Edition 8/22-457 5

Angaben auf TEL:755-83376549 Leistungschild (Druckbereich, FAX:755-83 Ausgang/Speisung, E- Anschlussschema und Artikelnummer) entsprechen der Werkseinstellung. Aufgrund von kundenseitiger Konfigurationen können die Einstellungen von diesen Angaben abweichen. Bevor das Gerät konfiguriert wird, sollte die Bedienungsanleitung beachtet werden. The factory setting information (pressure range, output / power supply, connection diagram and article no.) is located on the specification label. Because of customer configuration the settings can differ from this information and before the device is configured please refer to the operating manual. Les données présentes sur la plaque signalétique (plage de pression, sortie/alimentation, schéma de raccordement et numéro dêarticle) correspondent au réglage dêusine. En raison dêune configuration personnalisée du client, les réglages peuvent être différents de ces données. Avant de configurer lêappareil, il convient de tenir compte du mode dêemploi. Elektromagnetische Verträglichkeit Electromagnetic compatibility Compatibilité électromagnétique CE-konform gemäss EN 6326-2-3. CE conformity TEL: 755-83376489 according EN 6326-2-3. Conformité (CEM) selon EN 6326-2-3. 6 Huba Control AG - 699/full - Edition 8/22-457