SYSTIMAX GigaSPEED XL Solution

Similar documents
SYSTIMAX GigaSPEED XL Solution Guide

SYSTIMAX Solutions. GigaSPEED. Solution Guide.

Belden IBDN System 10GX The next level of cabling performance

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Uniprise Solution Brochure. North America/CALA.

Belden IBDN System 10GX Enabling Technologies

What really changes with Category 6

CAT6Plus System. Brand-Rex Limited

LAN Cabling Systems Copper

GigaSPEED X10D F/UTP. SYSTIMAX solutions

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Connect with the industry s best CAT6 and CAT5e channel solutions!

SECTION COMMUNICATIONS HORIZONTAL CABLING

VisiPatch 360. Technical Documentation. Key VisiPatch 360 System features and benefits SYSTIMAX SYSTEM

Data Communications Competence Center

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

CATEGORY 6A CABLING SOLUTIONS

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

CATEGORY 6A CABLING SOLUTIONS

Volition TM RJ45 K5e Jacks

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Microwave Backhaul Solutions SUPER HIGH PERFORMANCE ANTENNAS. Not just a new backhaul solution a whole new backhaul strategy

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Copper Cabling Troubleshooting Handbook

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Product Guide SYSTIMAX Structured Connectivity Solutions

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Category 5e F/UTP Euroclass D ca Cables

OMNI FIT Connectors and Universal Trimming Tools

PREMIUM 5e F/UTP PRODUCTS

40G SWDM4 MSA Technical Specifications Optical Specifications

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Do you know if your Cat. 6 patch cord has been tested according to standards?

Clarity Advanced Solutions6A

Challenges for testing 10GBASE-T

C6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A

FUTURE PROOF YOUR CONNECTIONS

REQUEST FOR PROPOSAL FOR Supply and Installation UTP Network in the following location

CATEGORY 6 CABLING SOLUTIONS

STRUCTURED CABLING SYSTEMS (SCS)

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

Agilent 87075C Multiport Test Set Product Overview

VGA Video Extender over Cat 5 with RS232

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

HDBaseT vs. IP. Bob Ferguson, RCDD, CTS I Belden Regional Sales Engineer Broadcast and Audio Video Group

384A Adapter Installation Instructions

TX COPPER CABLING SYSTEM

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

10GBASE-LRM Interoperability & Technical Feasibility Report

DESIGN!!GUIDELINES!!!!!

PATCH CORDS, PLUGS & CABLES

Detailed Specifications & Technical Data

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

GenSPEED Category 5e Cables 3

Detailed Specifications & Technical Data

Keyed LC Connector Solution A LANscape Solutions Product

40G SWDM4 MSA Technical Specifications Optical Specifications

Detailed Specifications & Technical Data

End-to-End Solutions for Large Venues

Indoor cabling LAN Cabling Systems

Table of Contents. Open Matrix System (OMS) 1-2

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

HDMI Video Extender over Cat5 RS232 and IR Control

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

The University of Texas at Austin September 30, 2011

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

LANmark. Copper Cabling Solutions

25% OFF Genuine Amphenol Coaxial Cables

Magic Patch Patch Leads & Accessories

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

The Telegärtner Group

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

MultiView 9D Cat5 Distribution Amplifier

FOSC 400. Fiber Optic Splice Closures

LYNX ULTRA Series Hubs and Baluns

Everything you always wanted to know about HDBaseT*

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

HDMI EXTENDER ELE8088

DSP-4000 Series. CableAnalyzer. Users Manual

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

ASP-FIBRS1 User Manual

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

Datasheet NVISION Compact Space and Cost Efficient Utility Routers

Request for Proposal (RFP)

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

HighBand 25. TrueNet Category 6 Solutions

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

CATEGORY 5e CABLING SOLUTIONS

User Manual. Model 1351 DVI Repeater with HDCP

Volition TM Category 5e cable 100 Ω, FTP

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Transcription:

SYSTIMAX GigaSPEED XL Solution The Culmination of a Relentless Pursuit of Excellence SYSTIMAX Structured Connectivity Solutions www.systimax.com

A study reported that 79% of employees use a company network. The study found that, on average, companies lose about 2% of annual revenues because of network problems.* These companies are asking questions: To give us a competitive advantage, can we reduce network downtime? Can we cut operating costs? Can our network handle new technologies to make us more efficient? Too often the answer is, Maybe or No. SYSTIMAX Solutions is proud to introduce the system that enables you to answer, Yes with absolute confidence. We call it the SYSTIMAX GigaSPEED XL Solution the culmination of a relentless pursuit of excellence. *Source: Cost of Network Downtime in the U.S., September 2000, Infonetics Research, Inc.

A Relentless Pursuit of Excellence The SYSTIMAX Labs Effect Most vendors offer mixed cabling systems, built from the bottom up. That is, they begin with a core component (cable, usually) and add components from other vendors to create a standards-compliant system. Even if each component is Category 6 compliant, the channel may not be because of design differences among components. The SYSTIMAX GigaSPEED XL Solution: It s not just new. It s news. 1 A survey by Infonetics Research confirmed something that has long been a motivating factor in our research nearly half of all LAN/WAN problems (43%) are caused by cabling or apparatus. Network inefficiencies caused by overstressed cabling cost the average company nearly $14 million per year in reduced productivity and lost revenues. To develop SYSTIMAX SCS, we ve taken the opposite, "top-down", true systems approach. We begin by setting specific performance objectives. Proprietary system-level design techniques allow us to visualize the optimum end result by setting the highest system performance requirements and bandwidth. Sophisticated modeling tools and exhaustive design research yield the optimal system-level and component-level parameters. Finally these specifications of quality and reliability are incorporated into the production of every component. Today we are proud to introduce the solution. With 41 patents, our newest generation of SYSTIMAX GigaSPEED XL Solutions offers everything you d expect from the world s leading copper cabling system performance far beyond Category 6 standards, cost-effective design innovations and reliability so robust it can help make network downtime a thing of the past. But one thing hasn t changed the fundamental design principles that assure compatibility among all SYSTIMAX Structured Connectivity Solutions (SCS) components. That means the GigaSPEED XL Solution you install today will support your legacy applications to help keep you functioning at peak performance, even as you migrate to tomorrow s technologies that require Category 6 compatibility. Meet the industry-leading connectivity solution in the world today Proprietary design and manufacturing techniques developed by SYSTIMAX Labs make GigaSPEED XL cabling one of the most reliable high-performance UTP media in the world. It can easily handle Gigabit Ethernet, 1.2 gigabit ATM, even 270 Mb/s Serial Digital Video and is backward compatible to keep your legacy applications running at peak efficiency. 1 Source: Cost of Network Downtime in the U.S., September 2000, Infonetics Research, Inc. 1

SYSTIMAX Solutions To assure that these specifications of quality and reliability are built into our products, we do something else no other vendor does. Using proprietary tools and techniques, we design, test and manufacture the entire channel cables, outlets, cords, patch panels as a single, tightly integrated system. Your PCs double in power every 2-3 years, driven by bandwidth-hungry applications. Your cabling which represents only about 5% of your network costs will have to handle massive traffic increases for 20 years. Would you rather gamble, or make a safe choice? We call this the SYSTIMAX Labs Effect. The result is a proven end-to-end solution precisely matched and balanced to be a network infrastructure you don t have to worry about for 20 years. Why Performance Matters Yesterday, network performance simply meant fast file transfer. Today, it s life or death for a network. Category 6 standards push UTP media to the limit. There is zero margin for error. Vendors that claim Cat 6 compliance often base that claim on the fact that individual components were able to achieve this performance, on average, in lab tests, at a specific frequency. Do you like to gamble? Average performance in lab tests does not take into account real-world conditions such as network congestion, less-than-perfect installation, and imbalance among components. In the real world, many systems simply will not have enough headroom to cope. Ask the Tough Questions In the trade magazines you ll see impressive claims from many companies. Read the ads, then evaluate them by asking a few difficult questions: Can the company guarantee significant channel margin over the entire frequency range, from 1 to 250 MHz? We can. Are performance claims valid for the entire network channel, end to end, from equipment closet to desktop? Ours are. Guaranteed. Does the company design, manufacture and test every component? Every channel? We do. The Big Question: Are advertised performance claims guaranteed in the warranty, for existing and future applications, for 20 years? Ours are. In today s economy, these are the questions that could determine your company s future. Be skeptical of long answers. We believe that only one company can answer all of these questions in one word: Yes. The Tools our Competitors Envy Most vendors measure the performance of individual components. But in real-life use, these figures have little meaning. At the ultra-critical tolerances required to run Category 6 applications, even a slight imbalance among Category 6-compliant components can cause frequent slowdowns and network failures. To build the world s most reliable cabling system, the scientists and engineers of SYSTIMAX Labs developed the most advanced network analysis tools in the world today: Modal Decomposition Modeling, Connector Field Pattern Modeling and Cable Twist Accuracy Technology. These proprietary tools and techniques allow us to match the performance characteristics of every component with a level of precision no other company can approach. We believe that this is the only way to assure full Category 6 performance throughout your complete network closet to desktop under all conditions. Which is why no other company warrants guaranteed worst-case channel performance claims in writing, like we do. 2

A Relentless Pursuit of Excellence The pipe may not be as fat as it appears Many vendors use components from several manufacturers. Even if each is Category 6 compliant, slight differences in design can cause signal reflections at the points where they join. These signal echoes reduce performance of the entire channel. SYSTIMAX GigaSPEED XL components are impedance-balanced to match precisely the only way to achieve peak channel performance and reliability from end-to-end. DATA Vendor A Patching hardware If not perfectly matched, components can reflect data signals where they join. Even if each component is Category 6 compliant, end-to-end performance can be greatly reduced. GigaSPEED XL PATCHMAX 1100 panels Vendor B Category 6 cabling GigaSPEED XL 71/81-series cabling Vendor C Information outlets GigaSPEED XL MGS400 outlets Vendor D Patch cords GigaSPEED XL GS8E patch cords DATA SYSTIMAX GigaSPEED XL components are precision engineered to provide a generous bandwidth margin that ensures absolute reliability through your entire channel. A Relentless Pursuit of Excellence How do SYSTIMAX Solutions TM offer the best protection for your investment in cabling infrastructure? It can t all be explained in this brochure, but here are a few important distinctions between us and our competitors: Manufacturing excellence: SYSTIMAX SCS quality control methods are so stringent that ISO-9001 specifications were based on standards we developed years before. This allows us to provide every customer on every continent with the same performance and reliability in every location. Industry-leading support: We believe we are the only company with the depth, the reputation and the worldwide resources to provide support when and where you need it with global sales facilities, 4-tier technical support and a network of highly trained BusinessPartners on every continent. Customer confidence: SYSTIMAX SCS is the most widely used cabling system in the world, according to independent researchers. Today, our cabling is being installed at a rate of more than 1,000 miles per day (1,600 km), in more than 120 countries. Why? The answer is very simple. We build the best, and we serve our customers well. Technological leadership: Virtually all UTP performance standards were based on our research Category 3, 4, 5 and 6, so far. SYSTIMAX SCS scientists and engineers are active participants in every major standards-setting organization in the world, and remain at the forefront of new standards development. 3

SYSTIMAX Solutions Near End Crosstalk (Pair-to-Pair NEXT) 1 to 250 MHz This chart shows just one of many reasons why our GigaSPEED XL Solution leads the industry, worldwide. Our proprietary system-level design techniques assure guaranteed channel margin across the entire frequency range. Category 6 Channel specification (TIA) Our GigaSPEED XL7 Solution exceeds the Category 6 standard by 6 db. Our GigaSPEED XL8 Solution exceeds it by 7 db. Both are so advanced that they can support 6 connection points with generous margin to spare over Category 6 specifications; (see table on page 5). Amplitude (db) GigaSPEED XL7 Solution: Typical performance Guaranteed performance Please note that these are guaranteed, end-to-end channel performance figures. We welcome comparisons to competitive solutions in the market place. Frequency (MHz) Category 6 channel specification (TIA) GigaSPEED XL7 Solution guaranteed channel performance GigaSPEED XL7 Solution typical channel performance Highlights from the Best Warranty in the Industry All GigaSPEED XL Solutions are backed by a 20-year Extended Product Warranty that we believe to be the best in the industry. Our Application Assurance covers everything from voice, data and video applications to standards-based complex building management systems by some of the world s leading manufacturers. We will specify the performance of each application not average, not nominal, as many companies do, but guaranteed worst-case channel performance and we will warrant that your certified SYSTIMAX GigaSPEED XL Solution will meet or exceed those specifications for 20 years. We Build Solutions. Ask us. We have far more to explain about how our systems can help solve your immediate and future challenges. Our research has yielded many innovative solutions that cannot be detailed in this small brochure. To learn more, please visit our Web site at www.systimax.com or contact your SYSTIMAX Solutions representative. We ll be glad to explain how we ve surpassed the expectations of companies large and small, around the world. And how quickly, easily and inexpensively we can do the same for you. GigaSPEED XL Solutions are so advanced that we can even guarantee the performance of applications that do not yet exist. Specifically, we will warrant any applications introduced by recognized industry standards-settings bodies or user forums that specify TIA/EIA 568B or ISO/IEC 11801 components and link/channel specifications for the pertinent cabling system. 4

A Relentless Pursuit of Excellence Performance of the GigaSPEED XL Solutions 4 Connector Channels: GigaSPEED XL7 GigaSPEED XL8 Worst Pair Margin (1-250 MHz) Worst Pair Margin (1-250 MHz) Guaranteed Typical Guaranteed Typical Insertion Loss 5.0% 6.5% 8.0% 9.5% Pr-Pr NEXT 6.0 db 9.4 db 7.0 db 10.9 db PSNEXT 7.5 db 10.6 db 8.5 db 12.0 db Pr-Pr ELFEXT 6.0 db 11.3 db 8.0 db 11.5 db PSELFEXT 8.0 db 12.7 db 10.0 db 13.2 db Return Loss 4.0 db 5.7 db 4.0 db 6.1 db GigaSPEED XL Solution performance with four connector channels. Figures valid at any frequency of certified channel comprising GigaSPEED XL cable & apparatus. 6 Connector Channels: GigaSPEED XL7 GigaSPEED XL8 Worst Pair Margin (1-250 MHz) Worst Pair Margin (1-250 MHz) Guaranteed Typical Guaranteed Typical Insertion Loss 4.0% 5.5% 6.5% 8.0% Pr-Pr NEXT 4.0 db 7.4 db 5.0 db 9.4 db PSNEXT 5.5 db 8.5 db 6.5 db 10.6 db Pr-Pr ELFEXT 4.0 db 8.9 db 6.0 db 9.4 db PSELFEXT 6.0 db 10.4 db 8.0 db 11.0 db Return Loss 2.0 db 5.2 db 2.0 db 5.9 db GigaSPEED XL Solution performance with six connector channels. Figures valid at any frequency of certified channel comprising GigaSPEED XL cable and apparatus. 5

2004 CommScope, Inc. All rights reserved. Visit our Web site at www.systimax.com or contact your local SYSTIMAX Solutions representative or SYSTIMAX BusinessPartner for more information. SYSTIMAX Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to SYSTIMAX Solutions products or services. 08/04 BR-B-2