Series description: Wilo-Drain VC

Similar documents
Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Series description: Wilo-Sub TWU 3 HS

Series description: Wilo-Jet HWJ

Immersion Pumps HCT (High Chem) sealless

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Immersion Pumps HCT (High Chem) sealless EN

Revision 2.0 Parts List Minor

Flygt D 8050, 50 Hz. Technical specification

Revision 2.0 Parts List Minette 1~, 3~

Revision 3.0 Parts List Salvador 1~, 3~

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

Gear Pump Units For single-line centralized lubrication systems

Okta 1000, Roots pump without motor

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

AC diagonal module Ø 200 mm

WILO BRINGS THE FUTURE.

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

2.9 Sigma/ 2 Plunger Metering Pumps

Gear Pump Units. For single-line lubrication systems

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Pumps, Systems and Components for Building Services, Water Management and Industry

Agilent High Capacity RV Pumps & Roots Pumping Systems

Revision 1.0 Parts List Minor

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Revision 1.0 Parts List Salvador 1~, 3~

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Single Point Flow Monitor SW118 SW119

Fluid Cooling P-BAR b Industrial BOL Series

Mechanical flow switch for On/Off control

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Screw pump Series ALLFUEL AFT

Revision 1.0 Parts List Mini

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Part-Turn Electric Multi-Turn Electric

Series: BPV, BPLHS. Vertical Multi-Stage Family Curve, 3500 RPM - 60Hz. Family Curves. Vertical Multi-Stage Pumps.

SMALL OIL SEALED PUMPS

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Panel-mounting thermostats, type series EM

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF 1020 Constant climate chambers with large temperature / humidity range

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

AS09..S 3-pole Contactors - Spring Terminals


TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Series: BPV, BPLHS Family Curves

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Model KBF 115 Constant climate chambers with large temperature / humidity range

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Bimetal Temperature Switch

istep STEPPER MOTOR PUMP

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Product Data Sheet 4656 EZ

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Page 1 of 7 Attachment to IECEx TUN Issue 0

Product Data Sheet 4656 ZW

Panel-Mounted Thermostat

PROPORTIONAL VALVES Sentronic plus

Revision 1.0 Parts List Mega

Portable Filter Cart Type SPFC

istep STEPPER MOTOR PUMP

VM GATE VALVE GRINDING & LAPPING MACHINE

Product Data Sheet 8506 VW-691

Parts List _2.1. Flygt /.190

Range of Borehole Products. Lenntech. Tel Fax

Magnetic Stirrers Magnetic Stirr

Parts List _2.1. Flygt /.890

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Electric Rotary Modules. Rotary Actuators

TUC: Universal thermostat

Model ED 23 Drying and heating chambers Classic.Line with natural convection

ih Series Drypumps (505) idealvac.com idealvac.com

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Up to 85% higher Service Life due to efficient sealing method.

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

TFRN Industrial RTD temperature sensor. CombiTemp TM

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

Model KBF 720 Constant climate chambers with large temperature / humidity range

Nessie Coils for VDH and VDHT valves

Lt DELTA USA, Inc

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Horn loudspeaker, Ex proof, short/long flare

Model KBF P 240 Humidity test chambers with ICH-compliant light source

DDF-SE. Application example. Feed-through Stationary Rotary Feed-through. Max. speed 500 revs/ min. Air feed-through Up to 6x

Type D mechanical diaphragm

GRUNDFOS alldos product information. The solution for complex dosing tasks

Transcription:

Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application Pumping of wastewater: Containing solid substances of max. Ø 5 mm or Ø 7 mm (VC 40) Fluids up to 95 C From pump sumps With condensate From basements at risk of flooding Attached float Capacitor box (VC 32), 1~ Materials Motor housing: Al Pump housing: EN-GJL-250 Impeller: 1.4028 (VC 32/10), EN-GJL-250 (VC 40/20) Shaft: stainless steel Floater: PP Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 1 / 8

Series description: Wilo-Drain VC Type key Example: Wilo-Drain VC 32/10 VC Vertical drainage pump 32 Nominal diameter of pressure port in mm 10 Max. delivery head in m Special features/product advantages Long service life Easy commissioning Connection outside the fluid Long downtimes possible Built-in motor protection by thermal relay Technical data Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz Protection class: IP 54 Fluid temperature: 3 95 C Free ball passage: 5 mm / 7 mm Pressure port: R 1 / R 1½ Description/design Vertical pedestal-type wastewater pump with mounted float switch for stationary installation. IE2 motor On completely flat floors Shaft always vertical VC 40 hanging from flange VC 32: On the motor VC 40: disconnected from motor Electrical data VC 32: 1~230 V with capacitor 40 µf VC 40: 3~230/400 V motor protection switch required onsite. Scope of delivery Pump with attached float switch and installation and operating instructions. Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 2 / 8

Duty chart: Wilo-Drain VC Pump curves H[m] Wilo-Drain VC 18 16 14 12 10 8 VC 40/20 6 4 2 VC 32/10 0 0 2 4 6 8 10 12 14 0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Q[m³/h] Q[l/s] Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 3 / 8

: Wilo-Drain VC Design Submersible Non-self-priming Open single-channel impeller Vortex impeller Open multi-channel impeller Turbulator Sealing chamber Sealing for mechanical seal on motor side Sealing for rotary shaft seal on motor side Sealing for mechanical seal on fluid side Sealing for rotary shaft seal on fluid side Single-phase AC motor Three-phase motor Direct activation Star-delta activation FC operation Dry motor Motor with oil cooling Sheath current cooling Application Wet well installation, stationary Wet well installation, portable Dry well installation, portable Dry well installation, stationary Explosion protection Hose connection Non-return valve Capacitor box for 1~230 V Connecting cable detachable Ready-to-plug = available or approved, - = not available or not approved Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 4 / 8

Product list: Wilo-Drain VC Pump type Mains connection Max. volume flow Max. delivery head Optimum volume flow Optimal delivery head Art no. Q max / m 3 /h H max / m Q opt / m 3 /h H opt / m VC 32/10 3~400 V, 50 Hz 7 10 5 7 2044583 VC 32/10 1~230 V, 50 Hz 7 10 5 7 2044582 VC 40/20 3~400 V, 50 Hz 16 20 10 15 2044584 Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 5 / 8

Data sheet: Wilo-Drain VC 32/10 (3~400 V) Pump curves Wilo-Drain VC - 50 Hz - 2900 rpm Unit Max. delivery head H max 10 m Max. volume flow Q max 7 m 3 /h Optimal delivery head H opt 7 m Optimum volume flow Q opt 5 m 3 /h Pressure connection R 1 Pump curves in accordance with ISO 9906, Appendix A Free ball passage Operating mode (non-immersed) 5 mm S1 Protection class IP 55 Fluid temperature T +3... +95 C Weight approx. m 36 kg Motor data Mains connection 3~400 V, 50 Hz Nominal current I N 1 A Nominal motor power P 2 0.37 kw Activation type Direct Nominal speed n 2900 rpm No. of poles 2 Insulation class F Max. switching frequency 50 1/h Cable Mains plug Explosion protection Materials Impeller 1.4028 Motor housing Pump housing Al EN-GJL-250 Information for order placements Make Wilo Art no. 2044583 EAN number 4016322640301 Ready for delivery Price group Stock W6 Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 6 / 8

Data sheet: Wilo-Drain VC 40/20 (3~400 V) Pump curves Wilo-Drain VC - 50 Hz - 2900 rpm Unit Max. delivery head H max 20 m Max. volume flow Q max 16 m 3 /h Optimal delivery head H opt 15 m Optimum volume flow Q opt 10 m 3 /h Pump curves in accordance with ISO 9906, Appendix A Pressure connection Free ball passage Operating mode (non-immersed) R 1½ 7 mm S1 Protection class IP 55 Dimension drawing Wilo-Drain VC 40 Fluid temperature T +3... +95 C Weight approx. m 77 kg Motor data Mains connection 3~400 V, 50 Hz Nominal current I N 2.90 A Nominal motor power P 2 2.20 kw Activation type Direct Nominal speed n 2900 rpm No. of poles 2 Insulation class F Max. switching frequency 50 1/h Cable Mains plug Explosion protection Materials Impeller Motor housing Pump housing EN-GJL-250 Al EN-GJL-250 Information for order placements Make Wilo Art no. 2044584 EAN number 4016322640318 Ready for delivery Price group Stock W6 Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 7 / 8

Data sheet: Wilo-Drain VC 32/10 (1~230 V) Pump curves Wilo-Drain VC - 50 Hz - 2900 rpm Unit Max. delivery head H max 10 m Max. volume flow Q max 7 m 3 /h Optimal delivery head H opt 7 m Optimum volume flow Q opt 5 m 3 /h Pressure connection R 1 Pump curves in accordance with ISO 9906, Appendix A Free ball passage Operating mode (non-immersed) 5 mm S1 Protection class IP 55 Dimension drawing Wilo-Drain VC 32 (1~230 V) 141 Fluid temperature T +3... +95 C Weight approx. m 36 kg Motor data Mains connection 1~230 V, 50 Hz Rp 1 Nominal current I N 3.90 A Nominal motor power P 2 0.37 kw Activation type Direct 160 610 250 max. min. 1020 1247 Nominal speed n 2900 rpm No. of poles 2 Insulation class F Max. switching frequency 50 1/h Cable Mains plug Explosion protection Materials Impeller 1.4028 Motor housing Al Pump housing EN-GJL-250 Information for order placements Make Wilo Ø230 300 Art no. 2044582 EAN number 4016322640295 Ready for delivery Stock Price group W6 Subject to change without prior notice. www.wilo.co.uk 50 Hz EU 2013-02 8 / 8