Read/Write Head TNLR-Q80L400-H1147L

Similar documents
Read/Write Head TNSLR-Q42TWD-H1147

Read/Write Head TN-CK40-H1147

Read/write head TN-CK40-H1147

Read/Write Head TN-M30-H1147

Read/write head TN-M18-H1147

Capacitive sensor BCT5-S18-UP6X2T-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Mobile data carrier TW-L49-46-F-B128

TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive coupling. 10 mm +/-0.2 mm

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Inductive sensor BI1.5-EG08K-Y1

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

EtherCAT Set in IP20 TI-BL20-E-EC-S-4

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

Set for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2

APPLICATIONS. Automatic warehouse. Trasportation lines

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

The full range of performance

Connectivity for Ethernet

APPLICATIONS. Automatic warehouse. Trasportation lines

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Pressure sensors with display

Your Global Automation Partner. Ultrasonic Sensors

Proportional output thumbwheels - sprung to centre

Fibre Optic Modem ODW-611

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Speed sensor MiniCoder GEL 2471

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Quality products from a single source

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Pluggable interface relays CR-M Miniature relays

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Fibre optic router for TP/FT-10 LRW-112PP

Inductive Proximity Switches. Sensing Distance mm. Itemgroup 230

Electrical connection

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

SERIES 400 SERIES 620

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Fibre Optic Modem ODW-622

Emergency lighting units EM powerled

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Electrical connection

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

ODW-621. RS-232 Point-to-point applications

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Photoelectrics Through-beam Type PA18C.T..., DC

Quality products from a single source

ENC - LKE51 - L I B

LONWORKS Fibre Optic Router

Electrical connection

>Inductive. REFERENCE guide. Proximity

Emergency lighting units EM powerled

BERNSTEIN Double Insulated Position Switch I49

Displacement Measuring System for Cylinder Series OSP-P

Pulse Counters, electromechanical

4-in-1 Motor Controller CAN

ATEX UHF RFID Long Range Reader with Integrated Antenna Zone 2 / 22 ISO

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Kuhnke Technical Data. Contact Details

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Datasheet - SRB-E-201ST

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

LONWORKS Fibre Optic Converter

FLEXIBLE SERIES DA LR WW LENTUS

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Magnetic and Hydraulic-Magnetic Circuit Breaker

Absolute Rotary Encoder E6CP

Electrical connection

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Datasheet - SRB301LC 24VAC/DC

Transcription:

For roller conveyors The approach direction of the data carrier can be both, diagonal as well as longitudinal to the read/write head. Rectangular, 80 x 400 mm, height 25 mm Active face on top Plastic, PBT-GF30-VO /S2503 Connectors Type designation Ident no. 7030234 /S2500 Connectors Remark to product For roller conveyors (vertical or horizontal orientation) Mounting conditions Non-flush, flush mountable Ambient temperature -25 +70 C Operating voltage 19.2 28.8 VDC DC rated operational current ð 230 ma inrush current 1200 ma For: 1 ms Data transfer Inductive coupling Operating frequency 13.56 MHz Radio communication and protocol standards ISO 15693 Read/Write distance max. 345 mm Output function 4-wire, Read/Write Suitable for bus mode to TBEN-*. No /S2501 Connectors Design Dimensions Housing material Active area material Rectangular,Q80L400 400x 80x 25mm Plastic, PBT-GF30-V0, Black Plastic, black Functional principle The HF read/write operating at a frequency of 13.56 MHz form a transmission zone the size of which (0 500 mm) varies, depending on the combination of read/write head and data carrier. The read/write distances mentioned here only represent standard values measured under laboratory conditions. The read/write distances of the data carriers for mounting in metal TW-R**-M(MF) were determined in metal. Attainable distances may vary by up to 30 % due to component tolerances, mounting conditions, ambient conditions and material qualities (especially when mounted in metal) Testing of the application under real operating conditions is therefore essential, especially with read/write on-the-fly! 1 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Electrical connection Connectors, M12 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 121 years acc. to SN 29500 (Ed. 99) 40 C Power-on indication LED,Green/Yellow/Red Diagnostic display Functional description of the orange range-restricted LED: If the read/write head is supplied with voltage, it briefly checks to see whether its resonance frequency is affected by surrounding metal. If this is the case, the resonant circuit off-tunes its frequency to reach again the (optimum) resonance frequency. However, this is only possible within a certain range. If too much metal is in the environment, the read/write head cannot re-tune or the surrounding metal takes too much energy from the field and due to the reduced range the communication the read/ write head and the tag (data carrier) is cut off (the orange range-restricted-led lights up). If the LED is off, this does not mean conversely, that no reduction in range occurs. The lit LED is rather an indication of too much metal in the environment and a greatly reduced range (about 50% less). Packaging unit 1 2 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Data carrier TW-R16-B128 6900501 50 95 74 205 240 TW-R20-B128 6900502 TW-R20-K2 6900505 60 102 86 202 240 15 64 70 195 240 TW-R30-B128 6900503 TW-R30-K2 6900506 90 152 132 217 240 70 122 100 208 240 TW-R50-B128 6900504 TW-R50-K2 6900507 150 256 230 242 240 120 216 190 233 240 TW-L49-46-F-B128 7030390 74 176 149 197 240 3 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Data carrier TW-L80-50-P-B128 7030389 136 229 204 207 240 TW-R80-M-B128 7030207 TW-R80-M-K2 7030205 40 77 56 199 240 30 77 64 195 240 TW-L86-54-C-B128 6900479 200 345 306 242 240 TW-L18-18-F-B128 7030634 60 128 116 58 240 4 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Data carrier longitudinal approach TW-R16-B128 6900501 30 95 410 37 240 TW-R20-B128 6900502 TW-R20-K2 6900505 40 102 404 43 240 30 64 390 35 240 TW-R30-B128 6900503 TW-R30-K2 6900506 60 152 434 66 240 50 122 416 50 240 TW-R50-B128 6900504 TW-R50-K2 6900507 100 256 484 115 240 90 216 466 95 240 TW-R50-90-HT-B128 1542326 TW-R50-90-HT-K2 1542329 70 226 484 115 240 60 186 466 95 240 5 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Data carrier longitudinal approach TW-I14-B128 6900526 30 95 410 37 240 TW-L49-46-F-B128 7030390 68 176 394 74 240 TW-L80-50-P-B128 7030389 85 229 414 102 240 TW-R80-M-B128 7030207 TW-R80-M-K2 7030205 30 77 398 28 240 30 68 390 32 240 TW-R4-22-B128 7030237 20 80 368 34 240 6 / 7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com