Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd.

Similar documents
Multi Room Audio Matrix Switcher

Multi Room Audio System

Aspect 2 Circuit Digital Scene Control

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Multi Room Audio Matrix Switcher and System /2E /2 User s Guide

Dimming actuators GDA-4K KNX GDA-8K KNX

SceneStyle2 User Guide

Product Manual. Designed and Manufactured in the UK by Optikinetics

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Automatic Transfer Switch Control PLC Operator s Manual

MAX T200 HD QUICK INSTALLATION GUIDE

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

MONOPRICE. 27" UHD IPS 4K Ultra Slim Aluminum Monitor. Quick User's Guide P/N 24658

STX Stairs lighting controller.

KNX Dimmer RGBW - User Manual

ZoneTouch V2 Zone Control System User Manual

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Safety Precautions and Maintenance

Weighing Scale. 10key&12key User manual

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

17" & 19" Color TFT LCD Monitor

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

KONTROL channels DMX controller USER MANUAL. For safety, please read this user manual carefully before initial use.

I.Safety Prevention Measures

User interface. Abbreviations / Meanings

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

CP-255ID Multi-Format to DVI Scaler

Table of Contents Safety Precautions 1.1 Safety Precautions... Introduction to the Product 2.1 Features Important Information

WS-6002U Atomic Clock. Instruction Manual

Product Identification

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

StarServe Accessories 8001/4EX, 8000INJ, 8000AVB, 8000DCB. Installation Information

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Live events staging. Media centers

SPA MICROPROCESSOR SPEEDOMETER INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...

Operations of ewelink APP

Operating Manual. Basic Control BC16. two-channel for eco moon

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

REMOTE DISPLAY WIRELESS DECODER MK II

P XGA TFT Monitor. User s Manual

ASSEMBLY AND CALIBRATION

VITEK VTM-TLM191 VTM-TLM240

Chapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

ET BLU MIX RX-Condo-3

TRUCOLOUR. 8x8 Modular Matrix INSTALLATION GUIDE

H270 LED MONITOR USER MANUAL

ST9100C User Guide. Features

PXL2760MW LED LCD Monitor

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

P Triply ingenious Portier

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

CITIZEN QUARTZ CHRONO MEMO. Model No. JM8XXX Cal. No. C220 INSTRUCTION MANUAL CTZ-6756

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

16 Stage Bi-Directional LED Sequencer

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

User s Manual. Digital Switch Part #: DL-HDS21 Part #: DL-HDS41

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

Calibrating and Profiling Your Monitor

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

DMX512 Digital Dimmer Operator Manual

Instruction Manual for Programmable Digital Timer

DFT-709. Operation Instructions. LCD Color TV Receiver

SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 CUSTOMER SERVICE... 4 PACKAGE CONTENTS... 4 RECOMMENDED TOOLS... 6 CONTROL PANEL OVERVIEW...

APOLO DC B Electric Thermal Radiators

Operating Instructions

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Instruction manual. DALI Gateway art Installation manual

DIAMOND DIGITAL DV197/DV197SB

Owner's Manual. TOUCH SCREEN CONTROLLER for Air Conditioning Control System. Model BMS-CT5120UL. English

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

Installation & Programming Manual. Please read before using this timer.

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

22" Touchscreen LED Monitor USER'S GUIDE

Tech Support: Customer Service: General Tech Questions: Tech Docs:

VF-STB IP Appliance User Guide

Defrost Control Installation and Programming of Version 3.1 Cards


Video Wall Display User s Manual

OPERATION AND MAINTENANCE

PXL2470MW LED LCD Monitor

American DJ. Show Designer. Software Revision 2.08

Operating Instructions BTX-1 Series Digital Band Tension Meter

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Transcription:

Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd. Neo is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Clipsal Australia Pty Ltd. The information in this manual is provided in good faith. Whilst Clipsal Australia Pty Ltd (CAPL) has endeavoured to ensure the relevance and accuracy of the information, it assumes no responsibility for any loss incurred as a result of its use. CAPL does not warrant that the information is fit for any particular purpose, nor does it endorse its use in applications that are critical to the health or life of any human being. CAPL reserves the right to update the information at any time without notice.

Contents 1.0 Product Range 5 2.0 Description 5 3.0 Care Instructions 6 4.0 Definitions 6 5.0 Basic Operation 7 6.0 Setting the Time 9 7.0 Learn Mode 10 7.1 Creating a Group 11 7.2 Using Timers 12 8.0 Scenes 13 8.1 Creating a Scene Control 13 8.2 Recording a Scene 14 9.0 Specifications 15 10.0 Limited Warranty 15 3

4

1.0 Product Range This user s guide describes the following A Series DLT 5-button wall switches with rectangular plates: Catalogue Number 5055DL 5085DL Description C-Bus A Series DLT Wall Switch, Neo style C-Bus A Series DLT Wall Switch, Saturn style Several fascia styles for A Series DLT can be ordered. Consult the current catalogue or contact your local Clipsal sales representative. 2.0 Description C-Bus A Series Neo and Saturn DLT input units are a range of high end C-Bus switches with Dynamic Labelling Technology (DLT). Units feature 5 physical buttons that control up to 8 control groups. The LCD interface displays labels and status information for each button/control group. Units have scene management and learn mode capability. Labels can consist of text (in several languages) or graphics. To reflect a change in functionality, you can change them dynamically using other C-Bus devices, such as the C-Bus Multiroom Audio System. Learn mode enables you to create associations between buttons on input units such as the DLT, and loads on output units such as dimmers. It allows you to add functionality such as timers and scenes. Scene capability allows you to perform a series of actions across multiple outputs by pressing a single button. For example, on arrival home you could use a scene to switch on lights in the hallway and kitchen, dim lights in the lounge, and switch on a heater. Using special software, C-Bus DLT units can be programmed so their controls can be enabled and disabled (locked) from another C-Bus unit. 5

3.0 Care Instructions The C-Bus DLT units contain electrical and electronic parts. Be sure to follow these precautions: The C-Bus DLT range is designed for indoor use only. Do not use hard, sharp objects to select the controls. Do not use spray cleaners or chemicals to clean the DLT unit. Use only a soft cloth for cleaning. no wet hands no cleaner spray no coverage no direct sunshine no dust 4.0 Definitions Term load scene learn mode quick-press double quick-press Definition An electrical device connected to mains voltage via a C-Bus output unit. Examples include lights, AC power points, heaters and electric motors. A series of actions across multiple outputs, triggered by a single button. For example, on arrival home you could use a scene to switch on lights in the hallway and kitchen, dim lights in the lounge, and switch on a heater. A configuration state of a network that contains C-Bus2 units. Learn mode enables you to create associations between buttons on input units such as the DLT, and loads on output units such as dimmers. It allows you to add functionality such as timers and scenes. A brief button press (pressed for a fraction of a second). Two quick-presses in quick succession. 6

5.0 Basic Operation A C-Bus A Series Neo or Saturn DLT input unit has 5 buttons which control up to 8 control groups. The upper 4 buttons operate the control groups on the active page. The fifth button alternates between pages (two pages of up to 4 control groups each) and is used to set the time and date. This is illustrated in Figure 1. Figure 1. An A Series DLT unit has two pages, each with four control groups The DLT interface consists of an LCD display that provides information and feedback about the groups the unit controls. This includes: a label for each control group a bar below each label indicating the control type and level (such as a SCENE or dimmer slider) the current page number the time (if enabled). Some interface examples are provided in Figure 2, together with descriptions. Normally, special software is used to configure a C-Bus DLT unit when it is installed. This configuration tells the unit which button controls what. It is also possible to configure the unit using learn mode, which is described in section 6.0. 7

Figure 2. Identification of the DLT interface 8

6.0 Setting the Time C-Bus DLT input units contain a clock. The time is displayed at the base of the display when the clock is enabled and the time has been set. You can set the time from the DLT unit, or from certain other control units such as the C-Bus Colour Touch Screen. Setting the time on a DLT enables the clock on that unit. It also sets the time on other C-Bus units that have their clocks enabled and reside on the same C-Bus network. Figure illustrates how to set the time on a DLT unit: 1) Hold down the fifth (bottom-most) button for 10 seconds, until the display changes to time set mode. 2) Adjust the time. Press the Select (top) button to select which time property to adjust (hour or minute). The + and (second and third) buttons increment and decrement the selected time property. Note that the time is displayed in 24-hour format, where 14:00 is equivalent to 2:00 pm. 3) Press the OK (bottom-most) button to exit clock set mode. Figure 3. Setting the time You will need to set the time again after a power failure. This may not be necessary if a control unit capable of restoring the time is present on the C-Bus network (such as the C-Bus Colour Touch Screen). 9

7.0 Learn Mode A C-Bus network consists of various C-Bus units that are connected together. Some of these are input units such as wall switch buttons or infrared sensors that send messages over the network. Others are output units that control lights and other devices in response to messages they receive over the network. In a C-Bus network, associations are created between input and output units. These associations are called groups. A group typically associates one or more buttons on a switch (input) unit, with one or more channels on a dimmer or relay (output) unit. (Most output units can control multiple loads, each of which is referred to as a channel). The example in Figure 4 shows two groups that could exist in a C-Bus network. Button 1 of the Neo is grouped with channel 2 of the Relay unit. Button 2 of the Neo is grouped with the PIR and channel 1 of the Relay. Figure 4. A typical C-Bus network 10

Groups can be created between C-Bus2 units using learn mode. To enter learn mode, press and hold a button on a C-Bus2 output unit for 10 seconds. When in learn mode, you can perform the following functions on a C-Bus DLT unit: group a single DLT control group with inputs and outputs on other units group a pair of DLT controls with inputs and outputs on other units include a timer function in a control group (single or pair) create a scene control 7.1 Creating a Group The example in Figure 5 shows the creation of a group which includes channel 3 of a dimmer (output) unit, control group 2 of a DLT (input) unit, and button 2 of a standard Saturn (input) unit. The result is that the light or other appliance connected to channel 3 of the dimmer, can be controlled from both the DLT and standard Saturn unit. Figure 5. Creating a group including a dimmer, DLT and Saturn unit To group a DLT control group with a C-Bus2 output or other inputs: 1) Go to the output unit you want the DLT unit to control. 2) Hold down the button corresponding with the channel you want to control for 10 seconds. The Unit and C-Bus indicators will flash alternately, the selected output channel will switch on, and all other C-Bus outputs in the same network will switch off. 3) Select the control group on the DLT unit that you want to include in the group. Use the buttons to select and deselect control groups. Press the fifth button to alternate between pages 1 and 2. The Toggle/Dimmer function is assigned when you select a single control group. If you select two control groups on the same unit, 11

the first one you select uses the On+Up and the second uses the Off+Down function. This allows a pair of buttons to control a group; one to switch on/dim up, the other to switch off/dim down. 4) Select any additional input unit buttons or output unit channels you want to include in the group. 5) Press and hold a button on a C-Bus2 output unit for 1 second, to exit learn mode. 7.2 Using Timers When using learn mode to create a group, you can set a control group to work as a timer. You do this by holding a button down when selecting a control group (instead of using a quick press). The display will identify the function as Timer and show the timer period (see Figure ). As you continue to hold, the period increases until you release the button. The timer period can be set to 5 seconds, or from 5 minutes to 10 hours and 35 minutes (in 5 minute intervals). Figure 6. Creating a timer 12

8.0 Scenes A scene allows you to perform a series of actions across multiple outputs by pressing a button. For example, on arrival home you could use a scene to switch on lights in the hallway and kitchen, dim lights in the lounge, and switch on a heater. A C-Bus DLT unit can have up to eight scenes, depending on how many groups they control. Up to four scenes may be created using learn mode, any additional scenes must be programmed using special software. Scenes may control up to 40 groups in total, with up to 10 groups per scene. There are two stages of creating a scene: 1) You must create a scene control group. This is used to trigger the scene. Any of the eight DLT control groups can be used as a scene control. 2) You must record the scene. This involves setting states of the buttons you want to be recalled, and assigning these to the scene control. 8.1 Creating a Scene Control A scene control is created by double quick-pressing a DLT button in learn mode: 1) Activate learn mode by holding down a button on a C-Bus2 output unit for 10 seconds. The Unit and C-Bus indicators will flash alternately, the selected output channel will switch on, and all other C-Bus outputs in the same network will switch off. 2) Quick-press the same button again to switch it off. 3) Double quick-press one of the first four buttons on the DLT. The SCENE function type will display, together with the control group numbers that are set as scene controls. 4) Press the DLT buttons to select and deselect which control groups you want to use as scene controls. 5) Press and hold a button on a C-Bus2 output unit for 1 second, to exit learn mode. 13

Figure 7. Creating a scene control 8.2 Recording a Scene Once a scene control has been created, you can use it to capture the states of lights and other devices connected to the C-Bus network. These states can then be recalled using the scene control. The following steps are illustrated in Figure. To capture the states of lights and other appliances (record a scene): 1) On the DLT unit, press and hold the button that corresponds with the scene control for 10 seconds (until the word RECORDING is displayed). 2) Set the states of the lighting levels and other electrical appliances that you want to capture as part of the scene. On any C-Bus2 switches in the network, you can switch buttons on, or set them to a specific level (in the case of dimmers). To capture an off state, switch a button on and then off. 3) Press and hold the scene control button for 1 second (until the word RECORDING changes to SCENE). This exits scene record mode. Figure 8. Recording a scene 14

9.0 Specifications Parameter Status indicators Backlight Warm-up time Description Blue, one indicator per button (dimmable) White, user configurable (dimmable) 5 seconds Operating temperature range 0 to 45 C Operating humidity range 10 to 95% RH Refer to the Installation Instructions for more detailed specifications. 10.0 Limited Warranty C-Bus A Series DLT products carry a two-year warranty against manufacturing defects (refer to Warranty Statement). 15