Protocol for a Cell Proliferation Assay Using the µ-slide Angiogenesis

Similar documents
ALVEOLE Révision 3. PRIMO Protocol for Protein Patterning. CONFIDENTIEL page 1/10

5. Drain off excess 1X PBS (gently blot PBS off underside of coverslip after draining) and transfer slides/coverslips to humid chamber.

LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

1 PROTOCOL FOR FLUORESCENCE IMAGING SYSTEM. General Switch (1), (2) DG4 Lamp switch (3) DG4 Main Switch (4) LAMBDA 10-2 (5) Camera (6) Computer (7)

In Situ Hybridization Protocol Cryosections

Countess II and Countess II FL Automated Cell Counters

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

USER GUIDE. for. Automated purification of DNA from cells or tissue samples with

Embryo In-Situ. 5) Transfer to fix in scintillation vial for 40 minutes (8ml First fix + 8ml heptane)

Robarts Research Institute at the Western University London, Ontario, Canada

Countess II FL Automated Cell Counter

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

USER GUIDE. for. Automated purification of DNA from Plant leaves and seeds with

AUTOMATIC COVERSLIPPER CVR909. Date of issue: 21/03/2019 Rev. 04

RIDA GENE Color Compensation Kit I

Tali Image-Based Cytometer

Sofia Strep A FIA Page 1 of 5

ab FirePlex Immunoassay Human Key Cytokines 17-plex Protocol Booklet

USER GUIDE. for. Automated purification of DNA from human or animal blood samples with

Fragment Analyzer CRISPR Discovery Gel Kit

Colorimeters and UV/Visible Spectrophotometers. from

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2.

4.1 PRESSURE ADJUSTMENT Adjustment of Pressure Detector Circuit Adjustment of Pressure Indication...2

Checking the fluids of the cart

Fragment Analyzer Genomic DNA Analysis Kit

SediVue Dx * Urine Sediment Analyzer User Guide

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

bio bas.1 USER S MANUAL

SECTOR Imager Performance Qualification Kit

bio bas. 2 USER S MANUAL

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

Fragment Analyzer SS NGS, HS NGS & RNA Analysis Kits

FLUXION BIOSCIENCES INC.

Standard Operating Procedure Aria III - Irchel

The world s fastest Spiral plater. easyspiral N

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

Fragment Analyzer Genomic DNA Analysis Kit

Digital PCR Analysis Software version 3

Personal Protective Equipment Wear nitrile gloves, lab coat, and safety glasses as a minimum protection, unless otherwise indicated.

XPert Filtered Balance Systems

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

CA-50 OPERATOR S MANUAL SYSMEX CORPORATION KOBE, JAPAN. Automated Blood Coagulation Analyzer

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

APPENDIX I. Detailed procedure for estimation of purine derivatives : Determination of allantoin by a colorimetric method

easyspiral The world's fastest Spiral plater

Enantioselective Synthesis of ( )-Jiadifenin, a Potent Neurotrophic Modulator

Imagine... continuous rapid processing maximizing productivity. Tissue-Tek Xpress x Series. Continuous Rapid Tissue Processor

PM2500 Size: 250 µl x 2 5 µl per well for 100 applications

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

MULTI STANDARD CAMERA SYSTEM

All Blue Regular Range Plus Protein Marker (9-180 kda) PM1600 Size: 250 µl 2 5 µl per well for 100 applications

Lesson 12. Advanced Digital Integrated Circuits Flip-Flops, Counters, Decoders, Displays

Flip-Flops and Registers

STUDENT HANDOUT Modeling a microvascular network with tubing

MR.SPOT Processor REF User Manual

Hettich Cyto System The full range

MEDICAL DEVICES. CompoDock STERILE PVC TUBE CONNECTIONS IN JUST TWO STEPS

PAL LSI - Robust and Reliable Sample Handling

Total Chlorine Sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

Release Notes for LAS AF version 1.8.0

Hettich Cyto System The full range

multichannel systems* User Manual QT

NimbleGen Arrays User s Guide. CGH Analysis. For life science research only.

Method Number: SOP Number: Revision Number: SOP Date: Personnel records observed:

MR.SPOT Processor REF User Manual

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Caring for Sacramental Records

SUMMARY OF THE METHOD SAMPLE PREPARATION

Model ED 23 Drying and heating chambers Classic.Line with natural convection

IKA Analytical line Calorimeters C 2000

Scout 2.0 Software. Introductory Training

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

Microbiology Practical Exam

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Operation of the ACEA NovoCyte Flow Cytometer

SmartMix Manual V5350A

MOXI Flow TM USER GUIDE. For Research Use Only. Moxi Flow is not for use in diagnostic procedures.

COLORBLAST 12 POWERCORE

Instruction manual. KUZMA 4POINT 14 inch TONEARM Serial Number:

FACSAria I Standard Operation Protocol Basic Operation

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ECE 331 Digital System Design

85.1% Mystery Shop Report # Greenwood Premiere Cinema Bypass Hwy 72 Greenwood, SC Saturday July :23PM.

ECE 301 Digital Electronics

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM

CyFlow Space Your flexible flow cytometer

Slide 1. Conservation Update. Robert Hooke s Micrographia London:1667. Eliza Gilligan, Conservator for UVa Library

MR.SPOT Processor REF User Manual

LCD MODULE DEM B SYH

Data Collection at SSRL: practical aspects

Design of NIR Chromenylium-Cyanine Fluorophore Library for Switch-ON and Ratiometric Detection of Bio-Active Species in Vivo

COSC3213W04 Exercise Set 2 - Solutions

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Introduction to the FTA2000

Volume 76 June Journal of CELL SCIENCE. The Company of Biologists Ltd

[source unknown] Cornell CS465 Fall 2004 Lecture Steve Marschner 1

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

Radiation Protection Aprons

Transcription:

Protocol for a Cell Proliferation Assay Using the µ-slide Angiogenesis 1. General Information... 1 2. Background... 1 3. Material and Equipment Needed... 2 4. Experimental Procedure... 2 a. Seeding Cells... 2 b. Fixation of the Cells in a µ-slide Angiogenesis... 3 c. Staining of the Cells in a µ-slide Angiogenesis... 3 5. Image Capture of the Wells... 3 6. Data Analysis... 4 7. Results... 5 1. General Information This protocol describes a cost-efficient technique for analyzing cell proliferation. The example used in this application note is the analysis of the growth rate of MDCK cells in a µ-slide Angiogenesis, which is shown below. 2. Background The µ-slide Angiogenesis contains a total of 15 wells, as shown in Figure 1. Each well is divided in two parts, an upper well and an inner well. The upper well has a volume of 50 µl and the inner well has a volume of 10 µl, which adds up to a total volume of 60 µl per well. The principle of this cell proliferation assay is that one µ-slide Angiogenesis will represent the growth of the cells in one day. For this reason, use one µ-slide Angiogenesis for each day of your experiment. On each day, the cells of one slide will be fixed to stop cell growth. At the end of the Figure 1: Geometry of a µ-slide Angiogenesis (ibidi ). experiment, the µ-slides from all days will be stained with DAPI and images of the wells will be captured with a fluorescence microscope. These images will then be stitched together using ImageJ or FIJI, and the cells in each well will be counted. Finally, a diagram will be created, that will show the growth rate of the cells. ibidi, Version 1.0, March 16th, 2016 Page 1 of 6

3. Material and Equipment Needed The following reagents and materials are needed for the given protocol: Table 1: Material and reagents needed for the cell proliferation assay. Name Concentration for experiment Company Order No. Cells/Material MDCK cells 1x 10 4 cells/ml Commercially available - Reagents µ-slide Angiogenesis, ibitreat DMEM - ibidi 81506 1x FBS/FCS 10% PBS Formalin solution, neutral buffered, 10% 1x 10% formalin (approx. 4% formaldehyde) D5796 F0804 D8537 HT50-1-1 DAPI 0.2 µg/ml Carl Roth 6335.1 Mounting Medium - ibidi 50001 The following equipment and instruments are necessary for the given protocol: Cell culture incubator (high humidity, 37 C, 5% CO2) Fluorescence microscope equipped with a DAPI filter set 4. Experimental Procedure a. Seeding Cells The first day of the experiment: 1. Prepare a cell suspension (1x 10 4 cells/ml) in DMEM containing 10% FCS. 2. Seed 10 µl of the prepared cell suspension into each inner well (100 cells per well) of all µ-slides Angiogenesis (prepare one µ-slide Angiogenesis for each day of the experiment). 3. Place the slides into humidifying chambers (petri dish with a wet sterile tissue, see Figure 2) and incubate them at 37 C until the cells have attached 4. Add 50 µl of growth medium to each well and incubate the slides at 37 C (slide 1 for 24 hours, slide 2 for 48 hours, slide 3 for 72 hours, etc.). Figure 2: Humid chamber. ibidi, Version 1.0, March 16th, 2016 Page 2 of 6

b. Fixation of the Cells in a µ-slide Angiogenesis Note: Make a fixation of only one µ-slide Angiogenesis per day! The pipette should only touch the upper well (see Figure 3)! Figure 3: Using the pipette in one well of the µ-slide Angiogenesis. The following days of the experiment: 5. Remove 50 µl of medium from each well of the µ-slide Angiogenesis. 6. Wash the cells twice with 50 µl of 1x PBS per well, and remove the 1x PBS again. 7. Apply 30 µl of Formalin 10% (contains 4% Formaldehyd) to each well, incubate for 5 minutes, and then remove Formalin. 8. Wash the cells twice with 50 µl of 1x PBS per well, and remove 1x PBS again. 9. Apply 50 µl of PBS to each well and store the µ-slide Angiogenesis at 4 C. c. Staining of the Cells in a µ-slide Angiogenesis The last day of the experiment: 10. Prepare a 1:5 dilution of 1 µg/ml DAPI in 1x PBS (e.g., for one µ-slide Angiogenesis prepare 180 µl of 1µg/ml DAPI + 720 µl of 1x PBS). 11. Remove the 1x PBS from each well. Do not let the well dry out after aspirating the liquid! 12. Apply 50 µl of the DAPI mixture to the wells of every µ-slide Angiogenesis. 13. Incubate for 1 hour at 4 C. 14. Remove the DAPI mixture and apply 50 µl of Mounting Medium. 5. Image Capture of the Wells If the microscope software you are using does not have an automatic image-stitching tool, you can also manually stitch several single images together, as described in this chapter. Note: Find out how many images you need to capture with the respective camera of your microscope to give you an overall picture of one well. Observe the cells under a fluorescence microscope (e.g., Nikon Eclipse Ti-E) with the appropriate filter sets for a DAPI-staining. With the camera used for this protocol, nine images must be captured to create an overall picture of one well. Make sure that the images are overlapped. It is useful to save the images as well xy (Figure 4). ibidi, Version 1.0, March 16th, 2016 Page 3 of 6

Figure 4: Images of the parts of one well and naming suggestions. 6. Data Analysis The single images can be stitched together with the software ImageJ or Fiji, in order to create one big image for each well. The Fiji software is just ImageJ, with many useful plugins included. Download ImageJ here: http://rsb.info.nih.gov/ij/, and Fiji here: http://fiji.sc/downloads. Install Fiji or ImageJ and the Stitching Plugin. Choose: Plugins Stitching Pairwise stitching (two images are stitched into one). Repeat stitching for all images. ibidi, Version 1.0, March 16th, 2016 Page 4 of 6

Another plugin that can be used is MosaicJ: Install Fiji or ImageJ and the Stitching Plugin. Choose: Plugins Stitching MosaicJ. Go to File Open Image Sequence of all nine images, and then arrange them until the whole well is shown in one image. Go to File Create Mosaic. 7. Results Figure 5 shows the stitched-together pictures. Each picture represents one well at four different time points. These images show how the cells grow within 96 hours. Figure 5: Image of one well of each µ-slide Angiogenesis. a) One well of the µ-slide fixed after 24 hours, b) one well of the µ-slide fixed after 48 hours, c) one well of the µ-slide fixed after 72 hours, and d) one well of the µ-slide fixed after 96 hours. Now these cells can be counted with ImageJ. Install the Cell Counter plugin for ImageJ. Choose: Plugins Analyze Cell Counter. Count the cells manually. The Results window will show your total cell number and can be transferred to an excel file, as shown in Table 2. ibidi, Version 1.0, March 16th, 2016 Page 5 of 6

c e ll n u m b e r Table 2: Results of the Cell Counter for total cell numbers. hours well 24 48 72 96 1 188 371 815 2054 2 181 367 703 1971 3 113 257 803 1735 4 145 297 1047 1830 5 212 358 801 1971 6 209 434 1183 2539 7 247 536 830 1933 8 121 336 1095 2435 9 241 509 861 2595 10 251 502 1156 1992 11 142 351 902 2031 12 167 339 906 1899 13 131 362 1021 2302 14 231 405 798 1997 15 103 393 897 2135 Mean 178.8 387.8 921.2 2094.6 StdDev 51.3 78.5 145.2 257.5 A chart will be created with the values from Table 2 that will show the growth rate of the MDCK cells (Figure 6). Figure 6 confirms that the cell number of MDCK cells continuously increases. 2 5 0 0 2 0 0 0 1 5 0 0 1 0 0 0 5 0 0 0 0 2 4 4 8 7 2 9 6 h o u r s Figure 6: Cell proliferation of MDCK cells. ibidi, Version 1.0, March 16th, 2016 Page 6 of 6