MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Similar documents
Single mode 9/125µm, duplex

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Perle Fast Ethernet Media Converters

Perle Fast Ethernet Media Converters

Ethernet Media Converters

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

LONWORKS Fibre Optic Converter

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Fibre Optic Modem ODW-622

Job Aid Server and CSS Separation Avaya S8700 Media Server

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Fibre Optic Modem ODW-611

IES-3162GC. >> Industrial 18-port Managed Ethernet Switch with 16x10/100Base-T(X) Ports and 2xGigabit combo ports. Industrial Ethernet Switch

Fibre optic router for TP/FT-10 LRW-112PP

FOM-9010, FOM-9011 and FOM-9012

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

LONWORKS Fibre Optic Router

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Fibre Channel Fiber-to-Fiber Media Converters

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

4 Channel Video and IP Over Fiber Extender Kit with RS485 Data. User Manual L-4VID-1IP-FE-TX-RX

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

ODW-621. RS-232 Point-to-point applications

opengear OPG-1L 50 MHz-2.3 GHz

Option TELCO / RJ-45 The converter is available either with twelve RJ45 jacks or one TELCO connector on the 10Base-T side.

OTX Optical Transmitter. Operation Instructions

The Art of Engineering

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

E3/DS3 Fibre Extender

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

2015 OPTICAL TRANSMITTERS

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

FiberLink 3350 Series

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Product Operation Manual

OptEnet OC48 Regenerator Module User Manual

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.

application software

EDS-G205-1GTXSFP/G308 Series

VGA to DVI Extender over Fiber SET

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

ADX-2400N AUDIO DISTRIBUTION AND DELAY SYSTEM. (Analog I/O)

TC3301. User's Manual

application software

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Tebis application software

FiberLink 3500 Series Transceivers

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

L-Band Fiber Optic Links

Ordering Information. Industrial Ethernet Solutions

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

EDS-210A Series. 8+2G/9+1G-port Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Mustang Series Fast Ethernet, TFOCA II, 100Base- TX / FX Media Converter, Multimode, 1310nM, USB Powered - 5.0VDC

PRODUCT NUMBER: TMS-E1EH8-X61xx. Specification. 48Gbit/s Mini SAS HD. Active Optical Cable. Ordering Information

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

DA E: Series of Narrowband or Wideband Distribution Amplifiers

THE ART OF ENGINEERING

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

MediaCento IPX 4K. Product Data Sheet VX-HDMI-4KIP-TX VX-HDMI-4KIP-RX. Overview. Basic Features blackbox.com

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

Features. CPU Version. Non-CPU Version

Fiber Converters TFC-110 Series. ŸQuick Installation Guide (1)

User s Guide CSETF10xx-205 Slide-in-Module Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

Long Distance L-Band Fiber Optic Links

Typical applications:

ED5229GT-E Series. Page 1 of 8

Fiber Converters TFC-1000 Series. ŸQuick Installation Guide (1) ŸTechical Specifications (4)

PURE NETWORKING MEDIA CONVERTERS

twister Mbps TX-to-FX Media Converter

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Agilis Fiber Optic Transceiver AFOT Series

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

5100 Series IF Fiber Optic Links

Instruction Manual Model Block Up/Downconverter

SAT IF distribution system

Proposal of Distributing 4 SAT IF Signals To 209 Homes within 3Km Over Fiber Cable

PROFESSIONAL DWDM OPTICAL LASER TRANSMITTER for HFC & FTTH LARGE CATV & SAT MHz DISTRIBUTIONS

I N S T R U C T I O N D A T A

Installation. Step 1 Carefully unpack the package contents.

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

COE Group plc. Contents

VS-TV. User manual. Virtual Matrix ENGLISH

Arista 40G Cabling and Transceivers: Q&A

TC3005(LED/ELED/LASER) User's Manual

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

HDO701 FIBRE OPTIC TRANSMITTER

Transcription:

Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection of redundand datanetworks (Industrial Ring Networks) to a central point using 19 technology. The Switch Module can be integrated into a redundant Industrial Ring and be used as uplink to the core switch of the entire enterprise LAN. A further application is the connection of end devices in the office environment to the 10/100TX ports for an uplink via fiber optic. The interconnecteion with the redundant fiber optic ring will be realized by using two Switch Modules which have to be connected via a 10/100Base-TX connection. With this new Switch Module the procedure for fault tolerant Fiber Optic Rings patented by is extended to the medium copper on the ring side. If the two Switch Modules will be installed in two separate 19 racks at different locations it is possible to integrate it into an over placed redundant architecture of the central switch via separated data paths. The integrated SNMP Management Agent allows the central monitoring, configuration and administration of the entire ring network. This Switch Module offers an extendes Management including VLAN support and dataprioritisation (QoS) according to IEEE802.1p/Q. The integration into a central Management System is possible. Beside the SNMPfunctionality also further NMS standards e. g. Telnet and the proprietary Device Manager are supported. Features Fast Ethernet 5 Port Switch, 4x 10/100Base-TX, 1x 100Base-FX Redundant Ring Functionality also via copper (TP) possible Compatible to Industrial Switches with Ring Redundancy Reconfiguration in < 100 ms Central Power Supply with Redundancy Option (110-230 V AC or 48 V DC) Integrated Agent for Network Management via PC-Tool, Web, SNMP or Telnet Interface Full VLAN Support / Dataprioritisation according to IEEE_802.1q Galvanic separated Alarm Contact (Relay Contact) Full compatible to all Modules of the NICROSENS Access Series

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 2/10 Technical Data Type Ports Manageable Fast Ethernet Switch (Rack module) with 4 x 10/100Base-TX and 1 x 100Base-FX ports for fault tolerant Fiber Optical Rings 4x 10/100/100Base-TX Shielded Twisted Pair Cable, 100 Ohm, Category 5e 1x 100BaseFX Max. Cable length Optical Fiber Type Datarate 100 m (Twisted-Pair) Multimode fiber 50 oder 62,5/125 µm, duplex with ST or SC connectors optional 9/125 µm Single Mode fiber TX ports: 10/100 Mbps (Autonegotiation) FX port : 100 Mbps (fullduplex mode configurable) LED indicators PWR Module active ALARM Link lost Twisted Pair connection o.k. Connection in fullduplex mode Alarm contact Power Supply Galvanic isolated, max. 60 V DC, max. 0,5 A 12 V DC / max. 500 ma via the backplane Operating temperature 0 C to 55 C Storage temperature -20 C to 80 C Dimensions 128 mm x 31 mm Management - Statusinformation via web based Management (http server, standard) - Optional support of SNMPv1 (Firmware) - Optional support of Telnet (Firmware) - Configuration via PC-based managementtool (has to be ordered seperately) Ring Function For Master and Slavemode, no limitation for the number of modules in the ring, no time out

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 3/10 Optical Parameters Mulitmode versions min. distance * : 2 km (fullduplex) min. opt. power: -19 dbm min. sensitivity: -31 dbm wavelength: 1310 nm connectors: ST or SC duplex Single Mode versions min. distance * : 15 km (fullduplex) min. opt. power: -15 dbm min. sensitivity: -31 dbm max. input level ** : -7 dbm wavelength: 1310 nm connectors: ST or SC duplex min. distance * : min. opt. power: min. sensitivity: max. input level ** : wavelength: connectors: 40 km (fullduplex) -5 dbm -34 dbm 0 dbm 1310 nm ST or SC duplex min. distance * : min. opt. power: min. sensitivity: max. input level ** : wavelength: connectors: 80 km (fullduplex) -5 dbm -34 dbm 0 dbm 1550 nm SC duplex min. Distance * : min. Opt. power: min. sensitivity: max. Receiving level ** : wavelength: connectors: 125 km (fullduplex) 0 dbm -37 dbm 0 dbm 1550 nm SC duplex *The mentioned distances are recommendations, which are guaranteed during the duration of life. The distances are depending on the condition of the transmission line and can vary depending on the quality of the used fibers, connectors and other parameters. Decesive are the listed transmitter and receiver figures. Longer distances than above mentioned can be reached easily. **Furthermore the max. input level of the receiver has to be considered. Especially because the mentioned power values are guaranteed figures, which could be exceeded by 5-7 db. If the max.receiving level of the optical receiver is exceeded for a longer time it could be damaged unrepairable.. Further it is recommended not to use the versions with different optical parameters mixed together e.g. a 15 km version not together with a 40 km version). A proper function cannot be guaranteed in this case.

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 4/10 System Components LED-displays 4x 10/100Base-TX connectors Reset 1 2 3 4 PR Tx Rx 5 Alarm Fast Ethernet Switch Relay Contact 100Base-FX Fig. 1: Indicators and connectors Configuration possibilities The Switch Module has been designed for installation in one of the chassis (19 rack or standalone). It can be installed together with other modules of the Access product group in the same chassis. The power suppy is realized by a central power supply via the backplane of the rack. Max. 12 modules can be installed including the power supply. As an option a second power supply can be installed for power redundancy. In This case only 10 switch or converter modules can be equipped. In case of partial equipment of the rack, the unused slots have to be covered with so called blind plates for EMC and air flow reasons. 3HU chassis MS416001M Power supply MS416004M (redundant) Twin module 100Base-TX/FX manageable MS416230M

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 5/10 Alarm Contact (Relay Contact) A 3 pin alarm contact allows the additional monitoring via external signalling. This contact is switching immediately after the link signal is lost. In case, that the switch module is configured for ring functionality the interruption of the optical link is indicated additionally. In case of power failure the contact is also switched into alarm mode. Reset 1 Relay Contact 2 PR 3 4 Tx 5 Rx closing opening Ground Alarm Fast Ethernet Switch Fig. 2: Pinout Alarm Contact Attention: The max. contact load is 0.5 A /60 V DC. It is not allowed to connect any devices with 230 V AC power supply directly! Management The Management and configuration is possible via an optional powerfull PC software, the Device Manager. Beside the Device Manager use, the status can be checked web based via the integrated http server. Because of security reasons configurations are not possible via the web based management. The switch module can be configured via the Device Manager. With this software the initial configuration of TCP/IP adjustments (IP address, Gateway etc) is possible. Later on these adjustments can be changed always via the Ethernet network. Additionally to the standard firmware for the web based visualisation offers further firmware versions for the support of SNMP and Telnet alternatively. The Device Manager Software is supported of all different firmware versions. All management informations are available in the Ethernet network (Inband Mangement). It is not necessary to connect the agent with a special connection. All TP ports are free for other application. Also the adjustments fort he ring functionality are configured via the Device Manager software. The ring functionality is deactivated in the factory default adjustment. For the configuration of the switch module the rack installed agent is not necessary, but it can be used independently of the integrated management agent.

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 6/10 Reset Button By pushing the reset button (see fig. 3) during operation it is possible to reset the switch manually. During the reset the internal memory of the switch is erased and all connections are initialized new. The settings of the network management are not changed by the reset of the switch. Information such as TCP/IP address, VLAN settings etc. are stored in the permanent memory and are remaining. Reset Button Reset 1 2 3 4 PR Tx Rx 5 Alarm Fast Ethernet Switch Factory Reset Fig. 3: Position Reset Button The reset button has an additional function. By holding this button for approx. 5 sec., the management agent releases an IP request. With the Device Manager and this IP request it is possible to assign the IP address. On the module there is a jumper located. In combination of the reset it is possible to delete the configuration of the switch (VLAN etc.) and to set them back to factory default (Factory Reset). The settings of the network management (e.g. TCP/IP address) are unchanged. Jumper left position: Jumper right position: Factory Reset Normal Reset (default) Ring Configuration The switch module is for the central connetion of fault tolerant ring structures. The patented mechanism is doing a fast reconfiguration of the network in case of a failure. Standarised mechanism like Spanning Tree are not used and supported. For the ring functionality one switch in the ring has the master function, all other switches are simple ring nodes (slaves). This configuration is done via the Device Manager. All switches can be configured as a master or slave switch.

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 7/10 Each switch in the ring is monitoring the status of the direct connected fiber segments. In case of a failure the switch sends a permanent failure signal through the Ethernet to the ring master. Now the ring master closes its logical segment splitting immediately. If the normal operation status is reached again (repair of the faulty connection), this is recognized by the direct connected switches, and the permanent failure signal is stopped. The ring master opens the logical splitting again (normal operation). Fig. 4: Data transmission in normal operation mode (logical interruption of the ring by the ring master) Fig. 5: Data transmission in failure operation mode (the ring master passes the data through) Advantages of the Patent This solution for the fast redundancy offers many advantages: very fast redundancy without delaying mechanism such as Spanning Tree or Rapid Spanning Tree (reconfiguration in less than 100 ms) no special product for the central device of the ring, each switch can be configured as a master switch no rendundancy of the ring master necessary, if the switch with master function fails the logical splitting is remaining at the same position no newtwork load in normal operation mode, the failure signal is only sent in case of a broken connection no limitation in terms of transmit time and the maximum ring size ( fiber connections) no technical limitation of the number of ring nodes (switches)

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 8/10 Ring Configuration Management and configuration are done with a powerful PC software, the Device Manager. Under the menu point Hardware-Settings the modes master and slave can be selected. The switch configured to the master mode is acting as the ring manager and offers the logical segment splitting which avoids the data multiplication. Fig. 5: Hardware Settings With deactivated ring mode (factory default) the switch is working as a normal 5 port switch. According to the Ethernet standard a ring configuration is not allowed then (generating loop, multiplication of broadcast). It is necessary to activate the ring mode before configuring the ring physically. To avoid a correlation between different fiber rings, a ring number (0-255) is assigned via the network management. All switches with the ring feature are having a network management integrated and can recognize and signalize all failures.

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 9/10 Connection (Ring Configuration) The fault tolerant ring is closed with a RJ-45 connection cable using port 4 of the switch module. Because the TP ports are supporting auto crossover, it is not necessary to use a special crossed patch cable. Reset Reset 1 1 2 2 3 4 Close ring via port 4 and TP cable 3 4 Tx Tx PR 5 PR 5 Rx Rx Alarm Alarm Fast Ethernet Switch Fast Ethernet Switch Fiber Ring Fig. 6: Connections Attention: before all connections for the ring are made, it is necessary to configure all switches to the ring mode and at least one switch must be configured as a master! It is not necessary that both modules ar located in the same chassis. According to the standard it is possible to use Cat.5 connections up to 100m.

Fast Ethernet Switch Module 4x 10/100Base-TX, 1x 100Base-FX Page 10/10 Safety Notes WARNING: Infrared radiation as used for data transmission within the fiber optic, although invisible to the human eye, can nevertheless cause damage. To avoid damage to the eyes: never look straight into the output of fiber optic components danger of blinding! cover all unused optical connections with caps. commission the transmission link only after completing all connections. The active laser components used with this product comply with the provisions of Laser Class 1. DANGER: Conductive components of power and telecommunications networks can carry dangerously high voltage. To avoid electric shock: Do not carry out installation or maintenance work during lightning storms. All electric installations must be carried out in accordance with local regulations. Order Information Art.-No. Description Connectors MS415221M MS415222M MS415224M MS415225M Fast Ethernet Switch module 4x10/100Base-TX, 1x100Base-FX 1310 nm Multimode ST, max. 2 km Fast Ethernet Switch module 4x10/100Base-TX, 1x100Base-FX 1310 nm Multimode SC, max. 2 km Fast Ethernet Switch module 4x10/100Base-TX, 1x100Base-FX 1310 nm Single Mode SC, max. 15 km Fast Ethernet Switch module 4x10/100Base-TX, 1x100Base-FX 1310 nm Single Mode ST, max. 15 km 4x RJ-45 2x ST 1x Alarm Contact 4x RJ-45 1x SC duplex 1x Alarm Contact 4x RJ-45 1x SC duplex 1x Alarm Contact 4x RJ-45 2x ST 1x Alarm Contact Further versions on request Accessories Art.-No. MS200150 Description Device Manager PC-Software V3.x, universal Switch-Management reserves the right to make any changes without further notice to any product to improve reliability, function or design. does not assume any liability arising out of the application or use of any product. 1405/He/Ra