MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

Similar documents
MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

MTS/T-BERD 8000 Platform

MTS/T-BERD Platforms WDMPMD Module

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Optical Channel Analyzer

OTS-300 Express Series Power Meters/Sources and Testers

The Art of Engineering

Agilent 81600B Tunable Laser Source Family

Compact EGC Fiber Deep Nodes A90100 and A90300

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

ACION 8000 Series. A8KFR1 1RU Forward Receiver

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Prisma Optical Networks Ancillary Modules

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Light Source. Specification & User Manual

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

PONA 3000 Series Erbium Doped Fiber Amplifier

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

PONA 3000 Series Erbium Doped Fiber Amplifier

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

OPTICAL TEST EQUIPMENT

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

Model GS Port Node 1 GHz with 65/86 MHz split

2015 OPTICAL TRANSMITTERS

Compact live fiber identifier with integrated optical power meter

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

DWDM. DATA SHEET DB4134-E Issue F Page 1 of 6

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Optical Add/Drop Cards

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

LT1550 Laser Transmitter with Erbium Doped Fibre Amplifier

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

CHP Max Headend Optics Platform CHP CORWave II

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

OPTICAL POWER METER WITH SMART DETECTOR HEAD

ASP-FIBRS1 User Manual

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

ED5229GT-E Series. Page 1 of 8

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

HDO701 FIBRE OPTIC TRANSMITTER

HDO750 OPTICAL AMPLIFIER FAMILY

Datasheet: SimpliFiber Pro

Agilent 87075C Multiport Test Set Product Overview

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

OSICS 8-Channel Modular Platform for DWDM Testing

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

HSR-1 Digital Surveillance Recorder Preliminary

JD725A Cable and Antenna Analyzer - Dual Port

OmniStar GX2 Headend Optics Platform

Headend Optics Platform (CH3000)

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

ED5229GT-E/GTRE Series

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

OPTICAL DISTRIBUTION STATION -

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

ST800K-U Optical Power Meter. User Manual V1.0

40G SWDM4 MSA Technical Specifications Optical Specifications

OSA20 KEY FEATURES SPEC SHEET OPTICAL SPECTRUM ANALYZER

Extension kit for R&S Vector Network Analysers

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

The Art of Engineering

EXT-UHD600-1SC Version A1

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

Sidelighter TM Optical distance to fault measurement module

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Fiber Meter. Specification & User Manual

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

SLD. Board FC/APC Connector. TEC Control. Board. Control Circuits. Control interface DB9 (Female)

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

Model DM8000-U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

THE ART OF ENGINEERING

MTP1000 with LaserBlade, VOABlade, PowerBlade & SwitchBlade Smarter Modular Test Platform

H5000 Outdoor Mini Virtual HUB

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Fibre Channel Fiber-to-Fiber Media Converters

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

U SER S G UIDE. TS2002A Fiber Optic Test Kit

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

4 Channel Video over Fiber With Ethernet

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

HP 70950B OPTICAL SPECTRUM ANALYZER

Long Distance L-Band Fiber Optic Links

Transcription:

MN9320A Optical Channel Drop Unit Independent Test Access Tool for Comprehensive DWDM Measurements

MN9320A Access to DWDM Channels and Traffic at One Location The technique of Dense Wavelength Division Multiplexing is well established and adopted worldwide as a means of increasing the traffic-carrying capacity of a fiber. Optical cross connects, and wavelength routing and translation now make a typical network far more complex in construction. Identification of an individual channel and verification of the data passing over it during installation, commissioning, and routine maintenance as part of a Service Level Agreement (SLA) is becoming more critical. The MN9320A Optical Channel Drop Unit is a test instrument that scans the DWDM optical signal and displays all those channels in the form of a bar graph. Any channel can be selected from this display and fed to the output port which can then be connected to an analyzer such as the Anritsu MP1570A for data validation and testing. Wherever the integrity of a DWDM signal must be verified, the MN9320A can be used. Product Features Independent DWDM signal access for channels of 50 GHz spacing or higher-up to data rates of 10 Gbps. Provides DWDM channel access to any BER tester Measurement of channel wavelength and power ±10 pm wavelength accuracy (typical) Optical output protection mode ITU-T 50 GHz, 100 GHz, or custom grid capability Proof of conformance to a customer SLA, isolation of points of failure or performance degradation in a DWDM network can be achieved by connecting the MN9320A to a monitor point in the network and connecting it to an analyzer such as the Anritsu MP1570A. Any DWDM channel signals can then be directed to the input of the BERT for analysis. Data at rates of up to 10 Gbps and at a spacing as close as 50 GHz are easily handled by the MN9320A. λ1 λ2 λ3 MN9320A MP1570A OADM Optical Amplifier OXC λ1 λ2 λ3 λn λn DWDM Multiplexer/ Demultiplexer

Functional and Simple to Use Single-button operation Channel table shows wavelength and optical power Any channel can be dropped Filter design prevents data corruption at 10 Gbps Access to Individual Channels on a DWDM System The optical filter design of the MN9320A is specifically intended to access (i.e. drop) an individual channel from a DWDM signal for analysis such as SONET/SDH, BER, Q-Factor, etc. The unique optical filter design combines a wide, flat top and steep sides with very strong adjacent channel rejection, ideally suited for high data rates, up to 10 Gbps. Channel Power and Wavelength Measurement The MN9320A provides accurate measurement of individual channel powers and wavelengths. Wavelength is measured in scan mode. Automatic Channel and Grid Detection The MN9320A enables the user to select a particular power level above which DWDM channels are expected. The unit will then scan and determine the wavelength and channel power of all channels in the measurement range. Results are then presented in tabular or bar graph format. The user can also save a custom grid based on the wavelengths measured. The new custom grid is stored for future use. Easy Channel Grid Management The MN9320A understands that channels are arranged in a grid, and that not all grids are the same. The user interface makes it easy to manage wavelengths based on standard ITU-T grids as well as custom grids. Removing and inserting channels can easily modify existing grids, creating new ones appropriate for the task at hand. Custom grids are easily stored and recalled, reducing measurement time and operator skill levels. Optical Output Protection Mode Any network data analyzer is an expensive test tool, yet the receiver can be easily damaged by the application of a high input power. The MN9320A offers a unique output protection mode to prevent this expensive mistake. When enabled, the unit has a preset level above which the output port will not activate. This level can be changed by the user. Incredible Wavelength Accuracy The optical components within the MN9320A are of the highest quality, providing wavelength accuracy of typically ±10 pm so you can be sure it goes back to the same spot, time after time.

High Resolution Color Display Local and Remote Operation Button Display Cursor Keys Used to Select Operational Functions Optical Output Active LED Optical Power Level Alarm LED Optical Input and Output Ports with Interchangeable Connector Adapters Not only is the MN9320A a useful measurement tool, it s an insurance policy that will protect your expensive analyzer

To avoid corruption of high data rate traffic within the channel, a filter shape with steep sides and a flat top is required. The filter technology used in the MN9320A provides superb shape for 10 Gbps traffic and minimal cross-talk between adjacent channels. The eye diagram demonstrates that the optical filter in the MN9320A has little or no effect on a 10 Gbps signal.

Specifications MN9320A Optical Channel Drop Unit Optical Performance Wavelength range Channel drop mode - Channel spacing - Data rate Wavelength accuracy Wavelength repeatability ORR @ 0.4 nm Filter full width @ 3 db @ 20 db Maximum input power Input power measurement range Power meter accuracy Insertion loss Display External interfaces EMC Safety Dimensions and mass Power Temperature range - Operation - Storage 1528 to 1565 nm 50 GHz and higher Up to 10 Gbps ±20 pm guaranteed, ±10 pm typical ±10 pm non-additive to wavelength accuracy >40 dbc typical 0.2 nm 0.6 nm +20 dbm -50 to +10 dbm ±0.5 dbm for -40 to +10 dbm 8 db max, <6 db typical Color STN 6" FVGA RS-232, 115 KBps, 200 KBps EN 61326: 1998 STD EN 61010-1: 1993 320(W) x 133(H) x 350(D) mm, 11 kg 115 VAC, 7.0 A, 50/60 Hz, or 230 VAC, 4.0 A, 50/60 Hz, auto-selecting (Typical load: <1.5A [115 VAC]; <1.0A [230 VAC]) 0 to 50 C -40 to +70 C Ordering Information Please specify the model or order number and quantity when ordering. Model Number Description Remarks Mainframe MN9320A C band Optical Channel Drop Unit* Standard accessories supplied with this unit: User s Guide AC power cord Protective front cover Options Optical Channel Drop Unit with: MN9320A-01 MN9320A-02 MN9320A-03 SC/UPC connectors ST/UPC connectors HMS-10/A connectors Application parts With storage for power cord, optical patch 760-218 Hard carry case cords, User s Guide, and other accessories J0617B J0618D J0618E J0618F J0619B Replaceable connector (FC) Replaceable connector (ST) Replaceable connector (DIN) Replaceable connector (HMS-10/A) Replaceable connector (SC) *Equipped with FC/UPC connectors

ANRITSU COMPANY 1155 East Collins Boulevard Richardson, TX 75081 http://www.us.anritsu.com SALES & SUPPORT UNITED STATES Tel: 1-800-ANRITSU Fax: 972-671-1877 CANADA Tel: 1-800-ANRITSU Fax: 613-828-5400 SOUTH AMERICA Tel: 55-21-527-6922 Fax: 55-21-537-1456 JAPAN Tel: 81-3-3446-1111 Fax: 81-3-3442-0235 ASIA-PACIFIC Tel: 65-282-2400 Fax: 65-282-2533 EUROPE Tel: +44 (0)1582-433433 Fax: +44 (0)1582-731303 Copyright 2002 Anritsu Company Specifications subject to change without notice. Other brand and product names may be trademarks or registered trademarks of their respective owners. January 2002 P/N : 80401-00128 Rev.1 Printed in USA