estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Similar documents
Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Standard signal metering in wall-mounting case

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Level Measurement silometer FMC 420, FMC 423

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

TUC: Universal thermostat

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Multi channel programmable Filter-Amplifier

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Capacitance Limit Detection nivotester FTC 420/421/422

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

HygroClip Introduction

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Assembly. Front view. LEDs. Parametrization interface. Power Bus

48x24. Options ORDER NUMBER OF TYPE PFL B

Speed sensor MiniCoder GEL 2471

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Process transmitter RMA422

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

SC / /205 Passive Audio Adapters User s Guide

DMP 331i / DMP 333i LMP 331 i

DISTRIBUTION AMPLIFIER

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Medium-Power-LED-Stripe MPS12-X-X-X-X

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

SH2RE16A4. Output relay module. Benefits. Description

SY-HDBT-SLIM-100S Extender Set

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Product information. Front-door station series with video for surface-mount

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Single Point Flow Monitor SW118 SW119

/ PAT01 USER MANUAL

DA1931CT/ TP to Video + Audio Receiver

Bimetal Temperature Switch

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

263 Series LED Bargraph Indicator and Controllers

DCP100 Digital Control Programmer Specifications

Inductive sensor NI3-EG08K-Y1-H1341

Magnetic Stirrers Magnetic Stirr

Litile34 OPERATION MANUAL

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Absolute Encoders Multiturn

Mechanical flow switch for On/Off control

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

LITE-ON TECHNOLOGY CORPORATION

SY-HDBT-100 Extender Set

.Power Distribution Center. PD-1. Instruction Manual

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

SY-MS121 SY-MS121-AP

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

MT IN, 2-OUT CAT-5 TO VGA RECEIVER CARD FOR MULTI-TASKER USER S GUIDE

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

4 Wiring Brochure Wiring and installation of specific control

LCD Thermometer / Clock S No. 1253

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

TP VGA/COMPONENT+ AUDIO TWISTED PAIR (UTP) TRANSMITTER

IMPAC Infrared Thermometers

INSTRUCTIONS FOR USE Pro-Ject Tube Box DS2

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Inductive sensor NI10-M18-Y1X-H1141

RSCC. Load cells. Special features. Data sheet

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

TP /351 HDMI Over Coax with IR

Cylindrical Photoelectric Sensor CY-100 SERIES

Model Number Structure

Lt DELTA USA, Inc

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Installation Guide. HDMI 4x1 Switcher

Actuators IC 20, IC 40

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Process Transmitter RMA 422

TP HDMI OVER ANYWIRE RECEIVER (DC)

Pressure transmitter COMPACT IO-Link,

INSTRUCTIONS FOR USE Pro-Ject Tube Box DS2

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Transcription:

Galltec ess- und Regeltechnik GmbH EA ensortechnik GmbH D-71145 Bondorf. Germany D-07987 ohlsdorf-teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0. Fax +49(0)3661-62704-20 E-ail: sensoren@galltec.de. Internet: E-mail:mela@melasensor.de. Internet: Electronic Humidistat with remote sensor head +125 C Easy to install up to 25 m cable length for remote sensor head 2 potential-free switching outputs configurable as openers or closers 2 independently configurable setpoints 2 independently configurable switching hystereses Display of current relay switching states 2 continuous 0...10 V signal outputs for relative humidity and temperature calibrated measuring probe in exchangeable plug-in design Alternating display of relative humidity and temperature ensor head up to +125 C Technical data Humidity easuring range etting range of the setpoints etting range of the switching hystereses easuring uncertainty 10...90 %rh at 25 C max 0...10 %rh and 90...100 %rh at 25 C ong term stability Hysteresis Typ. temperature influence at 25 C Temperature Output ranges ensor head high temperature easuring uncertainty 5...60 C 0...100 %rh 5...95 %rh 0.5...9 %rh ±2 %rh additional ±0.2 %rh / %rh 0.5 %rh/a ±1 %rh ±0.05%rh/K 0...+50 C -30...+70 C 0...+100 C -40...+125 C further ranges on request typ. ±0.2K Temperature influence at +5 C or +60 C tandard -40...5 C 12mK/K 60...80 C 14mK/K High temperature 60...100 C 14mK/K additional 100...125 C 20mK/K Electrical data witching outputs: etting as opener / closer witching voltage Breaking capacity 2 relay contacts potential-free, normally open Via DIP switch 48V DC / AC 100 µv 60 W / 62.5 VA Power factor 0.9 witching cycles (at Pmax) > 10 5 witching current Continuous output rel. humidity Continuous output temperature oad resistance (voltage output) upply voltage Consumption 2A 0...10 V DC 0...10 V DC 10 kω 15...30 V DC 13...26 V AC 30 ma Directive about electromagnetic compatibility 2014/30/EU DIN EN 61326-1 issue 07/13 DIN EN 61326-2-3 issue 07/13 Page 1 of 5

General data easuring medium Operating temperature housing sensor head (standard) sensor head+cable firmly connected sensor head high temperature torage temperature Electrical connections at mains terminals Wire cross-section at each connection Cable diameter urface-mounted cable Concealed cable see: user instructions on page 10 Air, non-pressurised, non-condensing, non-aggressive degree of protection cable sensor with membrane filter ZE08 (basic equipment) PTFE sintered filter ZE05 up to 125 C (optional) Housing IP rating afety category aterials housing cable sensor Housing colour Cable length of remote sensor head standard max. Display -30...+60 C -40...+85 C -40...+80 C -40...+125 C -40...+80 C max. 1.5 mm² max. 1 x Ø 6.5 mm or 2 x Ø 4.5 mm P65 IP 30D III AB PC signal white similar to RA 9003 2 m 25 m 2 lines 3 digits + 1 decimal place display approx. 21 x 40 mm² digit height approx. 8 mm T + H alternating relay switching state 1 + 2 Working range humidity and temperature rh / %r.h. 100 90 80 70 60 50 40 30 20 10 0-40 -20 0 20 40 60 80 100 120 Temp. / C page 2 of 10

Dimensional drawing Opening the housing Fixing flange (accessories) Drilling pattern 41 Drilling pattern of fixing flange 6 3 13 R29 60 120 12 4,3 83,1 29 19,4 93,4 29 20 1 11,5 41,5 47,5 10,5 1 11,5 41,5 47,5 10,5 37 page 3 of 10

Probe with cable Probe lengths: =78 =150 =220 Ø12 33 standard, firmly connected -40...+80 C high temperature -40...+125 C -40...+85 C (ZE08+ZE05) -40...+125 C (high temperature with ZE05) for (PTFE sintered filter) add another +4 mm Probe pluggable (not possible for cable probe high temperature +125 C) Probe lengths: =78 =150 =220 X=266 Ø12 33 41 probe -40...+85 C for (PTFE sintered filter) add another +4 mm -40...+80 C cable firmly connected Probe Versions X Page 4 of 10

-30 C...+60 C -40 C...+85 C (probe + connector) -40 C...+80 C (cable) -40 C...+125 C X X + Page 5 of 10

Description controller Controller for wall mounting with ventilation slots and display -30 +60 C (housing) with cable connected connector cable length 2m (without probe) -40 +80 C (cable) Description probe optional equipment / accessories X Probe pluggable with female socket election from 4 probe lengths:,,, X protective cage with membrane filter (ZE08) -40 +85 C (when plugged) X Probe pluggable with female socket election from 4 probe lengths:,,, X PTFE sintered filter (ZE05) -40 +85 C (when plugged) Controller for wall mounting with ventilation slots and display with integrated connector (without probe) -30 +60 C (when plugged) Probe election from 3 probe lengths:,, protective cage with membrane filter (ZE08) -40 +85 C (probe), cable max. +80 C (probe) with cable connected female cable connector, cable length 2m (pluggable in the housing) Probe election from 3 probe lengths:,, PTFE sintered filter (ZE05) -40 +85 C (probe), cable max. +80 C (when plugged) with cable connected female cable connector, cable length 2m (pluggable in the housing) Probe election from 3 probe lengths:,, PTFE sintered filter (ZE05) -40 +125 C (probe + cable) (when plugged) with cable connected female cable connector, cable length 2m (pluggable in the housing) connecting cable pluggable on both sides: cable end with cable plug connector to connect to the probe cable end with female cable connector to connect to the housing cable length 2m -40 +80 C Page 6 of 10

Description controller Controller for wall mounting with ventilation slots and display -30 +60 C (housing) (housing) with cable connected probe election from 3 probe lengths:,, cable length 2m protective cage with membrane filter (ZE08) -40 +85 C (probe), cable max. +80 C (probe) Controller for wall mounting with ventilation slots and display -30 +60 C (housing) (housing) with cable connected probe election from 3 probe lengths:,, cable length 2m PTFE sintered filter (ZE05) -40 +85 C (probe), cable max. +80 C (probe) Controller for wall mounting with ventilation slots and display -30 +60 C (housing) (housing) with cable connected probe election from 3 probe lengths:,, cable length 2m PTFE sintered filter (ZE05) -40 +125 C (probe + cable) (probe) Description probe optional equipment / accessories Accessories Product n Description 20.078 sintered filter ZE05 (instead of ZE08) made of fine-pored PTFE, IP 65 20.077 PTFE sintered filter ZE05 with O-Ring, - spare part 20.045 fixing flange, synthetic material, with fixing mechanism for easy sensor mounting and removal for sensors Ø 12 mm, with rubber sealing ZE 31/1-12 ZE 31/1-75 ZE 31/1-33 ZE 31/1-84 ZE36 humidity standard to check the accuracy of the sensor at 12 %RH humidity standard to check the accuracy of the sensor at 75 %RH humidity standard to check the accuracy of the sensor at 33 %RH humidity standard to check the accuracy of the sensor at 84 %RH testing adapter for humidity standards for for sensor tubes Ø 12 mm Page 7 of 10

Configuration guide Operation mode 51.3 %RH Alternately displays current relative humidity/temperature 1 2 2 displayed if relay 2 = contacts 7-8 closed 1 displayed if relay 1 = contacts 5-6 closed Press black button briefly: switch to Configuration mode P _ 1 %RH 40.0 %RH etpoint for relay 1; adjustable with rotary controller Press black button and hold (>3s): store value (display: tore ) Press black button briefly: witch to next parameter or (after turning rotary controller) display shows "_EC" and return to operation mode HY _ 1 %RH 3.0 %RH witching hysteresis for setpoint 1; adjustable with rotary controller Press black button and hold (>3s): store value (display: tore ) Press black button briefly: witch to next parameter or (after turning rotary controller) display shows "_EC" and return to operation mode P _ 2 %RH 60.0 %RH etpoint for relay 2; adjustable with rotary controller Press black button and hold (>3s): store value (display: tore ) Press black button briefly: witch to next parameter or (after turning rotary controller) display shows "_EC" and return to operation mode Press black button and hold (>3s): store value (display: tore ) HY _ 2 %RH 3.0 %RH witching hysteresis for setpoint 2; adjustable with rotary controller Press black button briefly: Return to operation mode or (after turning rotary controller) display shows "_EC" and return to operation mode page 8 of 10

etting relay 1 and 2 as opener or closer DIP-witch Current reading set to < setpoint value - switching hysteresis 2 > setpoint value + switching hysteresis 2 C (Closer) relay = open relay = closed O (Opener) relay = closed relay = open Connection diagrams 1 2 GND + U B 15 30 V DC or 13 26 V AC 5 6 Relay 1 Relay 1 relative humidity 3 4 Output humidity 0 10 V Output temperature 0 10 V 7 8 Relay 2 Relay 2 relative humidity Relay outputs: potential-free, normally open ED protection advice The devices contain components, which can be damaged by the effects of electrical fields or by charge equalisation when touched. The following protective measures must be taken when the housing of the device is to be opened for connection: Before opening the housing, ensure electrical potential equalisation between you and your environment. Pay particular attention to ensure that this potential equalisation is maintained while you are working with the opened housing. page 9 of 10

Installation instructions Position Operating temperature Connection to surface-mounted and concealed cables Connection The installation site of the remote probe should be chosen such that a representative measurement of air humidity can be guaranteed. Avoid areas in the vicinity of radiators, doors and exterior walls, as well as direct sunlight. Do not position the sensor where ingress of water could occur. protection is - only ensured with PTFE sintered filter ZE05 with O-Ring - only ensured when the probe is plugged, see Probe pluggable on page 4. We recommend that you lay the connection lines in a loop so that any water that may be present can run off. Please note the maximum permissible ambient temperature for probe and housing when installing the sensor. When firmly connected the standard cable must not be exposed to an increased ambient temperature > +80 C. When connecting to a concealed cable, the knock-out part of the housing floor should be broken out to allow the cable to pass through. When connecting to a surface-mounted cable, the separators at the hollowed-out points in the side of the housing can be broken out. The electrical connection must be carried out by properly qualified personnel only. The housing contains sensitive electrical components. When opening the housing, make sure you comply with the electrostatic discharge precautions. ines to and from the sensor and the sensor cable must not be installed parallel to strong electromagnetical fields. The installation site should be chosen such that a representative measurement of air humidity can be guaranteed User instructions Cleaning of filters and protective baskets Damaging influences If necessary, soiled filters and protective baskets can carefully be unscrewed and rinsed. Bear in mind the sensors will not measure accurately again until filters are completely dry. Depending on their type and concentration, aggressive media containing solvents can cause incorrect reasings or cause the sensor to fail. ubstances deposited on the sensor element (e. g. resin aerosols, paint aerosols, smoke deposits etc.) are harmful as they eventually form a water-repellent film. This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular application. Any existing industrial rights of protection must be observed. The quality of our products is guaranteed under our General Conditions of ale. Data sheet. Issue ay 2018. ubject to modifications. Page 10 of 10