This document lists specifications for the PXI-5691 RF amplifier.

Similar documents
USB Contents. Definitions SPECIFICATIONS. RF Power Sensor Device

Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1

NI PXI/PXIe-2543 Specifications

This document lists specifications for the NI PXIe-1491 high-definition multimedia interface (HDMI) analyzer.

Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 C to 55 C, unless otherwise noted.

2.7 GHz RF Vector Signal Analyzer with Digital Downconversion. This document lists specifications for the NI PXI-5661 RF vector signal analyzer.

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. may impair the protection the NI PXIe-7822R provides.

Note In this document, the NI 9202 with spring terminal and the NI 9202 with DSUB are referred to inclusively as the NI 9202.

NI 9260 DATASHEET. 2 AO, 3 Vrms, 24 Bit, 51.2 ks/s/ch Simultaneous

NI 9238 Datasheet DATASHEET. 4 AI, ±500 mv, 24 Bit, 50 ks/s/ch Simultaneous

NI 9246 DATASHEET. 3-Channel, 20 Arms Continuous, 24-Bit, Analog Input Module

NI 9244 Datasheet DATASHEET. 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

NI 9239 DATASHEET. 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI 9251 with mini XLR

NI 9230 DATASHEET. 3 AI, ±30 V, 24 Bit, 12.8 ks/s/ch Simultaneous

Specification Value Comments

NI R Series Multifunction RIO Specifications

NI GSM/EDGE+ Toolkit Specifications

Software. Documentation. Test Equipment

Thermocouple and RTD Modules for Compact FieldPoint

Digital Input Modules for Compact FieldPoint

USER MANUAL. Inverted Pendulum Experiment CAPTIVATE. MOTIVATE. GRADUATE.

Used for writing unscaled or raw data and covers the range from negative full scale (0) to positive full scale (65,535).

R&S ZN-Z154 Calibration Unit Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S ZN-Z85 Switch Matrix Specifications

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

PAM-1840 Preamplifier Operation Manual

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

NI USRP-2950R/2952R/2953R/ 2954R

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Supplement. TDS1000 and TDS2000 Series User Manual Specifications Update

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent 87405C 100 MHz to 18 GHz Preamplifier

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

PXIe-5667 (7 GHz) Contents GETTING STARTED GUIDE. Vector Signal Analyzer

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Specifications. Reference Documentation. Performance Conditions

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI PXI Contents GETTING STARTED GUIDE. 2.7 GHz RF Vector Signal Analyzer with Digital Downconversion

Wide Band Power Amplifier 6GHz~12GHz. Parameter Min. Typ. Max. Units Frequency Range 6 12 GHz Gain db Gain Flatness ±2.0 ±3.

NI PXIe Contents GETTING STARTED GUIDE. 6.6 GHz RF Vector Signal Analyzer with Digital Downconversion

USER MANUAL. IP02 Base Unit Experiment. Set Up and Configuration CAPTIVATE. MOTIVATE. GRADUATE.

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

R&S ZVA110 Vector Network Analyzer Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

R&S RT-Zxx High-Bandwidth Probes Specifications

RF Semiconductor Test AXRF RF Port Upgrade Kits

Simplified Block Diagram

R&S EDS300 DME/Pulse Analyzer Specifications

Agilent 87075C Multiport Test Set Product Overview

NI PXIe-5667 (3.6 GHz)

FP-AI-112 and cfp-ai-112

PXIe Contents GETTING STARTED GUIDE. 3.6 GHz or 14 GHz Vector Signal Analyzer

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Data Pattern Generator

PXI MICROWAVE IF DOWNCONVERTER MODULE

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

NI GSM/EDGE Toolkit Specifications

Agilent 8560 E-Series Spectrum Analyzers

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S FPC1000 Spectrum Analyzer Specifications

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Advanced Test Equipment Rentals ATEC (2832)

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

R&S DST200 RF Diagnostic Chamber Specifications

R&S ZND Vector Network Analyzer Specifications

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

RF2360 LINEAR GENERAL PURPOSE AMPLIFIER

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Advanced Test Equipment Rentals ATEC (2832)

NI PXIe-5668R. Contents GETTING STARTED GUIDE GHz or 14 GHz Vector Signal Analyzer

DEMO MANUAL DC2668A LTC5552 3GHz to 20GHz Microwave Mixer with Wideband DC to 6GHz IF BOARD PHOTO

ThinkRF D GHz RF Downconverter

WVR500 Waveform/Vector Monitor

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

R&S HF907DC SHF Downconverter Specifications

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

PXI MICROWAVE. Model PXI-1420

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Agilent 83000A Series Microwave System Amplifiers

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

R&S SMBV-Z1 Reference Frequency Converter Specifications

3500/42E Vibration Monitor

10 GHz to 26 GHz, GaAs, MMIC, Double Balanced Mixer HMC260ALC3B

PicoScope 6407 Digitizer

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

MAP110 AC-DC Series Data Sheet

Assembly Level Service Guide

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

USB Smart Power Sensor

TSG 90 PATHFINDER NTSC Signal Generator

Full-featured CW Microwave Counters for Field, Factory or Lab

NI WCDMA/HSPA+ Toolkit Specifications

Transcription:

DEVICE SPECIFICATIONS PXI-5691 RF Amplifier This document lists specifications for the PXI-5691 RF amplifier. Specifications are warranted under the following conditions: minutes warm-up time Calibration cycle maintained Chassis fan speed set to High PXI-5690 instrument driver used PXI-5690 instrument driver self-calibration performed after instrument temperature is stable Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 ºC to 55 ºC, unless otherwise noted. Typical values describe useful product performance beyond specifications that are not covered by warranty and do not include guardbands for measurement uncertainty or drift. Typical values may not be verified on all units shipped from the factory. Unless otherwise noted, typical values cover the expected performance of units over ambient temperature ranges of 23 C ± 5 C with a 90% confidence level, based on measurements taken during development or production. Nominal values (or supplemental information) describe additional information about the product that may be useful, including expected performance that is not covered under Specifications or Typical values. Nominal values are not covered by warranty. Specifications are subject to change without notice. For the most recent PXI-5691 specifications, visit ni.com/manuals. National Instruments RF devices are capable of producing and/or acquiring accurate signals within common Medical Implantable Communication System (MICS) frequency bands. NI RF devices are tested and verified in manufacturing for many measurements. For more information about RF device applications, visit ni.com/global to contact a National Instruments branch office. Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility document for important safety and electromagnetic compatibility information. To

obtain a copy of this document online, visit ni.com/manuals and search for the document title. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Caution The input and output connectors on your PXI-5691 are sensitive to electrostatic discharge (ESD). Always observe the safety precautions listed in the Electrostatic Discharge (ESD) Information section of the NI RF Signal Conditioning Devices Getting Started Guide. Caution Only apply input signals after you power on the PXI-5691, and remove input signals before you power off the PXI-5691. Figure 1. PXI-5691 Hardware Block Diagram CH 0 IN CH 0 OUT CH 1 IN Step Attenuator Direct Path Main Path CH 1 OUT Contents Frequency Range...3 Channels...3 Channel 0 (CH 0) Performance...3 Channel 1 (CH 1)... 8 Main Path... 8 Hardware Front Panel... 16 Power Requirements... 17 Calibration...17 Physical Characteristics... 18 Environment...18 Operating Environment...18 Storage Environment...18 Compliance and Certifications...19 Safety... 19 Electromagnetic Compatibility... 19 CE Compliance... 19 Online Product Certification... 19 Environmental Management... 20 2 ni.com PXI-5691 Specifications

Frequency Range Frequency range 50 MHz to 8.0 GHz Channels Number of channels 2 Gain Channel 0 Fixed Channel 1 Programmable Channel 0 (CH 0) Performance Level calibration accuracy 1 Absolute maximum input power (no damage) Maximum reverse power (no damage) Maximum output power DC voltage at input ±0.9 db +30 dbm typical (7.1 V rms, V pk at 50 Ω) +20 dbm +25 dbm ± V typical Gain variation by temperature (-1.18-12 F) 0.01 in db/ C 2 1 Valid for T ref ± 5 C. For temperatures other than T ref, the level calibration accuracy is valid after applying the gain correction factor for ΔT. 2 Calculate the correction factor using the following equation: Δ Gain = (Gain Variation by temperature) * ΔT, where ΔT = T sensor T ref T sensor = the temperature reading of the onboard temperature sensor in C, as reported by the ni5690 Get Temperature VI or the ni5690_gettemperature function F = frequency, in Hz T ref = 34 C PXI-5691 Specifications National Instruments 3

Table 1. PXI-5691 Channel 0: Gain Warranted Specification MHz 250 MHz 2 GHz 8 GHz Gain (Upper Bound) (db) Gain (Lower Bound) (db) 33.26 33.22 32.23 30.34 22.50 22.70 24. 21.44 The warranted specification is valid only between MHz and 8 GHz. Intermediate bounds can be determined by linearly interpolating the provided data. Figure 2. Measured Noise Figure (NF) 14.0 13.0 12.0 11.0.0 9.0 NF (db) 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 Maximum Typical 50 0 1,000 8,000 4 ni.com PXI-5691 Specifications

S12 (db) Figure 3. Measured Output Intercept Point (OIP 3 ) 36.0 35.0 34.0 33.0 OIP3 (dbm) 32.0 31.0 30.0 29.0 28.0 Minimum Typical 27.0 50 0 1,000 8,000 Figure 4. Measured Reverse Gain (S12) 0.0 20 30 40 50 60 0.0 2.0 4.0 6.0 8.0 Frequency (GHz) PXI-5691 Specifications National Instruments 5

Figure 5. Measured 1 db Gain Compression 24.0 22.0 20.0 P OUT (dbm) 18.0 16.0 14.0 12.0.0 50 0 1,000 8,000 Figure 6. Measured P IN at 1 db Gain Compression 4.0 2.0 0.0 P IN (dbm) 2.0 4.0 6.0 8.0.0 50 0 1,000 8,000 6 ni.com PXI-5691 Specifications

Figure 7. Measured 2nd Harmonic (P OUT = 4 dbm) 0 2 nd Harmonic Level (dbc) 20 30 40 50 0.0 50 0 1,000 8,000 Figure 8. Measured Saturated Output Power 26 25 24 Output Power (dbm) 23 22 21 20 19 18 17 16 50 0 1,000 8,000 PXI-5691 Specifications National Instruments 7

Channel 1 (CH 1) Main Path Gain range Gain step size +31.5 db typical +0.5 db typical Level setting time +4 µs maximum 3 Level calibration accuracy ±0.9 db 4 Absolute maximum input power (no damage) Maximum reverse power (no damage) Maximum output power DC voltage at input +30 dbm typical (7.1 V rms, V pk at 50 Ω) +20 dbm +25 dbm ± V typical Gain variation by temperature (-1.34-12 F) -0.01 in db/ C 5 Table 2. PXI-5691 Channel 1: Programmable Gain Warranted Specification MHz 3.25 GHz 4 GHz 8 GHz Maximum Gain (Upper Bound) (db) Maximum Gain (Lower Bound) (db) Minimum Gain (Upper Bound) (db) 34. 27.57 27.15 24.27 23.60 18.85 18.71 15.40 3.96-2.96-4.52-6.14 3 The level settling time is measured to 0.5 db of final value when switching from minimum to maximum gain. Achieving settling times closer to the final attenuation value may take substantially longer. 4 Valid for T ref ± 5 C. For temperatures other than T ref, the level calibration accuracy is valid after applying the gain correction factor for ΔT. 5 Calculate the correction factor using the following equation: Δ Gain = (Gain Variation by temperature) * ΔT, where ΔT = T sensor T ref T sensor = the temperature reading of the onboard temperature sensor in C, as reported by the ni5690 Get Temperature VI or the ni5690_gettemperature function T ref = 34 C F = frequency, in Hz 8 ni.com PXI-5691 Specifications

Table 2. PXI-5691 Channel 1: Programmable Gain Warranted Specification (Continued) MHz 3.25 GHz 4 GHz 8 GHz Minimum Gain (Lower Bound) (db) -7.00-11.90-12.65-16.53 The warranted specification is valid only between MHz and 8 GHz. Intermediate bounds can be determined by linearly interpolating the provided data. Figure 9. Average Measured Input and Output VSWR at Maximum Gain Setting 2.2 VSWR (:1) 2.0 1.8 1.6 1.4 Input and Output Maximum Input Output 1.2 1.0 0.0 2.0 4.0 6.0 Frequency (GHz) 8.0 Figure. Average Measured Input and Output VSWR at Minimum Gain Setting VSWR (:1) 2.0 1.8 1.6 1.4 Input Output 1.2 1.0 0.0 2.0 4.0 6.0 8.0 Frequency (GHz) PXI-5691 Specifications National Instruments 9

Figure 11. Measured Noise Figure (NF) 14.0 13.0 12.0 11.0.0 9.0 NF (db) 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 Maximum Typical 0.0 50 0 1,000 8,000 ni.com PXI-5691 Specifications

Figure 12. Measured Output Intercept Point (OIP 3 ) 36.0 35.0 34.0 33.0 32.0 OIP3 (dbm) 31.0 30.0 29.0 28.0 27.0 26.0 25.0 Minimum Typical 50 0 1,000 8,000 Figure 13. Measured Saturated Output Power (P SAT at Maximum Gain Setting) 26 25 24 23 P OUT (dbm) 22 21 20 19 18 17 16 50 0 1,000 8,000 PXI-5691 Specifications National Instruments 11

Figure 14. Measured Reverse Gain (S12) at Maximum Gain Setting 0.0.0 S12 (db) 20.0 30.0 40.0 50.0 0.0 2.0 4.0 6.0 8.0 Frequency (GHz) 24.0 Figure 15. Measured 1 db Gain Compression 22.0 20.0 P OUT (dbm) 18.0 16.0 14.0 12.0.0 50 0 1,000 8,000 12 ni.com PXI-5691 Specifications

Figure 16. Measured P IN at 1 db Gain Compression 4.0 2.0 0.0 P IN (dbm) 2.0 4.0 6.0 8.0.0 50 0 1,000 8,000 Figure 17. Measured 2nd Harmonic (P OUT = 4 dbm, Maximum Gain Setting) 0 2 nd Harmonic Level (dbc) 20 30 40 50 60 50 0 1,000 8,000 PXI-5691 Specifications National Instruments 13

Direct Path Level calibration accuracy ±0.9 db 6 Maximum input power (no damage) +30 dbm typical (7.1 V rms, V pk at 50 Ω) DC voltage at input ± V typical 7 Relay switch time 5 ms maximum Gain variation by temperature (-1.34-12 F) - 0.01 in db/ C 8 Direct Path Performance Table 3. PXI-5691 Channel 1: Direct Path Gain Frequency MHz 8 GHz Gain (Upper Bound) (db) 0.40-0.60 Gain (Lower Bound) (db) -0.60-3.40 Figure 18. Average Measured Input and Output VSWR 2.2 VSWR (:1) 2.0 1.8 1.6 1.4 Input and Output Maximum Input Output 1.2 1.0 0.0 2.0 4.0 6.0 Frequency (GHz) 8.0 6 Valid for T ref ± 5 C. For temperatures other than T ref, the level calibration accuracy is valid after applying the gain correction factor for ΔT. 7 DC coupled for input to output, but only calibrated from 50 MHz to 8 GHz. 8 Calculate the correction factor using the following equation: Δ Gain = (Gain Variation by temperature) * ΔT, where ΔT = T sensor -T ref T sensor = the temperature reading of the onboard temperature sensor in C, as reported by the ni5690 Get Temperature VI or the ni5690_gettemperature function T ref = 34 C F = frequency, in Hz 14 ni.com PXI-5691 Specifications

Channel 0/Channel 1 Cascaded Path Performance Figure 19. Average Measured Cascaded Gain Response 60.0 55.0 50.0 45.0 Gain (db) 40.0 35.0 30.0 CH 0 Main: CH 1 Maximum Gain CH 0 Main: CH 1 Minimum Gain 25.0 20.0 15.0.0 0.0 2.0 4.0 6.0 Frequency (GHz) 8.0 Note When cascading Channel 0 and Channel 1, each channel is individually calibrated. PXI-5691 Specifications National Instruments 15

Hardware Front Panel Figure 20. PXI-5691 RF Amplifier Front Panel NI PXI-5691 RF Amplifier ACCESS ACTIVE 50 MHz - 8 GHz IN +30 dbm MAX 50 CH 0 OUT +25 dbm MAX Reverse Power +20 dbm MAX 50 IN +30 dbm MAX 50 CH 1 OUT +25 dbm MAX Reverse Power +20 dbm MAX 50 CH 0 IN Connector Impedance Coupling Input amplitude SMA female 50 Ω AC +30 dbm maximum 16 ni.com PXI-5691 Specifications

CH 0 OUT Connector Impedance Coupling Output amplitude CH 1 IN Connector Impedance Coupling 9 Input amplitude CH 1 OUT Connector Impedance Coupling Output amplitude SMA female 50 Ω AC +25 dbm maximum SMA female 50 Ω AC +30 dbm maximum SMA female 50 Ω AC +25 dbm maximum Power Requirements Table 4. Power and Current Power Rail (V DC) Maximum Current (ma) Typical Current (ma) Maximum Power (W) +3.3 643 234 2.1 +5 1,382 1,3 6.9 +12 240 99 2.9-12 28 12 0.34 Calibration Interval 1 year 9 Direct path passes input DC level to output. PXI-5691 Specifications National Instruments 17

Physical Characteristics Dimensions Weight 3U, One Slot, PXI/cPCI Module 21.6 2.0 13.0 cm (8.5 0.8 5.1 in.) 263 g (9.2 oz) Environment Maximum altitude 2,000 m (at 25 C ambient temperature) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range Relative humidity range 0 C to 55 C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) % to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Storage Environment Ambient temperature range Relative humidity range Operational shock Random vibration Operating Nonoperating -40 C to 70 C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) 5% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL- PRF-28800F.) 5 Hz to 500 Hz, 0.3 g rms 5 Hz to 500 Hz, 2.4 g rms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL- PRF-28800F, Class 3.) 18 ni.com PXI-5691 Specifications

Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 6-1, EN 6-1 UL 6-1, CSA 6-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treament of material or inspection/analysis purposes. Note For EMC declarations and certifications, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/8/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. PXI-5691 Specifications National Instruments 19

Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee.htm. 电子信息产品污染控制管理办法 ( 中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物质指令 (RoHS) 关于 National Instruments 中国 RoHS 合规性信息, 请登录 ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. 2009 2017 National Instruments. All rights reserved. 375124F-01 Feb17