T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic

Similar documents
Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Compact live fiber identifier with integrated optical power meter

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Datasheet: MultiFiber Pro

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

FIP-400B Series. Fiber Inspection Probe and ConnectorMax2. User Guide

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert

OpticalProducts. Illuminating Your Network. Testing the World s Networks

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

IP LIVE PRODUCTION UNIT NXL-IP55

Datasheet: MultiFiber Pro Update

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

APPLICATION NOTE 4254 PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

FIBRE CHANNEL CONSORTIUM

Datasheet: CertiFiber Pro Optical Loss Test Set

Fiber Optics Redefined

192 Channel DMX Controller

Advanced Test Equipment Rentals ATEC (2832)

VIP-35 Manual. Video Inspection Probe

Model CMX3838A2 AV Matrix Switch with DSP audio (firmware 1.0)

Specifications subject to change without prior notice

IP LIVE PRODUCTION UNIT NXL-IP55 USO RESTRITO. OPERATION MANUAL 1st Edition (Revised 2) [English]

KVH Tri-Sat AutoSwitch Kit Installation and Operation Instructions for TracVision M3DX

RCIT Cable Certification Testing Revised 10/2017

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

American DJ. Show Designer. Software Revision 2.08

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

IQACO Changeover Switch

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Optical Component Environmental Test System

U SER S G UIDE. TS2002A Fiber Optic Test Kit

OP940. Insertion Loss & Return Loss Meter Instruction Manual. (Also supports the OP725 Integration)

CI-218 / CI-303 / CI430

RF Solution for LED Display Screen

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

OPERATIONS GUIDE OWL

Preface... Specification...14

Connectix Cabling Systems

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

Stretch More Out of Your Data Centre s Multimode Cabling System

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

How to overcome/avoid High Frequency Effects on Debug Interfaces Trace Port Design Guidelines

Datasheet: CertiFiber Pro Optical Loss Test Set

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

Arista 40G Cabling and Transceivers: Q&A

Fast Ethernet to Optical Media Converter MCE300T Data Sheet

FIBER QUICKMAP. Users Manual. Multimode Troubleshooter

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Pluggable Transceivers Installation Guide

SX7. Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

جامعة مؤتة العطاءات املركزية توريد وتركيب وتشغيل أجهزة شبكات/كلية الزراعة. Central Tenders Mu tah University

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Rack-Mount Receiver Analyzer 101

Using SignalTap II in the Quartus II Software

2 GENERAL DESCRIPTION

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

LGX Compatible (LSX) Connector Module) User Manual)

VSP 168HD Quick Start

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

TC1630. T1/E1 FIBER OPTIC MODEM User's Manual

Versiv makes you money every time you use it.

WCS-D800 Programming Software for the Icom ID-800

Quick Operation Guide of LTN7700/7600 Series NVR

7890MG Series Universal Media over IP Gateway for 10 x ASI/SD/HD/3G/GE User Manual

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

Model Colorado Ultra Wide Bandwidth HDTV Matrix Switch

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Troubleshoot Small Form-Factor Pluggable (SFP)/Cable Issues

DIGITAL VIDEO RECORDING (DVR) SERVICES

Datasheet: SimpliFiber Pro

TBS8030 HDMI Encoder User Guide

LMH0340/LMH0341 SerDes EVK User Guide

Ponderosa is expandable by 8 input and/or 8 output increments up to 64x64 in a 4RU frame. Typical Configurations:

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

DTA INSTALLATION PROCESS & USER GUIDE FOR SPECTRUM BUSINESS CUSTOMERS

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Installation Guide AT-HDR-EX-70-2PS

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Minimal Compression HD-SDI Video over IP Encoder, AES67 Support NMX-ENC-N1134A (FGN1134A-SA), Stand Alone NMX-ENC-N1134A-C (FGN1134A-CD), Card

9 Analyzing Digital Sources and Cables

UNIIQA+ NBASE-T Monochrome CMOS LINE SCAN CAMERA

Perle Fast Ethernet Media Converters

Connecting the Elecraft Power Combo to the Kenwood TS-2000 series Transceiver

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Transcription:

Quick Card T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic This quick card outlines how to configure and run a Fiber Channel Layer 2 Traffic Test with a recommended test suite of Throughput, Latency, Frame Loss, Buffer Credit and Buffer Credit Throughput. Equipment Requirements: T-BERD/MTS 5800 equipped with the following: o BERT software release V26.0 or greater o Test options: C51G2G4GFC for 1G, 2G or 4G Fiber Channel C58GFC for 8G Fiber Channel C510GFC for 10G Fiber Channel C516GFC for 16G Fiber Channel C532GFC for 32G Fiber Channel o SFP, SFP+, or SFP28 optical transceiver to match the line under test Jumper Cables to match the optical transceiver and the line under test Fiber optic inspection microscope (VIAVI P5000i or FiberChek Probe) Fiber optic cleaning supplies The following information is required to complete the test: Rate (1G, 2G, 4G, 8G, 10G, 16G, or 32G) Source and Destination IDs Maximum Bandwidth (Layer 1) If you are running the Buffer Credit Test: o Maximum Buffer Credit Size o Number of Steps Figure 1: Equipment Requirements Fiber Inspection Guidelines: Inspect and clean (if necessary) both sides of every fiber optic connection being used (bulkhead connectors, patch cords, and SFP ports) prior to reconnection for each test. Using the VIAVI P5000i or FiberChek Probe: Focus fiber on the screen. If dirty, clean the connector. If it appears clean, run inspection test. If it fails, clean fiber and re-run inspection test. Repeat until it passes. To inspect SFP ports with the P5000i, insert the probe tip into the SFP port, move the focus wheel all the way to one end, and slowly move the focus wheel to the other end. To inspect SFP ports with the FiberChek Probe, manually focus with middle toggle switch or pull the trigger to auto-focus. If a fiber stub (a darker circle on a lighter background as shown in figure 2) is detected, follow standard inspection and cleaning procedures. If you are unable to focus on a fiber end face, do not clean the port. The SFP contains a lens and cannot be cleaned. Figure 2: Image of Clean Fiber

Figure 3: T-BERD/MTS 5800v2 Dual Port mainframe Figure 4: T-BERD/MTS 5800-100G mainframe Connect to Line Under Test: For optical interfaces: Inspect and, if necessary, clean all SFPs, fibers, and bulkheads, as described on page 1. Insert desired SFP, SFP+ or SFP28 into the Port 1 (or Port 2) slot on the top of the T-BERD/MTS. Connect the SFP, SFP+ or SFP28 to the port under test using a Single Mode or Multimode jumper cable compatible with the interface under test. Launch Test: 1. Press the Power button to turn on the test set. Figure 5: Startup screen 2. Using the Select Test menu, Quick Launch menu, or Job Manager, launch a Fiber Channel L2 Traffic, Terminate test for the desire physical interface on port 1. For example: Fiber Channel 8G L2 Traffic P1 Terminate 3. Tap the Enhanced FC Test soft key.

Configure Test: 1. Tap the Go button for Start a New Configuration (Reset to defaults). 2. Tap the Next button to advance to the Fibre Channel Settings screen. 3. Enter your Source ID and Destination ID. 4. Tap the button 3 times to display the FC Test: Utilization screen. 5. Enter Max Bandwidth (L1 Mbps) required: 1GFC: up to 850 Mbps 2GFC: up to 1.7 Gbps 4GFC: up to 3.4 Gbps 8GFC: up to 6.8 Gbps 10GFC: up to 10.2 Gbps 16GFC: up to 13.6 Gbps 32GFC: up to 27.2 Gbps 6. Tap the button to display the FC Test: Frame Lengths screen. 7. Choose default or custom Frame Sizes. Three (3) Frame Sizes (76, 1024, and 2140) are recommended to cover the range and keep the test time short. 8. Tap the button 3 times to display FC Test: Buffer Credit Test screen.

9. Enter the Maximum Buffer Credit Size (between 1-65535). The test will start with this number, reducing the length of the test. 10. Enter the number of Steps to test for Buffer Credit Throughput (between 2 and 10). 11. Tap the button to display the Test CTRLS: Test Duration screen. 12. Enter a time Duration (5 2700 seconds) for each step of the test. 30 seconds is recommended. 13. Enter the Number of Trials for the test. 1 trial is recommended. 14. Tap the button to display the Test CTRLS: Test Thresholds screen. 15. Check desired checkboxes and enter pass/fail criteria for the test. Throughput is typically set to the Max Bandwidth configured in Step 5 above. Throughput Frame Loss Tolerance is typically set to 0. 16. Tap the button 3 times to display the Run FC Tests screen.

Run Test: 1. Tap the Run Tests button to start the test. 2. Verify that all tests pass or complete as indicated by a green or blue checkmark. 3. When the test is complete, tap the button 3 times to display the Reports screen. 4. Tap. After viewing the report, tap the button three times to close the report and exit the test. Contact Us +1 844 GO VIAVI) (+1 844 468 4284) To reach the VIAVI office nearest you, visit viavisolutions.com/contacts. 2018 VIAVI Solutions Inc. Product specifications and descriptions in this document are subject to change without notice.