ChannelPlus H17XL Series 2 User Operating Instructions

Similar documents
ServicePlus S17R Series 2 User Operating Instructions

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

Electronic 7 User Operating Instructions

1 Channel Multi-Purpose Programmer User Instructions

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

ST9100C User Guide. Features

7 Day Digital Programmer

7 Day Digital Programmer 3 Channel Surface Mount

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

USER & ENGINEER INSTRUCTION MANUAL

Programmable Room Thermostat With RF

Waterline Room Controller - Type WLCT3

ST625TX Digital Room Thermostat

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

7 Day Digital Light Switch with Optional Dusk Start

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

TDDFM14 OWNER S MANUAL

EN Wireless programmable thermostat

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

WiFi Controlled Fused Spur Time Switch

Digital Economy Seven Programmer

24Hour/7Day Electronic Timeswitch

Radio Thermostat Clock

Comfort System T-32-P Universal Thermostat. Operation Manual

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

16 Amp Electronic 24 Hour/7 Day Time Controller

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

SceneStyle2 User Guide

Inserting the batteries. Basic settings of the remote control

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

2 Verify that the green light

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

User interface. Abbreviations / Meanings

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Ducasa Digital Programmer

1. General Information:

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Philips LightMaster. KNX Timeclock Installation and Operation Manual

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Sample BD Tech Concepts LLC

Sample BD Tech Concepts LLC

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Operation Guide 6022 ENGLISH

XTM72E & F Real-Time Clock Modules

XTM72 Exerciser Timer Module

Digital Time Switch. Installation & Operating Instructions


7 Day Digital Time Switch

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

Master Time Clock MTC Users Manual

Installation Instructions

Aspect 2 Circuit Digital Scene Control

A digital version of this document is available to download and submit online at ADDRESS POST CODE

HD Digital Set-Top Box Quick Start Guide

Evolution Digital HD Set-Top Box Important Safety Instructions

Scoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control

Dimming actuators GDA-4K KNX GDA-8K KNX

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Nixie Clock Type Quattro'

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

Slimline Digital Electric Radiator. Step by Step Programming Guide

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

[I] SELECTING ACTUAL TIME. )lf~ IMPORTANT: INSTALLER, Please leave this guide with the householder together with its Warranty card.

FD Trinitron Colour Television

T2210HD/T2210HDA 21.5 Wide-Screen LCD Monitor User Manual

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

TS-4000 Multifunction Thermostat Timer Switch User Manual

USER MANUAL AL-Control 1 PRO

Battery Operated Controllers

Arduino Nixie Clock Modular Rev3

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

ZoneTouch V2 Zone Control System User Manual

Arduino Nixie Clock Modular Rev3

OPERATING INSTRUCTIONS

SET TOP BOX MODEL: GDB01SFV1 USER MANUAL

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

BLOCK OCCUPANCY DETECTOR

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Overview: Specifications: Installation Instructions:

OWNER S MANUAL. Base Station & Wireless Module COMFORT CALL SYSTEM

User s Guide. ECx Features: Automatic Sprinkler System Timer

Operation Manual. Model MCS350. Modular Communication System. Document No (01)

SPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Transcription:

ChannelPlus H17XL Series 2 User Operating Instructions Single Channel 7 day Timeswitch The ChannelPlus family of electronic programmers offer a range of advanced features coupled with simplified menu driven programming all designed to help save energy. The Horstmann ChannelPlus H17XL series 2 is a single channel timeswitch allowing up to 3 On/Off settings per day for each day of the week. For day to day operation the H17XL has a manual 1 or 2 hour boost button as well as an advance button to bring forward the next programmed operation. The back lit display, automatic clock and menu driven programming are all features designed to make the operation of the ChannelPlus H17XL as simple as possible to use. All series 2 ChannelPlus programmers are direct replacements for earlier ChannelPlus models. 1

The ChannelPlus H17XL Series 2 Timeswitch The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. Most of the following instructions require the front flap to be lowered. Please replace the flap when normal operation is required. PRODUCT OVERVIEW - DETAIL SHOWN WITH THE FLAP LOWERED 1 2 HTG 3 4 5 6 9 7 10 11 12 8 15 1 Current time of day 2 Day of week and date 3 Channel Heading 4 Current Channel programme 5 Next On/Off time 6 Channel ON indicator 7 ADVANCE and ENTER button ILLUMINATED WHEN ACTIVE 8 BOOST and COPY button ILLUMINATED WHEN ACTIVE 9 PLUS button 10 MINUS button 11 Programme Select buttons (Coloured Blue) 12 SET button (Coloured Green) 13 Front Flap (Lowered) 2

The ChannelPlus H17XL Series 2 timeswitch has a fully graphical, back-lit display. The information displayed will change depending upon the settings made and which mode you are in. During different programming modes and/or setting screens the current time, day/date, holiday indicator will only appear when necessary, this is to reduce confusion during the programming process. This is explained further in later sections of this guide. ACTIVATING THE BACK LIT DISPLAY The display will illuminate for approximately 1 minute whenever a button is pressed. To illuminate the display for viewing purposes only press the green menu button under the front flap twice. Display Information Channel header Time Day Date Holiday function active Channel/ Zone status SETTING AND ADJUSTING When setting or adjusting, the timeswitch will automatically return to the running mode if no buttons are pressed for approximately 1 minute. If the setting or adjusting has not been finished, please start the procedure again. TIME OF DAY The ChannelPlus H17XL incorporates a factory set clock and calendar which means that no adjustments should be necessary to the time of day and BST/GMT time changes take place automatically. 3

Manual Overrides BOOST FUNCTION - 1 OR 2 HOUR TEMPORARY OVERRIDE The boost facility will allow the user to either activate a channel which is currently OFF for 1 or 2 hours, or to extend a current on period by 1 or 2 hours. To indicate the boost being activated the BOOST button under the selected channel will stay illuminated for the duration of the boost/extension period. The display will also indicate the extension to the time visually on the display. Press BOOST button once: Your system will be boosted for 1 hour Press BOOST button twice: Your system will be boosted for 2 hours Press BOOST button a third time to cancel the period and return to the normal programme ADVANCE FUNCTION - BRINGS FORWARD THE NEXT ON OR OFF OPERATION The advance facility will allow the user to either bring a timeswitch ON which is currently OFF or switch a timeswitch OFF which is currently ON. To indicate the advance feature being activated the ADVANCE button will stay illuminated until the next programme switching time, the user display will change to also indicate the status of the timeswitch and the next switching time. Press ADVANCE button once to move to the next ON/OFF time To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme 4

Programme Override Facilities With the ChannelPlus H17XL Series 2 timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the blue select buttons under the front flap. The options include; AUTO - Timeswitch output follows all programmed ON and OFF times. ALL DAY - Timeswitch output operates from 1st ON time until 3rd OFF, ignoring all switching times in between. ON - OFF - Timeswitch output will be constantly ON. Timeswitch output will be constantly OFF, there is the ability to turn off heating during summer without altering the programme times. 1 or 2 hour boost still available. All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user. The diagram below illustrates how to alter the setting, it assumes that the timeswitch is in the AUTO mode to begin with. Press SELECT once. Programme goes from AUTO to ALL DAY Press SELECT again. Programme goes from ALL DAY to ON Press SELECT again. Programme goes from ON to OFF Press SELECT again. Programme goes from OFF to AUTO Timeswitch will operate from first ON until last OFF period Timeswitch will be continuously ON Timeswitch will be continuously OFF Programme will return to normal ON and OFF times 5

Setting the Programme Times The programme times have been preset as shown in the chart below. Default Time settings - am/pm 1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF Mon - Fri 6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM Sat/Sun 7.30AM 10.30AM 12.00PM 12.00PM 5.00PM 11.00PM Open cover If any changes are required to the programme times please complete the operation as described in the flowchart left. Select Set ON/OFF times SAMPLE DISPLAYS Select Set ON/OFF times SET ON/OFF TIMES buttons to select required day SET HOLIDAY MODE SET DEFAULTS required ON time Select the day to set SET ON/OFF TIMES Adjust OFF time Programme the remaining days Repeat process for the 2nd and 3rd time settings If you require this programme on any other day of the week use + and - buttons to select day and copy Close cover FOR WEDNESDAYS Enter the required on and off times SETTING ON/OFF TIMES ON 06.30 ON 12.00 ON 16.30 OFF 08.30 OFF 12.00 OFF 22.30 PERIOD 1 PERIOD 2 PERIOD 3 ADJUSTING SETTINGS When carrying out any alterations to the programmed times and settings the programmer will return to its normal run mode in 1 minute if no adjustments are made in that time. 6

Setting the Holiday Mode The holiday mode can be used to suspend the program function of the ChannelPlus timeswitch, it can be set in advance of your departure date and for as long a period as required. The holiday function operates from mid-day to mid-day, this means it can be easily set to ensure your home is warm for your return. When the holiday mode has been set a smiley face will appear on the display. When the holiday mode is active only the day/date and smiley face will be displayed. To cancel an active holiday period please press any of the Select buttons under the Open cover front flap. PLEASE NOTE: Any alteration to the current time or date will cancel any Holiday programme set. N.B. Do not use the holiday programme when conditions are such that frost damage to the heating system is possible (unless a frost protection thermostat is fitted to your system). SAMPLE DISPLAYS Enter Holiday Dates SETTING HOLIDAY MODE START AT MID-DAY ON 1 SEPT 2009 FINISH AT MID-DAY ON 21 SEPT 2009 Display when Holiday Mode is set thurs 16 SEPT start date start year buttons to select HOLIDAY MODE start month Repeat process for end period Close cover 7

Adjusting Default Settings The ChannelPlus H17XL Series 2 has a number of default settings which are normally installed. These settings are designed to reduce the need for user intervention upon installation of the timeswitch. However it is possible to customise the user display by following the procedures in the following pages. The factory default normally installed are illustrated below; Time and Date Time and calendar are factory set Clock Options Time displayed in 24hr clock format Headings Channel heading set to standard installation i.e. Heating, Hot Water or None 22:42 Options Options Options The timeswitch has been set with the current time and date during manufacture. No alteration should be required to the time and date. However, if any modification is required please refer to the flowchart on page 9 24 hour or AM/PM None Heating Water 8

Adjusting Time and Date The ChannelPlus H17XL Series 2 timeswitch has been set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modification is required please refer to the flowchart below. Open cover PLEASE NOTE: Any alteration to the current time or date will cancel any Holiday programme set. It will also cause any Boost or Advance operations to be cancelled. buttons to select SET DEFAULTS TIME AND DATE SAMPLE DISPLAYS THE CURRENT TIME SET ON/OFF TIMES SET HOLIDAY MODE SET DEFAULTS THE DAY THE YEAR THE MONTH SET DEFAULTS TIME AND DATE CLOCK OPTIONS HEADINGS 30 SEP 2009 TIME AND DATE 23.00 30 SEP 2009 Close cover 9

Open cover Adjusting Clock Options The timeswitch has been preset to display the time in 24 hour clock format, should you prefer AM/PM format then please use the procedure given in the flowchart opposite. buttons to select SET DEFAULTS SAMPLE DISPLAYS CLOCK OPTIONS SET ON/OFF TIMES SET HOLIDAY MODE SET DEFAULTS 24 HRS OR AM/PM SET DEFAULTS TIME AND DATE CLOCK OPTIONS HEADINGS Close cover CLOCK OPTIONS 24 HOURS AM/PM General Information BATTERY The timeswitch is fitted with a non-rechargeable, non-serviceable long life battery, which will maintain the clock and programmed time settings with the mains supply disconnected. THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank. SERVICE AND REPAIR This timeswitch is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE CHANNELPLUS H17XL section on the right. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician. 10

Open cover Adjusting Channel Headings The timeswitch has been preset without a channel heading on the display. If you require either the Water or Heating options then please follow the flowchart opposite. buttons to select SET DEFAULTS SAMPLE DISPLAYS HEADINGS SET ON/OFF TIMES SET HOLIDAY MODE SET DEFAULTS SET DEFAULTS HEATING/WATER ZONES OR CHANNELS Close cover SET DEFAULTS TIME AND DATE CLOCK OPTIONS HEADINGS HEADINGS NONE HEATING WATER General Information RESETTING THE CHANNELPLUS H17XL SERIES 2 Electronic equipment can in some circumstances be affected by electrical interference. If the display becomes frozen or scrambled; or if you wish to revert back to the default settings please use the following procedure: RESET PROCEDURE PLEASE NOTE: Using this procedure will restore the ChannelPlus to the original factory programme settings, the time setting will remain correct. Lower the front flap of the unit. On the right hand Channel press the ADVANCE (Enter) and SELECT (Blue) buttons together, then release and the programmer will return to the preset factory settings. ADVANCE BOOST SELECT RESET 11

What is a programmer?... an explantion for householders. Programmers allow you to set On and Off time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the On and Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen On and Off heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. The above explanation also applies to your timeswitch, which operates as a single circuit programmer. Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Horstmann Controls Limited, Bristol BS4 1UP 12 Leaflet number P82720 Issue 2