NI WCDMA/HSPA+ Toolkit Specifications

Similar documents
NI Measurement Suite for Mobile WiMAX Specifications

NI GSM/EDGE Toolkit Specifications

NI GSM/EDGE+ Toolkit Specifications

Software. Documentation. Test Equipment

USB Contents. Definitions SPECIFICATIONS. RF Power Sensor Device

NI PXI/PXIe-2543 Specifications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 C to 55 C, unless otherwise noted.

2.7 GHz RF Vector Signal Analyzer with Digital Downconversion. This document lists specifications for the NI PXI-5661 RF vector signal analyzer.

BNC-2090A QUICK START GUIDE. Rack-Mount Connector Accessory for E/M Series DAQ Devices

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

This document lists specifications for the PXI-5691 RF amplifier.

W-CDMA Base Station Transmitter Tests According to TS Rel. 10

R&S FPS-K18 Amplifier Measurements Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

NI USRP-2950R/2952R/2953R/ 2954R

NI R Series Multifunction RIO Specifications

Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1

PXIe-5667 (7 GHz) Contents GETTING STARTED GUIDE. Vector Signal Analyzer

This document lists specifications for the NI PXIe-1491 high-definition multimedia interface (HDMI) analyzer.

PXI UMTS DL Measurement Suite Data Sheet

Sample. Data Acquisition and Signal Conditioning. Course Manual. Course Software Version 2011 February 2012 Edition Part Number P-01

NI PXIe-5668R. Contents GETTING STARTED GUIDE GHz or 14 GHz Vector Signal Analyzer

Keysight Technologies M9421A VXT PXIe Vector Transceiver

Getting Started Guide

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ETSI TS V3.1.1 ( )

NI PXIe Contents GETTING STARTED GUIDE. 6.6 GHz RF Vector Signal Analyzer with Digital Downconversion

EUTRA/LTE Measurement Application Specifications

PXIe Contents GETTING STARTED GUIDE. 3.6 GHz or 14 GHz Vector Signal Analyzer

NI PXIe-5667 (3.6 GHz)

NI PXI Contents GETTING STARTED GUIDE. 2.7 GHz RF Vector Signal Analyzer with Digital Downconversion

LTE-A Base Station Performance Tests According to TS Rel. 12 Application Note

Getting Started Guide

<WCDMA Inner Loop Power Control tests, test pattern E&F,G&H using ARB files on the R&S CMW 500>

Tests on 3G-Base Stations to TS with FSIQ and SMIQ

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. may impair the protection the NI PXIe-7822R provides.

15dBm Triband Indoor Band Selective Repeater for Multiple Networks, Frequency Agile with Fixed Bandwidth

Sound and Vibration Data Acquisition

Keysight Technologies M9420A VXT PXIe Vector Transceiver

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

Digital Standards for Signal Generators Specifications

Specification Value Comments

WCDMA Base Station Performance Tests according to TS25.141

USB Smart Power Sensor

Agilent N5120A Baseband Studio for CPRI RE Test

Operation Guide for HSUPA Test Set-up According to 3GPP TS

RF Semiconductor Test AXRF RF Port Upgrade Kits

LTE-A Base Station Transmitter Tests According to TS Rel. 12. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA

REPORT ITU-R M Characteristics of terrestrial IMT-2000 systems for frequency sharing/interference analyses

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

NI SC Express. NI PXIe-4300 User Manual. NI PXIe-4300 User Manual. April A-01

Agilent N9360A Multi UE Tester

EUTRA/LTE Downlink Specifications

LTE RF Measurements with the R&S CMW500 according to 3GPP TS Application Note. Products: R&S CMW500

MX370x series software

Agilent M9362A-D01-F26 PXIe Quad Downconverter

USB Smart Power Sensor

USB Smart Power Sensor

The Internet of Things in a Cellular World

BELINTERSAT-1 HANDBOOK

FullMAX Air Inetrface Parameters for Upper 700 MHz A Block v1.0

Instrumentation Grade RF & Microwave Subsystems

Keysight E6650A EXF Wireless Test Set for Femtocell. Data Sheet

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

VXIbus Microwave Downconverter

DRAFT UK Interface Requirement 2102

Sound and Vibration Data Acquisition

ELECTRICAL TESTING FOR:

R&S FSW-K144 5G NR Measurement Application Specifications

Used for writing unscaled or raw data and covers the range from negative full scale (0) to positive full scale (65,535).

GTT LTE RRU ADD- ON USER GUIDE

R&S FSV-K40 Phase Noise Measurement Application Specifications

FP-AI-112 and cfp-ai-112

Co-location of PMP 450 and PMP 100 systems in the 900 MHz band and migration recommendations

Agilent Modular Instrumentation

Application Note DT-AN DTU-315 Verification of Specifications

MX370101A HSDPA/HSUPA IQproducer TM

NI 9239 DATASHEET. 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI 9238 Datasheet DATASHEET. 4 AI, ±500 mv, 24 Bit, 50 ks/s/ch Simultaneous

100 MHz, 100 MS/s, 14-Bit Digitizer

AH125 ½ W High Linearity InGaP HBT Amplifier

Note In this document, the NI 9202 with spring terminal and the NI 9202 with DSUB are referred to inclusively as the NI 9202.

NI 9251 with mini XLR

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

Tests On 3GPP WCDMA FDD Node Bs in Accordance with Standard TS

NI 9260 DATASHEET. 2 AO, 3 Vrms, 24 Bit, 51.2 ks/s/ch Simultaneous

Tests on 3G-Base Stations to TS with R&S Spectrum Analyzers and SMIQ Vector Signal Generator

PXI MICROWAVE. Model PXI-1420

MX269xxx series software

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

ETSI TS V1.1.1 ( )

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

APPLICATION NOTE MT8820A. Radio Communication Analyzer W-CDMA/GSM ANRITSU CORPORATION

LTE-A Base Station Transmitter Tests According to TS Rel. 13. Application Note. Products: R&S SMW200A R&S FSW R&S FSV R&S SMBV100A R&S FSVA

Internet of Things. RF-Test. Eduardo Inzunza Speaker Title 18-Jun-2017

Out of Band Spurious Measurement for Bluetooth Modules

OmniStar GX2 Headend Optics Platform

Transcription:

NI WCDMA/HSPA+ Toolkit Specifications Version 1.0 Generation This document lists specifications for the NI WCDMA/HSPA+ Toolkit. These specifications are representative and cannot be guaranteed for different frame configurations. In addition, these specifications cannot be guaranteed on all units shipped from the factory. Specifications are subject to change without notice. For the most recent toolkit specifications, visit ni.com/manuals. The data sheet for the NI WCMDA/HSPA+ Toolkit contains an overview of the product, including information about the various measurements and configurations the product supports. Refer to ni.com for the data sheet. Frequency range NI PXIe-5673/5673E... 85 MHz to 6.6 GHz Absolute amplitude accuracy... Refer to the NI PXIe-5673 Specifications or NI PXIe-5673E Amplitude resolution... Refer to the NI PXIe-5673 Specifications or NI PXIe-5673E

Downlink The generation specifications for downlink were derived using the following configuration: Power level: 10 dbm to 50 dbm Duplex mode: DL Only (FDD) Signal configuration: TM6 (8 HSPDSCH/30 DPCH) DL scrambling code type: Standard DL primary scrambling code: 0 DL scrambling code offset: 0 Payload data type: PN Sequence Payload PN order: 15 with the NI PXIe-5673/5673E Typical...< 0.5% Maximum...< 1% Range ACLR signal configuration...tm1 (64 DPCH) Range with the NI PXIe-5673 Offset Frequency Signal Average ±5 12 < 69 ±10 6 < 66 Range (db) (typical) NI WCDMA/HSPA+ Toolkit Specifications 2 ni.com

Uplink The generation specifications for uplink were derived using the following configuration: Power level: 10 dbm to 50 dbm Duplex mode: UL Only (FDD) Signal configuration: 1 DPCCH + 1 DPDCH UL number of channels: 2 UL frame type: Non-PRACH UL scrambling code type: Long DPCCH slot format: 0 (SF=256) DPDCH slot format: 0 (SF=256) DPCCH relative power: 3 db DPDCH relative power: 3 db DPDCH branch: I DPDCH spreading code: 2 DPDCH payload data type: PN Sequence DPDCH payload PN order: 15 with the NI PXIe-5673/5673E Typical... < 0.4% Maximum... < 0.5% Range Range with the NI PXIe-5673E Offset Frequency Signal Average ±5 11 < 72 ±10 13 < 68 Range (db) (typical) National Instruments Corporation 3 NI WCDMA/HSPA+ Toolkit Specifications

Analysis Frequency range NI PXIe-5663/5663E...10 MHz to 6.6 GHz ISM band...supported by NI PXIe-5663/5663E Maximum IF bandwidth NI PXIe-5663/5663E...50 MHz Frequency measurement accuracy...refer to the NI PXIe-5663 Specifications or NI PXIe-5663E Power measurement accuracy...refer to the NI PXIe-5663 Specifications or NI PXIe-5663E Downlink The analysis specifications for downlink were derived using the following configuration: Power level: 10 dbm to 30 dbm Duplex mode: DL Only (FDD) Signal configuration: TM6 (8 HSPDSCH/30 DPCH) DL scrambling code type: Standard DL primary scrambling code: 0 DL scrambling code offset: 0 Payload data type: PN Sequence Payload PN order: 15 with the NI PXIe-5663/5663E Typical...< 0.5% Maximum...< 1% NI WCDMA/HSPA+ Toolkit Specifications 4 ni.com

Offset Frequency Range ACLR signal configuration... TM1 (64 DPCH) Range with the NI PXIe-5663E Signal Average RFSA Reference Level (dbm) Noise Compensation ±5 6 4 off < 60 ±10 0 0 off < 64 Range (db) (typical) Uplink The analysis specifications for uplink were derived using the following configuration: Power level: 10 dbm to 30 dbm Duplex mode: UL Only (FDD) Signal configuration: 1 DPCCH + 1 DPDCH UL number of channels: 2 UL frame type: Non-PRACH UL scrambling code type: Long DPCCH slot format: 0 (SF=256) DPDCH slot format: 0 (SF=256) DPCCH relative power: 3 db DPDCH relative power: 3 db DPDCH branch: I DPDCH spreading code: 2 DPDCH payload data type: PN Sequence DPDCH payload PN order: 15 National Instruments Corporation 5 NI WCDMA/HSPA+ Toolkit Specifications

Offset Frequency with the NI PXIe-5663/5663E Typical...< 0.4% Maximum...< 0.5% Range Range with the NI PXIe-5663E Signal Average RFSA Reference Level (dbm) Noise Compensation ±5 9 15 off < 63 ±10 1 4 off < 67 Range (db) (typical) LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2010 National Instruments Corporation. All rights reserved. 373291A-01 Oct10