FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Similar documents
FLOMAT Electromagnetic Insertion Flowmeter

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

MT03A Electronic converter for flow rate transmitters

Mechanical flow switch for On/Off control

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Electronic converter for level transmitters MT03L Instructions manual

Wall-/Pipe-Mount Level Indicator

ELE C TRO MAG N E T I C FLO W M E T E RS

800 Displaying Series Flowmeter

Single Point Flow Monitor SW118 SW119

Magnetic Stirrers Magnetic Stirr

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Solenoid valves VZWD, directly actuated

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Electronic converter for flowmeters MT03F Instructions manual

MICROPROCESSOR CALCULATION MODULE - S2000

PROPORTIONAL VALVES Sentronic plus

istep STEPPER MOTOR PUMP

Capacitance Limit Detection nivotester FTC 420/421/422

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

2291 Guided Wave Radar Level Transmitter

Magnetic Sensor - Incremental EHP

istep STEPPER MOTOR PUMP

Solenoid valves VZWD, directly actuated

Process Transmitter RMA 422

Henkel Installation Handbook LINEGUARD 2001

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Modular Lube Lubrication Systems System Controls

Flow Measurement SITRANS F M

Level Measurement silometer FMC 420, FMC 423

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

2.9 Sigma/ 2 Plunger Metering Pumps

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Capacitance Level Measurement Electronic insert FEC 12

Pressure transmitter COMPACT IO-Link,

SITRANS F M. Transmitter MAG 5000/6000 4/33

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Scanning System S-2100

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Signet 2250 Hydrostatic Level Sensor

SCALE & WEIGHT DISPLAYS

General Specifications

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Dissolved Oxygen Transmitter

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Welding equipment for the POLYSTIC system

Flow Measurement SITRANS F M

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

DVZ. Compact Vortex Flowmeter. for Low Viscosity Liquids

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

DOME OPTIC SPLICE CLOSURE

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Capacitive sensor BCT5-S18-UP6X2T-H1151

Selection matrix for electronic pressure switches

AF-300 E11 Adjustable Frequency Drive

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Electromechanical Level Measurement Systems silopilot FMM 760, FMM 760 Z

GRUNDFOS alldos product information. The solution for complex dosing tasks

Dissolved Oxygen Transmitter

Model KBF 115 Constant climate chambers with large temperature / humidity range

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

Guided Wave Radar Level Meter

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

MAGNETOSTICTIVE TRANSDUCER

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Sensor technologies Proximity sensors Series ST4. Brochure

Quality products from a single source

Absolute Encoders Multiturn

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

ENC - LKE51 - L I B

Lt DELTA USA, Inc

Process transmitter RMA422

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

DFT. Compact Paddle Flow Sensor

Operating Instructions for Throttle Valves Using VRC Valve Positioner

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

Transcription:

Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering. Flow rate for liquids with electrical conductivity better than 20 µs/cm, for example: - Water treatment - Sewage treatment - cid, neutral or alkaline solutions - Chemical and pharmaceutical products Suitable for use at low and medium temperatures. The body is constructed in stainless steel ISI 36, on request available in PVDF wetted parts with electrodes in Hastelloy C, Zirconium, Titanium. Benefits Readings are independent of density, temperature, viscosity and pressure. lternating magnetic field for metering avoids electrolysis. bsence of obstructing elements gives low pressure loss and will allow the pass of solids. Can be mounted in any position, provided that the pipe is always full. Low power consumption. Good stability with temperature and age. No moving parts provides zero maintenance. Can be installed with short straight pipe sections (0 DN / 5DN). Good chemical resistance of construction materials. Metering Body Technical Data Rating Pressure (bar) PN 6 Liquid Temperature range PVDF Head -20 ºC...+30 ºC Electrodes Standard Hastelloy C Special Order Titanium, Zirconium Field coil current 30 m 6.25 / 7.5 Hz Liquid Conductivity > 20 µs / cm ccuracy + 3,5% NOTE: For temperatures above 70 ºC it may be necessary to separate the control unit from the metering body, depending on air temperature and ventilation of the control unit.

Measurement Principle The Flomat electromagnetic insertion flowmeter consists of a sensor which generates a magnetic field in the liquid to measure. The conductive liquids, as they flow through the magnetic field (5), generate a voltage E 6 (6) between the electrodes (3) which is proportional to the liquid velocity (V 7 ). The generated voltage is processed by the microprocessor electronic circuit () to give outputs of m or Hz proportional to the flow rate (Q 6 ). V 7 Q 8 6 5 5 3 3 4 2 Q 6 = K. V 7.E 6 FLOMT/MC The standard microprocessor control unit that will adapt to all Flomid & Flomat measuring bodies is designed to cover most industrial process requirements. For Flomat measuring bodies it is always supplied in separate mounting version. Technical Data Housing : IP-65 protected in coated aluminium (polyamide ). Magnetic push buttons operated from the exterior. Batching relay with partial and total volume counter. Remote push button for batching. Galvanic separation between measuring body and all outputs. utomatic switch over for flow direction. Magnetic Field : 6.25 Hz square wave for 50 Hz mains (7.5 Hz for 60 Hz mains). Mains supply : 2 V, 24 V, 0 V, 20 V, 220 V, 240 V ± 0% 50 or 60 Hz Consult factory for other options. Specify voltage and frequency when ordering. Power consumption : < 0 V Minimum flow rate : 0.5 m/s ( 3% nominal Qnom at 5 m/s) indicated by LED pilot light. Measuring range : 0.5 m/s... 7 m/s Display : 6 character x 2 lines LCD (back light optional). Selection of 6 working display formats. Flow rate indication in m3 /h. Totalising volume counter up to 00,000,000 m3. Batching relay : programmable in m3 with partial volume counter. nalog output : programmable voltage (4 ranges) and current ( 0-20 m and 4-20 m). Pulse output : programmable 0.00 Hz... 0,000 Hz larms: Two relays programmable to act as flow rate alarms or as empty pipe and flow direction alarms. daptive filter : integration time programmable 0.... 25.5 s RS 232 C baud rates : programmable 300, 600, 200, 2400, 4800, 9600, 9200 Linearity : 0. % Zero drift : 0.05% Temperature drift 0.05% / ºC Working Temperature -0 ºC... + 60 ºC 2

Control Units FLOMT MC/T, MC/FT & MC/S The MC series of microprocessor control units have available economical solutions to cover most industrial processes which require specific solutions, such as: The FLOMT MC/T, is an analog transmitter. (m & Hz.without local indication) for flow rate transmission applications to panel meters, control units such as automats & PLC s. The FLOMT MC/FT, is a fast analog transmitter. This series of instruments can be supplied in two basic mounting options: Compact version in which the electronics housing is mounted directly on the FLOMT metering body. Separate version in which the electronics housing is mounted separate from the FLOMT metering body with 2 m of cable. (m, without local indication) for analog flow rate control applications which need a fast response time. The FLOMT MC/S is a flow switch. (Without local indication) for flow detection, max. or min, alarms etc. with a relay output. FLOMT MC/T (nalog & Frequency output) Technical Data Housing : IP-65 protected in coated aluminium (polyamide ). Galvanic separation between measuring body and outputs. Selectable flow direction (by means of jumpers). Magnetic Field : 6.25 Hz square wave for 50 Hz mains (7.5 Hz for 60 Hz mains). Mains supply : 2 V, 24 V, 0 V, 20 V, 220 V, 240 V ± 0% 50 or 60 Hz Consult factory for other options. Specify voltage and frequency when ordering. Power consumption : < 0 V Minimum flow rate : 0.5 m/s ( 3% nominal Qnom at 5 m/s). Measuring range : 0.5 m/s... 0 m/s nalog output 0-5 V, 0-0 V, - 5 V, 2-0 V 4-20 m, 0-20 m Output frequency 0...00 Hz standard. Linearity : 0.3 % Zero drift : 0.5% Temperature drift 0.05% / ºC Working Temperature -0 ºC... + 60 ºC Factory adjusted. 3

FLOMT MC/FT (Fast nalog output) Technical Data Housing : IP-65 protected in coated aluminium (polyamide ). Without galvanic separation between measuring body and output. Selectable flow direction (by means of jumpers). Response time 200 ms. Magnetic Field : 2.5 Hz square wave for 50 Hz mains (5 Hz for 60 Hz mains). Mains supply : 2 V, 24 V, 0 V, 20 V, 220 V, 240 V ± 0% 50 or 60 Hz Consult factory for other options. Specify voltage and frequency when ordering. Power consumption : < 0 V Minimum flow rate : 0.5 m/s (3% nominal Qmax at 5 m/s). Measuring range : 0.5 m/s... 0 m/s nalog outputs 0-5 V, 0-0 V, - 5 V, 2-0 V 4-20 m, 0-20 m 3 output ranges 0-00%, 0-50% & 0-25% of full scale, by means of jumpers. Linearity : 0.3 % Zero drift : 0.5% Temperature drift 0.05% /ºC Working Temperature -0 ºC... + 60 ºC Factory adjusted. FLOMT MC/S (Relay output) Technical Data Housing : IP-65 protected in coated aluminium (polyamide ). utomatic changeover for flow direction. Magnetic Field : 6.25 Hz square wave for 50 Hz mains (7.5 Hz for 60 Hz mains). Mains supply : 2 V, 24 V, 0 V, 20 V, 220 V, 240 V ± 0% 50 or 60 Hz Consult factory for other options. Specify voltage and frequency when ordering. Power consumption : < 0 V Minimum flow rate : 0.5 m/s (3% nominal Qmax at 5 m/s). Measuring range : 0.5 m/s... 0 m/s Relay output, 250 V SPDT potential free contacts. Zero drift : 0.5% Temperature drift 0.05% / ºC Working Temperature -0 ºC... + 60 ºC Switch point selectable in 0, m/s steps. 4

Installation 2 x 9 46 Dimensions in mm F DN C* (H) Flange Nut 89 70 F 40...00 05 5...5 90...88 F 25...300 05 9...45 82...53 300 80 77 55 350...400 05 52...60 46...32 500...000 20 75...50 25...50 400 280 (H) (H) 200...2000 360 80...300 68...40 550 430 *pproximately 5 % of DN C* C* DN DN Installation with Flange DN-00...DN-2000 Installation with Nut DN-40...DN-2000 Sensor Construction 0 Electronics housing luminium 02 Connectors Plastic 03 Flange/BSP nut ISI-36 04 Body ISI-36 05 Mounting Insert ISI-36 06 Field Coil 07 Head PVDF 08 Electrodes Hastelloy C Flow rate table in m 3 /h Fluid speed m/s DN 0,5 5 0 00 4, 4 282 25 22, 22 442 50 3,8 38 636 200 56,5 565.3 225 7,5 75.43 250 88,3 883.767 300 27,2.272 2.544 350 73,2.732 3.463 Fluid speed m/s DN 0,5 5 0 400 226,2 2.262 4.524 500 353,4 3.534 7.068 600 508,9 5.089 0.78 700 692,7 6.927 3.854 800 904,8 9.048 8.095 900.45,.45 22.902 000.43,7 4.37 28.274 200 2.035,7 20.357 40.74 The electronics is normally supplied adjusted at 5 m/s full scale except the Flomat MC/S which is adjusted for 0 m/s full scale. 5

Dimensions and weights Remote Version Mounting (29) Standard flanged version (Others on demand) Weight,5 Kg Compact Version Mounting (2 x 9 x 89) 46 (226) 22 0 284 2 9 8 8 70 68 70 03 O 6,5; 4 holes a 90 o (6) 22 45 e / c 73 2 9 O 70 O 84 8 O 38 O 38 8 2 / 4 BSP thread (Others on demand) Weight 0,9 Kg (2 x 9 x 89) 46 e / c 73 O 6,5 O 70 O 84 O 38 O 38 2 / 4 BSP thread (Others on demand) Weight,9 Kg Standard flanged version (Others on demand) Weight 2,5 Kg 6

Remote Version Mounting With MC Electronics 03 220 00 3 30 60 60 76 40 PG 0 260 280 With MC/T...FT, S Electronics 46 22 20 76 80 PG PG PG 7

Installation Mounting of 2 or more Flomat (DN-700...DN2000) Install with a straight section of minimum 0 DN length before and 5 DN after. The pipe should always be full - install in a rising section. Mounting of one Flomat (DN-40...DN600) 30 O 30 O 30 O Recommended Optimum Zone Recommended Optimum Zone 20 O 20 O Recommended Optimum Zone 20 O * 30 O 30 O * Correct mounting positions to avoid air pockets and dirt deposits on the electrodes. NOTE.- Blue zone not recomended Valves should be mounted after the sensor to maintain a full pipe. Pumps should be installed before the sensor. Open Channel 50 h h = length to be specified We are at your service, please consult us. TECFLUID develops and manufactures instruments for gases and liquids, using the most advanced techniques. Request Information by telephone nº 34-93-372 45 C/. Narcis Monturiol, 33-08960 SNT JUST DESVERN (BRCELON) International: Telephone. 34-93-372 45 - Fax 34-93-473 44 49 www.tecfluid.com - e-mail: tecfluid@tecfluid.com Data in this pamphlet is subject to modification without notification, if the technical innovations in the product or manufacturing processes so require.technical