Oildyne 550 Series Hydraulic Power Units. Pressures to 207 bar (3000 psi) Flows to 11.4 lpm (3 gpm)

Similar documents
RA / Functional description 1/8. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Gear Pump Units For single-line centralized lubrication systems

Product information Modular standard ABSKG unit

Fluid Cooling P-BAR b Industrial BOL Series

SureFire PDI Lubricator

82540/ /2-way diaphragm valves

Gear Pump Units. For single-line lubrication systems

Portable Filter Cart Type SPFC

Screw pump Series ALLFUEL AFT

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

Series description: Wilo-Drain VC

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

Type D mechanical diaphragm

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Size B INDUSTRIAL STANDARD

Agilent High Capacity RV Pumps & Roots Pumping Systems

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

MAXX BOX. MX102/202 Series. MAXX Box

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Modular Lube Lubrication Systems System Controls

lumenalpha spot Specification Sheet

Oil/air cooler. Table of contents. Features. Applications. RE 50112/05.13 Replaces: Type KOL and KOLP

Micro-Machined Silicon Transducers

Thermo Scientific Merlin Recirculating Chillers

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Series description: Wilo-Sub TWU 3 HS

Selection matrix for electronic pressure switches

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

HyPrecision Waterjet. Optimizing waterjet performance

Mechanical flow switch for On/Off control

MDT3 and MDT4 Service Parts

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Okta 1000, Roots pump without motor

Cooling systems for ORBIMAT

Immersion Pumps HCT (High Chem) sealless

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

HyPrecision Waterjet. The world's most profitable waterjets

OVZ. Economical Oval-Gear Flow Meter. For Viscous Oils

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

% & ) ANSI Accredited Program

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

Bimetal Temperature Switch

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

SERIES 400 SERIES 620

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

NE-18 Series Mains / Power Switches

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

BC104 BATCH CONTROLLER

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Briggs&Stratton 44Q B1

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

In addition to the basic models it is also possible for the units to be outfitted with add-ons.

PRIMEROYAL Series. Metering Pump. Model PN

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

(1,1) -1- X-HTA-1000.indd 3/13/2009 1:26:09 PM ABOVE AND BEYOND HONING. HTA Series HORIZONTAL TUBE HONING SYSTEMS

FLUID COOLING Industrial BOL Series

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Data Sheet Definite Purpose Contactors Ex9CK Series

HANNAY REELS. Audio/Video Reels. For use in: Production & Recording Facilities Television & Radio Stations

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Compact Vacuum Systems

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Tools Amphenol CTL Crimp Series

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Part-Turn Electric Multi-Turn Electric

SMALL OIL SEALED PUMPS

AristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection

Sentinel I24 Digital Input and Output Configuration

Single Point Flow Monitor SW118 SW119

10 PDUs 19 PDUs Zero-U PDUs

Optical Cryostat - Economy

Bartels Micropumps. ( ) Rev. 2.8

Magnetic and Hydraulic-Magnetic Circuit Breaker

Spring Return dosing pump FM - mechanical diaphragm

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Kuhnke Technical Data. Contact Details

Series CDP2 Definite Purpose Contactors

PRIMEROYAL Series API 675 metering pump

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Up to 85% higher Service Life due to efficient sealing method.

Thermo Scientific ThermoChill Series Recirculating Chillers. Performance, value, simplicity

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Digital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Distributed Design Series

Leading Provider of Cable Management Solutions. M8 & M12 Cordsets & Accessories

Butterfly Valve Retrofits

Integrated Tote Mixer

SR Series. Spring Return dosing pump D - mechanical diaphragm. The right dosing choice

THE NEW CHOICE IN MANEUVERING

Features XT SC 012 B B A

Proportional output thumbwheels - sprung to centre

Revision 1.0 Parts List Mega

Transcription:

Oildyne ressures to 207 bar (3000 psi) Flows to 11.4 lpm (3 gpm) aerospace climate control electromechanical filtration hydraulics pneumatics process control sealing & shielding

ower Unit Features We are pleased to introduce our new C hydraulic power units. he combines the features and benefits our customers and markets have requested in a durable and economical package. he integral motor, pump and reservoir are complemented with a full line of arker D03 and cartridge valve options. dd a linear or rotary actuator and you have a complete hydraulic system solution for your application. Features Numerous motors up to 3 hp 6 pump sizes flows from 1 to 11.4 lpm ( 1 /4 to 3 gpm) Externally adjustable relief valve Variety of reservoirs 207 bar (3000 psi) capability D03 pad or standard and ports hese high quality power units are ideal for industrial machine tool clamping circuits, dock levelers, food processing, hose crimping, scissor lift, presses, and a myriad of C applications. Let them go to work for you. Your local arker sales representative will be pleased to provide further information. ypical pplications Machine tool clamping Dock levelers Man lifts Scissors lifts Wheelchair lifts rash compactors Hose crimpers oat lifts resses Commercial ovens 20 arker Hannifin Corporation

erformance Data 6.6 (400) 550 ower Units @ 1725 RM 13.1 (800) 550 ower Units @ 3450 RM 5.7 (350) 20 11.5 (700) 20 4.9 (300) 17 9.8 (600) 17 Output Flow - lpm (cipm) 4.1 (250) 3.3 (200) 2.5 (150) 14 10 07 Output Flow - lpm (cipm) 8.2 (500) 6.6 (400) 4.9 (300) 14 10 07 1.6 (100) 3.3 (200) 04 04 0.8 (50) 1.6 (100) 0 0 34 69 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000) Operating ressure - bar (psi) erformance data based on F @ 21 C ( 70 F) 0 0 34 69 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000) Operating ressure - bar (psi) Motor Horsepower Recommendations at Flow/ressure ump Nominal GM ressure (SI) Size @1725 @3450 500 1000 1500 2000 2500 3000 04 ₁ ₄.50 H.50 H.50 H.50 H.50 H.50 H 04 ₁ ₂.50 H.50 H.50 H.75 H 1.0 H 1.0 H 07 ₁ ₂.50 H.50 H.50 H.75 H 1.0 H 1.0 H 07 1.50 H.75 H 1.0 H 1.5 H 2.0 H 2.0 H 10 ₃ ₄.50 H.50 H.75 H 1.0 H 1.5 H 1.5 H 10 1 ₁ ₂.50 H 1.0 H 1.5 H 2.0 H 3.0 H 3.0 H 14 1.50 H.75 H 1.0 H 1.5 H 2.0 H 2.0 H 14 2.75 H 1.5 H 2.0 H 3.0 H 17 1 ₁ ₄.50 H 1.0 H 1.5 H 2.0 H 2.0 H 17 2 ₁ ₂ 1.0 H 2.0 H 3.0 H 20 1 ₁ ₂.50 H 1.0 H 1.5 H 2.0 H 20 3 1.0 H 2.0 H 3.0 H Note: erformance data is for reference only 21 arker Hannifin Corporation

echnical Specifications Standard roduct Ordering Code 550 550 OWER UNI - includes relief valve MOOR SELECION - EFC Single hase = 115/230 VC, 60 HZ hree hase = 230/460 VC, 60 HZ CODE H RM HSE C.50 1725 Single D.50 1725 hree M.50 3450 Single.50 3450 hree E.75 1725 Single F.75 1725 hree N.75 3450 Single U.75 3450 hree J 1.0 1725 Single K 1.0 1725 hree 1.0 3450 Single W 1.0 3450 hree L 1.5 1725 Single O 1.5 1725 hree Q 1.5 3450 Single X 1.5 3450 hree V 2.0 1725 Single R 2.0 1725 hree S 2.0 3450 Single Y 2.0 3450 hree H 3.0 3450 hree UM SIZE CODE DISLCEMEN 04.04 CIR 07.07 CIR 10.10 CIR 14.14 CIR 17.17 CIR 20.20 CIR RESERVOIR CODE VOLUME 05 0.5 Gal. Steel 10 1.0 Gal. Steel 15 1.5 Gal. Steel 50 5.0 Gal. Steel 06 0.5 Gal. lastic 11 1.0 Gal. lastic 16 1.5 Gal. lastic 26 2.5 Gal. lastic CIRCUI CODE DESCRIION D0 D03 ad & Extension Fittings D1 D03 ad with Dual O Check Manifold (Manapak) (for use with D03 Directional Control Valves) S Standard ressure & ank orts SW Std & orts with Outlet ort Check Valve wo osition wo Way Cartridge Valves Following circuits include outlet port check valve: S1 12 VDC, Normally Closed, Conduit Connector S2 24 VDC, Normally Closed, Conduit Connector S3 120 VC, Normally Closed, Conduit Connector S4 240 VC, Normally Closed, Conduit Connector S5 12 VDC, Normally Open, Conduit Connector S6 24 VDC, Normally Open, Conduit Connector S7 120 VC, Normally Open, Conduit Connector S8 240 VC, Normally Open, Conduit Connector Note: 5 gal. steel reservoir can be mounted vertically only. ll others are vertical and horizontal ready 1 2 3 4 5 6 7 8 12 VDC, Normally Closed, DIN Connector 24 VDC, Normally Closed, DIN Connector 120 VC, Normally Closed, DIN Connector 240 VC, Normally Closed, DIN Connector 12 VDC, Normally Open, DIN Connector 24 VDC, Normally Open, DIN Connector 120 VC, Normally Open, DIN Connector 240 VC, Normally Open, DIN Connector 22 arker Hannifin Corporation

echnical Specifications 4-WY VLVE (LL D03 SIZE) CODE DESCRIION (For use only with Circuit Codes D0 and D1) NNN No 4-Way Valve Included 01Y Closed Center, 120 VC, Conduit Connectors 01 Closed Center, 240 VC, Conduit Connectors 01K Closed Center, 12 VDC, Conduit Connectors 01J Closed Center, 24 VDC, Conduit Connectors 02Y Open Center, 120 VC, Conduit Connectors 02 Open Center, 240 VC, Conduit Connectors 02K Open Center, 12 VDC, Conduit Connectors 02J Open Center, 24 VDC, Conduit Connectors 07Y Float Center, 120 VC, Conduit Connectors 07 Float Center, 240 VC, Conduit Connectors 07K Float Center, 12 VDC, Conduit Connectors 07J Float Center, 24 VDC, Conduit Connectors 08Y andem Center, 120 VC, Conduit Connectors 08 andem Center, 240 VC, Conduit Connectors 08K andem Center, 12 VDC, Conduit Connectors 08J andem Center, 24 VDC, Conduit Connectors 30Y Single Solenoid, 120 VC, Conduit Connector 30 Single Solenoid, 240 VC, Conduit Connector 30K Single Solenoid, 12 VDC, Conduit Connector 30J Single Solenoid, 24 VDC, Conduit Connector Y01 01 K01 J01 Y02 02 K02 J02 Y07 07 K07 J07 Y08 08 K08 J08 Y30 30 K30 J30 FLOW CONROL (for use with Cartridge Valves) CODE DESCRIION NN None (use with D0 and D1 circuits) H None (use with all other circuits) F1 ress. Comp.,.5 to 1.0 GM F2 ress. Comp., 1.0 to 2.0 GM Closed Center, 120 VC, Hirschmann w/out lugs Closed Center, 240 VC, Hirschmann w/out lugs Closed Center, 12 VDC, Hirschmann w/out lugs Closed Center, 24 VDC, Hirschmann w/out lugs Open Center, 120 VC, Hirschmann w/out lugs Open Center, 240 VC, Hirschmann w/out lugs Open Center, 12 VDC, Hirschmann w/out lugs Open Center, 24 VDC, Hirschmann w/out lugs Float Center, 120 VC, Hirschmann w/out lugs Float Center, 240 VC, Hirschmann w/out lugs Float Center, 12 VDC, Hirschmann w/out lugs Float Center, 24 VDC, Hirschmann w/out lugs andem Center, 120 VC, Hirschmann w/out lugs andem Center, 240 VC, Hirschmann w/out lugs andem Center, 12 VDC, Hirschmann w/out lugs andem Center, 24 VDC, Hirschmann w/out lugs Single Solenoid, 120 VC, Hirschmann w/out lug Single Solenoid, 240 VC, Hirschmann w/out lug Single Solenoid, 12 VDC, Hirschmann w/out lug Single Solenoid, 24 VDC, Hirschmann w/out lug RV SEING In multiples of 100 psi Examples 04 = 400 psi 12 = 1200 psi 29 = 2900 psi Hydraulic Fluid ny clean hydraulic oil with a viscosity of 150 to 300 SUS at 38 C (100 F) is acceptable. If another type of fluid is needed, please consult the factory. emperature Range Normal operating range is -7 C to 60 C (+20 F to +140 F). lease consult the factory for applications outside this range. 23 arker Hannifin Corporation

Circuits S CIRCUI SW CIRCUI S1-S4, 1-4 CIRCUIS S5-S8, 5-8 CIRCUIS 24 arker Hannifin Corporation

Circuits S1-S4, 1-4 CIRCUIS WIH RESSURE COMENSED FLOW CONROL F1 OR F2 S5-S8, 5-8 CIRCUIS WIH RESSURE COMENSED FLOW CONROL F1 OR F2 CLOSED CENER FLO CENER SINGLE SOLENOID OEN CENER NDEM CENER D0 CIRCUI (D03 VLVE O E SELECED) D1 CIRCUI INCLUDES MNK DUL 0 CHECK VLVE (D03 VLVE O E SELECED) 25 arker Hannifin Corporation

Dimensions Dimensions 134.6 (5.30) 135.1 (5.32) 88.9 ( 3.50 ) SINGLE HSE ONLY MOOR HEIGH 237.2-299.7 (9.34-11.80) 24.1 ( 0.95 ) 24.1 ( 0.95 ) 9/16-18 UNF-2 SE-6 SR HD O-RING ORS FILLER/REHER 25.8 ( 1.02 ) 51.3 ( 2.02 ) 191.8 ( 7.55 ) 1/2 GL (2 liters) 251.5 ( 9.90 ) 1 GL (4 liters) 311.1 ( 12.25) 1-1/2 GL (5.6 liters) 430.5 ( 16.95) 2-1/2 GL (9.5 liters) ( 6.75 ) 215.9 ( 8.50 ) 231.9 ( 9.13 ) 171.5 87.4 ( 3.44 ) shown with and ports and plastic reservoir 158.9 ( 6.25) Ø182.1 MX (7.17) 62.0 ( 2.44 ) 62.0 ( 2.44 ) Note: When mounted in the horizontal configuration the 2 1 /2 gallon plastic reservoir must be supported 165.1 ( 6.50) 101.6-169.1 (4.00-6.50) 76.2 ( 3.00) HIRD NGLE ROJECION 65.0 ( 2.56) 4X 8.6 (.34) SLO Motor foot dimensions are common to all electric motors Note: ll dimensions in mm (inches). 26 arker Hannifin Corporation

Dimensions 134.6 (5.30) 135.1 (5.32) 88.9 (3.50) SINGLE HSE ONLY MOOR HEIGH 237.2-299.7 (9.34-11.80) 9/16-18 UNF-2 SE-6 SR HD O-RING ORS RELIEF VLVE 25.8 (1.02) WO WY VLVE (OIONL) LEDS 18G 609.6 (24.00) LONG SRIED ENDS 24.1 (0.95) 101.3 (3.99) 177.8 (7.00) 1/2 GL (2 LIER) 304.8 (12.00) 1 GL (4 LIER) 24.1 (0.95) 406.4 (16.00) 1-1/2 GL (5.6 LIER) FILLER/REHER 98.0 (3.86) 51.3 (2.02) REURN FLOW CONROL (OIONL) HIRD NGLE ROJECION HIRD NGLE ROJECION 140.4 (5.53) shown with optional solenoid 2-way valve and steel reservoirs Note: ll dimensions in mm (inches). 27 arker Hannifin Corporation

Dimensions 58.6 ( 2.31) 231.6 ( 9.12) 63.6 ( 2.51) HIRD NGLE ROJECION 181 ( 7.13) 66.8 ( 2.63) 82.6 ( 3.25) 93.5 ( 3.68) 39.9 ( 1.57) 215.9 ( 8.50) 2X 9/16-18 UNF-2 FLRE UE END (OIONL) 131.8 ( 5.19) Ø171.5 ( 6.75) GUGE OR LOCION SE-6 SR HD O-RING OR 9/16-18 UNF-2 FILLER/REHER 51.3 ( 2.02) 598.8 ( 23.58) 25.8 ( 1.02) 311.3 ( 12.26) 34.9 ( 1.38) 4X Ø 9.5 (.38) RESERVOIR MN HOLES 362 ( 14.25) 387.4 ( 15.25) 50.8 ( 2.00) shown with D03 valve, Manapak block and 5 gallon reservoir Note: ll dimensions in mm (inches). 28 arker Hannifin Corporation