Oildyne ressures to 207 bar (3000 psi) Flows to 11.4 lpm (3 gpm) aerospace climate control electromechanical filtration hydraulics pneumatics process control sealing & shielding
ower Unit Features We are pleased to introduce our new C hydraulic power units. he combines the features and benefits our customers and markets have requested in a durable and economical package. he integral motor, pump and reservoir are complemented with a full line of arker D03 and cartridge valve options. dd a linear or rotary actuator and you have a complete hydraulic system solution for your application. Features Numerous motors up to 3 hp 6 pump sizes flows from 1 to 11.4 lpm ( 1 /4 to 3 gpm) Externally adjustable relief valve Variety of reservoirs 207 bar (3000 psi) capability D03 pad or standard and ports hese high quality power units are ideal for industrial machine tool clamping circuits, dock levelers, food processing, hose crimping, scissor lift, presses, and a myriad of C applications. Let them go to work for you. Your local arker sales representative will be pleased to provide further information. ypical pplications Machine tool clamping Dock levelers Man lifts Scissors lifts Wheelchair lifts rash compactors Hose crimpers oat lifts resses Commercial ovens 20 arker Hannifin Corporation
erformance Data 6.6 (400) 550 ower Units @ 1725 RM 13.1 (800) 550 ower Units @ 3450 RM 5.7 (350) 20 11.5 (700) 20 4.9 (300) 17 9.8 (600) 17 Output Flow - lpm (cipm) 4.1 (250) 3.3 (200) 2.5 (150) 14 10 07 Output Flow - lpm (cipm) 8.2 (500) 6.6 (400) 4.9 (300) 14 10 07 1.6 (100) 3.3 (200) 04 04 0.8 (50) 1.6 (100) 0 0 34 69 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000) Operating ressure - bar (psi) erformance data based on F @ 21 C ( 70 F) 0 0 34 69 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000) Operating ressure - bar (psi) Motor Horsepower Recommendations at Flow/ressure ump Nominal GM ressure (SI) Size @1725 @3450 500 1000 1500 2000 2500 3000 04 ₁ ₄.50 H.50 H.50 H.50 H.50 H.50 H 04 ₁ ₂.50 H.50 H.50 H.75 H 1.0 H 1.0 H 07 ₁ ₂.50 H.50 H.50 H.75 H 1.0 H 1.0 H 07 1.50 H.75 H 1.0 H 1.5 H 2.0 H 2.0 H 10 ₃ ₄.50 H.50 H.75 H 1.0 H 1.5 H 1.5 H 10 1 ₁ ₂.50 H 1.0 H 1.5 H 2.0 H 3.0 H 3.0 H 14 1.50 H.75 H 1.0 H 1.5 H 2.0 H 2.0 H 14 2.75 H 1.5 H 2.0 H 3.0 H 17 1 ₁ ₄.50 H 1.0 H 1.5 H 2.0 H 2.0 H 17 2 ₁ ₂ 1.0 H 2.0 H 3.0 H 20 1 ₁ ₂.50 H 1.0 H 1.5 H 2.0 H 20 3 1.0 H 2.0 H 3.0 H Note: erformance data is for reference only 21 arker Hannifin Corporation
echnical Specifications Standard roduct Ordering Code 550 550 OWER UNI - includes relief valve MOOR SELECION - EFC Single hase = 115/230 VC, 60 HZ hree hase = 230/460 VC, 60 HZ CODE H RM HSE C.50 1725 Single D.50 1725 hree M.50 3450 Single.50 3450 hree E.75 1725 Single F.75 1725 hree N.75 3450 Single U.75 3450 hree J 1.0 1725 Single K 1.0 1725 hree 1.0 3450 Single W 1.0 3450 hree L 1.5 1725 Single O 1.5 1725 hree Q 1.5 3450 Single X 1.5 3450 hree V 2.0 1725 Single R 2.0 1725 hree S 2.0 3450 Single Y 2.0 3450 hree H 3.0 3450 hree UM SIZE CODE DISLCEMEN 04.04 CIR 07.07 CIR 10.10 CIR 14.14 CIR 17.17 CIR 20.20 CIR RESERVOIR CODE VOLUME 05 0.5 Gal. Steel 10 1.0 Gal. Steel 15 1.5 Gal. Steel 50 5.0 Gal. Steel 06 0.5 Gal. lastic 11 1.0 Gal. lastic 16 1.5 Gal. lastic 26 2.5 Gal. lastic CIRCUI CODE DESCRIION D0 D03 ad & Extension Fittings D1 D03 ad with Dual O Check Manifold (Manapak) (for use with D03 Directional Control Valves) S Standard ressure & ank orts SW Std & orts with Outlet ort Check Valve wo osition wo Way Cartridge Valves Following circuits include outlet port check valve: S1 12 VDC, Normally Closed, Conduit Connector S2 24 VDC, Normally Closed, Conduit Connector S3 120 VC, Normally Closed, Conduit Connector S4 240 VC, Normally Closed, Conduit Connector S5 12 VDC, Normally Open, Conduit Connector S6 24 VDC, Normally Open, Conduit Connector S7 120 VC, Normally Open, Conduit Connector S8 240 VC, Normally Open, Conduit Connector Note: 5 gal. steel reservoir can be mounted vertically only. ll others are vertical and horizontal ready 1 2 3 4 5 6 7 8 12 VDC, Normally Closed, DIN Connector 24 VDC, Normally Closed, DIN Connector 120 VC, Normally Closed, DIN Connector 240 VC, Normally Closed, DIN Connector 12 VDC, Normally Open, DIN Connector 24 VDC, Normally Open, DIN Connector 120 VC, Normally Open, DIN Connector 240 VC, Normally Open, DIN Connector 22 arker Hannifin Corporation
echnical Specifications 4-WY VLVE (LL D03 SIZE) CODE DESCRIION (For use only with Circuit Codes D0 and D1) NNN No 4-Way Valve Included 01Y Closed Center, 120 VC, Conduit Connectors 01 Closed Center, 240 VC, Conduit Connectors 01K Closed Center, 12 VDC, Conduit Connectors 01J Closed Center, 24 VDC, Conduit Connectors 02Y Open Center, 120 VC, Conduit Connectors 02 Open Center, 240 VC, Conduit Connectors 02K Open Center, 12 VDC, Conduit Connectors 02J Open Center, 24 VDC, Conduit Connectors 07Y Float Center, 120 VC, Conduit Connectors 07 Float Center, 240 VC, Conduit Connectors 07K Float Center, 12 VDC, Conduit Connectors 07J Float Center, 24 VDC, Conduit Connectors 08Y andem Center, 120 VC, Conduit Connectors 08 andem Center, 240 VC, Conduit Connectors 08K andem Center, 12 VDC, Conduit Connectors 08J andem Center, 24 VDC, Conduit Connectors 30Y Single Solenoid, 120 VC, Conduit Connector 30 Single Solenoid, 240 VC, Conduit Connector 30K Single Solenoid, 12 VDC, Conduit Connector 30J Single Solenoid, 24 VDC, Conduit Connector Y01 01 K01 J01 Y02 02 K02 J02 Y07 07 K07 J07 Y08 08 K08 J08 Y30 30 K30 J30 FLOW CONROL (for use with Cartridge Valves) CODE DESCRIION NN None (use with D0 and D1 circuits) H None (use with all other circuits) F1 ress. Comp.,.5 to 1.0 GM F2 ress. Comp., 1.0 to 2.0 GM Closed Center, 120 VC, Hirschmann w/out lugs Closed Center, 240 VC, Hirschmann w/out lugs Closed Center, 12 VDC, Hirschmann w/out lugs Closed Center, 24 VDC, Hirschmann w/out lugs Open Center, 120 VC, Hirschmann w/out lugs Open Center, 240 VC, Hirschmann w/out lugs Open Center, 12 VDC, Hirschmann w/out lugs Open Center, 24 VDC, Hirschmann w/out lugs Float Center, 120 VC, Hirschmann w/out lugs Float Center, 240 VC, Hirschmann w/out lugs Float Center, 12 VDC, Hirschmann w/out lugs Float Center, 24 VDC, Hirschmann w/out lugs andem Center, 120 VC, Hirschmann w/out lugs andem Center, 240 VC, Hirschmann w/out lugs andem Center, 12 VDC, Hirschmann w/out lugs andem Center, 24 VDC, Hirschmann w/out lugs Single Solenoid, 120 VC, Hirschmann w/out lug Single Solenoid, 240 VC, Hirschmann w/out lug Single Solenoid, 12 VDC, Hirschmann w/out lug Single Solenoid, 24 VDC, Hirschmann w/out lug RV SEING In multiples of 100 psi Examples 04 = 400 psi 12 = 1200 psi 29 = 2900 psi Hydraulic Fluid ny clean hydraulic oil with a viscosity of 150 to 300 SUS at 38 C (100 F) is acceptable. If another type of fluid is needed, please consult the factory. emperature Range Normal operating range is -7 C to 60 C (+20 F to +140 F). lease consult the factory for applications outside this range. 23 arker Hannifin Corporation
Circuits S CIRCUI SW CIRCUI S1-S4, 1-4 CIRCUIS S5-S8, 5-8 CIRCUIS 24 arker Hannifin Corporation
Circuits S1-S4, 1-4 CIRCUIS WIH RESSURE COMENSED FLOW CONROL F1 OR F2 S5-S8, 5-8 CIRCUIS WIH RESSURE COMENSED FLOW CONROL F1 OR F2 CLOSED CENER FLO CENER SINGLE SOLENOID OEN CENER NDEM CENER D0 CIRCUI (D03 VLVE O E SELECED) D1 CIRCUI INCLUDES MNK DUL 0 CHECK VLVE (D03 VLVE O E SELECED) 25 arker Hannifin Corporation
Dimensions Dimensions 134.6 (5.30) 135.1 (5.32) 88.9 ( 3.50 ) SINGLE HSE ONLY MOOR HEIGH 237.2-299.7 (9.34-11.80) 24.1 ( 0.95 ) 24.1 ( 0.95 ) 9/16-18 UNF-2 SE-6 SR HD O-RING ORS FILLER/REHER 25.8 ( 1.02 ) 51.3 ( 2.02 ) 191.8 ( 7.55 ) 1/2 GL (2 liters) 251.5 ( 9.90 ) 1 GL (4 liters) 311.1 ( 12.25) 1-1/2 GL (5.6 liters) 430.5 ( 16.95) 2-1/2 GL (9.5 liters) ( 6.75 ) 215.9 ( 8.50 ) 231.9 ( 9.13 ) 171.5 87.4 ( 3.44 ) shown with and ports and plastic reservoir 158.9 ( 6.25) Ø182.1 MX (7.17) 62.0 ( 2.44 ) 62.0 ( 2.44 ) Note: When mounted in the horizontal configuration the 2 1 /2 gallon plastic reservoir must be supported 165.1 ( 6.50) 101.6-169.1 (4.00-6.50) 76.2 ( 3.00) HIRD NGLE ROJECION 65.0 ( 2.56) 4X 8.6 (.34) SLO Motor foot dimensions are common to all electric motors Note: ll dimensions in mm (inches). 26 arker Hannifin Corporation
Dimensions 134.6 (5.30) 135.1 (5.32) 88.9 (3.50) SINGLE HSE ONLY MOOR HEIGH 237.2-299.7 (9.34-11.80) 9/16-18 UNF-2 SE-6 SR HD O-RING ORS RELIEF VLVE 25.8 (1.02) WO WY VLVE (OIONL) LEDS 18G 609.6 (24.00) LONG SRIED ENDS 24.1 (0.95) 101.3 (3.99) 177.8 (7.00) 1/2 GL (2 LIER) 304.8 (12.00) 1 GL (4 LIER) 24.1 (0.95) 406.4 (16.00) 1-1/2 GL (5.6 LIER) FILLER/REHER 98.0 (3.86) 51.3 (2.02) REURN FLOW CONROL (OIONL) HIRD NGLE ROJECION HIRD NGLE ROJECION 140.4 (5.53) shown with optional solenoid 2-way valve and steel reservoirs Note: ll dimensions in mm (inches). 27 arker Hannifin Corporation
Dimensions 58.6 ( 2.31) 231.6 ( 9.12) 63.6 ( 2.51) HIRD NGLE ROJECION 181 ( 7.13) 66.8 ( 2.63) 82.6 ( 3.25) 93.5 ( 3.68) 39.9 ( 1.57) 215.9 ( 8.50) 2X 9/16-18 UNF-2 FLRE UE END (OIONL) 131.8 ( 5.19) Ø171.5 ( 6.75) GUGE OR LOCION SE-6 SR HD O-RING OR 9/16-18 UNF-2 FILLER/REHER 51.3 ( 2.02) 598.8 ( 23.58) 25.8 ( 1.02) 311.3 ( 12.26) 34.9 ( 1.38) 4X Ø 9.5 (.38) RESERVOIR MN HOLES 362 ( 14.25) 387.4 ( 15.25) 50.8 ( 2.00) shown with D03 valve, Manapak block and 5 gallon reservoir Note: ll dimensions in mm (inches). 28 arker Hannifin Corporation