Install Cards and Fiber-Optic Cable

Similar documents
Install Cards and Fiber-Optic Cable

Install Cards and Fiber-Optic Cable

Install Cards and Fiber-Optic Cable

Optical Add/Drop Cards

Hardware Specifications

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Small Form-Factor Pluggable (SFP) Module Installation Guide

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

OptEnet OC48 Regenerator Module User Manual

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

Hardware Specifications

DWDM Cards. 6.1 DWDM Card Overview CHAPTER

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Product Operation Manual

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

Perle Fast Ethernet Media Converters

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Single mode 9/125µm, duplex

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

apple Service Source Apple Studio Display 17" LCD (ADC) Updated 6 Decenber Apple Computer, Inc. All rights reserved.

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Hardware Specifications

Perle Fast Ethernet Media Converters

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Hardware Specifications

opengear OPG-1L 50 MHz-2.3 GHz

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

L-Band Fiber Optic Link

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

10Gbps SFP+ Optical Transceiver, 10km Reach

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

CU103 User Manual. Contents

Prisma II Forward Receiver Installation and Operation Guide

Optical Distribution Box 300 Installation Guide. Version : R0.0

SIMATIC NET. Network components Transceiver SFP/SFP+/SCP/STP. Introduction 1. Safety notes 2. Description 3. Assembling 4.

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

Fiber Optic Meter Fiber Optic Source

10G SFP+ Modules. 10G SFP+ Module Series

EDS-G205-1GTXSFP/G308 Series

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

E3/DS3 Fibre Extender

DS3850R0112. FibroLAN broad portfolio of optical transceivers include SFP, SFP+ and XFP series

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

DANGER WARNING CAUTION

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

FB10000 Error Messages Troubleshooting

Job Aid Server and CSS Separation Avaya S8700 Media Server

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

Ordering Information. Industrial Ethernet Solutions

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

Model GS Port Node 1 GHz with 65/86 MHz split

1.2 GHz GS7000 Node RF Split Upgrade Application Note

Fibre Channel Fiber-to-Fiber Media Converters

Hardware Specifications

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Environmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8

Model OTDV Broadcast Transport Links OPERATING MANUAL

Fast Ethernet to Optical Media Converter MCE300T Data Sheet

TeamWork Kits Installation Guide

OPERATION MANUAL INSTALLATION AND KML.F. Fiber Optic Interface Main Link. Kilomux Module. The Access Company

SYNC/VIDEO, SYNC FOR MULTI-TASKER MATRIX SWITCHER USER S GUIDE

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

EDS-210A Series. 8+2G/9+1G-port Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

LambdaFLEX Zero Chirp Tunable XFP Module TL8800ZPCND

Pluggable Transceivers Installation Guide

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

Fibre Optic Modem ODW-622

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

Single Fiber SFP Series

Cisco Network Convergence System 2000 Series Erbium-Doped Raman Amplifiers

TOOLS AND TEST EQUIPMENT REQUIRED

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

10Gb/s 40km DWDM XFP Optical Transceiver

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

Power Injector 1520 Series

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

3M Fiber Optic Wall Mount Enclosure 8430 Series

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Transcription:

CHAPTER 2 Install Cards and Fiber-Optic Cable This chapter explains how to install the Cisco ONS 15454 SDH cards and fiber-optic cable (fiber). Before You Begin This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs). 1. NTP-D15 Install the Common Control Cards, page 2-2 Complete this procedure before installing any other cards. 2. NTP-D16 Install STM-N Cards and Connectors, page 2-7 Complete this procedure as needed. 3. NTP-D17 Install the Electrical Cards, page 2-10 Complete this procedure as needed. 4. NTP-D18 Install Ethernet Cards and Connectors, page 2-11 Complete this procedure as needed. 5. NTP-D286 Install the FC_MR-4 Cards, page 2-12 Complete this procedure as needed. 6. NTP-D348 Install the Filler Cards, page 2-14 Complete this procedure as needed. 7. NTP-D349 Install the Blank Faceplates, page 2-15 Complete this procedure as needed. 8. NTP-D19 Install Fiber-Optic Cables on Optical Cards, page 2-16 Complete this procedure as needed. 9. NTP-D245 Route Fiber-Optic Cables, page 2-19 Complete this procedure as needed. 10. NTP-D227 Remove and Replace a Card, page 2-21 Complete this procedure as needed to remove and replace a card, including deleting the card from Cisco Transport Controller (CTC) and changing an optical card without losing the card s provisioning. 11. NTP-D20 Replace the Front Door, page 2-21 If the front door was removed, complete this procedure to replace the front door and ground strap after installing cards and fiber. Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Filler cards serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards and faceplates are in place. Statement 156 2-1

NTP- D15 Install the Common Control Cards Chapter 2 Install Cards and Fiber-Optic Cable NTP-D15 Install the Common Control Cards Purpose This procedure describes how to install the common control cards. Tools/Equipment Redundant TCC2/TCC2P cards Redundant XC-VXL-2.5G, XC-VXL-10G, or XC-VXC-10G cross-connect cards AIC-I card (optional) Prerequisite Procedures NTP-D13 Perform the Shelf Installation Acceptance Test, page 1-19 Required/As Needed Required Onsite/Remote Onsite Security Level Provisioning or higher During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Caution Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower-right outside to edge of the shelf assembly. If protective clips are installed on the backplane connectors of the cards, remove the clips before installing the cards. If you install a card incorrectly, the FAIL LED flashes continuously. Step 1 If you plan to install XC-VXL-2.5G cards, review Table 2-1 on page 2-3 to determine card/slot compatibility. If you plan to install XC-VXL-10G or XC-VXC-10G cards, review Table 2-2 on page 2-5 to determine card/slot compatibility. Step 2 Complete the DLP-D332 Install the TCC2/TCC2P Cards task on page 20-23. Figure 2-1 shows card installation. 2-2

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D15 Install the Common Control Cards Figure 2-1 Installing Cards in the ONS 15454 SDH FAN FAIL CRIT MAJ MIN 61239 Ejector Guide rail Step 3 Complete the DLP-D333 Install the XC-VXL-10G, XC-VXL-2.5G, or XC-VXC-10G Cards task on page 20-26. If you install the wrong card in a slot, see the NTP-D227 Remove and Replace a Card procedure on page 2-21. Step 4 Complete the DLP-D334 Install the Alarm Interface Controller International Card task on page 20-28, if necessary. In Table 2-1, X indicates that a card is supported in the slot. The multiservice (traffic) slots, Slots 1 to 6 and 12 to 17, include four slots (Slots 5, 6, 12, and 13) that have four times the bandwidth of the other multiservice slots. Table 2-1 ONS 15454 SDH Card and Slot Compatibility for the XC-VXL-2.5G Cards Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Type MS MS MS MS MS MS TCC2/ TCC2P XC 1 AIC-I XC 1. TCC2/ TCC2P MS MS MS MS MS MS TCC2/TCC2P X X XC-VXL-2.5G X X AIC-I X DS3i-N-12 X X X X X X X X X X 2-3

NTP- D15 Install the Common Control Cards Chapter 2 Install Cards and Fiber-Optic Cable Table 2-1 ONS 15454 SDH Card and Slot Compatibility for the XC-VXL-2.5G Cards (continued) Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TCC2/ TCC2/ Type MS MS MS MS MS MS TCC2P XC 1 AIC-I XC 1. TCC2P MS MS MS MS MS MS E1-42 X X X X X X X X E3-12 X X X X X X X X X X STM1E-12 X X X X X X X X E100T-G X X X X X X X X X X X X E1000-2-G X X X X X X X X X X X X G1K-4 X X X X X X X X X X X X ML100T-12 X X X X X X X X X X X X ML1000-2 X X X X X X X X X X X X ML-MR-10 X X X X X X X X X X X X CE-MR-10 X X X X X X X X X X X X CE-100T-8 X X X X X X X X X X X X CE-1000-4 X X X X X X X X X X X X OC3 IR 4/STM1 X X X X X X X X X X X X SH 1310 OC3IR/STM1 X X X X X X X X SH 1310-8 OC12 IR/STM4 X X X X X X X X X X X X SH 1310 OC12 LR/STM4 X X X X X X X X X X X X LH 1310 OC12 LR/STM4 X X X X X X X X X X X X LH 1550 OC12 LR/STM4 X X X X X X X X LH 1310-4 OC12 LR/STM4 X X X X X X X X X X X X LH 1550 OC48 IR/STM16 X X X X X X X X X X X X SH AS 1310 OC48 LR/STM16 LH AS 1550 X X X X X X X X X X X X OC48 ELR/STM16 EH 100 GHz OC192 SR/STM64 IO 1310 X X X X Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. 2-4

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D15 Install the Common Control Cards Table 2-1 ONS 15454 SDH Card and Slot Compatibility for the XC-VXL-2.5G Cards (continued) Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Type MS MS MS MS MS MS OC192 IR/STM64 SH 1550 OC192 LR/STM64 LH 1550 OC192 LR/STM64 LH ITU 15xx.xx Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. FC_MR-4 X X X X X X X X X X X X 15454_MRC-12 2 Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. OC192SR1/ Not supported with XC-VXL-2.5G cards. Requires XC-VXL-10G or XC-VXC-10G cards. STM64IO Short Reach and OC192/STM64 Any Reach 3 1. The term XC is used generically to mean cross-connect card. 2. Designated as MRC-12 in CTC. 3. Designated as STM64-XFP in CTC. TCC2/ TCC2/ TCC2P XC 1 AIC-I XC 1. TCC2P MS MS MS MS MS MS In Table 2-2, X indicates that a card is supported in the slot. The multiservice (traffic) slots, Slots 1 to 6 and 12 to 17, include four slots (Slots 5, 6, 12, and 13) that have four times the bandwidth of the other multiservice slots. Table 2-2 Slot Compatibility for the XC-VXL-10G or XC-VXC-10G Card Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Type MS MS MS MS MS MS TCC2/ TCC2P XC 1 AIC-I XC 1 TCC2/ TCC2P MS MS MS MS MS MS TCC2/TCC2P X X XC-VXL-10G X X XC-VXC-10G X X AIC-I X DS3i-N-12 X X X X X X X X X X E1-42 X X X X X X X X E3-12 X X X X X X X X X X STM1E-12 X X X X X X X X E100T-G X X X X X X X X X X X X E1000-2-G X X X X X X X X X X X X G1K-4 X X X X X X X X X X X X 2-5

NTP- D15 Install the Common Control Cards Chapter 2 Install Cards and Fiber-Optic Cable Table 2-2 Slot Compatibility for the XC-VXL-10G or XC-VXC-10G Card (continued) Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 TCC2/ TCC2/ Type MS MS MS MS MS MS TCC2P XC 1 AIC-I XC 1 TCC2P MS MS MS MS MS MS ML100T-12 X X X X X X X X X X X X ML1000-2 X X X X X X X X X X X X ML-MR-10 X X X X X X X X X X X X CE-MR-10 X X X X X X X X X X X X CE-100T-8 X X X X X X X X X X X X CE-1000-4 X X X X X X X X X X X X OC3 IR 4/STM1 X X X X X X X X X X X X SH 1310 OC3IR/STM1S X X X X X X X X H 1310-8 OC12 IR/STM4 X X X X X X X X X X X X SH 1310 OC12 LR/STM4 X X X X X X X X X X X X LH 1310 OC12 LR/STM4 X X X X X X X X X X X X LH 1550 OC12 LR/STM4 X X X X X X X X LH 1310-4 OC12 LR/STM4 X X X X X X X X X X X X LH 1550 OC48 IR/STM16 X X X X X X X X X X X X SH AS 1310 OC48 LR/STM16 LH AS 1550 X X X X X X X X X X X X OC48 ELR/STM16 EH 100 GHz OC192 SR/STM64 IO 1310 OC192 IR/STM64 SH 1550 OC192 LR/STM64 LH 1550 OC192 LR/STM64 LH ITU 15xx.xx X X X X X X X X X X X X X X X X X X X X X X X X X X X X 2-6

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D16 Install STM-N Cards and Connectors Table 2-2 Slot Compatibility for the XC-VXL-10G or XC-VXC-10G Card (continued) Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Type MS MS MS MS MS MS X X X X OC192SR1/ STM64IO Short Reach and OC192/STM64 Any Reach 2 FC_MR-4 X X X X X X X X X X X X 15454_MRC-12 3 X X X X X X X X X X X X 1. The term XC is used generically to mean cross-connect card. 2. Designated as STM64-XFP in CTC. 3. Designated as MRC-12 in CTC. TCC2/ TCC2/ TCC2P XC 1 AIC-I XC 1 TCC2P MS MS MS MS MS MS Step 5 Continue with the following procedures, as needed: NTP-D16 Install STM-N Cards and Connectors, page 2-7 NTP-D17 Install the Electrical Cards, page 2-10 NTP-D18 Install Ethernet Cards and Connectors, page 2-11 NTP-D286 Install the FC_MR-4 Cards, page 2-12 Stop. You have completed this procedure. NTP-D16 Install STM-N Cards and Connectors Purpose This procedure installs the optical cards (STM-1, STM1-8, STM-4, STM4-4, STM-16, STM-64, and 15454_MRC-12). The MRC-12 (multirate), OC192SR1/STM64IO Short Reach (STM64-XFP Short Reach), and OC192/STM64 Any Reach(STM64-XFP Any Reach) cards require Small Form-factor Pluggables (SFPs/XFPs) to provide the fiber interface to the cards. On all other optical cards, the fiber is plugged directly into the card. Install according to site plan, if available. Tools/Equipment STM-1, STM-4, STM-16, STM-64, and MRC-12 cards (as applicable) Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2 Required/As Needed As needed Onsite/Remote Onsite Security Level None During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 2-7

NTP- D16 Install STM-N Cards and Connectors Chapter 2 Install Cards and Fiber-Optic Cable Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291 Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Statement 1056 The following laser activation warning applies only to STM-64 cards with safety keys: The laser is on when the card is booted and the safety key is in the on position (labeled 1). The port does not have to be in service for the laser to be on. The laser is off when the safety key is off (labeled 0). Statement 293 Caution Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. To simplify subnetwork connection protection (SNCP) to multiplex section-shared protection ring (MS-SPRing) conversion and node addition, install optical cards according to an east (Slots 12 and 13) to west (Slots 5 and 6) configuration. This configuration is not mandatory. If you install a card incorrectly, the FAIL LED flashes continuously. During the boot process, a Locked-enabled, disabled STM-N port will output a line alarm indication signal (AIS-L) to any Unlocked-enabled far-end receivers. See the Cisco ONS 15454 SDH Troubleshooting Guide for further information about the AIS-L condition. Step 1 If you installed XC-VXL-2.5G cards, review Table 2-1 on page 2-3 to determine card/slot compatibility. If you installed XC-VXL-10G or XC-VXC-10G cards, review Table 2-2 on page 2-5 to determine card/slot compatibility. Install higher-capacity cards first; for example, install an STM-64 card before installing an STM-12 card. Let each card completely boot before installing the next card. OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach are the titles that appear on the faceplates of the STM64-XFP cards. In CTC, the cards are abbreviated as STM64-XFP. Before installing a MRC-12 card, review Table 2-3 for bandwidth limitations based on the slot where the card is installed and the type of cross-connect card installed in the shelf. 2-8

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D16 Install STM-N Cards and Connectors Table 2-3 Maximum Bandwidth by Shelf Slot for the MRC-12 in Different Cross-Connect Configurations XC Card Type Maximum Bandwidth in Slots 1 through 4 and 12 through 17 Maximum Bandwidth in Slots 5, 6, 12, or 13 XC-VXL-2.5G OC-48 OC-48 XC-VXC-10G/XC-VXL-10G OC-48 OC-192 Step 2 Step 3 Step 4 Refer to the card s reference section in the Optical Cards chapter of the Cisco ONS 15454 SDH Reference Manual for more information about slot and bandwidth restrictions. Open the card latches/ejectors. Use the latches/ejectors to firmly slide the optical card along the guide rails until the card plugs into the receptacle at the back of the slot. Verify that the card is inserted correctly and close the latches/ejectors on the card. It is possible to close the latches/ejectors when the card is not completely plugged into the backplane. Ensure that you cannot insert the card any further. If you install the wrong card in a slot, complete the NTP-D227 Remove and Replace a Card procedure on page 2-21. Step 5 Verify the LED activity: The red FAIL LED turns on for 20 to 30 seconds. The red FAIL LED blinks for 35 to 45 seconds. All LEDs blink once and turn off for 5 to 10 seconds. The ACT or ACT/STBY LED turns on. The signal fail (SF) LED can persist until all card ports connect to their far-end counterparts and a signal is present. The booting STM-N card will send an AIS-L to the far-end receiver as long as it is Locked-enabled, disabled. Step 6 If the card does not boot up properly, or the LED activity does not mimic Step 5, check the following: When a physical card type does not match the type of card provisioned for that slot in CTC, the card might not boot. If an optical card does not boot, open CTC and verify that the slot is not provisioned for a different card type before assuming the card is faulty. If the red FAIL LED does not turn on, check the power. If you insert a card into a slot provisioned for a different card, all LEDs turn off. If the red FAIL LED is illuminated continuously or the LEDs behave erratically, the card is not installed properly. Remove the card and repeat Steps 2 to 5. 2-9

NTP- D17 Install the Electrical Cards Chapter 2 Install Cards and Fiber-Optic Cable Step 7 The MRC-12 card requires SFPs and the STM64-XFP cards require XFPs to provide a fiber interface. If you installed any of these cards, complete the DLP-D335 Install GBIC or SFP/XFP Devices task on page 20-29 or preprovision the SFP/XFP using the DLP-D107 Preprovision an SFP or XFP Device task on page 18-8. Step 8 Continue with the NTP-D19 Install Fiber-Optic Cables on Optical Cards procedure on page 2-16. Stop. You have completed this procedure. NTP-D17 Install the Electrical Cards Purpose This procedure installs the electrical cards (DS3i-N-12, E1-42, E3-12, and STM1E-12). Tools/Equipment Electrical cards Prerequisite Procedures NTP-D220 Install the Power and Signal FMECs, page 1-7 NTP-D15 Install the Common Control Cards, page 2-2 Required/As Needed As needed Onsite/Remote Onsite Security Level None During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 The E3-12 card can be deployed in a central office or a carrier s exchange. Install higher-capacity cards first; for example, install an E3-12 card before installing an E1-14 card. Let each card boot completely before installing the next card. Cisco recommends installing STM-N, transponder (TXP), and muxponder (MXP) cards before you install electrical cards, as applicable. Step 1 Step 2 Step 3 If you installed XC-VXL-2.5G cards, review Table 2-1 on page 2-3 to determine card/slot compatibility. If you installed XC-VXL-10G or XC-VXC-10G cards, review Table 2-2 on page 2-5 to determine card/slot compatibility. Open the card latches/ejectors. Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the receptacle at the back of the slot. If you install the wrong card in a slot, complete the NTP-D227 Remove and Replace a Card procedure on page 2-21. 2-10

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D18 Install Ethernet Cards and Connectors Step 4 Verify that the card is inserted correctly and close the latches/ejectors on the card. It is possible to close the latches/ejectors when the card is not completely plugged into the backplane. Ensure that you cannot insert the card any further. Step 5 Verify the LED activity: The red FAIL LED turns on for 10 to 15 seconds. If the red FAIL LED does not turn on, check the power. The red FAIL LED blinks for 30 to 40 seconds. All LEDs blink once and turn off for 1 to 5 seconds. The ACT or ACT/STBY LED turns on. The SF LED can persist until all card ports connect to their far end counterparts and a signal is present. If you insert a card into a slot provisioned for a different card, all LEDs turn off. If the red FAIL LED is on continuously or the LEDs behave erratically, the card is not installed properly. Remove the card and repeat Steps 2 to 5. Step 6 Continue with the NTP-D18 Install Ethernet Cards and Connectors procedure on page 2-11 if necessary. Stop. You have completed this procedure. NTP-D18 Install Ethernet Cards and Connectors Purpose This procedure installs the Ethernet cards (E100T-G, E1000-2-G, G1K4, ML100T-12, ML1000-2, ML100X-8, ML-MR-10, CE-100T-8, CE-1000-4, and CE-MR-10). Tools/Equipment Ethernet cards Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2 Required/As Needed As needed Onsite/Remote Onsite Security Level None During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291 2-11

NTP- D286 Install the FC_MR-4 Cards Chapter 2 Install Cards and Fiber-Optic Cable Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Statement 1056 To comply with the Telcordia GR-1089 Network Equipment Building Systems (NEBS) standard for electromagnetic compatibility and safety, connect the copper Ethernet ports to intrabuilding or nonexposed wiring and cabling only. Caution Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. Cisco recommends installing TXP, MXP, STM-N, and electrical cards before you install Ethernet cards, as applicable. Step 1 Step 2 Step 3 If you installed XC-VXL-2.5G cards, review Table 2-1 on page 2-3 to determine card/slot compatibility. If you installed XC-VXL-10G or XC-VXC-10G cards, review Table 2-2 on page 2-5 to determine card/slot compatibility. Complete the DLP-D39 Install Ethernet Cards task on page 17-30. Allow each card to boot completely before installing the next card. Complete the DLP-D335 Install GBIC or SFP/XFP Devices task on page 20-29 if you are using E1000-2-G, G1K-4, ML1000-2, ML100X-8, ML-MR-10, CE-1000-4, or CE-MR-10 cards. If you need to remove a Gigabit Interface Converter (GBIC) or SFP/XFP, complete the DLP-D336 Remove GBIC or SFP/XFP Device task on page 20-32. Step 4 Continue with NTP-D286 Install the FC_MR-4 Cards procedure on page 2-12 if necessary. Stop. You have completed this procedure. NTP-D286 Install the FC_MR-4 Cards Purpose This procedure installs the FC_MR-4 card, also known as the Fibre Channel card. Tools/Equipment FC_MR-4 card(s) Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2 Required/As Needed As needed Onsite/Remote Onsite Security Level None 2-12

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D286 Install the FC_MR-4 Cards During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291 Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Statement 1056 Caution Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. If protective clips are installed on the backplane connectors of the cards, remove the clips before installing the cards. High-performance devices on this card can get hot during operation. To remove the card, hold it by the faceplate and bottom edge. Allow the card to cool before touching any other part of it or before placing it in an antistatic bag. Statement 201 Step 1 Step 2 Step 3 Step 4 If you installed XC-VXL-2.5G cards, review Table 2-1 on page 2-3 to determine card/slot compatibility. If you installed XC-VXL-10G or XC-VXC-10G cards, review Table 2-2 on page 2-5 to determine card/slot compatibility. Open the card latches/ejectors. Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the receptacle at the back of the slot. Verify that the card is inserted correctly and close the latches/ejectors on the card. It is possible to close the latches/ejectors when the card is not completely plugged into the backplane. Ensure that you cannot insert the card any further. If you install the wrong card in a slot, complete the NTP-D227 Remove and Replace a Card procedure on page 2-21 and install the correct card. Step 5 Verify the LED activity: The red FAIL LED turns on for 20 to 30 seconds. The ACT LED is amber for 3 to 5 seconds. The red FAIL LED blinks for up to 2 minutes. The FAIL and ACT LEDs blink once and turn off for 1 to 5 seconds. 2-13

NTP- D348 Install the Filler Cards Chapter 2 Install Cards and Fiber-Optic Cable The ACT LED illuminates green. If the red FAIL LED does not turn on, check the power. If you insert a card into a slot provisioned for a different card, all LEDs turn off. Step 6 Complete the DLP-D335 Install GBIC or SFP/XFP Devices task on page 20-29 to install GBICs on the FC_MR-4 card. If you need to remove a GBIC or SFP/XFP, complete the DLP-D336 Remove GBIC or SFP/XFP Device task on page 20-32. Step 7 Continue with the NTP-D19 Install Fiber-Optic Cables on Optical Cards procedure on page 2-16. Stop. You have completed this procedure. NTP-D348 Install the Filler Cards Purpose This procedure explains how to install the filler cards in any unused traffic or AIC-I card slots (Slots 1 through 6, 9, and 12 through 17). A filler card consists of a card with a faceplate attached. There is no label on the faceplate and the filler card is not detectable by CTC. Filler cards aid in maintaining proper air flow and electromagnetic interference (EMI) requirements. Tools/Equipment Filler cards (Cisco P/N 15454E-BLANK) Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2 NTP-D16 Install STM-N Cards and Connectors, page 2-7 NTP-D17 Install the Electrical Cards, page 2-10 NTP-D18 Install Ethernet Cards and Connectors, page 2-11 NTP-D286 Install the FC_MR-4 Cards, page 2-12 Required/As Needed As needed Onsite/Remote Onsite Security Level None Filler cards serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain EMI that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards and faceplates are in place. Statement 156 2-14

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D349 Install the Blank Faceplates Caution Always use the supplied ESD wristband when working with a powered ONS 15454_SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded. Step 1 Step 2 Step 3 Step 4 Open the card ejectors. Slide the card along the guide rails into the correct slot. Close the ejectors. Repeat for any remaining unused card slots. Stop. You have completed this procedure. NTP-D349 Install the Blank Faceplates Purpose This procedure explains how to install the blank faceplates in any unused FMEC slot. A blank faceplate card is a sheet metal cover that is used to block any unused FMEC slot. The blank faceplate aids in maintaining proper air flow and EMI requirements. Tools/Equipment Screwdriver Blank faceplate cards (Cisco P/N 15454E-BLANK-FMEC) Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2 NTP-D16 Install STM-N Cards and Connectors, page 2-7 NTP-D17 Install the Electrical Cards, page 2-10 NTP-D18 Install Ethernet Cards and Connectors, page 2-11 NTP-D286 Install the FC_MR-4 Cards, page 2-12 NTP-D348 Install the Filler Cards, page 2-14 Required/As Needed As needed Onsite/Remote Onsite Security Level None Blank faceplates serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain EMI that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards and faceplates are in place. Statement 1029 Caution Always use the supplied ESD wristband when working with a powered ONS 15454_SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded. 2-15

NTP- D19 Install Fiber-Optic Cables on Optical Cards Chapter 2 Install Cards and Fiber-Optic Cable Step 1 Step 2 With screws, attach the blank faceplate so that it covers the empty unused FMEC slot. Repeat for any remaining unused FMEC slots. Stop. You have completed this procedure. NTP-D19 Install Fiber-Optic Cables on Optical Cards Purpose This procedure describes how to install fiber-optic cables on optical cards. Tools/Equipment Fiber-optic cables Fiber boot Prerequisite Procedures NTP-D16 Install STM-N Cards and Connectors, page 2-7 Required/As Needed As needed Onsite/Remote Onsite Security Level None Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products. Statement 291 Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Statement 1056 The following warning applies only to STM-64 cards with safety keys: The laser is on when the card is booted and the safety key is in the on position (labeled 1). The port does not have to be in service for the laser to be on. The laser is off when the safety key is off (labeled 0). Statement 293 Caution Do not use fiber loopbacks with the STM64 LH 1550 or STM64 LH ITU 15xx.xx card unless you are using a 20-dB attentuator. Never connect a direct fiber loopback. Using fiber loopbacks causes irreparable damage to the STM64 LH 1550 or STM64 LH ITU 15xx.xx card. Caution Do not use fiber loopbacks with the STM64 SH 1550 card unless you are using a 5-dB attentuator. Never connect a direct, unattenuated fiber loopback. Using unattenuated fiber loopbacks causes irreparable damage to the STM64 SH 1550 card. Caution Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly. 2-16

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D19 Install Fiber-Optic Cables on Optical Cards You can install the fiber immediately after installing the cards, or wait until you are ready to turn up the network. See Chapter 5, Turn Up a Network. To install fiber-optic cables on Ethernet cards, FC_MR-4 cards, MRC-12 cards, or STM64-XFP cards, see the DLP-D335 Install GBIC or SFP/XFP Devices task on page 20-29. Step 1 Test the optical receive levels for the cards installed and attenuate accordingly. Table 2-4 provides the minimum and maximum levels. The levels for the 15454_MRC-12, OC192SR1/STM64IO Short Reach, and OC192/STM64 Any Reach (OC192-XFP) cards are dependent on the particular SFP/XFP installed in a port. The SFPs/XFPs are shown in parentheses in Table 2-4 for these cards. Table 2-4 Optical Card Transmit and Receive Levels Transmit Receive Card Minimum Maximum Minimum Maximum OC3 IR 4/STM1 SH 1310 15 dbm 8 dbm 28 dbm 8 dbm OC3IR/STM1SH 1310-8 15 dbm 8 dbm 28 dbm 8 dbm OC12 IR/STM4 SH 1310 15 dbm 8 dbm 28 dbm 8 dbm OC12 LR/STM4 LH 1310 3 dbm +2 dbm 28 dbm 8 dbm OC12 LR/STM4 LH 1550 3 dbm +2 dbm 28 dbm 8 dbm OC12 IR/STM4 SH 1310-4 15 dbm 8 dbm 30 dbm 8 dbm OC48 IR/STM16 SH AS 1310 5 dbm 0 dbm 18 dbm 0 dbm OC48 LR/STM16 LH AS 1550 2 dbm +3 dbm 28 dbm 8 dbm OC48 ELR/STM16 EH 100 GHz 2 dbm 0 dbm 27 dbm at 9 dbm 1E-12 BER OC192 SR/STM64 IO 1310 6 dbm 1 dbm 11 dbm 1 dbm OC192 IR/STM64 SH 1550 1 dbm +2 dbm 14 dbm 1 dbm OC192 LR/STM64 LH 1550 +7 dbm +10 dbm 19 dbm 10 dbm OC192 LR/STM64 LH ITU 15xx.xx +3 dbm +6 dbm 22 dbm 9 dbm 15454_MRC-12 1 (ONS-SI-2G-S1) 10 dbm 3 dbm 18 dbm 3 dbm 15454_MRC-12 1 (ONS-SI-2G-I1) 5 dbm 0 dbm 18 dbm 0 dbm 15454_MRC-12 1 (ONS-SI-2G-L1) 2 dbm 3 dbm 27 dbm 9 dbm 15454_MRC-12 1 (ONS-SI-2G-L2) 2 dbm 3 dbm 28 dbm 9 dbm 15454_MRC-12 1 (ONS-SC-2G-30.3 0 dbm 4 dbm 28 dbm 9 dbm through ONS-SC-2G-60.6) 15454_MRC-12 1 (ONS-SI-622-I1) 15 dbm 8 dbm 28 dbm 8 dbm 15454_MRC-12 1 (ONS-SI-622-L1) 3 dbm 2 dbm 28 dbm 8 dbm 2-17

NTP- D19 Install Fiber-Optic Cables on Optical Cards Chapter 2 Install Cards and Fiber-Optic Cable Table 2-4 Optical Card Transmit and Receive Levels (continued) Card 15454_MRC-12 1 (ONS-SI-622-L2) 3 dbm 2 dbm 28 dbm 8 dbm 15454_MRC-12 1 (ONS-SE-622-1470 0 dbm 5 dbm 28 dbm 3 dbm through ONS-SE-622-1610) 15454_MRC-12 1 (ONS-SI-155-I1) 15 dbm 8 dbm 30 dbm 8 dbm 15454_MRC-12 1 (ONS-SI-155-L1) 5 dbm 0 dbm 34 dbm 10 dbm 15454_MRC-12 1 (ONS-SI-155-L2) 5 dbm 0 dbm 34 dbm 10 dbm 15454_MRC-12 1 (ONS-SE-155-1470 0 dbm 5 dbm 34 dbm 3 dbm through ONS-SE-155-1610) 15454_MRC_12 1 9 dbm 14 dbm 14 dbm 5 dbm ONS-SI-155-I1-MM= 15454_MRC_12 1 9 dbm 14 dbm 14 dbm 5 dbm ONS-SI-622-I1-MM= 15454_MRC_12 1 ONS-SC-Z3-1470 through ONS-SC-Z3-1610 0 dbm 5 dbm 9 dbm +5 dbm 15454_MRC_12 1 ONS-SE-Z1= OC192SR1/STM64IO Short Reach 2 (ONS-XC-10G-S1) OC192/STM64 Any Reach 2 (ONS-XC-10G-S1) OC192/STM64 Any Reach 2 (ONS-XC-10G-I2) OC192/STM64 Any Reach 2 (ONS-XC-10G-L2) 1. Designated as MRC-12 in CTC 2. Designated as STM64-XFP in CTC Transmit Receive Minimum Maximum Minimum Maximum 5 dbm 0 dbm 10 dbm 0 dbm 18 dbm 0 dbm 0 dbm 23 dbm (OC-3) 23 dbm (OC-12) 0 dbm (OC-48) 21 dbm (FC) 22 dbm (GE) 6 dbm 1 dbm 11 dbm 1 dbm 6 dbm 1 dbm 11 dbm 1 dbm 1 dbm 2 dbm 14 dbm 2 dbm 0 dbm 4 dbm 24 dbm 7dBm Step 2 Inspect and clean all fiber connectors thoroughly. See the NTP-D112 Clean Fiber Connectors procedure on page 15-15 for instructions. Dust particles can degrade performance. Put caps on any fiber connectors that are not used. Step 3 As needed, complete the DLP-D42 Install Fiber-Optic Cables on an LGX Interface task on page 17-31. Step 4 As needed, complete the DLP-D22 Install Fiber-Optic Cables in a 1+1 Configuration task on page 17-17. 2-18

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D245 Route Fiber-Optic Cables Step 5 Step 6 As needed, complete the DLP-D337 Install Fiber-Optic Cables for SNCP Configurations task on page 20-33. As needed, complete the DLP-D338 Install Fiber-Optic Cables for MS-SPRing Configurations task on page 20-36. Step 7 Continue with the NTP-D245 Route Fiber-Optic Cables procedure on page 2-19. Stop. You have completed this procedure. NTP-D245 Route Fiber-Optic Cables Purpose This procedure routes fiber-optic cables. Tools/Equipment None Prerequisite Procedures NTP-D19 Install Fiber-Optic Cables on Optical Cards, page 2-16 NTP-D286 Install the FC_MR-4 Cards, page 2-12 Required/As Needed As needed Onsite/Remote Onsite Security Level None Step 1 As needed, complete the DLP-D45 Install the Fiber Boot task on page 17-33. Fiber boots are required for all STM-N cards except the STM-64, OC192SR1/STM64IO Short Reach, OC192/STM64 Any Reach (STM64-XFP), and STM-16 AS cards. Step 2 Open the fold-down front door on the cable-management tray (Figure 2-2). Figure 2-2 Fold-Down Front Door of the Cable-Management Tray FAN FAIL CRIT MAJ MIN 78100 Step 3 Route the fiber cable on the card faceplate through the fiber clip on the faceplate (Figure 2-3). Fiber clips are factory-attached to the faceplate of the STM-N cards. 2-19

NTP- D245 Route Fiber-Optic Cables Chapter 2 Install Cards and Fiber-Optic Cable Step 4 If you installed a 15454_MRC-12 card, complete the DLP-D104 Install the Fiber Clip on MRC Cards task on page 18-3. The 15454_MRC-12 cards are shipped with two versions of a fiber clip that plug into the faceplate. The clip must be selected according to the cabinet door depth. Use the short clip with the standard door and the long clip with the extended door. GBICs, SFPs, and XFPs do not have fiber clips; therefore, if you are routing optical cable from an FC_MR-4, E1000-2-G, G1K-4, ML1000-2, or STM64-XFP cards, skip to Step 5. Figure 2-3 Routing Fiber-Optic Cables on the Optical-Card Faceplate Faceplate connector FAIL ACT SF Cable connector Tx Rx Retaining clip Slot on cable management tray 61238 Fold down faceplate Cutout Step 5 Route the fiber cables into the cable-management tray (Figure 2-3). Step 6 Step 7 Route the fiber cables out either side of the cable-management tray through the cutouts on each side of the shelf assembly. Use the reversible fiber guides to route cables out the desired side. Close the fold-down front door when all fiber cables in the front compartment are properly routed. Stop. You have completed this procedure. 2-20

Chapter 2 Install Cards and Fiber-Optic Cable NTP- D227 Remove and Replace a Card NTP-D227 Remove and Replace a Card Purpose This procedure removes and replaces cards in the ONS 15454 SDH shelf. Tools/Equipment None Prerequisite Procedures DLP-D60 Log into CTC, page 17-44 Required/As Needed As needed Onsite/Remote Onsite Security Level Provisioning or higher Step 1 If you are not logged into CTC and you need to remove a card, remove the card as described in Step 3. When you log into CTC, troubleshoot the mismatched equipment alarm (MEA) using the Cisco ONS 15454 SDH Troubleshooting Guide. Step 2 Step 3 Step 4 Step 5 If you are logged into CTC, complete one of the following: Complete the DLP-D191 Delete a Card task on page 18-77 and continue with Step 3. Complete the DLP-D247 Change an STM-N Card task on page 19-54 to delete a card and replace it with a different optical card while maintaining existing provisioning. Physically remove the card: a. Open the card latches/ejectors. b. Use the latches/ejectors to pull the card forward and away from the shelf. Insert the new card using one of the following procedures as applicable: NTP-D15 Install the Common Control Cards, page 2-2 NTP-D16 Install STM-N Cards and Connectors, page 2-7 NTP-D17 Install the Electrical Cards, page 2-10 NTP-D18 Install Ethernet Cards and Connectors, page 2-11 NTP-D286 Install the FC_MR-4 Cards, page 2-12 As needed, continue with the NTP-D19 Install Fiber-Optic Cables on Optical Cards procedure on page 2-16. Stop. You have completed this procedure. NTP-D20 Replace the Front Door Purpose This procedure replaces the front door and door ground strap after installing cards and fiber-optic cables. Tools/Equipment Pinned hex key Prerequisite Procedures NTP-D3 Open and Remove the Front Door, page 1-6 Required/As Needed Required Onsite/Remote Onsite Security Level None 2-21

NTP- D20 Replace the Front Door Chapter 2 Install Cards and Fiber-Optic Cable Be careful not to crimp any fiber cables that are connected to the STM-N cards or DWDM cards. Some might not have the fiber boot attached. Step 1 Insert the front door into the hinges on the shelf assembly. Step 2 Attach the pluggable ground wire (Figure 2-4). Figure 2-4 ONS 15454 SDH Front Door with Hinges and Ground Wire FAN FAIL CRIT MAJ MIN 61237 Translucent circles for LED viewing Door hinge Assembly hinge pin Assembly hinge Step 3 Swing the door closed. The ONS 15454 SDH comes with a pinned hex key tool for locking and unlocking the front door. Turn the key counterclockwise to unlock the door and clockwise to lock it. Stop. You have completed this procedure. 2-22