Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Similar documents
Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KT 170 Cooling incubators with thermoelectric cooling

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Forced Convection Laboratory Ovens

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Product Data Sheet 4650 N-465

Product Data Sheet 8506 VW-691

ULTRALOW TEMPERATURE FREEZERS -86 C

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

Product Data Sheet 4656 EZ

Hybrid Chart Recorder 250 mm (10")

Label Applicator HERMA 400

Magnetic Stirrers Magnetic Stirr

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Product Data Sheet 4656 ZW

IPS 2400 SMAVIA Appliance for up to 24 IP Channels, 8 3.5" HDD, 3 HU

DMP 331i / DMP 333i LMP 331 i

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Process Transmitter RMA 422

Linear encoders without bearings incremental System for linear motion feedback

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Dissolved Oxygen Transmitter

Optical Cryostat - Omniplex TM

Roof-mounted Blue e+ cooling unit Integration solution VX25

SIMATRIX NEO V2 Modular Video Matrix

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Electrical connection

120cm (4x36 Watt) incl. Splitter Instruction Manual

Frequency Converter Fv

Gamma instabus. Technical product information

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Sensor technologies Proximity sensors Series ST4. Brochure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

LUNERA SERIES L7 _ GEN 3

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

USER MANUAL Table of Contents

P P S - M W S C A N 1 H

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

CTC Series. Compact Temperature Calibrator

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Up to 85% higher Service Life due to efficient sealing method.

Panel-mounting thermostats, type series EM

Dissolved Oxygen Transmitter

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

RMA42. Technical Information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Single Point Flow Monitor SW118 SW119

XPert Filtered Balance Systems

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

IKA Analytical line Calorimeters C 2000

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

APPLICATIONS. Automatic warehouse. Trasportation lines

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

New Eppendorf Freezers Sample security meets the latest in energy efficiency. Stay Cool. CryoCube ULT Freezers: Efficiency has a new name

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Assembly. Front view. LEDs. Parametrization interface. Power Bus

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

STERILISATION Simple solutions made to measure

PROPORTIONAL VALVES Sentronic plus

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Portable Filter Cart Type SPFC

TABLE OF CONTENTS. Instructions:

COMBINATION UNITS MARCH 2018

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

Transcription:

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating even for chambers under full loads. BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior independent of sample size and quantity Outstanding thermal insulation saves operation costs Advanced programming options Model 240 Model 240 MAIN FEATURES Temperature range: room temperature plus 5 C to 300 C APT.line preheating chamber technology Adjustable fan speed Adjustable exhaust air flap Controller with time-segment and real-time programming 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm Computer interface: RS 422 ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model FP 240 8.5 230 V 1 ph 50/60 Hz Standard FP240-230V 9010-0263 208 V 1 ph 60 Hz Standard FP240UL-208V 9010-0264 Page 1 / 6

TECHNICAL DATA Description FP240-230V 1 FP240UL-208V 1 Article Number 9010-0263 9010-0264 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 Temperature variation at 150 C 2 ± K 2 ± K Temperature fluctuation at 150 C [± K] 0.3 0.3 Heating-up time to 150 C [min] 27 27 Recovery time after 30 seconds door open at 150 C [min] 10 10 Air change data Air change (approx.) at 150 C [x/h] 20 20 Electrical data Rated Voltage [V] 230 208 Power frequency [Hz] 50/60 60 Nominal power [kw] 2.7 2.7 Unit fuse [A] 16 3 x 16 Phase (Nominal voltage) [ph] 1 1 Measures - Outer dimensions Width net [in] 40.8 40.8 Height net [in] 32.5 32.5 Depth net [in] 29.35 29.35 Wall clearance back [in] 6.3 6.3 Wall clearance sidewise [in] 3.94 3.94 Measures - Internal Dimensions Width [in] 31.52 31.52 Height [in] 23.64 23.64 Depth [in] 20.09 20.09 Measures Interior volume [cu.ft.] 8.5 8.5 Net weight of the unit (empty) [lbs] 212 212 permitted load [lbs] 154 154 Load per rack [lbs] 66 66 Environment-specific data Energy consumption at 150 C 850 Wh/h 850 Wh/h Fixtures Number of shelves (std./max.) 2/7 2/7 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 2 / 6

OPTIONS AND ACCESSORIES Access port with silicone plug Analog output, 4 20 ma Calibration certificate, expanded Calibration certificate, temperature back left 10 mm 01 8012-1286 30 mm 01 8012-1370 50 mm 01 8012-1386 10 mm 01 8012-1279 30 mm 01 8012-1362 50 mm 01 8012-1378 100 mm 01, 11 8012-1510 right top 10 mm 01 8012-1272 30 mm 01 8012-1357 50 mm 01 8012-1374 100 mm 01, 11 8012-1507 10 mm 01 8012-1265 30 mm 01 8012-1366 50 mm 01 8012-1382 100 mm 01, 10 8012-1389 for temperature values (output not adjustable) 02 8012-0481 for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1119 for temperature, measurement in center of chamber at specified temperature 8012-1138 temperature measurement incl. certificate and 27 measuring points at specified temperature 8012-1597 temperature measurement incl. certificate, 15-18 measuring points at specified temperature 8012-1576 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-1555 Cart Cart stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm 9051-0019 Class 3.1 independent temperature safety device Data Logger Kit Data Logger Software with visual alarm (DIN 12880) 04, 12 8012-1149 T 350: For continuous temperature logging from 0 C to 350 C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0714 19 8012-0821 Door gasket made of FKM, silicone-free 03 8012-0496 Door lock lockable door handle 8012-1255 Fan, reinforced to increase air change rates 208 V option model 8012-0244 230 V option model 8012-0199 HEPA air filter On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) 8012-1169 Inner chamber, reinforced Instrument tray including 2 reinforced racks (max. total load 250 kg, max. load per rack 70 kg) 8012-0338 with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm small 4022-0123 with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm large 4022-0124 Page 3 / 6

RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 Interface converter 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 Interface converter, USB / RS422 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) 8012-0665 Measurement of air exchange rate in accordance with ASTM D5374, definition and protocol according to ambient temperature 8012-1198 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor Rack additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-0504 chrome plated 6004-0004 stainless steel 6004-0009 Rack accessories Rack accessories fasteners (1 set of 4) for additional security of racks 8012-0531 Rack, reinforced stainless steel, with 1 set of 4 fasteners, max. load 70 kg 8012-0345 RS 422 interface modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Rubber pads set of 4 anti-slip feet, for safe stacking of unit 10 8012-0001 Shelf, perforated stainless steel 6004-0031 APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Viewing window and interior lighting Zero voltage relay contacts viewing window in each door, 350 x 240 mm, and 30 W interior lighting 120 V option model 8012-0239 230 V option model 8012-0058 for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A) 120 V option model 8012-0472 230 V option model 8012-0471 SERVICES Installation services Data Logger Kit installation service unit function instructions for operation and programming of the controller 18 DL100500 Installation and set up of unit at operating location, connect to existing connections 13, 18 DL100100 Preventive maintenance Preventive maintenance Execution of equipment inspection according to maintenance plan 14, 18 DL200200 Calibration services Data Logger Kit calibration service including certificate, one measuring point in center of chamber at specified temperature DL300101 Measurement of air exchange rate including certificate (in accordance with ASTM D5374) DL330000 Page 4 / 6

Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature DL300118 Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature DL300127 Temperature measurement 9 measuring points including certificate, 9 measuring points at specified temperature DL300109 Validation services Data Logger Kit validation service in accordance with qualification folder 15, 18, 20 DL410200 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL440500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0856 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0945 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL005041 beginning with the date of delivery, wearing parts are not included DL005042 Page 5 / 6

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract (see the chapter on BINDER Service) to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for both items. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 6 / 6