User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Similar documents
User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

User Manual M1 - tricolour

User Manual M1 - tricolour

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Standard signal metering in wall-mounting case

48x24. Options ORDER NUMBER OF TYPE PFL B

Users guide for PB units Interface unit, 4- or 6-digit

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Users guide MG-XB. Interface unit digit. Panel instrument type MG-BB Construction instrument type MG-AB

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

MT03A Electronic converter for flow rate transmitters

User manual M2-1F. Technical features:

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

RMA42. Technical Information

Operating Instructions

Electronic converter for level transmitters MT03L Instructions manual

Standard RS232 RS ma

Technical Information RIA45

Operating instructions Electronic preset counter Type series 717

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

SCREEN RECORDER KD8 TYPE

MICROMASTER Encoder Module

Panel-mounting thermostats, type series EM

Hybrid Chart Recorder 250 mm (10")

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DCP100 Digital Control Programmer Specifications

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Gamma instabus. Technical product information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

C200H-AD002/DA002 Analog I/O Units Operation Guide

TASKI Service Tool Edition: V5.10/2014

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Set Point Controller OC557. Operator s Manual

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Model IQ4-PC User Manual Revision Date:

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

MULTIS L72. Operating instructions

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Instruction Manual NivuLog 2 Ex / NivuLog 4 / NivuLog PCM Ex

FOREST SHUTTLE S / L / M RECEIVER

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

263 Series LED Bargraph Indicator and Controllers

Installing the FOREST SHUTTLE S / L

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

K3NX Process Meter OPERATION MANUAL

LCD Thermometer / Clock S No. 1253

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Operating Instructions

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

REGO Start&Go USER MANUAL

INSTALLATION & USER GUIDE

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

02/11/2015

EG4015. Digital Generator Governor Controller User Manual

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

800 Displaying Series Flowmeter

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

TRF STEP-DOWN TRANSFORMER USER MANUAL

Multifunction Digital Timer

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Micro-DCI 53ML5100 Manual Loader

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

EB 3000 as of Version 1.7

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Type AKS 4100/4100U Coaxial D14 version

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Safety Light Curtain C 4000

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Light Curtain Type LA

Panel-Mounted Thermostat

SIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.

T775U Series 2000 Electronic Stand-Alone Controller

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Self--powered Time Counter

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Process Transmitter RMA 422

GC30 Digital Differential Pressure Gauge Operation Manual

Transcription:

User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: from 63 mm with plug-in terminal adjustment via facry default or directly on the sensor signal min-/max-value recording display of C or F possible display flashing at threshold exceedance or undershooting impedance matching programming interlock via access code protection class IP65 plug-in screw terminal pc-based configuration software PM-TOOL for devices without keypad, for a simple adjustment of standard devices M1_3TGB.pdf Stand: 28.10.2011 96x24

Identification STANDARD TYPES Thermocouple Housing size: 96x24 mm ORDER NUMBER M1-3TR4B.040x.570AD M1-3TR4B.040x.770AD Options breakdown of order code: M 1-3 T R 4 B. 0 4 0 X. 7 7 0 A D Basic type M-Line Dimension D physical unit Installation depth 74 mm 1 Version incl. plug-in terminal A Standard B Installation depth 63 mm Housing size only with 24 VDC supply 96x24x60 mm 3 (without plug terminal) Setpoints 0 not setpoints Display type Temperature T Protection class 1 without keypad, Display colours operation on the back Blue B 7 IP65 / plug-in terminal Green G Red R Supply voltage Orange Y 5 230 VAC 7 24 VDC galv.insulated Number of digits 4-digit 4 Measuring input X Type K,B,S,N,E,T,R,L,J Digit height selectable 14 mm B Analog output 0 without Interface without 0 Temperature device 4 Thermocouple Please state physical unit by order, e.g. F.

Contents 1. Assembly 2 2. Electrical connection 3 3. Function and operation description 4 4. Setting up the device 5 4.1. Switching on 5 4.2. Standard parameterization 5 4.3. Extended parameterization 7 4.3.1. Min/Max value inquiry tast 7 4.3.2. Flashing of display Flas 7 4.3.3. Threshold values LI-1 LI-2 7 5. Facry settings 10 5.1. Default values 10 5.2. Reset default settings 10 6. Technical data 11 7. Safety advice 13 8. Error elimination 14 1

1. Assembly 1. Assembly Please read the Safety advice on page 13 before installation and keep this user manual for future reference. 3,0 24,0 Sealing 96,0 Gap for physical unit 74,0 134,0 Installation depth incl. plug-in terminal 1. After removing the fixing elements, insert the device. 2. Check the seal make sure it fits securely. 3. Click the fixing elements back in place and tighten the clamping screws by hand. Then use a screwdriver tighten them another half a turn. CAUTION! The rque should not exceed 0.1 Nm! The dimension symbols can be exchanged before installation via a channel on the side! 2

2. Electrical connection 2. Electrical connection Advice: The galvanic insulation in devices with temperature sensors that do not have a galvanic connection an extrinsic potential, can be cancelled by an bridge from terminal 3 4 and thus stabilise the device against external failures. 3

3. Function and operation descirption 3. Function and operation description Operation The operation is divided in two different levels. Menu Level Here it is possible navigate between the individual menu items. Parameterization level: The parameters sred in the menu item can be parameterized here. Functions that can be adjusted or changed are always indicated with a flashing of the display. Adjustments made at the parameterization level should be always confirmed by pressing the [P] key save them. However, the display aumatically saves all adjustments and then switches operation mode if no further keys are pressed within 10 seconds. Level Menu level Parameterization level Butn Description Change parameterization level with the relevant parameters For navigation at the menu level To confirm the changes made at the parameterization level To change the value or setting Example: Menu level Parameterization level Programming via configuration software PM-TOOL-MUSB6 You receive the software on CD incl. an USB-cable with a device adapr. The connection is done via a 6-pole micromatch connecr plug on the back and the PC is connected via an USB connecr plug. System requirements: PC with USB interface Software: Windows XP, Windows Vista 4

4. Setting up the device 4. Setting up the device 4.1. Switching on Once the installation is complete, you can start the device by applying the current loop. Check beforehand once again that all the electrical connections are correct. Starting sequence For 1 second during the switching-on process, the segment test (8 8 8 8) is displayed, followed by an indication of the software type and, after that, also for 1 second, the software version. After the start-up sequence, the device switches operation/display mode. 4.2. Standard parameterization: To be able parameterize the display, press the [P] key in operating mode for 1 second. The display then changes the menu level with the first menu item TYPE. Menu level Parameterization level Type of temperature measurement, DISP: The temperature can be displayed in C or in F. Confirm the selection with [P] and the display switches back menu level. Selection of the thermocouple, TYPE: As input versions there are 9 thermocouple types (L, J, K, B, S, N, E, T, R) choose from. Set the end value from the smallest the highest digit with [ ] [ ] and confirm each digit with [P]. Setting the decimal point, offs: The decimal point on the display and the physical unit can be moved with [ ] [ ]. If e.g. temperature measurement in C is selected, then you can choose between 0 C and 0.0 C in the parameterization level. Confirm with [P], the display then switches back the menu level again. 5

4. Setting up the device Menu level Parameterization level Impedance matching, dot: The value for the sensor calibration is from the smallest the highest digit selectable with [ ] [ ] and confirmed with [P]. After the last digit the display switches back the menu level again. The value calibration for a temperature measurement in C can be adjusted between -20.0 and +20.0 and in F between -36.0 and +36.0. If the type of the measurement is changed later, then the value is rounded. Setting the display time, SEC: then The display time is set with [ ] [ ]. The display moves up in increments of 0.1 sec up 1 second and in increments of 1.0 sec 10.0 seconds. Confirm the selection by pressing the [P] butn. The display then switches back the menu level again. Activation / deactivation of the programming lock and completion of the standard parameterization, run: With the aid of the [ ] [ ] keys, you can choose between the deactivated key lock Uloc (works setting) and the activated key lock Loc. Make the selection with [P]. After this, the display confirms the settings with "- ---", and aumatically switches operating mode. If Loc was selected, the keyboard is locked. To get back in the menu level, you must press [P] for 3 seconds in operating mode. You must now enter the CODE (works setting 1 2 3 4) that appears using the [ ] [ ] keys plus [P] unlock the keyboard. FAIL appears if the input is wrong. 6

4. Setting up the device 4.3. Extended parameterization By pressing the [ ] & [ ] butns during standard parameterization for one second, the display switches the extended parameterization mode. Operation is the same as in standard parameterization. Menu level Parameterization level 4.3.1. MIN/MAX value inquiry - Assignment of key functions, Tast: Here, you can enter for the operating mode either a MIN/MAX value inquiry or a threshold value correction on the arrow keys. If the MIN/MAX memory is activated with EHER, the measured MIN/MAX values will be saved during operation and can be called up via the arrow keys [ ] [ ]. The values are lost if the device is restarted. If the threshold value correction LI.1 is selected, the limit values can be changed during operation without hindering the operating procedure. If No is parameterized, the arrow keys [ ] [ ] have no function in operating mode. 4.3.2. Flashing of display, FLAS: Here, flashing of the display can be added as an extra alarm function, either the first limit value (select: LI-1), the second limit value (select: LI-2) or both limit values (select: LI-12). With No (works setting), no flashing is assigned at all. 4.3.3. Limit values / Limits, LI-1: For both limit values, two different values can be parameterized. With this, the parameters for each limit value are called up one after the other. Hysteresis for limit values, HY-1: For all limit values, a hysteresis function exists that reacts according the settings (threshold exceedance / threshold undercut). 7

4. Setting up the device Menu level Parameterization level Function if display falls below / exceeds limit value, FU-1: The limit value undercut can be selected with Louu (LOW = lower limit value) and limit value exceedance can be selected with high (HIGH = upper limit value). If e.g. limit value 1 is on a switching threshold of 100 and occupied with function high, the alarm will be activated by reaching the threshold. If the limit value is allocated Low, an alarm will be activated by undercut of the threshold. Limit value /Limits, LI-2: For both limit values, two different values can be parameterized. With this, the parameters for each limit value are called up one after the other. Hysteresis for limit values, HY-2: For all limit values, a hysteresis function exists that reacts according the settings (threshold exceedance / threshold undercut). Function if display falls below / exceeds limit value, FU-2: To indicate if the value falls below the lower limit value, Louu can be selected (LOW = lower limit value) and if it goes above the upper limit value, high can be selected (HIGH = upper limit value). LOW corresponds the quiescent current principle and HIGH the operating current principle. Setting the code, CODE: With this setting, it is possible select an individual code (works setting 1 2 3 4) for locking the keyboard. To lock/release the key, proceed according menu item run. 8

4. Setting up the device Functional principle of the set points Limit value exceedance High By limit value exceedance the alarm S1-S2 is off below the threshold and on on reaching the threshold. Limit value undercut low By limit value undercut the alarm S1-S2 is on below the threshold and switched off on reaching the threshold. Alarms / optical setpoint display An activated set point can be optically indicated by flashing of the 7-segment display. Functional principle of the alarms Alarm Threshold Hysteresis Function Deactivated, display value Threshold/limit value for switch over Width of the window between the thresholds Limit value exceedance / limit value undercut 9

5. Facry settings 5. Facry settings 5.1. Default values Parameter Menu items or Default 5.2. Reset default values To return the unit a defined basic state, a reset can be carried out the default values. The following procedure should be used: Switch off the power supply Press butn [P] Switch on voltage supply and press [P]-butn until ---- is shown in the display. With reset, the default values of the program table are loaded and used for subsequent operation. This puts the unit back the state in which it was supplied. Caution! All application-related data are lost. 10

6. Technical data 6. Technical data Housing Dimensions 96x24 96x24x60 mm (BxHxT) 96x24x74 mm (BxHxT) including plug-in terminal Panel cut-out 96x24 Insulation thickness Fixing Material Sealing material Protection class Weight Connection Display Digit height Segment colour Display range Setpoints Overflow Underflow Display time 92.0 +0.8 x 22.2 +0.3 mm up 3 mm snap-in screw element PC Polycarbonate, black, UL94V-0 EPDM, 65 Shore, black standard IP65 (front), IP00 (back side) approx. 200 g plug-in terminal; wire cross section up 2.5 mm 2 14 mm red -1999 bis 9999 optical display flashing horizontal bars at the p horizontal bars at the botm 0.1 10.0 seconds Input Measuring range Measuring fault (at 1 sec measuring time) Digit Typ L (Fe-CuNi alter Typ) -200 900 C Typ J (Fe-CuNi) -210 1200 C Typ K (NiCr-NiAL) -270 1372 C Typ B (Pt30Rh-Pt6Rh) 80 1820 C Typ S (Pt10Rh-Pt) -50 1768 C Typ N (NiCrSi-NiSi) -270 1300 C Typ E (NiCr-CuNi) -270 1000 C Typ T (Cu-Cu-Ni) -270 400 C Typ R (Pt13Rh-Pt) -50 1768 C Characteristic line failure < K Reference junction Semiconducr sensor 11

6. Technical data Temperature drift Measuring time Measuring principle Resolution Power pack 100 ppm / K 0.1 10.0 seconds U/F-conversion 0.1 C or 0.1 F 230 VAC +/- 10 % max. 6 VA 24 VDC +/- 10 % max. 1 VA Memory Data life EEPROM 100 years Ambient conditions Working temperature Sring temperature Weathering resistance 0 60 C -20 80 C relative humidity 0-85% on years average without dew EMV EN 61326 CE-sign Conformity directive 2004/108/EG Safety standard According low voltage directive 2006/95/EG EN 61010; EN 60664-1 12

7. Safety advice 7. Safety advice Please read the following safety advice and the assembly chapter 1 before installation and keep it for future reference. Proper use The M1-device is designed for the evaluation and display of sensor signals. Danger! Careless use or improper operation can result in personal injury and/or damage the equipment. Control of the device The panel meters are checked before dispatch and sent out in perfect condition. Should there be any visible damage, we recommend close examination of the packaging. Please inform the supplier immediately of any damage. Installation The M1-device must be installed by a suitably qualified specialist (e.g. with a qualification in industrial electronics). Notes on installation There must be no magnetic or electric fields in the vicinity of the device, e.g. due transformers, mobile phones or electrostatic discharge. The fuse rating of the supply voltage should not exceed a value of 6A N.B. fuse. Do not install inductive consumers (relays, solenoid valves etc.) near the device and suppress any interference with the aid of RC spark extinguishing combinations or free-wheeling diodes. Keep input, output and supply lines separate from one another and do not lay them parallel with each other. Position go and return lines next one another. Where possible use twisted pair. So, you receive best measuring results. Screen off and twist sensor lines. Do not lay current-carrying lines in the vicinity. Connect the screening on one side on a suitable potential equaliser (normally signal ground). The device is not suitable for installation in areas where there is a risk of explosion. Any electrical connection deviating from the connection diagram can endanger human life and/or can destroy the equipment. The terminal area of the devices is part of the service. Here electrostatic discharge needs be avoided. Attention! High voltages can cause dangerous body currents. Galvanic insulated potentials within one complex need be placed on a appropriate point (normally earth or machines ground). So, a lower disturbance sensibility against impacted energy can be reached and dangerous potentials, that can occur on long lines or due faulty wiring, can be avoided. 13

8. Error elimination 8. Error elimination 1. 2. 3. 4. 5. 6. 7. Error description The unit permanently indicates overflow. The unit permanently shows underflow. The word "HELP " lights up in the 7-segment display. Program numbers for parameterising of the input are not accessible. "Err1" lights up in the 7-segment display The device does not react as expected. Temperature value is instable. Measures The input has a very high measurement, check the measuring circuit. The input is open The input has a very low measurement, check the measuring circuit. The input is open. The unit has found an error in the configuration memory. Perform a reset on the default values and re-configure the unit according your application. Programming lock is activated Enter correct code Please contact the manufacturer if errors of this kind occur. If you are not sure if the device has been parameterised before, then follow the steps as written in chapter 5.2. and set it back its delivery status. Check the possibility cancel the galvanic insulation and therewith divert failures, as described in chapter 2 Electric connection. First make sure that a possible metallic sensor body is separated from the sensor element. M1_3TGB.pdf 14 Stand: 28.10.2011