SMALL OIL SEALED PUMPS

Similar documents
THE ULTIMATE DRY CHOICE

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Agilent High Capacity RV Pumps & Roots Pumping Systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

MAXIMISE YOUR PRODUCTIVITY AND PERFORMANCE

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

ih Series Drypumps (505) idealvac.com idealvac.com

Varian, Inc. Vacuum Technologies Industry Leading Vacuum Performance High Capacity MS-Series Rotary Vane Pumps & RPS-Series Roots Pumping Systems

AGILENT ROUGH VACUUM PUMPS

Immersion Pumps HCT (High Chem) sealless

Gear Pump Units For single-line centralized lubrication systems

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Okta 1000, Roots pump without motor

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

EXPlora. Introduction

New SV series / Holger Falk / Distributor meeting Page 2

Circuit-Breakers for Motor Protection Series 8523/8

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Immersion Pumps HCT (High Chem) sealless EN

Series description: Wilo-Drain VC

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Electromagnetic Block Valves Direct Acting

Screw pump Series ALLFUEL AFT

Series 8800 Radial Tip Fans Design 8812

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

2.9 Sigma/ 2 Plunger Metering Pumps

Gear Pump Units. For single-line lubrication systems

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

Pendant Light Fitting IEC Series 6470/2

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

Dry Compressing Vacuum Pumps

P Output Ratings. Dimensions and Weights. Prime Rating

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

Series 7600 Centrifugal Airfoil Fan

P Output Ratings. Dimensions and Weights. Prime Rating

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

Product Data Sheet 4656 EZ

P1350P1/P1500E1 50Hz

Model KBF 115 Constant climate chambers with large temperature / humidity range

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Dry Com. Dry Compressing Vacuum Pumps

Fluid Cooling P-BAR b Industrial BOL Series

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

Trends and Challenges of HV Cable Systems

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

AC diagonal module Ø 200 mm

Axial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management

Twin City Fan & Blower

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Model KBF 1020 Constant climate chambers with large temperature / humidity range

ULTRALOW TEMPERATURE FREEZERS -86 C

Product catalogue 2010

CITOCUT Plasma inverter cutting range

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

IONIVAC Transmitter ITR 90

Parts List _2.1. Flygt /.190

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Magnetic Stirrers Magnetic Stirr

Part-Turn Electric Multi-Turn Electric

Revision 1.0 Parts List Minor

8 Installation Equipment

Product Data Sheet 4656 ZW

GS-HYDRO END FORMING MACHINES

PROPORTIONAL VALVES Sentronic plus

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Transcription:

SMALL OIL SEALED PUMPS PERFORMANCE YOU CAN RELY ON EM0.7 and.5 Oil Sealed Rotary Vane Pumps 8 RV Oil Sealed Rotary Vane Pumps 86 RV ATEX Oil Sealed Rotary Vane Pumps 94 EM8 and 8 Oil Sealed Rotary Vane Pumps 97 EM8 and EM8 Atex Oil Sealed Rotary Vane Pumps Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 8.

EM0.7 AND.5 OIL SEALED ROTARY VANE PUMPS PERFORMANCE YOU CAN RELY ON EM0.7 and EM.5 two stage oil sealed rotary vane pumps are renowned for achieving high ultimate vacuum and rapid pumping speeds, with quiet operation and compact size. Providing long term reliability, these pumps have become the industry standard in range of scientific and laboratory applications, and the ideal partner for your tubomolecular pump. The drive is provided through and Oldham coupling by a single phase motor. The motor is totally enclosed and cooled by the motor cooling fan which directs the air along the motor fins. A thermal overload device is fitted to the motor which switches off the pump if the motor gets too hot, this will automatically reset when the motor cools down and restarts the pump. Features and Benefits Pumping speeds of either 0.7 to.5 m h. Industry proven long term reliable performance. Free standing, compact design providing flexibility of use. Alternate side inlet connection port so that overall installation height can be reduced to minimum when required. Low noise, with the EM0.7 at just 4 db(a). Low energy consumption, with the EM0.7 at 0.09 kw. O ring sealed sight glass allows visual inspection of oil level and condition. Gas ballast valve for large water vapour handling capacity. Simple installation and operation with no customer wiring. Forced air cooling ensures low pump surface temperature. Internal ATEX classification of Ex II G c IIB T4. Approved EN6, CSA. and UL6. Applications Analytical instruments. Leak detectors, helium. Research and development. Backing turbomolecular pumps. Laboratory bench top vacuum. Pump Range EM -- EM0.7 -- EM.5 8. Small Oil Sealed Pumps

Performance Curves EM0.7 Rotary vane pump EM0.7 EM0.7 Performance Curve 0 50 Hz 0.9 m h / 0.5 ft min 60 Hz. m h / 0.6 ft min Speed (m h - ) - 50 Hz 0.75 m h / 0.4 ft min - 60 Hz 0.95 m h / 0.5 ft min - - - - 0 50Hz (mbar) - 0 4 (Pa) 0 EM0.7 00 0 V, ph, 50/60 Hz, IEC 600 connectors A7499 EM0.7 0 0 V, ph, 50/60 Hz, IEC 600 connectors A7490 Each EM0.7 pump is supplied with litre of Ultragrade 5 oil, O ring and centering ring, two Allen keys and spare seals for oil drain and filter plugs. - (ft min ) - - - - - - 0 60Hz (Torr) EM.5 Rotary vane pump EM.5 EM.5 Performance Curve 50 Hz.8 m h / ft min 60 Hz. m h /. ft min Speed 50 Hz.6 m h / 0.8 ft min 60 Hz.0 m h /. ft min (m h - ) 0-50Hz - - - - 0 (mbar) 0-4 5 (Pa) EM.5 00 0 V, ph, 50/60 Hz, IEC 600 connectors A799 EM.5 0 0 V, ph, 50/60 Hz, IEC 600 connectors A790 0 EM.5 interstage 00 0 V, ph, 50/60 Hz, IEC 600 connectors EM.5 interstage 0 0 V, ph, 50/60 Hz, IEC 600 connectors A7499 A7490 (ft min - ) - - 60Hz - - - 0 (Torr) Each EM.5 pump is supplied with litre of Ultragrade 5 oil, O ring and centering ring, two Allen keys and spare seals for oil drain and filter plugs. Without Gas Ballast With Gas Ballast Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 8.

Dimensions EM0.7/.5. dimensions 55 (6.) 4 (5.59) 6.5 (8.9) 66.5 (6.55) 55 (6.) (.7) 85 (.4) 75 (.95) (4.).5 (0.45) 40 (5.5) 5 (4.9) 9 (0.75) 8 (0.70) 4 (5.7) 46.5 (.8) 54 (.) 5 (0.98) 0 (.8) 0-40 V motor Handle can be removed Alternative inlet position Technical Data Units EM0.7 EM.5 (swept volume) 50 Hz m h /ft min 0.9/0.5.8/ 60 Hz m h /ft min./0.6./. Speed (Pneurop 660) 50 Hz m h /ft min 0.75/0.4.6 / 0.8 60 Hz m h /ft min 0.95/0.5.0/. Ultimate vacuum (total pressure) without gas ballast mbar/torr.0 x /. x x /. x with full gas ballast mbar/torr.0 x /.5 x.5 x /.9 x Inlet connection NW flange Outlet connection Nozzle mm external Ø removable from ⅜" BSP tapped hole Maximum permitted pressure at outlet 0.5 bar gauge/7 psig Maximum inlet pressure for water vapour mbar/torr 5/ Maximum water vapour pumping rate gh 8 6 Motor power kw 0.09 0.6 Nominal rotational speed 50/60 Hz rpm 400/700 800/400 Power connector IEC EN600 C Operating temperature range C -40 Weight, without oil kg/lbs / Noise db(a) 4 @ 50 Hz 54 @ 50 Hz Noise with acoustic enclosure db(a) EM0.7 6 db(a) @ 50 Hz EM.5 47 db(a) @ 50 Hz Oil capacity maximum litre 0.8 Oil capacity minimum litre 0. Recommended oil (supplied) Ultragrade 5 84. Small Oil Sealed Pumps

Service, Spares and Accessories Model EMF mist filter A460000 Ultragrade 5 oil litre H605 Ultragrade 5 oil 4 litre H60 m electrical supply cable for ph pumps, UK, three pin plug A50505000 m electrical supply cable for ph pumps, North European plug A50506000 m electrical supply cable for ph pumps, North America/Japan plug A50507000 m electrical supply cable for ph pumps, no plug A50508000 Spares Kit C&O EM0.7//.5 A7 Spares Kit Blade EM0.7/.5 A7 NW Centring Nitrile S/S Pk C596 NW O Ring Viton Pk 5 H040 NW x ⅜'' BSP adapter A5908064 Service Edwards products, spares and accessories are available from Edwards companies in Belgium, Brazil, China, France, Germany, Israel, Italy, Japan, Korea, Singapore, United Kingdom, U.S.A. and a worldwide network of distributors. The majority of these centres employ Service Engineers who have undergone comprehensive Edwards training courses. Order spare parts and accessories from your nearest Edwards company or distributor. When you order, please state for each part required: Model and item number of your equipment. Serial number (if any). Item number and description of the part. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 85.

RV OIL SEALED ROTARY VANE PUMPS PERFORMANCE YOU CAN RELY ON The RV series of small oil sealed rotary vane pumps deliver excellent ultimate vacuum pressure, high pumping speeds and superior vapour handling capabilities with quiet operation. With over 00,000 units produced, these pumps offer proven performance that sets the industry standard for R&D and scientific pumping applications. All RV pumps are approved to UL and CSA standards by an external test house and feature our unique mode selector switch, meaning one model is suitable for both high vacuum or high throughput applications. In summary, you can rest assured that when you choose an Edwards RV oil sealed rotary vane pump you are choosing a product you can rely on from a company you can trust. Features and Benefits High reliability generous lubrication of moving parts. Safe process and systems fast acting inlet valve for best in class anti suck back protection. Configured to meet your vacuum needs mode selector and two position gas ballast. No unplanned downtime designed for easy maintenance. Better work environment quiet running and intrusive frequencies minimised. Two position gas ballast allows either 60 g/hr or a class leading 0 g/hr (90 g/hr on RV) of water vapour to be handled. Universal motor to cover the widest possible voltage and frequency range from a single variant. Smooth controlled inlet valve opening by oil pressure to eliminate pressure surges. Rapid closing inlet valve within 0.4 seconds of pump stopping. Applications Analytical instruments. Laboratory bench top vacuum. Backing turbomolecular pumps. Freeze drying. Research and development. Pump Range RV -- RV -- PFPE RV RV5 -- RV5 -- PFPE RV5 RV8 -- RV8 -- PFPE RV8 RV -- RV -- PFPE RV 86. Small Oil Sealed Pumps

Performance Curves RV Oil Sealed Rotary Pump RV RV Performance Curve Ordering information 50 Hz.7 m h. ft min 60 Hz 4.5 m h.6 ft min Speed (Pneurop 660) 50 Hz. m h.0 ft min 60 Hz.9 m h. ft min (m h - ) 0 - RV, 50Hz - - - 0-0 4 5 (mbar) (Pa) RV 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe A65090 (ft min - ) 0 RV 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan RV 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz factory set to 80/460 V A650904 A650905 - RV, 60Hz - - - 0 (Torr) RV 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA A650906 PFPE RV 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe PFPE RV 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan PFPE RV 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V A650990 A6509904 A6509905 High vacuum mode, gas ballast = 0 High throughput mode, gas ballast mode = 0 and High vacuum mode, gas ballast = I High vacuum and throughput mode, gas ballast = II PFPE RV 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA A6509906 Each RV pump is supplied with litre of Ultragrade 9 oil, inlet filter and O ring. For PFPE prepared pumps Fomblin oil to be ordered separately. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 87.

RV5 Oil Sealed Rotary Pump RV5 Performance Curve RV5 (m h - ) (ft min - ) 0 - - 0 - - - 0 - RV5, 50Hz 0 4 5 (mbar) RV5, 60Hz - - - 0 (Torr) High vacuum mode, gas ballast = 0 High throughput mode, gas ballast mode = 0 and High vacuum mode, gas ballast = I High vacuum and throughput mode, gas ballast = II (Pa) 50 Hz 5.8 m h.4 ft min 60 Hz 7.0 m h 4. ft min Speed (Pneurop 660) 50 Hz 5. m h.0 ft min 60 Hz 6. m h.7 ft min Ordering information RV5 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe RV5 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan RV5 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V RV5 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA PFPE RV5 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe PFPE RV5 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan PFPE RV5 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V PFPE RV5 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA A65090 A650904 A650905 A650906 A650990 A6509904 A6509905 A6509906 Each RV pump is supplied with litre of Ultragrade 9 oil, inlet filter and O ring. For PFPE prepared pumps Fomblin oil to be ordered separately. 88. Small Oil Sealed Pumps

Performance Curves RV8 Oil Sealed Rotary Pump RV8 RV8 Performance Curve 50 Hz 9.7 m h 5.7 ft min 0 60 Hz.7 m h 6.9 ft min (m h - ) - Speed (Pneurop 660) 50 Hz 8.5 m h 5.0 ft min 60 Hz m h RV8, 50Hz - - - 0 (mbar) - - 0 4 5 (Pa) Ordering information 5.9 ft min RV8 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe RV8 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan RV8 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V RV8 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA PFPE RV8 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe PFPE RV8 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan PFPE RV8 00 0/80 45 V, ph, 50 Hz, and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V PFPE RV8 5/0 V, ph, 50/60 Hz, factory set to 5 V for Europe A654090 A6540904 A6540905 A6540906 A6540990 A65409904 A65409905 A65409906 (ft min - ) 0 - RV8, 60Hz - - - 0 - (Torr) High vacuum mode, gas ballast = 0 High throughput mode, gas ballast mode = 0 and High vacuum mode, gas ballast = I High vacuum and throughput mode, gas ballast = II Each RV pump is supplied with litre of Ultragrade 9 oil, inlet filter and O ring. For PFPE prepared pumps Fomblin oil to be ordered separately. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 89.

RV Oil Sealed Rotary Pump RV Performance Curve RV (m h - ) 0 - RV, 50Hz - - - 0 (mbar) - - 0 4 5 (Pa) 50 Hz 4. m h 8.4 ft min 60 Hz 7 m h ft min Speed (Pneurop 660) 50 Hz m h 7. ft min 60 Hz 4. m h 8.4 ft min Ordering information (ft min - ) 0 RV, 60Hz - - - 0 - High vacuum mode, gas ballast = 0 High throughput mode, gas ballast mode = 0 and High vacuum mode, gas ballast = I High vacuum and throughput mode, gas ballast = II (Torr) RV 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe RV 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan RV 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V RV 5/0 V, ph, 50/60 Hz, factory set to 5 V for USA PFPE RV 5/0 V, ph, 50/60 Hz, factory set to 0 V for Europe PFPE RV 0/00 V, ph, 50/60 Hz, factory set to 00 V for Japan PFPE RV 00 0/80 45 V, ph, 50 Hz and 00 0/460 V, ph, 60 Hz, factory set to 80/460 V PFPE RV two stage Rotary vane pump 5/0 V ph 50/60 Hz, factory set to 5 V for USA A655090 A6550904 A6550905 A6550906 A6550990 A65509904 A65509905 A65509906 Each RV pump is supplied with litre of Ultragrade 9 oil, inlet filter and O ring. For PFPE prepared pumps Fomblin oil to be ordered separately. 90. Small Oil Sealed Pumps

Dimensions RV Dimensions 7 (.46) (.6) A B C F NW5 NW5 (8.70) E D 0 (4.7) 4 x Ø9 (0.5) 78 (.07) 58 (6.) 0 (9.06) (0.9) RV/5 RV8 RV A 40 (6.9) 470 (8.50) 490 (9.9) B 7 (5) 6 (6.4) 8 (7.) C 9 (.4) 5 (.8) 5 (.8) D 4 (0.6) 4 (0.6) 4 (0.6) E 67 (.5) 6 (.8) 6 (0.8) F 49 (6.89) 469 (8.46) 489 (9.5) Dimensions in mm (inch). Phase motor Phase motor Retractable handle RV and 5 only. RV8 and have lifting eye Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 9.

Technical Data Units RV RV5 RV8 RV 50 Hz m h /ft min.7/. 5.8/.4 9.7/5.7 4./8.4 60 Hz m h /ft min 4.5/.6 7.0/4..7/6.9 7/ Speed (Pneurop 660) 50 Hz m h /ft min./ 5./.0 8.5/5 /7. 60 Hz m h /ft min.9/. 6./.7 /5.9 4./8.4 Ultimate pressure mbar/torr.0 x /.5 x Ultimate pressure GB I mbar/torr.0 x /. x Ultimate pressure GB II mbar/torr. x / 9. x.0 x / 7.5 x Ultimate Pressure with Fomblin mbar/torr x /.5 x 6 x /4.6 x Max inlet pressure for water vapour mbar/torr 80/60 50/8 8/8.5 /4 Max water vapour pumping rate GB I gh 60 Max water vapour pumping rate GB II gh 0 Max allowed outlet pressure bar gauge/psig 0./.8 Max allowed inlet and gas ballast pressure bar gauge/psig 0.5/7 Motor power 50/60 Hz W 450/550 Power connector ph IEC EN600 C Nominal rotation speed 50/60 Hz rpm 500/800 Weight (without oil) kg/lb 5/55 8/6.6 9/6.8 Oil capacity min/max litres 0.4/0.7 0.4/0.75 0.65/ Recommended oil Ultragrade 9 Inlet flange Exhaust flange NW5 NW5 Noise level db(a) 48 @ 50 Hz Operating temperature range C 40 Service Edwards products, spares and accessories are available from Edwards companies in Belgium, Brazil, China, France, Germany, Israel, Italy, Japan, Korea, Singapore, United Kingdom, U.S.A. and a worldwide network of distributors. The majority of these centres employ Service Engineers who have undergone comprehensive Edwards training courses. Order spare parts and accessories from your nearest Edwards company or distributor. When you order, please state for each part required: Model and item number of your equipment. Serial number (if any). Item number and description of the part. 9. Small Oil Sealed Pumps

Service, Spares and Accessories Also see p60. RV Accessories m electrical supply cable for ph pumps, UK, three pin plug A50505000 m electrical supply cable for ph pumps, North European plug A50506000 m electrical supply cable for ph pumps, North America/Japan plug A50507000 m electrical supply cable for ph pumps, no plug A50508000 Ultragrade 9 oil litre H505 Ultragrade 9 oil 4 litre H50 Model EMF mist filter A466000 Gas Ballast adaptor A5050000 Clean application oil return kit A5049000 Adjustable gas ballast oil return kit A505000 RV easy oil box drain kit A5050000 Exhaust nozzle kit ¾ to 5 mm A50509000 Acoustic Enclosure RV acoustic enclosure 0 V RV acoustic enclosure 00 40 V NRD7000 NRD8000 Vibration Isolator RV Vibration isolator (0.45 kg) A480404 Spares Kits Spares Kit Cartridge RV A650 Spares Kit Cartridge RV5 A650 Spares Kit Cartridge RV8 A6540 Spares Kit Cartridge RV A6550 Spares Kit Blade RV A6500 Spares Kit Blade RV5 A6500 Spares Kit Blade RV8 A65400 Spares Kit Blade RV A65500 Spares Kit Inlet valve RV/5/8/ A6506 Spares Kit clean and overhaul kit A650 Spares Kit clean and overhaul kit (Nitrile) A6507 Spares Kit outer shaft seal kit RV A6504 Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 9.

RV ATEX OIL SEALED ROTARY VANE PUMPS PERFORMANCE YOU CAN RELY ON ATEX RV pumps have an external ATEX classification of Ex II G IIC T4 and are suitable for use in potentially explosive atmospheres. They share the same internal ATEX classification as our standard RV pumps, namely Ex II G c IIB T4. ATEX pumps with flameproof motors require the user to provide off hazardous area cable glands and cables. In addition, connection of the thermistors to an appropriate safety circuit must be made to switch off the pump if overheating occurs. The pumps are supplied with the Gas Ballast port plugged. When pumping flammable gasses or vapours you must fit an inert gas purge to this port to dilute such gases or vapours below the lower explosive limit. Features and Benefits ATEX rated spot voltage motor. Dual mode. Suitable for high throughput and high vacuum applications. Fast acting inlet valve for system protection. Efficient high pressure lubrication. Oil tight with printed gaskets, effective shaft seals. Clamped in sight glass. Oil box well contains filling spills. Hi tech polymer blades, large diameter, easy clean oil passages. Consistent, built in quality, cast bar construction. -- 94. Small Oil Sealed Pumps

Performance Curves RV ATEX Oil sealed rotary pump RV ATEX RV ATEX Performance Curve (m h - ) 0 - RV RV5 RV8 RV - - - 0 - (mbar) - 0 4 5 (Pa) RV RV5 RV8 RV 50 Hz.7 m h 5.8 m h 9.7 m h 4. m h. ft min.4 ft min 5.7 ft min 8.4 ft min 60 Hz 4.5 m h 7.0 m h.7 m h 7 m h.6 ft min 4. ft min 6.9 ft min ft min Speed (Pneurop 660) 50 Hz. m h 5. m h 8.5 m h m h.0 ft min.0 ft min 5.0 ft min 7. ft min 60 Hz.9 m h 6. m h m h 4. m h. ft min.7 ft min 5.9 ft min 8.4 ft min (ft min - ) 0 - - - 0 (Torr) - Blue Red No gas purge With inert gas purge RV RV5 RV8 RV Ordering information ATEX RV 5V, -ph, 60 Hz ExII G IIC T4 * ATEX RV 0 V, ph, 50 Hz Ex II G IIC T4 ATEX RV 400 V, ph, 50 Hz Ex II G IIC T4 ATEX RV5 5V, -ph, 60 Hz ExII G IIC T4 * ATEX RV5 0 V, ph, 50 Hz Ex II G IIC T4 ATEX RV5 400 V, ph, 50 Hz Ex II G IIC T4 ATEX RV8 5V, -ph, 60 Hz ExII G IIC T4 * ATEX RV8 0 V, ph, 50 Hz Ex II G IIC T4 ATEX RV8 400 V, ph, 50 Hz Ex II G IIC T4 ATEX RV 5V, -ph, 60 Hz ExII G IIC T4 * ATEX RV 0 V, ph, 50 Hz Ex II G IIC T4 ATEX RV 400 V, ph, 50 Hz Ex II G IIC T4 A659986 A658989 A65899 A659986 A658989 A65899 A6549986 A6548989 A654899 A6559986 A6558989 A655899 * 750W motor Each ATEX RV pump is supplied with litre of Ultragrade 9 oil, inlet filter and O ring. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 95.

Dimensions RV ATEX Dimensions Pump A B C RV 50 mm (0.47 ) 7 mm (5 ) 9 mm (.06 ) RV5 50 mm (0.47 ) 7 mm (5 ) 9 mm (.06 ) RV8 560 mm (.05 ) 6 mm (6.4 ) 5 mm (.8 ) RV 580 mm (.8 ) 8 mm (7. ) 5 mm (.8 ) Dimensions in mm (inch). Technical Data Units RV ATEX RV5 ATEX RV8 ATEX RV ATEX 50 Hz m h /ft min.7/. 5.8/.4 9.7/5.7 4./8.4 60 Hz m h /ft min 4.5/.6 7/4..7/6.9 7/ Speed (Pneurop 660) 50 Hz m h /ft min./ 5./ 8.5/5 /7. 60 Hz m h /ft min.9/. 6./.6 /5.9 4./8.4 Max allowed outlet pressure bar gauge/psig 0./.8 Max allowed inlet and gas purge pressure bar gauge/psig 0.5/7 Nominal rotation speed 50/60 Hz rpm 40/7 Motor power 50/60 Hz W 550 (750 for 5V ph 60Hz) Weight (without oil) kg/lb 8/6.6 /68. Inlet flange NW5 Exhaust flange NW5 Operating temperature range C 40 96. Small Oil Sealed Pumps

EM8 AND 8 OIL SEALED ROTARY VANE PUMPS PERFORMANCE YOU CAN RELY ON The EM range of oil sealed rotary pumps renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and ability to handle vapour have become the industry standard for laboratory and light industrial applications. The pump is a freestanding unit with the drive provided through a flexible coupling by either a single phase or three phase (four pole) motor. Features and Benefits The pump is designed for reliable, long term operation. Thermal overload device prevents overheating (single phase only). The drive is provided through a flexible coupling by a single phase or three phase (four pole) motor. The motors are totally enclosed and are cooled by the motor cooling fan. Full height O ring sealed oil sight glass for easy checking of oil level and condition. Large sight glass and operating oil range. IE energy efficient phase motor used with EM8. Applications Analytical instruments. Leak detectors, helium. Research and development. Backing turbomolecular pumps. Automotive. Beam lines and high energy physics. Centrifuges, ultra high speed. Coating. Pump Range EM EM8 single stage. EM8 FX single stage. EM8 two stage. EM8 FX two stage. EM8 two stage. EM8 FX two stage. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 97.

Performance Curves EM8 One stage, EM8 two stage rotary vane pumps E/EM8 E/EM8 Performance Curve 50 Hz 0.5 m h (. ft min ) 60 Hz 5 m h (4.7 ft min ) Speed (Pneurop 660) 50 Hz 7 m h ( ft min ) 60 Hz 0.4 m h (. ft min ) (m h - ) 0 50Hz EM8 EM8 - - - - 0 (mbar) Ordering information EM8 00 0/80 45 V, ph, 50 Hz or 00 0/460 V, ph, 60 Hz EM8 0/00 V, ph, 50 Hz or 0 5/00 V, ph, 60 Hz EM8 5/00 0 V, ph, 50/60 Hz with IEC600 connector, factory set to 0V EM8 FX 5/00 0 V, ph, 50/60 Hz with IEC600 connector EM8 00 0/80 45 V, ph, 50 Hz or 00 0/460 V, ph, 60 Hz EM8 0/00 V, ph, 50 Hz or 0 5/00 V, ph, 60 Hz EM8 5/00 0 V, ph, 50/60 Hz with IEC600 connector EM8 FX 00 0/80 45 V, ph, 50 Hz or 00 0/460 V, ph, 60 Hz EM8 FX 0/00 V, ph, 50 Hz or 0 5/00 V, ph, 60 Hz EM8 FX 5/00 0 V, ph, 50/60 Hz with IEC600 connector fitted A4940 A45904 A47984 A45984 A6940 A65904 A67984 A6940 A65904 A65984 (ft min - ) 0-0 4 60Hz EM8 EM8 - -4 - - - 0 Without gas ballast With gas ballast (Pa) (Torr) Each EM pump is supplied with litre of Ultragrade 9 oil, O ring and centering ring, two Allen keys and spares seal for oil drain and filter plugs. For PFPE prepared FX pumps Fomblin to be ordered separately. 98. Small Oil Sealed Pumps

EM8 two stage Rotary vane pump EM8 Performance Curve EM8 (m h - ) 0 - -4 - - 0-50 Hz (mbar) 50 Hz. m h (9 ft min ) 60 Hz 8.9 m h (. ft min ) Speed (Pne urop 660) 50 Hz 7.5 m h (6. ft min ) 60 Hz m h (9.5 ft min ) - 0-4 5 (Pa) Ordering information (ft min - ) 0 - -4 - - 0-60 Hz (Torr) EM8 5/00-0V, ph, 50/60 Hz with IEC600 connector fitted EM8 0/00V, ph, 50 Hz or 0-5/00-V, ph 60Hz EM8 HC PH IE ASIA 50/60HZ 00V 50/60HZ, 80V 60HZ EM8 HC PH IE EU/US 50/60HZ 80-400V 50HZ, 0 / 460V 60HZ A77984 A75904 A794 A7940 EM8 FX 5/00-0V, ph, 50/60 Hz with IEC600 connector fitted A75984 Without gas ballast With gas ballast EM8 FX PH IE ASIA 50/60HZ 00V 50/60HZ, 80V 60HZ EM8 FX PH IE EU/US 50/60HZ 80-400V 50HZ, 0 / 460V 60HZ A7494 A74940 Each EM pump is supplied with litre of Ultragrade 9 oil, O ring and centering ring, two Allen keys and spares seal for oil drain and filter plugs. For PFPE prepared FX pumps Fomblin to be ordered separately. Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps 99.

Dimensions EM8 and EM8 dimensions 70 (6.69) 6.5 (0.65) 6.5 (8.9) 4.5 (9.55) G A B C Ø5 (0.59) E 7.4 (.08) 9 (.5) 4 (.69) 75 (0.9) (.95) 50 (5.9) F 0 (0.79) 80 (.0) 60 (.4) (0.9) D 4 x Ø9 (0.5) 9 (.5) A B C D E F G A4940 474 47 8 59 7.4 7 A45904 58 474 47 8 59 7.4 4 A47984 504 47 8 59 7.4 5 A6940 50 95 07 7.4 7 A65904 564 50 95 07 7.4 4 A67984 550 95 07 7.4 5 EM8 Dimensions 80 (7.09) 70 (6.69) 6.5 (0.65) 6.5 (8.9) 4 (9.49) C A B (.0) Ø5 (0.59) NW5 55 (6.) 40.5 (9.47) (4.7) 5.5 (.00) 9. (.55) 4 (.69) 0 60 (0.79) (.6) 0 (4.7) 60 (6.9) 0 (0.79) (0.5) 47 (.66) 7 (4.68) 4 x Ø9 (0.5) 8.7 (.5) A B C A7940 65 9 A75904 598 584 5 A77984 584 5 0.Small Oil Sealed Pumps

Technical Data Units EM8 EM8 EM8 50 Hz m h /ft min 0.5/../9 60 Hz m h /ft min 5.0/4.7 8.9/. Speed (Pneurop 660) 50 Hz m h /ft min 7.0/ 7.5/6. 60 Hz m h /ft min 0.4/..0/9.5 Ultimate vacuum (total pressure) without gas ballast mbar/torr x /. x x / 7.4 x 4 x / 7.5 x 4 with gas ballast mbar/torr 6.5 x /4.8 x.5 x /. x.5 x /. x with Fomblin mbar/torr x /.56 x x / 7.5 x x /7.5 x Inlet connection Outlet connection* NW5 Nozzle 5 mm external Ø removable from /4 in BSP tapped hole Max permitted pressure at outlet bar gauge/psig 0.5/7 Max inlet pressure for water vapour mbar/torr 50/8 0/5 0/ Max water vapour pumping rate kg h 0.65 0. 0.7 Operating temp range 40 C Nominal Rotation speed 50/60 Hz rpm 440/70 rpm Power connector ph** IEC EN600 C9 Motor power 50 Hz kw 0.55 kw 0.75 kw Motor power 60 Hz kw 0.75 kw 0.90 kw Weight kg/lbs 7/8 9/86 44/97 Noise @ 50 Hz db(a) 57 Oil capacity max litre.4.05.5 Oil capacity min litre 0.9 0.75. Recommended oil (supplied) Ultragrade 9 * The FX are supplied with NW5 outlet connection ** pumps listed with IEC connector only Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps.

Service, Spares and Accessories EM Accessories m electrical supply cable, UK, three pin plug A5050500 m electrical supply cable, North European plug A5050600 m electrical supply cable, North America/Japan plug A5050700 m electrical supply cable, no plug A5050800 EMF0 mist filter (suitable for EM8 on low throughput applications) A469000 Ultragrade 9 oil litre H505 Ultragrade 9 oil 4 litre H50 Model MF0 mist filter A46000 NW5 to 8mm bore tube adaptor C500 ¾" BSP to NW5 outlet adaptor C5044 Spares Kits Spares kit C&O EM8/EM8 Spares kit Blade EM8 Spares kit Blade EM8 Spares kit Blade EM8/0 Spares kit clean and overhaul kit EM8 A60 A404 A600 A705 A70 Service Edwards products, spares and accessories are available from Edwards companies in Belgium, Brazil, China, France, Germany, Israel, Italy, Japan, Korea, Singapore, United Kingdom, U.S.A. and a worldwide network of distributors. The majority of these centres employ Service Engineers who have undergone comprehensive Edwards training courses. Order spare parts and accessories from your nearest Edwards company or distributor. When you order, please state for each part required: Model and item number of your equipment. Serial number (if any). Item number and description of the part..small Oil Sealed Pumps

EM8 AND EM8 ATEX OIL SEALED ROTARY VANE PUMPS PERFORMANCE YOU CAN RELY ON ATEX EM8 pumps have an external ATEX classification of Ex II G IIC T4 and are suitable for use in potentially explosive atmospheres. They share the same internal ATEX classification as our standard EM8 pumps, namely Ex II G c IIB T4. ATEX pumps with flameproof motors require the user to provide off hazardous area cable glands and cables. In addition, connection of the thermistors to an appropriate safety circuit must be made to switch off the pump if overheating occurs. The Pumps are supplied with the gas ballast port plugged. When pumping flammable gasses or vapours you must fit and inert gas purge to this port to dilute such gasses or vapours below the lower explosive limit. Supplied with ultragrade 9 oil, NW5 O ring and centering ring. Performance Curves EM8 One Stage, EM8 two stage Rotary vane ATEX pumps E/EM8 ATEX E/EM8 ATEX Performance Curve 50 Hz 0.5 m h (. ft min ) 60 Hz 5 m h (4.7 ft min ) Speed (Pneurop 660) 50 Hz 7 m h ( ft min ) 60 Hz 0.4 m h (. ft min ) (m h - ) 0 50Hz EM8 EM8 - - - - 0 (mbar) Ordering information EM8 ATEX 5 V, ph, 60 Hz Ex II G IIC T4 EM8 ATEX 0 V, ph, 50 Hz Ex II G IIC T4 EM8 ATEX 400 V, ph, 50 Hz Ex II G IIC T4 EM8 ATEX 5 V, ph, 60 Hz Ex II G IIC T4 EM8 ATEX 0 V, ph, 50 Hz Ex II G IIC T4 EM8 ATEX 400 V, ph, 50 Hz Ex II G IIC T4 A48986 A48989 A4899 A68986 A68989 A6899-0 4 Without gas ballast With gas ballast (Pa) (ft min - ) 0 60Hz EM8 EM8 - -4 - - - 0 (Torr) Without gas ballast With gas ballast Shop online at shop.edwardsvacuum.com Contact our customer service team Small Oil Sealed Pumps.

Dimensions EM8 and EM8 ATEX dimensions 70 (6.69) A B Ø5 (0.59) D 7.4 (.08) 6.5 (0.65) 6.5 (8.9) 80 (.0) 9 (.5) 4 (.69) 9 (.5) 75 (0.9) (.95) 50 (5.9) E 0 (0.79) 80 (.0) (0.9) 60 (.4) C 4 x Ø9 (0.5) A B C D E EM8 56 47 8 59 7.4 EM8 576 95 07 7.4 Technical Data Units EM8 ATEX EM8 ATEX 50 Hz m h /ft min 0.5/. 0.5/. 60 Hz m h /ft min 5.0/4.7 5.0/4.7 Speed (Pneurop 660) 50 Hz m h /ft min 7.0/ 7.0/ 60 Hz m h /ft min 0.4/. 0.4/. Ultimate vacuum (total pressure) without gas purge mbar/torr x /. x x / 7.4 x 4 with gas purge mbar/torr 6.5 x /4.8 x.5 x /. x with Fomblin mbar/torr Inlet connection NW5 Outlet connection Nozzle 5 mm external Ø removable from / 4 in BSP tapped hole Max permitted pressure at outlet bar gauge/psig 0.5/7 Max inlet pressure for water vapour mbar/torr 50/8 0/5 Max water vapour pumping rate kg h 0.65 0. Operating temp range C 40 Nominal rotation speed 50/60 Hz rpm 440/70 Motor power 50 Hz 0.55 kw 0.55 Motor power 60 Hz 0.75 kw 0.75 Weight kg/lbs 7/8 9/86 Noise @ 50 Hz db(a) 57 Oil capacity max litre.4.05 Oil capacity min litre 0.9 0.75 Recommended oil (supplied) Ultragrade 9 4.Small Oil Sealed Pumps