RCIT Cable Certification Testing Revised 10/2017

Similar documents
Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Datasheet: CertiFiber Pro Optical Loss Test Set

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

DESIGN!!GUIDELINES!!!!!

Versiv makes you money every time you use it.

Datasheet: CertiFiber Pro Optical Loss Test Set

The University of Texas at Austin September 30, 2011

Datasheet: CertiFiber Pro Optical Loss Test Set

The need for Encircled Flux, real or imaginary?

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

Datasheet: MultiFiber Pro

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Connectix Cabling Systems

SECTION COMMUNICATIONS HORIZONTAL CABLING

Datasheet: MultiFiber Pro Update

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Advanced Test Equipment Rentals ATEC (2832)

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

Copper Cabling Troubleshooting Handbook

SECTION TESTING OF COPPER CABLES

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Telecommunication Infrastructure Project September 20, 2002

Datasheet: SimpliFiber Pro

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Follow The Leader In Shielded Technology

Mar11 Rev E

جامعة مؤتة العطاءات املركزية توريد وتركيب وتشغيل أجهزة شبكات/كلية الزراعة. Central Tenders Mu tah University

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Datasheet: SimpliFiber Pro

Special Specification 6242 Special Fiber Optic Cable

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

SECTION FIBER OPTIC STATION CABLES

40G SWDM4 MSA Technical Specifications Optical Specifications

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

A guide to Woolworths Limited additional requirements. for the testing of twisted pair and fibre installation.

OPERATIONS GUIDE OWL

Cable Installation Tips

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Cable Installation Tips

Preferred ordering guide for NETCONNECT

Project No. # Page 1

40G SWDM4 MSA Technical Specifications Optical Specifications

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

DTX. Users Manual. Fiber Test Kit

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

Premise Installation Guide

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

Connected Solutions. April $ Post, 19 Rack ELERK1FR BK

Challenges for testing 10GBASE-T

HYPERLINE UTP/STP Cable Strippers and Cutters

PREMIUM 5e F/UTP PRODUCTS

MPO Technology Connectivity & Application

DSP-4000 Series. CableAnalyzer. Users Manual

How to accelerate your cabling system approvals

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

LTX Optical Distribution Panels. Ordering Guide

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

1.0 GENERAL. 1.2 SUMMARY.1 Section Includes:

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Section Communications Optical Fiber Backbone Cabling

Data Communications Competence Center

Job Aid Server and CSS Separation Avaya S8700 Media Server

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

NAVSEA STANDARD ITEM. 1.1 Title: Fiber Optic Component; remove, relocate, repair, and install

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Part 1: How to Avoid Confusion When Testing Insertion Loss According to TIA/EIA-568 B.1 and B.3

Understanding Multimode Launching Conditions and TIA TSB-178

Structured Cabling. Product Line Brochure

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

MPS Webinar Technical Series

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

HI-DEX PRODUCT SET DATASHEET

3M 8900 Single-mode SC Crimplok Connector

Project No. # Page 1

Division 27 COMMUNICATION/DATA, PATHWAYS, AND WIRING

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

What really changes with Category 6

SPECIAL SPECIFICATION 6559 Telecommunication Cable

blackbox.com/connect The smart choice when price matters most. Need help? Talk to a Black Box cable expert 24/7 at

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

SECTION 7 -- CROSS-CONNECT SYSTEMS

CATEGORY 6A CABLING SOLUTIONS

Transcription:

RCIT Testing Revised 10/2017 General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from the RCIT Project Engineer prior to commencing testing. RCIT reserves the right to require retesting of any cables tested prior to the Contractor authorization for test commencement at no additional cost to RCIT. 2. All cabling not tested strictly in accordance with these procedures shall be retested at no additional cost to RCIT. 3. 100 percent of the installed cable shall be tested. 4. All Category 6 UTP Cable, Multimode, and Single Mode Fiber Optic Cable tests shall be performed using the Fluke DSX 5000 Versiv CableAnalyzer, no substitute testers are allowed. The Contractor shall verify the Fluke LinkWare software revision installed on the test equipment is the most current available from the cable tester manufacturer (see Fluke Networks Website; http://www.flukenetworks.com) prior to commencing any final cable tests for record. 5. Fluke DSX 5000 Versiv Cable Analyzer and associated modules shall have been calibrated within the previous 12 months. 6. All cables, Horizontal, Intrabuilding Backbone Cable, and Interbuilding Backbone Cable, shall be tested prior to the cutover of voice and data systems to the new cable plant, unless otherwise directed by the RCIT Project Engineer. Complete test results by cable type, including a Summary Report shall be presented to RCIT Project Engineer within three working days. 7. Test results shall be provided in electronic report format using the Fluke LinkWare Cable Test Management Software on a USB Flash Drive. Handwritten test reports are not acceptable. Paper print-outs of complete, individual cable tests are not required unless previously requested in the RCIT Scope of Work. Electronic reports must be accompanied by a Certificate signed and stamped by an authorized RCDD representative of the Contractor warranting the truth and accuracy of the electronic report data. The certificate must reference traceable cable/fiber numbers that match the electronic record. 8. Test reports shall include the following information for each permanent Cat 6 copper cable link or permanent optical fiber link (MM and/or SM) tested: 8.1. Tester manufacture, model, main unit serial number, remote unit serial number, main unit adapter type, remote unit adapter type, software version, calibration date and operator. 8.2. Cable identifier and project/job name. 8.3. Auto test specification used. 8.4. Date and time of test.

8.5. Overall pass/fail indication. 8.6. Wire map results that indicate the permanent cable link tested has no shorts, opens, miss-wires, split, reversed or crossed pairs, and end-to-end connectivity is achieved. 8.7. One copy of the test results will be provided in electronic format on USB Flash Drive. The Summary Report provided by the LinkWare Cable Test Management software program, for both Copper and Fiber tests are the only portion of the test results required in paper format. 8.8. Any individual test that fails a relevant performance parameter shall be marked as a FAIL and the Contractor shall indicate the action taken to correct the problem. 8.9. Overall PASS/FAIL indication for the cable or fiber tested.

Category 6 Data Testing 1. All testing shall be performed in conformance with EIA/TIA 568-C.2 using the permanent link test setup. Cabling shall meet the performance specifications for Category 6 specific to TIA/EIA 568 C.2 1.1. The following equipment is required to perform Category 6 Data Cable Testing with the Fluke DSX-5000 Versiv CableAnalyzer: 1.1.1. DSX-5000 Versiv CableAnalyzer Main and Remote 1.1.2. DSX-5000 CableAnalyzer Modules 1.1.3. (2) Cat6/Class E Permanent Link Adapters 1.2. The DSX-5000 Versiv Cable Analyzer profile will be configured as follows: 1.2.1. Select Home Tab 1.2.2. Select Project Tab 1.2.3. Select CHANGE PROJECT Tab 1.2.4. Select NEW PROJECT Tab 1.2.4.1. Enter Project Name (Department/Address) Verify with RCIT Project Engineer for Assistance. 1.2.5. Select Operator Tab 1.2.6. Select New Test Tab 1.2.7. Select Module: DSX-5000 CableAnalyzer 1.2.8. Select Cable Type: Berk-Tek LANmark-1000 CMP/CMR 1.2.8.1. Verify CNP NVP = 68.0% 1.2.8.2. Verify CMR NVP = 69% 1.2.9. Select Test Limit: TIA CAT 6 Perm. Link 1.2.10. Select Store Plot Data: On 1.2.11. Select HDTDR/HDTDX: Fail/Pass* Only 1.2.12. Select Outlet Configuration: T568B 1.2.13. Select AC Wire Map: Off 1.2.14. Select Save 1.2.15. Select New ID Set Tab 1.2.15.1. First ID: 1A-001A 1.2.15.2. Last ID: 1A-024B (Last Location #) 1.2.15.3. Select Done 1.2.15.4. Select Media: Copper 1.2.15.5. Select Review: Verify ID s are correct 1.2.15.6. Select Save 1.3. Set Reference 1.3.1. Select Home Button 1.3.2. Select Tools Tab 1.3.3. Select Set Reference Tab

1.3.3.1. Connect Main and Remote with Permanent Link and Channel Adapter. (Turn on Main and Remote 5 minutes before the setting reference. 1.3.3.2. Select Test Tab 1.3.3.3. Select Done Tab 1.3.3.4. Select Back Arrow to Exit Tools

Category 6A Wireless Testing 2. All testing shall be performed in conformance with EIA/TIA 568-C.2 using the permanent link test setup. Cabling shall meet the performance specifications for Category 6 specific to TIA/EIA 568 C.2 2.1. The following equipment is required to perform Category 6 Data Cable Testing with the Fluke DSX-5000 Versiv CableAnalyzer: 2.1.1. DSX-5000 Versiv CableAnalyzer Main and Remote 2.1.2. DSX-5000 CableAnalyzer Modules 2.1.3. (2) Cat6/Class E Permanent Link Adapters 2.2. The DSX-5000 Versiv Cable Analyzer profile will be configured as follows: 2.2.1. Select Home Tab 2.2.2. Select Project Tab 2.2.3. Select CHANGE PROJECT Tab 2.2.4. Select NEW PROJECT Tab 2.2.4.1. Enter Project Name (Department/Address) Verify with RCIT Project Engineer for Assistance. 2.2.5. Select Operator Tab 2.2.6. Select New Test Tab 2.2.7. Select Module: DSX-5000 CableAnalyzer 2.2.8. Select Cable Type: Berk-Tek LANmark-10G CMP/CMR 2.2.8.1. Verify CNP NVP = 72.6% 2.2.8.2. Verify CMR NVP = 69.2% 2.2.9. Select Test Limit: TIA CAT 6 Perm. Link 2.2.10. Select Store Plot Data: On 2.2.11. Select HDTDR/HDTDX: Fail/Pass* Only 2.2.12. Select Outlet Configuration: T568B 2.2.13. Select AC Wire Map: Off 2.2.14. Select Save 2.2.15. Select New ID Set Tab 2.2.15.1. First ID: 1A-701A 2.2.15.2. Last ID: 1A-7**B (Last Location #) 2.2.15.3. Select Done 2.2.15.4. Select Media: Copper 2.2.15.5. Select Review: Verify ID s are correct 2.2.15.6. Select Save 2.3. Set Reference 2.3.1. Select Home Button 2.3.2. Select Tools Tab 2.3.3. Select Set Reference Tab

2.3.3.1. Connect Main and Remote with Permanent Link and Channel Adapter. (Turn on Main and Remote 5 minutes before the setting reference. 2.3.3.2. Select Test Tab 2.3.3.3. Select Done Tab 2.3.3.4. Select Back Arrow to Exit Tools

Copper Feed Certification Testing 1. All copper backbone cables shall be tested for shorts, opens, miswires, split, reversed or crossed pairs, and end-to-end connectivity using the Fluke DSX-5000 Versiv CableAnalyzer. 1.1. The Tester should be connected to a commercially available test adapter T568B that allows the connection of the RJ-45 modular plug on the Fluke DSX-5000 Versiv CableAnalyzer to either a 110 termination block, or 66M1-50 termination block as appropriate. Suggested adapter components are: 1.2. Independent Technologies 110 Block Adapter, Independent Technologies Part Number: ITC-3002B, or equal. 1.3. Independent Technologies Universal 66 Block Adapter, Independent Technologies Part Number: ITC-3002C, or equal. 1.4. Testing will verify that all pairs in 4 pair increments for all the pairs in the copper feed cable. 2.4. The following equipment is required to perform Category 3 Data Cable Testing with the Fluke DSX-5000 Versiv CableAnalyzer: 2.4.1. DSX-5000 Versiv CableAnalyzer Main and Remote 2.4.2. DSX-5000 CableAnalyzer Modules 2.4.3. (2) DSX-PC6A CAT 6A Patch Cord Adapter 2.5. The DSX-5000 Versiv Cable Analyzer profile will be configured as follows: 2.5.1. Select Project Tab 2.5.2. Select CHANGE PROJECT Tab 2.5.3. Select NEW PROJECT Tab 2.5.3.1. Enter Project Name (Department/Address) Verify with RCIT Project Engineer for Assistance. 2.5.4. Select Operator Tab 2.5.4.1. Select Name or Select New Operator 2.5.5. Select New Test Tab 2.5.6. Select Module: DSX-5000 CableAnalyzer 2.5.7. Select Cable Type: Cat 3 U/UTP 2.5.8. Select Test Limit: Measure All (1200 Mhz) 2.5.9. Select Store Plot Data: On 2.5.10. Select HDTDR/HDTDX: Fail/Pass* Only 2.5.11. Select Outlet Configuration: T568B 2.5.12. Select AC Wire Map: Off 2.5.13. Select Save

2.5.14. Select New ID Set 2.5.14.1. First ID: 1A/2A-01 Pairs 1-4 2.5.14.2. Select Save 2.5.14.3. Select Home 2.5.15. Save all tests (ex. 1A/2A-01 PAIRS 1-4, 1A/2A-01 PAIRS 5-8, 1A/2A-01 PAIRS 9-12, 1A/2A-01 13-16, 1A/2A-01 PAIRS 17-20, 1A/2A-01 PAIRS 21-24, 1A/2A-01 PAIRS 22-25 for a 25 pair cable)

Fiber Certification Testing 1. The Contractor shall be responsible for testing every strand of each Intrabuilding and Interbuilding fiber optic backbone cable. 1.1. RCIT typically does not specify installations that leave fibers unterminated, (dark fibers) therefore, all strands in each cable shall be terminated, mounted in a fiber distribution/patch panel, labeled and tested. 1.2. The installed fiber link(s), each consisting of two (2) fibers/strands (Tx and Rx). Multimode fiber will be tested as specified by TIA/EIA-568.3-D and ANSI/TIA/EIA 526-14-C Method A. Singlemode fiber will be tested as specified by TIA/EIA-568-B.1.7.1 and ANSI/TIA/EIA 526-7 Method A.1. NOTE: Method A Encircled Flux one jumper reference using Fluke TRC s. 1.3. The following tests apply for both multimode and single mode fiber cables. 1.4. The testing procedure for each fiber optic strand is as follows: 1.5. Perform end-to-end, bi-directional power loss tests at 850nm and 1300nm wavelengths for multimode, and 1310nm and 1550nm for singlemode fibers. NOTE: The Fluke DSX-5000 Versiv CertiFiber Pro is capable of testing fiber links in both directions from one termination location. The CertiFiber Pro will prompt the Operator to switch cable connectors (at the panel connector adapter/bulkhead) at the Near End and Far End Testing when the Tester is ready for Far End to Near End testing to be accomplished. 1.6. The following maximum allowable Loss budgets apply for cable and connectors: 1.6.1. Fusion Splices: Maximum allowable Loss (attenuation) per spliced strand: 0.2dB 1.6.2. Connectors: Maximum allowable Loss per mated connector pair: 0.50dB 1.6.3. Fiber: Maximum allowable attenuation for each fiber strand shall not exceed the calculated maximum Loss rating based on performance as stated by manufacturer of the cable under test. 1.7. If a fiber strand of a cable run exceeds the calculated maximum power loss, as measured by the Fiber Loss tests, the fiber strand shall then be tested with the Tester configured with the Fluke DSX-OTDR Module to

determine whether it is the fiber strand, fusion splice(s) or the connector, that exceeds the power loss margin. 1.8. If the connector exceeds the power loss margin, then re-terminate the connector and repeat the testing procedures above. 1.9. If the fusion splice exceeds the power loss margin, break the splice, resplice and retest. 1.10. If a fiber strand in the cable exceeds the specified power loss budget, then the contractor shall notify the RCIT Project Engineer as soon as possible to determine the impact of cable replacement on the Project Schedule. RCIT and the Contractor will devise a plan to procure new materials and replace the faulty cable. 1.11. Record and document the length and power loss readings in relative decibels (db) for every strand. Indicate as part of the testing documentation those runs that exceeded the power loss margins and the action taken (re-pulling the cable, re-polishing or re-terminating the connector). 2. The following equipment is required to perform Fiber Optic Cable Testing with the Fluke DSX-5000 Versiv CableAnalyzer: 2.1.1. DSX-5000 Versiv CableAnalyzer Main and Remote 2.1.2. (2) DSX-5000 CertiFiber Quad Pro OLTS Modules 2.1.3. (2) USB Fiber Inspection Video Probe 2.2. The DSX-5000 Versiv Cable Analyzer profile will be configured as follows: 2.2.1. Select HOME Button 2.2.2. Select PROJECT Tab 2.2.3. Select CHANGE PROJECT Tab 2.2.4. Select NEW PROJECT Tab 2.2.4.1. Enter Project Name (Department/Address) Verify with RCIT Project Engineer for Assistance. 2.2.5. Select Operator Tab 2.2.5.1. Select Name or Select New Operator 2.2.6. Select New Test Tab 2.2.7. Select Module: Certifiber Pro-Quad 2.2.8. Select Test Type: Smart Remote 2.2.9. Select Bi-Directional: On 2.2.10. Select Fiber Type: 2.2.11. Select More: 2.2.12. Select More: 2.2.13. Select Manufacturers: 2.2.14. Select Corning: 2.2.14.1. Berk-Tek Tight Buffered Armored OM3 MM Indoor/Outdoor = GIGAlite 10-EB-OM3

2.2.14.2. Berk-Tek Tight Buffered Armored OS2 SM Indoor/Outdoor = Single-Mode AB OS1/2 2.2.14.3. RC3 - Corning Pretium Edge PNP Trunk = ClearCurve Multimode OM3 2.2.14.4. 2.2.15. Select Test Limit: 2.2.15.1. OM3 MM Indoor/Outdoor = TIA-568.D Multimode (STD Grade) 2.2.15.2. OS1/2 SM Indoor/Outdoor = TIA-568.D Singlemode OSP (STD Grade) 2.2.15.3. RC3 Data Center Pretium PNP Trunk = 100GBASE-SR4 2.2.16. Select Reference Method: Verify 1 Jumper Reference 2.2.17. Select Connector Type: SC, LC 2.2.18. Select No. of Connectors/Splices: Verify # of Total Connections (Mated Pairs, RC3 Cassette = (1) Mated Pair) The # of mated pairs will change the total loss budget and change the test limits of the cable under test. 2.2.19. Select: Save 2.2.20. Select New ID Tab 2.2.20.1. Enter First ID: 1A-A1-A/1B-A1-A:01 2.2.20.2. Enter Last ID: 1A-A1-A/1B-A1-A:24 (Last Location #) 2.2.20.3. Select Done 2.2.20.4. Media: Fiber 2.2.20.5. FiberInspector: No 2.2.20.6. Loss/Length: Check 2.2.20.7. Select Review: Verify ID s are correct 2.2.20.8. Select Save 2.2.21. Select Home Button 2.2.22. Select Set Reference Tab 2.2.22.1. Clean Fiber Connectors on TRC (Test Reference Cords) with fiber cleaning wand for appropriate connector type 2.2.22.2. Connect Fiber Inspector to USB Port and inspect TRC (Test Reference Cord) verify fiber connectors are clean. 2.2.22.3. Select Run Wizard 2.2.22.4. Follow directions on screen 2.2.22.5. Connect a TRC (Test Reference Cord) to each output port Red connector connects to output port (Use TRC for patch panel type ST, SC or LC. If required change output port to required connector type SC or LC. 2.2.22.6. Select Next 2.2.22.7. Select Set Reference 2.2.22.8. Select Next 2.2.22.9. Follow directions and install 2 nd TRC cord to input ports with SM Reference Couplers 2.2.22.10. Select Next

2.2.22.11. Verify TRC cords pass TRC Verification (if not clean and retest)