TPC R&D at Cornell and Purdue

Similar documents
The Cornell/Purdue TPC

ILC Detector Work. Dan Peterson

Tracking Detector R&D at Cornell University and Purdue University

TPC R&D by LCTPC. Organisation, results, plans. Jan Timmermans NIKHEF & DESY(2009) On behalf of the LCTPC Collaboration TILC09, Tsukuba

The field cage for a large TPC prototype

The Large TPC Prototype: Infrastructure/ Status/ Plans

GEM-TPC development in Canada. Dean Karlen Technology recommendation panel meeting January 16, 2006 KEK

Towards mass production of MICROMEGAS (Purdue/3M) Jun Miyamoto, Ian Shipsey Purdue University

Update on Mass Produced Micro Pattern Gas Detectors. Operation of GEMS in Negative Ion Gases (Purdue/Temple/WSU)

Status of GEM-based Digital Hadron Calorimetry

R&D plan for ILC(ILD) TPC in (LC TPC Collaboration)

Front end electronics for a TPC at future linear colliders

A Review of Tracking Sessions

Drift Tubes as Muon Detectors for ILC

Study of the Z resolution with Fit Method for Micromegas TPC

Beam test of the QMB6 calibration board and HBU0 prototype

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

TPC R&D, Tasks towards the Design of the ILC TPC

The Time-of-Flight Detector for the ALICE experiment

High ResolutionCross Strip Anodes for Photon Counting detectors

PMT Gain & Resolution Measurements in High Magnetic Fields

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC

New gas detectors for the PRISMA spectrometer focal plane

DEPFET Active Pixel Sensors for the ILC

Beam Test Results and ORCA validation for CMS EMU CSC front-end electronics N. Terentiev

MCP Upgrade: Transmission Line and Pore Importance

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment. Gianluigi Cibinetto (INFN Ferrara) on behalf of the BESIIICGEM consortium

CESR BPM System Calibration

Calibration of photomultiplier tubes for the large-angle beamstrahlung detector at CESR

TORCH a large-area detector for high resolution time-of-flight

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

CGEM-IT project update

HAPD and Electronics Updates

TG 3 Status Report. C. Cattadori on behalf of TG3

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Front End Electronics

Digital Hadron Calorimetry for the Linear Collider using GEM based Technology University of Texas at Arlington, University of Washington

BEMC electronics operation

Progress Update FDC Prototype Test Stand Development Upcoming Work

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

The hybrid photon detectors for the LHCb-RICH counters

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

A new Scintillating Fibre Tracker for LHCb experiment

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

Results on 0.7% X0 thick Pixel Modules for the ATLAS Detector.

SuperFRS GEM-TPC Development Status Report

Large Area, High Speed Photo-detectors Readout

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

Riccardo Farinelli. Charge Centroid Feasibility

SciFi A Large Scintillating Fibre Tracker for LHCb

Review of the CMS muon detector system

RTPC 12 Simulation. Jixie Zhang Aug 2014

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab

Surface Screening with the BetaCage

TIME PROJECTION CHAMBER

Outline. GEM R&D and assembly facilities at UVa. Cosmic test results. Update on the cm 2 GEM prototype

The Silicon Pixel Detector (SPD) for the ALICE Experiment

arxiv:hep-ex/ v1 27 Nov 2003

An extreme high resolution Timing Counter for the MEG Upgrade

!"!3

ISC0904: 1k x 1k 18µm N-on-P ROIC. Specification January 13, 2012

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Rome group activity since last meeting (4)

Hamamatsu R1584 PMT Modifications

ALICE Muon Trigger upgrade

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER

Beam Loss Detection for MPS at FRIB

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

A FOUR GAIN READOUT INTEGRATED CIRCUIT : FRIC 96_1

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

Table. J. Va vra,

Updates on the Central TOF System for the CLAS12 detector

The FEL detector development program at DESY. Heinz Graafsma DESY-Photon Science Detector Group WorkPackage Detectors for XFEL

Overcoming Challenges in 3D NAND Volume Manufacturing

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

with Low Cost and Low Material Budget

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

R&D on high performance RPC for the ATLAS Phase-II upgrade

The Status of the ATLAS Inner Detector

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

PACS. Dark Current of Ge:Ga detectors from FM-ILT. J. Schreiber 1, U. Klaas 1, H. Dannerbauer 1, M. Nielbock 1, J. Bouwman 1.

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

Dick Loveless. 20 November 2008 SLHC Workshop. Dick Loveless SLHC Workshop 20 Nov

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Subj: General MTI2000 and Piezo Task Setup and Operation. High-Voltage Displacement Meter (HDVM) Configuration.

Progress on the development of a detector mounted analog and digital readout system

Transcription:

TPC R&D at Cornell and Purdue Cornell University Purdue University T. Anous K. Arndt R. S. Galik G. Bolla D. P. Peterson I. P. J. Shipsey J. Ledoux Further information available at the web sites: http://www.lepp.cornell.edu/~dpp/linear_collider/large_prototype.html http://www.lepp.cornell.edu/~dpp/linear_collider/tpc_test_lab_info.html ll / d /li llid /t t t l i l * presentation at LCWS DESY 30-May-2007 Bulk Micromegas * presentation at ECFA Valencia 07-November-2006 electron and ion transmission * presentation at ALCPG Vancouver 18-July-2006 demonstration of ion signal * presentation at Berkeley TPC Workshop 08-April-2006 Purdue-3M Micromegas * presentation at ECFA 2005 Vienna 24-November-2005 * presentation at ALCPG Snowmass 23-August-2005 * presentation at LCWS05, Stanford 21-March-2005 This project is supported, in part, by the US National Science Foundation (LEPP cooperative agreement) and by the US Department of Energy (Purdue HEP group base grant) and an LCDRD consortium grant (NSF and DoE). This project is in cooperation with LC-TPC. 1

in this talk - Measurements using the small prototype TPC at Cornell a comparison of a Bulk Micromegas, B=0, Ar-isoC 4 H 10 (7%) a Purdue/3M Micromegas,B=0, Ar-isoC 4 H 10 (7%) a triple-gem, B=0, TDR gas:ar-ch 4 (5%)-CO 2 (2%) at B=0 same chamber, pads, readout, analysis - The endplate for the LC-TPC Large-Prototype status of design plans for production 2

TPC 14.6 cm ID field cage - accommodates a 10 cm gas amplification device 64 cm drift field length 22.2 cm OD outer structure (8.75 inch) field cage termination and final return lines for the field cage HV distribution allow adjustment of the termination bias voltage with an external resistor. Read-out end: field cage termination readout pad and gas amplification module pad biasing boards CLEO II cathode preamps 3

Electronics High voltage system: -20 kv module (for the field cage) +4 kv module (GEM and Micromegas) -2 kv module (wire gas amplification) Readout: VME crate PC interface card LabView Struck FADC 88 channels 105 MHz (usually run at 25 MHz) 14 bit +/- 200 mv input range ( least count is 0.025mV ) NIM external trigger input circular memory buffer 4

TPC pad board Pad board with 2 mm pads. 80 pads on the board 4 layers of 2mm pads Resolution measurements are derived from the difference in residuals on adjacent 2mm pad rows. 5 layer of 5mm pads for track definition 5

Bulk Micromegas amplification 10 cm The bulk Micromegas, was prepared on one of our pad boards by Paul Colas Saclay group. The device is a mesh supported by deposited d insulators, 50 μm. 6

Bulk Micromegas amplification The Micromegas is located 0.78 cm from the field cage termination. HV is distributed to the pads; note blocking capacitors, HV resistors. Low voltage signals routed to preamps outside (on ribbon cable). Micromegas is at ground; pads at +410V for Ar-isoC 4 H 10 (7%). Bulk Micromegas measurements, Ar-iso C 4 H 10 (7%), were shown at DESY 2007. Current measurements have fully instrumented pad board and higher statistics. 7

Purdue-3M Micromegas amplification 10 cm Measurements with the Purdue-3M Micromegas, using Ar-CO2 (10%) were shown at Vancouver 2006. Current measurements are with Ar-iso C 4 H 10 (7%), 400V. 8

Purdue-3M Micromegas Micromegas is commercially made by the 3M corporation in a proprietary subtractive process starting with copper clad Kapton. This is a very different design with respect to the Bulk Micromegas. Holes are etched in the copper 70 mm spacing 35 mm diameter 70 μm Copper thickness: 9 μm 1 mm Pillars: remains of etched Kapton. 50 μm height 300 μm diameter at base 1 mm spacing, square array The shiny surface of the pillars is due to charge build-up from the electron microscope. 9

Triple-GEM amplification 10 cm triple-gem 315V/GEM 3 transfers.165cm, 2300V/cm, Pads @ +2100V We typically run at very low gain: gain estimation : taking gain of single-gem = 70 @ 380V running 55V lower; scale gain by 10 ΔV/60 single-gem gain is 8.5 triple-gem gain is ~600?? 10

Charge width / diffusion The charge width is extracted from the fraction of the total charge observed on 1,2 or 3 pads, shown above, assuming a gaussian charge distribution. ( The charge-fraction measurement in 1 and 2 pad saturates at small fraction. In that case, the highest charge-fraction is artificially high. ) The line indicates a diffusion constant of D=.0390 cm/(cm) 1/2. ( The measured width, and diffusion constant, may be reduced by the loss of small signals due to the opposite-sign pick-up, described in an earlier talk.) Also indicated are the number of pads that are typically contributing to a signal, indicating the number of pads that will be used in the spatial measurements. 11

Gas property: Charge width / diffusion this Colas, measurement Vienna, 2005 iso C 4 H 10 7% 5% E drift V/cm 200 220 D cm/(cm) 1/2 0.039 0.0480 this Karlen, measurement Snowmass 2005 E drift V/cm 220 230 D cm/(cm) 1/2 0.038 0.0348 σ o mm 0.83 0. 918 12

Drift velocity / Gain Ar-CH 4 (5%) CO 2 (2%), 220V/cm, expect 43 mm/μs. Observed time for a maximum drift 64.7 cm is (370 FADC time buckets)x(40ns/bucket), or 43.7 mm/μs. Ar-isoC 4 H 10 (7%), 200V/cm, expect ~39 mm/μs. Observed time for a maximum drift 64.7 cm is (405 FADC time buckets)x(40ns/bucket), or 39.9 mm/μs. Various sources The gas gain of the triple GEM, 315V/GEM is estimated at ~ 600. The relative gains are readily determined from the average pulse heights. Bulk Micromegas (7% C 4 H 10, 410V) =0.81 3-GEM (Ar-CH 4 (5%) CO 2 (2%), 315V/GEM) Purdue Micromegas (Ar-isoC 4 H 10 (7%), at 400V) = 3.6 Bulk Micromegas (7% C 4 H 10, at 410V) correcting by x10 per 60V, gain ratio (equal V)=5.3 13

hit resolution (2mm pad) find tracks require time coincident signals in 7 layers there are 9 layers available: require 3 2mm-pad layer (average is > 3.9) find PH center using maximum PH pad plus nearest neighbors (total 2 to 4 pads) fit, deweighting the 5mm pad measurements Here, the containment width of the pad distribution function is small; any sharing indicates that the charge center of each pad is not the geometric center. Thus, there is a shift of the effective pad center. point measurement low drift (narrow pad distribution function) hits are corrected for an effective pad center (This is not ideal, but it is what we are currently using.) plot the resolution difference extract the RMS of difference-in-residualsin residuals for adjacent 2mm layers pairs extract point resolution σ σ = RMS / 2 14

cuts, calibration slope < 0.05 the trigger allows ~ 0.08 x < 11 mm removes poorly measured edge tracks residual in the single (2mm) layer < 0.4 mm requires consistent hits in adjacent 5mm layers although it is higher weighted in the fit fraction of signal in 1 pad < 99% much looser than previous analysis fraction of signal in 2 bins > (drift distance dependent ) removes events with significant noise distorting position measurement Pad-to-pad pulse height calibration ( as large as ± ~30% ) 15

Hit resolution triple-gem at 315V bulk Micromegas The results are at gain=81% of that very similar. of the triple-gem The fit is to the data, with same conditions, shown at LCWS DESY 2007 Fit to σ=(σ 02 + D 2 /n x) 1/2 use D=.0415 cm/(cm) 1/2. result: n=17.4 ±.5 σ 0 = 53 ±36 μm χ 2 /dof = 1.7 16

Hit resolution The resolution for the Purdue-3M Micromegas is compared to that of the Bulk Micromegas. While the gain of the Purdue-3M device is 3.6 x that of the Bulk Micromegas, the resolution is significantly worse. The charge width (diffusion) was the same. Presumably, there is a loss of statics due to transmission. 17

small TPC : summary, outlook We show measurements of a Bulk Micromegas, Purdue-3M Micromegas, triple-gem. same TPC, pads, readout analysis We are continuing preparations for comparative ion feed-back measurements. (graduate student) All measurements have been at B=0. We are planning a run at 1.5 T CLEO running will end April 2008 (after 28.5 years). Cornell proposes to reconfigure CESR for studies of a wiggler-dominated damping ring. If this proposal p is funded, we will remove the CLEO ZD (5 years) and drift chamber (9 years) from solenoid as part of the CESR reconfiguration. This will open space in the CLEO magnet for a small prototype run at 1.5 Tesla. ( 4 weeks /year, maximum) 18

LC-TPC Large Prototype The LC-TPC collaboration is constructing a large prototype to study - issues related to tiling of a large area - system electronics - calibration methods - track finding in a large scale Micro-Pattern-Gas-Detector based readout. 60 cm drift length 80 cm diameter It is a cut-out region of an ILC TPC This chamber will be operated at The EUDET facility, at DESY, starting in 2008 19

LC-TPC Large Prototype Cornell responsibility - endplate - mating module frames requirements - dimensional tolerances - minimal material -maximum instrumented t area Endplates are being designed in coordination with the field cage at DESY and meeting the module requirements for Micromegas modules (Saclay) and GEM modules (Saga) 20

LC-TPC Large Prototype The geometry has been defined by the collaboration. All modules will extend to a common distance into the field cage (28mm). The drift field will end at this point, the 5 th field band. There are 4 band (additionally 5 bands in the outer layer) used for field termination shaping. 21

LC-TPC Large Prototype Drawing have been prepared and sent to vendors for bidding (October 19). The endplate provides (7) identical locations for module installation. i The details for the installation hole are defined once. Then the locations are defined. 22

LC-TPC Large Prototype The module back-frame (or red thing ) drawing have been completed (October 22). An initial run of (2) each, GEM and Micromegas, will be make in the LEPP shop next week. These will allow production of the first modules. 23

LC-TPC Large Prototype y x The mechanical tolerances, driven by the need to decouple position and B field calibrations, require that we define a machining process to minimize internal stresses. A series of test plates were used to final study warping is various processes. 1) machine to 750 mm (0.030 inch) oversize, 2) stress relief (rapid immersion in liquid N 2 ) 3) machine to 250 mm (0.010 inch) oversize, 4) stress relief (rapid immersion in liquid N 2 ) 5) machine to drawing dimensions 24

LC-TPC Large Prototype The o-ring seal design was tested for leaking; the design provides satisfactory protection from oxygen contamination. A test plate was loaded with 2.6 millibar. Deformation was 7 μm. The frames will be strengthened with a small increase in the stiffening wing 25

LC-TPC Large Prototype Design of the LC-TPC Large Prototype 1 endplate is ready for vendor selection. The design can be finalized during the selection process. The module back-frames are ready for production. 26