E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Similar documents
E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

E3C-LDA. Phone: Fax: Web: - Operating Procedures: Photoelectric Sensors

Main Display (Red) Displays the incident light level or the function name.

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection.

The Latest VT-WIN II for High-precision Inspections

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Separate Thin Amplifier type. AP-V40AW Series

VT-S730. Omron's 3D-SJI For Efficient Manufacturing of High-quality Products. Best the Minimum Q cost! PCB Inspection System VT-S730 NEW

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Electrical connection

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Electrical connection

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Electrical connection

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

SU17 Series Fiber Optic Sensors

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

USER MANUAL. VP-435 Component / UXGA HDMI Scaler MODEL: P/N: Rev 13

Digital Real Time Recording VCR

Operating Instructions

E3X-DAC-S Digital Fiber Sensor

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing

C200H-AD002/DA002 Analog I/O Units Operation Guide

DTL-4800P. Digital Real Time Recording VCR

TABLE OF CONTENTS. Instructions:

Safety Light Curtains

About... D 3 Technology TM.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Multi-functional safety relay modules PROTECT SRB-E

USER MANUAL. VP-425 PC / Component to HDMI Scaler MODEL: P/N: Rev 3

Please read and keep this manual. It contains important information on the safe and proper use of your X2VGA Plus High Definition VGA Pack.

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Operating instructions Capacitive level sensor KNQ

7.5ft Outdoor Double-Sided Interactive LCD Sign, Transit Center Kiosk Model: NISDK-550PCT, 55 Double-Sided

DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual

Amplifier for fiber optics. Dimensioned drawing

Warner Photoscanner MCS-500 Series LED Photoelectric Control

SCALE & WEIGHT DISPLAYS

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

LCD Display Wall Narrow Bezel Series

Models available for a wide variety of applications at manufacturing sites. 20mm 10mm

Electrical connection

2 outputs + 1 input. Connector for Sensor Communications Unit. Sensing method Appearance Sensing direction Size Model

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

Light Curtain Type LA

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

V9A01 Solution Specification V0.1

NKCR.E Auxiliary Devices. Auxiliary Devices

Eddy Current Technology. eddyliner. digital

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

USER MANUAL. VP-426 HDMI-PC Scaler MODEL: P/N: Rev 4.

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

USER MANUAL. VP-422 HDMI to PC Scaler MODEL: P/N: Rev 5

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Lt DELTA USA, Inc

INPUT OUTPUT GAIN DELAY. Hue Candela Strobe Controller. Hue Candela s STROBE CONTROLLER. Front Panel Actual Size 7 ¼ By 4 ¾ POWER. msec SEC 10 1.

PRODUCT BROCHURE. Broadcast Solutions. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

CS24D Color Sensors a.

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Doteck 4K Series. 6G-SDI UHD Video fiber optic Transmission System

6G-SDI. Digital Video fiber. optic Transmission System

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Basic Information Before Use. Display on LCD Screen. Distinction by. Patterns Recognition. Use of Applied Functions. Changing Set Value

XCOM1002JE (8602JE) Optical Receiver Manual

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Photoelectric Sensors E3F2

High-Definition Scaler. GTV-HIDEFS. User Manual

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

ED5229GT-E Series. Page 1 of 8

PDP ORION PDP CO., LTD.

NT-9600 Wireless Barcode Scanner. Introduction

Process transmitter RMA422

013-RD

True Color Sensor with Analog and Digital Outputs

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Gamma instabus. Technical product information

Owner s guide How to use your new Opalum Furniture Sound System

60 ± 10 mm 4. (See Note.) PNP E3MC-X ± 4mm 4 NPN E3MC-MX11. (See Note.) PNP. mended. fiber. 4 NPN E3MC-MY11 E32-T16

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

REGO Start&Go USER MANUAL

Generator protection relay

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-434 Component/UXGA HDMI Scaler. P/N: Rev 6

Transcription:

E3X-DA-S Digital Fiber Sensors Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Evolution and Perfection The next-generation platform for a wide range of sensing The industry's first Power Tuning function in a digital sensor. Large, Easy-to-Read Displays that are clear even from a distance. Seven convenient display formats. Stable long-term performance achieved with OMRON's Auto Power Control (APC) function. A wide array of Advanced Functions for even more applications. The same Ease-of-Use as the E3X-DA-N Amplifier. Environmentally Friendly design. Improved Mobile Console. 2

3

No complicated mode settings. Troublesome power adjustments have been eliminated, so it isn t necessary to select from power mode settings, such as long-distance mode, standard mode, and short-distance mode. When the MODE Key is pressed once, the power tuning function shifts the power level so that the present incident level is set to the ideal level (2000 on the digital display.) Earlier Method High-speed mode Short-distance mode Threshold level Incident insufficient Appropriate New Method Patent Pending Press No power modes Up to 5-fold increase Standard mode Long-distance mode Super-long-distance mode Appropriate Saturated Saturated The best mode for each application was selected from several power modes. Up to 1/25 reduction The Sensor can be used immediately without setting the mode. If the incident light level is too high or too low, just press the Mode key to achieve the optimum status. Insufficient light or saturation at short distances can be corrected. The power tuning range is extended to the allowable limits to eliminate problems such as insufficient light or detection failures due to saturation. If the installation distance is too short, the incident light may saturate (i.e., to a digital incident level of 4,000), preventing detection. The power can be tuned down to 1/25th of the default setting for stable detection even at close range. Press Without workpiece Transparent workpiece does not change. changes. With workpiece Detection is not possible Detection is possible. Variations between different Sensors can be eliminated. Threshold levels had to be set and maintained separately for individual Sensors due to variations in the digital light levels measured by each Sensor. With power tuning, the incident level can be fine-tuned so the same threshold level can be set for each Sensor in an application. Maintenance is also simplified because it is easier to recognize measurement levels that have shifted during operation. Earlier Method New Method Press Detecting missing tablets Digital light levels vary due to individual differences in the Sensors, so the threshold levels must be set individually. All of the Amplifiers are set to the same digital light level, so the same threshold level can be set and maintained for the Sensors. 4

Large, Easy-to-Read Displays: Clear Even from a Distance The displays are large and easy-to-read, despite the small case. Large, bright operation indicator (like earlier models) Threshold level RUN mode Settings can be made more simply and confidently with two digital displays. For example, the threshold value can be changed while reading the incident level or a setting can be changed while confirming the setting s function item number. Industry s largest characters: 6 mm (like earlier models) Power tuning indicator added to indicate setting status. Function Setting SET mode Function numbers added to function items. Settings are now reversible. Seven Convenient Display Formats Patent Pending An incident level/threshold display, percentage/threshold display, and large bar graph display have been added, so you can select the best display method for the application. Incident Level/Threshold Display Percentage/Threshold Display Large Bar Graph Display Incident light No incident light Threshold level Threshold level Change the threshold level while reading the incident level. Verify the difference between the incident level and threshold level while setting the threshold level. Bar display Check the incident level intuitively. Ideal when it is better to view an analog display instead of the actual digital level. Incident Level/Peak Hold Display Peak Hold/Bottom Hold Display 2010 2055 Peak hold Threshold level 1350 1280 Simultaneously display the peak hold level and present incident level. The optical axis can be adjusted more easily and surely by checking the peak hold level while adjusting the optical axis. Display the peak level when light was brightest and bottom level when light was dimmest. The digital levels of high-speed objects can be read precisely. (Refreshing the hold level was changed from a fixed time to synchronizing with the output, so the peak and bottom hold values can be checked with certainty.) 5

Stable, Long-term Performance with OMRON s APC Function OMRON provides the industry s most stable long-term detection by using new 4-element LEDs and an APC (Auto Power Control) circuit. In addition to our unique APC circuit used in the E3X-DA-N Amplifiers to compensate for the deterioration of the LED, the E3X-DA-S uses 4-element LEDs to counteract the deterioration of the light-emitting elements over time and achieve the industry s most stable long-term detection performance. Furthermore, the circuit is designed with excess light capacity, so the Sensors can be used with high stability regardless of whether the APC circuit is ON or OFF. Earlier Method 3-element LED and APC Without APC circuit Highest Level of Stability New Method 4-element LED and APC Long-term stability Without APC circuit Compensate for the effects of contaminants and temperature variation with differential operation mode. (Advanced Models) This operation mode uses a special OMRON algorithm to compensate for slight light level changes due to dirt or temperature variations and detect only the light level changes due to the workpiece. Slight light level changes can be detected with stability and precision, eliminating the need for time-consuming manual adjustments for light level changes. With the Twin-output Amplifiers, output 2 can function as an alarm output (light level operation) to indicate when the light level has changed due to dirt or other causes. Patent Pending Detecting marks in a dusty environment Light Level Operation (Normal Operation) Judges light level changes by comparing the incident level and threshold level. Differential Operation Judges light level changes by comparing the incident level to a time-averaged incident level. Threshold level (absolute value) Alarm output Detecting knots in thread Incorrect operation due to light level change The light level varies due to dirt, temperature variations, or other environmental factors. Alarm output threshold Light level difference (absolute value) Detecting differences in the light level enables setting more subtle light level differences. Incorrect operation Minute changes are detected reliably. 6

Many Advanced Functions for Even More Applications In super-high-speed mode, it is the fastest digital model at 48 s. (Standard Models) Fastest in the Industry Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times. Detecting Leads on Electronic Parts Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s. A one-shot timer is supported in addition to the ON-delay and OFF-delay timers. The Amplifier s ON time can be fixed, which is useful during high-speed workpiece detection. Area output function can be used for range judgement. (Advanced Twin-output Models) Area output Incident level 2000 Threshold 1 Discriminating Tablet Lengths Operations that required multiple Sensors, such as height measurement, can be performed with just one Sensor. Two threshold levels can be set to easily output within-range and out-of-range outputs. 1000 Output ON Threshold 2 OFF Remote input function can control the Sensor remotely. (Advanced External-input Models) Input signals can make various remote settings, such as teaching operations, power tuning, and emitter OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation or making settings remotely because teaching has to be performed often for frequent workpiece model changes. Detecting Seals The counter function can output signal after counter counts up or down. (Advanced External-input Models) Up Counter A counter function is built-in, so the number of workpieces can be counted without a separate counter or small PLC that used to be required. Incident level Counter Function Incident level Patent Pending Down Counter Threshold level Detecting Chip Components Counter Counter Counter value Output when count reaches SV. Output when count reaches 0. 7

The Same Ease-of-Use as the E3X-DA-N The E3X-DA-S uses OMRON s own simplified wiring connectors that were introduced with the E3X-DA-N. Patent Pending Japan patent number 3266198 In Amplifiers with Connectors, the power supply is distributed to slave connectors through a single master connector. This design has three major advantages. 1. Wiring time is significantly reduced. 2. Relay connectors are unnecessary, so wiring takes up less space. 3. Storage and maintenance are simpler because it isn t necessary to distinguish between master connector and slave connectors on the Amplifier. Simplified Connector Design Up to 16 Amplifiers can be connected. Master connector Optical communications Power supply pin Slave connector Reduced Power Wiring Saves Space <Using 5 Amplifiers> Connector models Prewired models Streamlined wiring Relay connectors Relay connectors not required. Output lines only Power line Eliminate the installation time, cost, and space associated with relay connectors. Output lines only Power line Power is supplied from the master Amplifier Unit to the slave Amplifier Units through the Master Connector. 7 cables Separate power lines and output lines are required for each Amplifier. 15 cables Optical communications prevents mutual interference. Mutual interference is prevented with optical communications, so up to 10 Amplifiers can be mounted together. (The number of Amplifiers depends on the operating conditions.) Close-mounting of up to 10 Sensors Optical communications Up to 10 Amplifiers Zero reset function immediately resets the digital display to 0. With Workpiece Without Workpiece Patent Pending Japan patent number 3255229 The zero reset function can immediately reset the digital display to 0 at any time. By setting the reference value to 0, the threshold value can be set while monitoring differences in incident light levels. The threshold value will also shift simultaneously when the zero reset button is pressed. Shift difference = 700 Threshold level set to 350. Zero reset Display reset to 0. Reversible Digital Display (Reverse Mode) The digital display can be reversed to match the Amplifier s mounting direction. Standard mode Selectable Reverse mode 8

Environmentally Friendly Design Environmentally friendly features are essential in truly high-performance products. 1 Materials containing lead have been completely eliminated. The Fiber Sensor is the first in the industry to use environmentally friendly lead-free solder. First in the industry No lead! This ECO label is indicated on produts that meet the environmental standards established by OMRON. Pb 2 The digital display can be turned OFF or dimmed during operation. Eco-mode When the digital display is viewed infrequently during operation, current consumption can be reduced by dimming the display or turning it OFF entirely. The display will light up again automatically when an operation key is touched. (Ecomode can be set from the Mobile Console only.) Display not lit. Lights up if an operation is performed. During operation (After 30 s without an operation) Dimmed display Lights up if an operation is performed. During operation (After 30 s without an operation) 3 Cable disposal is not required during maintenance. In addition to saving space and reducing wiring time, the new connector design eliminates the need to dispose of cables together with the Amplifiers. Cable disposal is not necessary. 9

Further Improvements to the Mobile Console Can also be used with Photoelectric Sensors with Separate Digital Amplifiers. E3X-DA-S Digital Fiber Sensor Group Power Tuning With the group power tuning function, power tuning is possible for multiple Sensors at the same time. E3X-MC-S Mobile Console E3C-LDA Photoelectric Sensor with Separate Digital Amplifier Easily set multiple Sensors. Group Power Tuning Improved Mode Lock Function Settings can be customized for different applications by locking out unnecessary function blocks within function settings. The Age of Usercustomizable Sensors. Function Block Application Manual setting Teaching Function setting Manual Set for manual operation. Operation OK Locked Locked Teaching Set for teaching operation. Locked Operation OK Locked Teaching + Manual Set for teaching + manual operation. Operation OK Operation OK Locked 10

Retains all of the Previous Advantages of the Mobile Console. New and Improved Fiber Sensor and Mobile Console. Settings, teaching, and fine-tuning can be performed at the fiber tip. The Mobile Console can be used for settings and teaching at the tip of the fiber. Difficult adjustments can be made while checking the workpiece position. Even if the Amplifier and Sensor head are separated during operation, it is still possible to flash the Sensor head and display the amplifier channels. Channel 5 Channel 4 Channel 3 Channel 2 Channel 1 With Group Teaching, Teach Multiple Amplifiers Simultaneously. Group teaching The tedious teaching that had to be performed separately for each Amplifier can now be performed for several Amplifiers at once using the Mobile Console. Copying Settings within the Same Group Copy channel 1 s contents to all channels. Channel 1 Channel 1 All channels Channel 2 Channel 5 Settings such as mode or threshold settings in an Amplifier or bank can be copied to all of the Amplifiers in the same group. Copying Settings to Other Groups All of the group s settings are copied. Machine A The settings for a group of Amplifiers on one machine can be copied to a group of Amplifiers on another machine. (The settings can also be copied to and from banks.) Machine B Machine D 11

OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit, Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON CHINA CO., LTD. BEIJING OFFICE Room 1028, Office Building, Beijing Capital s Square, No. 88 West Chang an Road, Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 In the interest of product improvement, specifications are subject to change without notice. Authorized Distributor: Cat. No. E335-E1-01 Printed in Japan 1102-?M (?)