24Hour/7Day Electronic Timeswitch

Similar documents
16 Amp Electronic 24 Hour/7 Day Time Controller

7 Day Digital Light Switch with Optional Dusk Start

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Time Switch

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

7 Day Digital Programmer 3 Channel Surface Mount

Digital Economy Seven Programmer

2 Hour Electronic Boost Timer

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

7 Day Digital Programmer

1. General Information:

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

1 Channel Multi-Purpose Programmer User Instructions

WiFi Controlled Fused Spur Time Switch

Instruction Manual for Programmable Digital Timer

XTM72E & F Real-Time Clock Modules

Operating Instructions


CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

Radio Thermostat Clock

TDDFM14 OWNER S MANUAL

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

ChannelPlus H17XL Series 2 User Operating Instructions

ServicePlus S17R Series 2 User Operating Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

Operating instructions. Universal timer switch display

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Ducasa Digital Programmer

Installation & Programming Manual. Please read before using this timer.

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

EN Wireless programmable thermostat

Battery Operated Controllers

Electronic 7 User Operating Instructions

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

TS-4000 Multifunction Thermostat Timer Switch User Manual

ST9100C User Guide. Features

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Instruction Manual Reizen Atomic Radio-Controlled USB-Charge Analog Talking Watch (USA-Euro Multi-Band) #704066

Radio-control universal dimmer (built-in type) Installation Instructions

Comfort System T-32-P Universal Thermostat. Operation Manual

BT Diverse Repeater. User Guide

[I] SELECTING ACTUAL TIME. )lf~ IMPORTANT: INSTALLER, Please leave this guide with the householder together with its Warranty card.

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

Master Time Clock MTC Users Manual

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

C-MAX. TSG200 Time signal generator TSG200. Time Signal Generator. Manual TSG200. RF Technology Specialist. Version. Revision. SPEC No.

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

Junior Max (JR Max ) Controller

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Programmable Room Thermostat With RF

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

User s Guide. ECx Features: Automatic Sprinkler System Timer

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

Schneider Industries SAS MTN5812../MTN MTN Time switch

Simply clever! The digital DIN-rail time switches by Grässlin

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

ST625TX Digital Room Thermostat

Programmable time switches Multiple function - daily/weekly

A digital version of this document is available to download and submit online at ADDRESS POST CODE

Digital Terrestrial Alignment & Installation Meter

User s Guide. ECx Features: Automatic Sprinkler System Timer

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Nixie Clock Type Quattro'

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

GreenParking. Commissioning guide. GreenParking

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

IQ250 (Mk.1, 2 & 3), IQ500 (Mk.1 & 2),

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

Additional Instructions for the Arlec Energy Cost Meter PC222

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

ZoneTouch V2 Zone Control System User Manual

USER & ENGINEER INSTRUCTION MANUAL

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

XTM72 Exerciser Timer Module

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

ORDER CODE: EQLED65 USER MANUAL

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

Light Commissioning Tool (CTTOOL) Operation Instructions

T Series LED Remote Controller

GAUGEMASTER PRODIGY EXPRESS

Dimming actuators GDA-4K KNX GDA-8K KNX

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

Figure 1: Device components

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

Operating Manual. Basic Control BC16. two-channel for eco moon

T Series LED Remote Controller

SceneStyle2 User Guide

Transcription:

24Hour/7Day Electronic Timeswitch Model: TG77 Installation & Operating Instructions

Increments programming steps and when held pressed for approximately 4 seconds initiates clock set mode Override to next programme change, also gives permanent ON/OFF and also suspends and reinstates programmes Tamper proof reset button (use pen or similar implement) Initiates countdown time period Initiates random delay to both start time and stop time of every programme 1 Output ON light Returns TG77 to operating mode with clock time displayed Decreases hours, minutes, days/day groups during programming and setting clock time Increases hours, minutes, days/day groups during programming and setting clock time 1. General The TG77 is an easy to programme electronic time controller with a large 24 hour display, offering both 24 hour and 7 day programming options. 20 ON/OFF programmes are available which can be made to operate over all seven days (24 hour operation), one of seven individual days and various combinations of days. Battery back up retains programmes and clock time in the event of mains failure and allows out of socket programming. The unit has the advanced feature of random delay to both start and finish of all programmes and also has a manually initiated Countdown time period of up to twenty four hours during which output is ON.

2 2. Features Plug-in control. 24 hour and 7 day programming options. 20 ON/OFF programmes operating over a wide choice of day groups and individual days. Manual override until the next programme change. Permanent ON or OFF facility. Large display. Battery back up retains current time of day and programme memory during loss of mains supply. Also allows programming out of socket. Manual start Countdown facility. ON/OFF programmes can be suspended from operation. Optional random delay to both start and finish of all programmes. Output ON indicator. Shortest switching time of 1 minute. Programme review. Repeats programmes week after week continuously. 3. Battery The unit has a factory fitted rechargeable battery to allow out of socket programming and to give clock operation and memory back-up during loss of mains supply. If the display is dim or not visible plug the TG77 into a live socket for 4 hours before resetting and programming. When not in use it is best to keep the TG77 plugged into a live socket to ensure the best possible battery life. 4. Reset (RST) The unit must be reset before programming for the first time or if the unit has been left out of a live socket for more than 150 hours. Press RST using a pointed object (e.g. a pencil). Display will show its full set of characters and clear to show: The colon between hours and minutes will flash and the seconds begin to advance.

3 5. Setting or Adjusting Clock Points to remember while setting time or programming:- (Seconds display is not shown on diagrams for sake of clarity.) The and buttons alter the days/day combinations, the hours, the minutes and programme numbers/on or OFF designation. The button also initiates the programme sequence for Countdown CTD mode. The button also initiates the ON/OFF programme sequence and achieves easy SUMMER/WINTER time change when pressed at the same time as the TIME button. The button increases the above value which is flashing and the button decreases it. If the particular value required is towards the end of a sequence (eg 52 for minutes) pressing the button can get to it quicker (from the 00 position). The or button can be held down to provide fast advance or reverse. The programming process is achieved by alternate use of the SET and or buttons. The setting sequence is as follows:- (example used is 10:52 WE being set from a reset condition (see section 4). If you wish to use the easy Summer/Winter time changeover described in section 13 please set the time to GMT (Winter time). Press the SET button for approximately 4 seconds and the day symbol will flash. Press until the display shows WE. Press until the hour digits reach 10.

Press until the minute digits reach 52 (note the use of the button being much quicker than the button in reaching 52). The TG77 is now in operation mode with the time display and colon flashing. 6. Programming Timed ON/OFF Mode 20 ON/OFF programmes are available to the user. Any number up to 20 can be programmed, unused programmes must be left blank ( : ) and not programmed with zeros. Each of the programmes can be assigned to work over the following days/day groups (shown in order of presentation on the TG77 programming screen):- 4 MO TU WE TH FR SA SU (24 hour operation) MO THROUGH TO SU (individual days) MO TU WE TH FR SA SU MO TU WE TH FR SA MO WE FR TU TH SA MO TU WE TH FR SA The programming sequence is as follows:- (example used is 12:10 ON 16:05 OFF MO TU WE) Press, display shows: Denotes flashing symbol(s).

Press, day(s) options change accordingly to above sequence (to retrace the options press ) when required option is reached (i.e. MO TU WE) then Press, hour digit(s) advance (to retrace hours press ) until 12 is reached then 5 Press, minute digits advance (to retrace minutes press ) until 10 is reached then Press, display shows: The OFF time and day(s) for the first programme can now be set. Press, until day(s) option reaches MO TU WE on the display

Press until hour digits reach 16 then Press until minute digits reach 05 then Press and display moves to the next ON time of the programme (2) in the sequence of 20 showing: 6 The TG77 now has the first programme locked into memory and is ready to receive additional programmes if required. When programming is complete press the TIME button to return to the operating mode. When programming additional programmes the choice of day or day group is always totally open. Note: Day/Days have to be set independently for each ON and OFF entry. This makes it easy to set programmes which traverse midnight or which carry on for more than one day. 7. Suspending A Programme From operating mode press repeatedly until the ON or OFF programme to be suspended is reached (button can be used to retrace steps if necessary). Press the button and display will reset to : then press the TIME button to return to operating mode. To reinstate programme again use to reach suspended programme and press to retrieve suspended programme then press the TIME button to return to the operating mode. ON and OFF halves of the same programme have to be suspended seperately.

8. Reviewing and Changing ON/OFF Programmes Press repeatedly until the ON or OFF programme requiring amendment is reached (button can be used to retrace steps if necessary). Press the SET button repeatedly until the day(s)/ hours/minutes are flashing then use the buttons to make the amendment. When this is complete press the TIME button to return to operating mode. 7 9. Adjusting Clock Time Press SET for approximately 4 seconds and the day symbol will flash. This can be changed using buttons as required. Further brief pressings of the SET button show the hour and minute settings flashing and these may be changed in the above way if required. Then press the SET button and the display will show the operational mode. 10. Countdown Mode This enables the TG77 to complete a timed ON period from a manually initiated start. The period can be from 1 second to 24 hours. The TG77 can be programmed as follows:- (example used 1 hour 10 minutes 30 seconds) Press, display shows: Press to set hours to 1

Press to set minutes to 10 Press to set seconds to 30 8 Now press CTD to start the countdown procedure. Output light will turn ON and the appliance plugged into the TG77 will be energised while the display counts down to zero when the appliance will be turned OFF. Before pressing CTD ensure the TG77 is plugged into a live socket and the appliance is switched ON. If the CTD button is not pressed within 10 seconds of the previous use of the SET button the display will revert to normal operation mode. To retrieve the setting press and then SET after which countdown can be started by pressing the CTD button. 11. Operating the TG77 in Timed ON/OFF Mode Ensure that the unit is in operating mode. Press the button until the left side of the display shows AUTO and either ON or OFF as appropriate for the programme(s) at that time of day and day of week. Then plug the TG77 into a live socket, plug the appliance to be controlled into the TG77 and ensure the appliance is switched ON. The TG77 will enact all programmes stored on a continuous basis. To override the unit at any time press the button twice. The display will change from AUTO OFF to AUTO ON or from AUTO ON to AUTO OFF and the override will last until the next programme change.

9 To go to a continuous ON or continuous OFF condition press the button repeatedly until either ON or OFF as appropriate is on the display without the AUTO symbol. 12. Random Delay of Programme Start and Finish By pressing the RND button the RND symbol appears in the top right of the display and a random delay to both start and finish of ON periods will result. The random delay varies anywhere between 2 and 32 minutes to give the impression that a standard timeswitch is not in use. 13. Summer/Winter Time Change-over By pressing the Time and buttons at the same time the time will advance 1 hour and the +1h symbol will appear over the second display. By pressing the buttons at the same time once more the symbol disappears and the time moves back 1 hour. To use this feature the TG77 needs to have the clock time set to GMT or Winter Time. 14. Change from 24 hour to AM/PM Format Press the Time button for around 3 seconds and both the Time display and all stored programmes will be changed from 24 hour to AM/PM format. Press the Time button again for around 3 seconds and both the Time display and all stored programmes will change back to 24 hour format. After pressing the RST button to reset the unit, it will always come up in 24 hour format.

10 15. Specifications Operating Voltage: 230V 50Hz. Switch Rating: 13A resistive, 2A inductive, 400W filament lamps. 100W fluorescent or low energy lighting. Operating Temperature: 0 C to 40 Battery: Factory fitted rechargeable. Provides up to 150 hours of clock operation and programme memory back up during mains failure. EC Directives: Conforms to latest directives. Not suitable for discharge (e.g. SON and Metal Halide) or LED lighting. 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture, within 1 year of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge. In the second and third years or any difficulty in the first please contact our helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.

For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com www.timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com 67-058-317 (Issue 2) Zerofour June 2015