SOTERIX MEDICAL MRI SOLUTION FOR tes and HD-tES

Similar documents
MRI SAFETY CONNECTION GUIDE

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Assembly instructions

Filters for Power Lines (Low Leakage Current)

Cable ISOBUS Active Termination

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

USER MANUAL. PT-571HDCP DVI Line Transmitter. PT-572HDCP+ DVI Line Receiver MODELS: P/N: Rev 8

ILDA Switch Automatic switching board for ILDA signals

DIN Connectors DIN06 E-03

EC Series Creativity Accessories Safety and Installation Guide

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Installation Evaluation Form

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

DX-10 tm Digital Interface User s Guide

HDBaseT HDMI Extender

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

WaterVue TV Installation & User Manual

MAXX BOX. MX102/202 Series. MAXX Box

Model 1421 Distribution Amplifier

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

Amphenol Telecom Solutions

Site Installation Model MP-8424

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

Active UTP Transceiver Hub Installation Guide

Series SK (2.92 mm) prec. submini. connectors

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

DIN EUROCARD CONNECTORS

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

Cold Shrink Straight Joint

DVI over Single CAT5 Series CV-117. DVI over Single CAT5 Direct Plug-in Extender. User Manual. Made in Taiwan

Active UTP Transceiver Hub

CAT5 VGA Extender. Mode 1 Mode 2

VGA & Audio over CAT5 Distribution Series

MT IN, 2-OUT CAT-5 TO VGA RECEIVER CARD FOR MULTI-TASKER USER S GUIDE

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Welcome to your. Wireless transmitter and receiver kit

2178-L/S Series Fiber Optic Splice Case with Gasket

TracVision R6DX Installation Guide

INSTALLATION INSTRUCTIONS FOR

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Extender w/ RS-232 and 2-way IR

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Model FS-HD4616VPS-36VDC. Features

1:8 CAT5 Distribution Amplifier

Site Installation Model MP-8433

12 Channel Media Splitter MS12 Mk2 User manual

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories

HDMI over Wireless Extender - 65 ft. (20 m) p

EXTENDER ELE8080. INSTALLATION Manual. Made in Taiwan

SLiC Fiber Aerial Closure System

Auxiliary states devices

Key Digital. Key Digital Exclusive. Video/Audio VGA/Component Smart Baluns with RS-232/IR Connection over CAT5/6/7 KD-VACWPRX KD-VACTX KD-VACRX

bmam connectors DIVIDER PAGE

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Cellular Signal Booster

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Installing the P80 Console Media Adapter

Fiber Optic Splice Closure GPJ Instruction Manual

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Preventing Fieldbus Physical Layer Problems

Medium Box for Cable Termination

C 303W-RF Tri-element Array Microphone Instructions

This Errata Sheet contains corrections or changes made after the publication of this manual.

Assembly Instructions

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

LEON AUDIO. Speaker s Timer. mk3. A versatile timer for use at conferences to indicate the time remaining for a speech.

1.1 Introduction Getting Connected Guide - Wireless Setting up a Wireless Network Getting Connected Guide - Wired...

SMA - 50 Ohm Connectors

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Check our knowledge base at

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

3M Distribution Box (DDB)

VGA, Audio & RS-232 Serial with IR Pass-Thru over Single CAT5 /RJ45 Extender Kit

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

VNS2200 Amplifier & Controller Installation Guide

KD-VP800 RGBHV-to-Component Digital Video Scaler & Video Adapter

NewScope-7A Operating Manual

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Processing Specification MiniBridge IDC

EXT-UHD600-1SC Version A1

HDMI over Wireless Extender p

Model Camera System (CCTV) User Manual

MR Confon Starter f MKII+ User Guide Version R01 June 2017

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

LINK POWER IR RX IR TX 12V 2A. HDMI Out EL-4KHDBT-RX-40-IR. HDBT In LINK EL-4KHDBT-RX-40-IR. User Manual

BNC-Panel-16-TTL User Manual

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

User Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

Transcription:

SOTERIX MEDICAL MRI SOLUTION FOR tes and HD-tES Compatible with standard EPI sequences. Suitable for upto 3T systems. Compatible with all Soterix Medical 1x1 and High-Definition (HD) stimulation systems. USER GUIDE

SET-UP (SINGLE-CHANNEL) MRI CHAMBER MRI CONTROL ROOM 1 2 4 5 6 PATCH PANEL 1 2 3 4 5 6 Carbon Composition Cables 8M MRI Cable MRI Filter 2M MRI Cable Current Limiting Cables 1x1 Connecting Cables Page 2 of 8

SET-UP (SINGLE-CHANNEL) MRI CHAMBER MRI CONTROL ROOM 1 2 4 5 6 PATCH PANEL Page 3 of 8

SET-UP (MULTI-CHANNEL) MRI CHAMBER MRI CONTROL ROOM 1 2 4 PATCH PANEL 1 2 3 4 Carbon Composition Cables 8M MRI Cable MRI Filter 2M MRI Cable Page 4 of 8

SET-UP (MULTI-CHANNEL) MRI CHAMBER MRI CONTROL ROOM 1 2 4 5 6 PATCH PANEL Page 5 of 8

PATCH PANEL CONNECTOR CONFIGURATIONS 1) If no patch panel connector exists in the patch panel, then it is recommended that the MRIRFIF be installed directly on the patch panel. The MRIRFIF is symmetrical so orientation direction is not important, however it is very important that it be installed on the CONTROL room side of the patch panel. This is critical because the MRIRFIF incorporates ferromagnetic elements. The MRIRFIF performs an internal pin swap of pins 1 through 5; pins 6 through 9 are unused by MRIRFIF (see Table below). The MRIRFIF mounts to the patch panel via the included L-bracket support. Prior to mounting the support bracket and MRIRFIF, a cutout in the panel is required to expose one female connector of the MRIRFIF to the MRI Chamber Room. The panel cutout should only be large enough to expose the female connector in order to maintain a uniform EMI seal between the MRIRFIF EMI gasket and the patch panel. Two mounting holes to bolt the L-bracket to the patch panel are also required. See Figures 1, 3, 4 (Installation method A) for details 2) If a patch panel connector exists, then the MRIRFIF should be connected to the CONTROL room side of the patch panel connector. In this case, the chamber room side of the patch panel connector must be a 9 pin female DSUB and the control room side of the patch panel connector must be a 9 pin male DSUB. In this situation, verify that pins 1 through 5 are mapped straight through on the M/F patch panel connector. The MRIRFIF plugs directly into the existing patch panel connector (Male 9 pin DSUB) and is supported via the included L-bracket. Two mounting holes are also required in the patch panel to bolt the L-bracket to the panel. Also, its important to perform a dielectric test to ensure that sufficient electrical isolation (typically 1500 V DC or greater) is present between the existing patch connector pins and the mains ground as established on the patch panel itself. See Figures 2, 3, 4 (Installation method B) for details DSUB 9 female Control Room side 1 2 3 4 5 Chamber Room side 5 4 3 2 1 Table: MRIRFIF s symmetrical construction results in pin swap for pins 1,2,3,4,5 Page 6 of 8

PATCH PANEL CONNECTOR CONFIGURATIONS CHAMBER ROOM CONTROL ROOM CHAMBER ROOM CONTROL ROOM DSUB9f L-bracket EMI Gasket DSUB9f Existing patch panel connector DSUB9f DSUB9m DSUB9f MECMRI-1 MECMRI-4 MECMRI-1 MECMRI-4 MRIRFIF installed as patch panel connector MRIRFIF (supported via L-bracket) Figure 1: Cabling sequence for patch panels with no existing connectors. Figure 2: Cabling sequence using existing patch panel connector. Panel cutout for 9 pin DSUB MRIRFIF or existing DSUB 9 Female connector EMI Gasket Existing patch panel connector L-bracket mounting holes Panel cutout for 9 pin DSUB MRIRFIF or existing DSUB 9 Female Installation A Slide MRIRFIF forward to press connector gasket to patch panel Installation B Slide MRIRFIF back to permit attachment to existing patch panel connector. Figure 3: Control and Chamber room view of cutout to support MRIRFIF mounting. Figure 4: Side view of MRIRFIF installation methods to patch panel. Page 7 of 8

WARNINGS Implement patch panel filtering (between the Control Room and Chamber Room) as per instructions provided. Implementation should be performed by MRI personnel specialized in shielding systems. Correct installation of MRIRFIF is required to maintain MRI imaging performance and to create a safe operating environment. It is important to install MRIRFIF on the CONTROL room side of the patch panel. This is critical because the MRIRFIF incorporates ferromagnetic elements. It is important to note that the MRI Chamber Room is robustly EMI shielded. This shielding is very important to maintain signal integrity in the NMR image data. This EMI shielding will be compromised if un-filtered electrical cabling is routed between the MRI Control Room and the MRI Chamber Room. Accordingly, considerable attention should be directed to patch panel connector configurations and associated signal routing and filtering. Phantom testing is recommended before performing any electrical stimulation protocols in fmri or MRI. The cables (lead wires) should not be coiled or twisted and should run straight. Page 8of 8