SMC 3000 Series Master Clock Installation Manual (V2) Table of Contents

Similar documents
SMC 2000 Series Master Clock Installation Manual (V2) Table of Contents

TALKBACK INTERCOM SYSTEM V-2927 CLOCK CONTROL CARD FOR THE V-2924A

STR 2000 Series Transceiver Programming Manual (V2) Table of Contents

SBL /SBLG Series Wireless Clock

SAPLING MASTER CLOCKS

SAPLING WIRED SYSTEM

TALKBACK INTERCOM SYSTEM V-2927 CLOCK CONTROL CARD FOR THE V-2924A

SAL Series Wireless Clock (V1)

Valcom Wired Digital Clock

TALKBACK INTERCOM SYSTEM VC-2927 CLOCK CONTROL CARD FOR THE VC-24

Sapling Wired System. Synchronized Clock Systems

Sapling Wired System. The Sapling Company, Inc Republic Road Huntingdon Valley, PA P F

Installation and Operation Manual. YMP Series Signal Programmer

NTP 8000 Series Master Clock

Master Time Clock MTC Users Manual

NTP 7000 Series Master Clock

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Sapling Synchronous Communication Clock System Section Master Guide Specification Page 1 October 2013

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

SBL Series Wireless Clock Installation Manual (V2) Table of Contents

Installation Instructions

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Sapling Wireless TalkBack Technology Clock System Section Master Guide Specification Page 1 October 2013

DIGITAL SWITCHERS 2100 SERIES

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

Sapling Wireless Clock System Section Master Guide Specification Page 1 October 2013

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

Sapling IP Clock System Section Master Guide Specification Page 1 October 2013

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

HS-509 VIBRATION TRIP MODULE

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

US Rev. E, Copyright 1 September 2008 CAUTION:

TRAINING KITS ON DIGITAL ELECTRONIC EXPERIMENTS. Verify Truth table for TTL IC s AND, NOT, & NAND GATES

DX-10 tm Digital Interface User s Guide

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

BE3-GPR GENERATOR PROTECTIVE RELAY

Computer Systems Architecture

BUSES IN COMPUTER ARCHITECTURE

Electrical connection

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

Master Clock Controller. User Guide. pyramidtimesystems.com

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

DCP100 Digital Control Programmer Specifications

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

PRINCIPLES AND APPLICATIONS

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Automated Local Loop Test System

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

EA350. Generator Automatic Voltage Regulator Operation Manual

Chapter 5 Sequential Circuits

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

NI-DAQmx Device Considerations

INSTRUCTION MANUAL. J800 Weld Controller. 3/25/2018 Revision

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

Fig. 1. The Front Panel (Graphical User Interface)

AD9884A Evaluation Kit Documentation

Model R177M and R177S Baseband Switch

Contactors and Contactor Assemblies

Wall-/Pipe-Mount Level Indicator

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

MultiMode FOMs -ST and -SMA

Multifunction devices

multi-function meters

Copyright 2011 by Enoch Hwang, Ph.D. and Global Specialties. All rights reserved. Printed in Taiwan.

TeamWork Kits Installation Guide

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

210E - 210ECL ECL ECL

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Combinational vs Sequential

Summit Systems Sound Board Modification

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Sequential Digital Design. Laboratory Manual. Experiment #3. Flip Flop Storage Elements

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

ex 800 Series ematrix System

with Simulated Outputs Description Applications Features

Overview: Specifications: Installation Instructions:

Installation and Operation Manual

Type MG-6 Auxiliary Relay Class 1E

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Adder 882i Intercom/Data Multiplexer

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Operating instructions Electronic preset counter Type series 717

DA8-T DA8-T MANUAL

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Instruction Manual Model # Block Upconverter

Transcription:

MOUNTING Surface Mounting Diagram.. Page 2 Rack Mounting Diagram.. Page 3 BOARD LAYOUT Board Layout. Page 4 INTERFACING Interfacing With Other Sapling Master Clocks. Page 5 SYNCHRONOUS CORRECTION CODES Synchronous Correction Code Chart..... Page 6 WIRING DIAGRAMS Wiring Diagrams Pages 7-13 INTERFACING Interfacing With Other Systems Pages 14-17 FREQUENTLY ASKED QUESTIONS SMC 3000 Frequently Asked Questions Page 18 TROUBLESHOOTING Table of Contents SMC 3000 Troubleshooting.. Page 19 Page 1

Surface Mounting Diagram Page 2

Rack Mounting Diagram Page 3

Board Layout Page 4

Interfacing Between Master Clocks Page 5

Synchronous Protocol Information Protocol Type Correction Code Hourly Correction Time Hourly Correction Duration Daily Correction Time Daily Correction Duration 59 minute correction Simplex 2310-92XX 57 and 77 series IBM 57, 62, 77, 82 and 87 series Cincinnati D10 and D12 Latham SS12 types Edwards 01 Dukane 24SS series 006 xx:57:54 Will correct the minutes and seconds. 8 seconds 05:57:54 17:57:53 Will correct hours, minutes, and seconds. 14 seconds Dukane 24030,24023,24050, 24060 and 24010 types National Time & Rauland Rauland Analog 2460 series National 010-NNE-SRAX, 010-NNE-SRAXLV, 023-NNE-SRAX, 023-NNE-SRAXLV, 030-NNE-SRAX, 030-NNE-SRAXLV, 060-12E-SRAX, 060-12E-SRAXLV xx:00:00 Will correct 001 or 002 the minutes 25 seconds and seconds. 06:00:00 18:00:00 Will correct hours, minutes, and seconds. 001 = 25 seconds on, 35 seconds off every minute for 24 minutes. 002 = 24 minute closure from 6:00:25 to 6:24:25 AM & PM Stromberg E3109 and WS310 National, 010-NNE-SR, 010-NNE-SRLV 023-NNE-SR, 023-NNE-SRLV 030-NNE-SR 030-NNE-SRLV 060-12E-SR 060-12E-SRLV Dukane 24BF209, 24BF212 707-8 and 707-9 types 005 xx:56:05 003 10 seconds Will correct the minutes and seconds. 11:56:00 23:56:00 Will correct hours, minutes, and seconds. 45 seconds 020 xx:00:00 25 seconds N/A N/A xx:57:03 Will correct the minutes and seconds. xx:58:05 57 seconds 5:59:03 17:59:03 Will correct for hours, minutes, and seconds. 57 seconds on, 63 seconds off 11 times from 5:59:03 to 6:20:00 58 minute correction Honeywell ST402, 403, 404, 410, 411, 412, 413, 802, 803, 804, 810, 811, 812 & 813 Faraday 1310, 1311, 1320, & 1321 Cincinnati D8 Standard/Faraday 2310 & 2331 007 xx:58:05 Will correct the minutes and seconds. 55 seconds 5:05:00 17:05:00 65 seconds on, 25 seconds off 12 times from 5:05:00 to 5:22:35 Page 6

Page 7

Page 8

Page 9

Page 10

Page 11

Page 12

Page 13

Interfacing With Other Systems Slave Input Mode Address 070: Slave input mode (Please see diagrams below for wiring information and instructions) 000 Off 001 Midnight Reset / Once a Day Pulse Address 72 = Hour, Address 73 = Minute, Address 74 = Second 003 59 minute synchronous 004 58 minute synchronous 005 National Time and Rauland analog 006 Rauland Systems digital Address 075: Impulse clock mode With the clock powered down, switch jumpers S2 and S4 on the relay board to S1 and S3. Power up the clock with the 50 watt power supply installed (part # SMC-000-010-1). Pins 25 and 26 will power up the impulse clocks. The time on the slave clock has to be entered in programming so the master clock will send out the correct amount of pulses to correct the clock. Once you have entered all required information, press the <NO/CANCEL> key to exit programming mode. MIDNIGHT RESET: Applying a minimum of two-second pulse will bring the master clock to the correct time. Instructions: 1. Set address 070 to 001 2. Input the exact time (in hour, minute, second) that the clock should reset to when it receives the correction pulse. This data is entered into Addresses 072, 073 and 074 as shown in diagram above. 3. Connect input as shown in the diagram 4. Apply power to the clock. Page 14

Interfacing With Other Systems 59 MINUTE CORRECTION 110 VAC/24 VAC 60 Hz is used to run the clock normally. Applying an eight (8) second reset signal from 57 minutes and 54 seconds will cause an hourly correction. Applying a fourteen (14) second reset signal from 5:57:54 will cause a daily correction. Instructions: 1. Set address 070 to 003 2. Connect input as shown in the diagram. 3. Apply power to the clock. 58 MINUTE CORRECTION 110 VAC/24 VAC 60 Hz is used to run the clock normally. Applying a 55 second reset signal from 58 minutes and 05 seconds will cause an hourly correction. Applying a 55 second reset signal when hours equal 05 or 17 and minutes equal 03, 07, 11, 15, 19, 23, 31, 35, 43 or 47 and seconds equals 05 will cause a daily correction. Instructions: 1. Set address 070 to 004 2. Connect input as shown in the diagram. 3. Apply power to the clock. Page 15

Synchronous Protocol Information NATIONAL TIME and RAULAND CORRECTION (Analog Clocks) 110 VAC/24 VAC 60 Hz is used to run the clock normally. Applying a 25 second reset signal when minutes equal 00 and seconds equal 00 will cause an hourly correction. Applying a 24 minute reset signal when hours equal 06 or 18 and minutes equal 00 and seconds equals 25 will cause a daily correction. Instructions: 1. Set address 070 to 005 2. Connect input as shown in the diagram. 3. Apply power to the clock. RAULAND SYSTEMS CORRECTION (Digital Output) Applying a half second pulse for every minute to the Dig. Line will bring the clock to the correct time. The clock will jump to the correct time at the end of the correction pulse. Instructions: 1. Set address 070 to 006 2. Connect input as shown in the diagram. 3. Apply power to the clock. Page 16

RS232 Interfacing Fire Alarm System Interfacing This function can only be used when running a digital clock system (either SBD 1000 or SBD 2000). Instructions: 1. Connect input as shown in the diagram. 2. Apply power to the clock. Page 17

What systems can I run off of the SMC 3000 Series Master Clock? The SMC 3000 Series master clock can run 59 minute correction, 58 minute correction, National Time and Rauland, 2 and 3 wire digital communication (with optional auxiliary power supply installed), and Sapling RS485 systems. Can I interface the SMC 3000 with a computer? Yes, through the RS232 output on the master clock. The SMC 3000 also has software called MEDITOR which allows the user to enter, edit, and delete schedules and schedule changes through a Windows based program. How many events can I schedule into the master clock? There can be up to 800 events scheduled in the master clock. I have to have a bell system in the school. How many relays are available in the SMC 3000 Series master clock? There are four (4) relays standard with the master clock. The SMC 3000 master clock can utilize up to twelve (12) relays total. What voltage can I use to power the SMC 3000 Master Clock? The SMC 3000 master clock can be powered using 110 VAC/60 Hz or 220 VAC/50 Hz. Will the master clock lose all of my settings if power is removed? No, the SMC 3000 has a non-volatile EEPROM that ensures that the information stored will not be lost. Is there anyway I can test to see if a relay is working? Yes, through BIT testing, every aspect of the master clock can be tested to make sure everything is running optimally. For more information on BIT testing, please refer to the SMC 3000 programming manual. Does the SMC 3000 have built-in bells? Frequently Asked Question No. The SMC 3000 does not contain any bells. It provides the relay closures for bell systems. Bells or tone generators must be purchased through a third party. Page 18

Troubleshooting What should I do if the master clock is not powering up? Measure the voltage between pins one (1) & three (3). The voltmeter should read 85-135 VAC between the hot and the neutral. I m trying to control my SMC 3000 by using a Rauland master clock, but it doesn t seem to be working. What should I do? Make sure the SMC 3000 is wired correctly to make sure it is capable of receiving the input. Also, make sure Address 070 is set to the right protocol. My synchronous clock system is not correcting. What should I do? Make sure the right correction code is inputted into the master clock circuit. Please refer to page 6 for details. My 2 wire system doesn t seem to be working. How can I test the signal of the 2 wire digital communication circuit? First, make sure the auxiliary power supply was installed (part number SMC-000-010-1). If the power supply is correctly installed, then put the voltmeter on DC voltage. Measure between pins 25 and 26 and verify that you have a pulsating 24 volts. If you do not have voltage there, contact Sapling technical support. I m interfacing the master clock with the GPS receiver. The master clock doesn t seem to correct. What should I do? Make sure the polarity for the RS485 is correct coming from the GPS. If the polarity is reversed, the master clock will not correct. The relay isn t closing for my bell system. How do I know if it s working? The SMC 3000 has a self-testing feature called BIT testing. This will test all aspects of the master clock. Enter BIT testing and test the relay. For more information on how to enter BIT testing, please refer to the SMC 3000 programming manual. Page 19