CENTRALIZED CONTLROL WEEKLY TIMER

Similar documents
Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ST9100C User Guide. Features

7 Day Digital Programmer 3 Channel Surface Mount

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

TDDFM14 OWNER S MANUAL

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

Programmable Video Signal Generator VG-880. Instruction Manual. Ver 1.10

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

The Parts of The System

Service & Equipment Charges List

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Conference Speaker Timing System. Operating Instruction Manual

16 Amp Electronic 24 Hour/7 Day Time Controller

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

Overview: Specifications: Installation Instructions:

Philips LightMaster. KNX Timeclock Installation and Operation Manual

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

PLUSTV 1680ex USER S MANUAL

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

SSPT724A Timer Quick Start Guide

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

User s Guide for the Digital Video Recorder

61CM CORDLESS REMOTE COLOUR TELEVISION MODEL: Type Tested Electrical Safety AS/NZS 3250 Lic 4165 Standards Australia APP No: N16712

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Part names (continued) Remote control

I.Safety Prevention Measures

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Aspect 2 Circuit Digital Scene Control

Installation & Programming Manual. Please read before using this timer.

Transponder Reader TR22A01KNX TR22A11KNX. Product Handbook

GAUGEMASTER PRODIGY EXPRESS

UTH-170 Installation and Manual

7 Day Digital Programmer

and Re:system MR-Slave Module Dominating Entertainment. Revox of Switzerland.

PQ-Box 100 Quick Start Instructions

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

TRF STEP-DOWN TRANSFORMER USER MANUAL

Behind this door is a slot for a future smart card. No smart card is included with this receiver.

MRX1 1. Getting to know your MRX1 wireless controller

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Standard Digital Terminal High-Definition Digital Terminal. User Guide

User manual. Goodmans Product Information:

TFT-LCD TV USER MANUAL W102T READ CAREFULLY BEFORE OPERATION W102T

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

V26 Chassis V26+ Chassis V26++ Chassis WD WD WD WD WD WD-62825

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Pixel LED SPI Digital Controller

LED Programmable Interval Timer Owner's Handbook

Safety FIND THE FEED CABLE IN YOUR ELECTRICITY METER (UK)

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

QUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL

Master Time Clock MTC Users Manual

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

Basic Information Before Use. Display on LCD Screen. Distinction by. Patterns Recognition. Use of Applied Functions. Changing Set Value

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

AT450SAW Programmable Selective Amplifier

MP-7424 Football Scoreboard with MP5000 Console

The new name-based recording feature has two key benefits:

Luxus A / SR-1 Electriscreen

OPERATING INSTRUCTIONS

Digital Video Recorder

DVI Converters: Installation & Operation Guide BDV BLACK DIAMOND VIDEO

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

Order #XXXXX - ECO x10 Inline Display. Setups. 10 Plan View

ø 4 mm 3 Image 40 mm Ø 4 mm Ø 4 mm

GAUGEMASTER PRODIGY ADVANCE --- WIRELESS ---

Preface... Specification...14

Quick Setup Guide. Rear Panel / Side Panel Jacks LN37A530P1F/LN40A530P1F/ LN46A530P1F/LN52A530P1F. Video Input Performance Comparison

Sample BD Tech Concepts LLC

7 Day Digital Light Switch with Optional Dusk Start

KNX Dimmer RGBW - User Manual

Standard RS232 RS ma

OPERATING INSTRUCTIONS IN BRIEF

M1020 Programmable Limit Switch (PLS)

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

2 Hour Electronic Boost Timer

Dimming actuators GDA-4K KNX GDA-8K KNX

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Programmable Room Thermostat With RF

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Installation and Operation Manual. YMP Series Signal Programmer

192 Channel DMX Controller

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

<'E&, > WZKϮϰs USER MANUAL

video door entry system - installation instructions

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

PSC300 Operation Manual

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

DSR-3000P. Digital Video Recorder. Manual for Remote Operation by Network Connection. Bedienungsanleitung fürdie Fernbedienung über ein Netzwerk

Transcription:

CENTRALIZED CONTLROL & WEEKLY TIMER

Please read this manual carefully before using this product

Content 1. Installation Method 2 2. Notice 4 3. Joint 4 3.1 Power Joint 3.2 Communication Joint 4 4 4. Structure Diagram 5 5. Operation Guidance 9 5.1 Single/Group Control Setting 9 5.2 On/Off Setting 11 5.3 Timer Setting 12 5.4 Consult On/Off and Timer 5.5 Time Setting 5.6 Key-lock Setting 18 19 20 1

1. Installation Method 1. First, select an installation location, leave a slot according to dimension of power switch. The slot is for assembly power switch. 2. Connect the power cords of weekly timer and power switch by following the figure shown below, and make the power cord of power switch and twisted-wire with crystal joint through electric box <3>. 3. Fix power box of switch <2> and base plate of weekly timer onto power box <3> with bolts. 4. Cover the box cover of weekly timer. Notice: Pay special notice to the direction of base plate of weekly timer when installing it. The side with 2 gaps should be downward, or the panel of manual contro l cannot be installed correctly. Fig.1 Concealed wire 2

Power cord of power switch (Brown one is live wire, blue one is neutral wire.) Note:For prevent disturbance power cord and signal wire should be wired in different wire grooves. Twisted-wire with crystal joint (Connect with telephone wire base) Power cord of weekly timer Fig.2 Installation sketch No. Names 1 Bolt 2 Power switch 3 Power box 4 Wall 5 Weekly timer 6 Base plate of weekly timer 3

2. Notice 1.Ensure the specification of power for weekly timer, or the weekly timer may work abnormally, or even damage the weekly timer. 2. Ensure the correct joint of communication wire, or there will be communication error. 3. Don t place the weekly timer to where there is water leakage or direct sunshine. 4. Prevent knocking, throwing, or breaking down then assembly the weekly timer too frequently. 5. The time for the first electrify of weekly timer is about 10s. 6. Under the circumstance of malfunction (such as burning odor is smelled), turn off the power of weekly timer immediately. 3. Joint 3.1 Power Joint As shown CN2 in fig.3, power can adopt the power switch offered by our company, but can also adopt other power but with the same joint, and input power specification should be 12V, 400mA. 3.2 Communication Joint As shown CN1 in fig.3, A and B are for connecting manual control. When connecting with communication wire, communication terminal A at weekly timer should correspond to terminal A at manual control, terminal B should correspond to terminal B. 4

4. Structure Diagram Fig.3 Joint sketch Structure of weekly timer is as shown in fig.4: Fig.4. 5

No. Instruction No. Instruction 1 Displays unit s no. 11 Displays off control 2 Displays group control 12 Display present time in week 3 Displays single control Displays present time in 13 Hr:Min 4 Displays timer time in Confirm 14 week. 5 Displays timer 15 Increment 6 Displays timer state 16 Decrement 7 Displays timer period 17 Cancel/delete 8 Displays timer on time 18 Single control/group control 9 Displays timer off time 19 Timer/time 10 Displays on control 20 On/Off 6

Display of default page (fig.5): Fig.5. 1) If the unit is under controlled state, the no. of corresponding unit would be displayed. 2) If the unit is in on state, the no. of corresponding unit would contains an underline; if the unit is in off state, the no. of unit will not have underline. 3) If there is only one unit under controlled state, and the present time is be in certain timer period, then that timer period will be displayed, otherwise, there will be no timer displayed. E.g.: In fig.5, the present time is 18:59 at Tuesday, unit 2 is under controlled state and off state, and the setting of timer period 3 at Tuesday for unit 2 is on time at 18:00 off time at 20:00, it means present time is right in that set time period, thus, timer period if displayed. 7

Note: 1) Differences between long-press and short-press mentioned below: press time for long-press is not shorter than 5s, and the time for short-press is shorter than 5s. 2) Corresponding unit no. of the selected unit contains an underline, and the corresponding unit no. of the not selected unit contains no underline. 3) The set unit on time and off time cannot be the same and unit on time should be smaller than unit off time, otherwise the setting is invalid and remaining previous setting. 4) If there is common part between 2 time periods of a unit in one day, take unit. 5) Minute part for timer can only by increased or decreased by every 10 minutes, all time setting is in 24 hours system, and all settings can only be in one day. 6) To the setting in the same period in the same for the same unit, if setting is refreshed, unit conduct present setting; if there is previous setting but no present setting, then the previous one can be saved. 8

5. Operation Guidance 5.1 Single/group control setting 1. Single control setting (fig.6) Fig.6. 1) Under default page, short-press single/group to enter single control setting. SINGLE displayed and all unit numbers be displayed. 2) Press dec or inc to select the unit that need to be set. 3) Short-press single/group then select unit, when single/group is short-pressed again, corresponding number of the previous selected unit will be canceled. The corresponding number for selected unit contains underline, and the not selected unit contains no underline. 4) If a certain unit is selected in process 3), press dec or inc to delete. 5) After pressing enter, single control setting works, and the page displays corresponding number for the selected unit. There is no underline with the selected unit. The selected unit can enter on/off setting and timer setting. 6) Short-press cancel/delete can back to default interface, and single control setting doesn t words. 9

2. Group control setting (fig.7) Fig.7. 1) Under default page, long-press single/delete to enter group control setting. Group is displayed and numbers for all unit be displayed. 2) Press dec or inc and selected the unit that needs setting. 3) Short-press single/delete and select unit, when short-press single/delete again can delete the previous selected unit. There is an underline at the number of selected unit; and no underline at the number of not selected unit. 4) When a certain unit is selected in process 3), press dec or inc would not delete the selected unit in process 3). 5) After pressed enter, group control setting works and page displays the number of the selected unit. There will be no underline at the selected unit, but the selected unit can enter on/off setting and timer setting. 6) Short-press cancel/delete can back to default page, and group control setting doesn t work. 10

5.2 On/Off Setting (fig.8) Note: 1. This setting can only be conducted when single/group setting is well set. 2. On/off setting can be conducted with timer setting. Fig. 8. 1) Press On/Off to turn on the unit; repress On/Off to turn off. Under single control, only one unit can be turned on/off, under group control, then the several selected units can be turned on/off. On is displayed when turn on the unit and Off is displayed when turn off the unit. 2) Press enter to validate on/off and back to default page; short-press cancel/delete to back to default page and on/off setting doesn t work. 11

5.3 Timer Setting Note: 1. Timer setting can only be conducted when single/group control has been set well. 2. Timer setting can go with on/off setting. 3. Weekly timer needs time to save and process data, no button can work during that period. Fig.9. 1) Short-press timer/time to enter timer setting. At this time, TIMING and ON displayed and blink, timer is in valid state (fig.9). 12

Fig.10. 2) When canceling timer setting to the selected unit, long-press cancel/delete after process 1), TIMING and OFF blinks, then timer is in invalidate state. At this time long-press cancel/delete can switch timer between validate and invalidate state. Only under timer validate state can set timer. Short-press cancel/delete can back to default page. Press enter when timer is invalidated can cancel all timers for the selected unit in a week (fig.10). 13

Fig.11. 3) When timer is validate, short-press timer/time to enter timer week setting. Press dec or inc can select a certain day in one week. Short-press cancel/delete back to process 2) (fig.11). 14

Fig.12. 4) Short-press timer/time again to begin setting timer period of timer. Press dec or inc can select a certain time period in a certain day in a week. Short-press cancel/delete back to process 3) (fig.12). 5) Short-press timer/time again to begin setting timer on and timer off. Press dec or inc can select specific value, short-press timer/time can move from the hr. part at timer on time to Min. part of timer off time. Short-press cancel/delete back to process 4). When hr. parts of both timer on time and timer off time been set, the setting process of this time period completed. Note: Only when short-pressing cancel/delete to back to process 4) and both hr. and min parts of turn on time and turn off time been set, the function become validate. That is, short-press timer/time till min. part of turn off time doesn t blink. 15

Fig.13 6) To cancel timer at a certain day, long-press cancel/delete in process 3) and TIMING OFF displayed. It is available to select other days to conduct timer setting (fig.13). E.g.: In fig.13, timer setting at Monday for unit 1 and unit 9 is deleted. 16

Fig.14. 7) To cancel timer of a certain time period in a certain day, long-press cancel/delete in process 4) and TIMING OFF displayed. But timer setting can be conducted at other time period at that day (fig.14). E.g.: In fig.14, timer setting for the 3 rd time period in Thursday for unit 1 and unit 9 are deleted. 8) No matter when enter is pressed during timer process, timer is validated and back to default page. 17

5.4 Check Unit On/Off and Timer (fig.15) Fig.15. 1) Under default page, number of the controlled unit is displayed. If there is an underline under the unit, means the unit is under on state, otherwise it is in off state. shoot-press timer/time to begin consulting unit timer time, and numbers for all units will be displayed. 2) Press dec or inc to select unit and the number of corresponding unit blinks. Short-press cancel/delete can back to default page. 3) Short-press timer/time then dec or inc to select a certain day in a week. At this time, timer week of selected unit number is displayed. Short-press cancel/delete can back to process 2). 4) Short-press timer/time then dec or inc can select certain time period at that day. Timer time period and the timer at that time period are displayed at that time. Press cancel/delete can back to process 3). 18

5.5 Time Setting (fig.16) Fig.16. 1) Long-press timer/time under default page can begin time setting, and the minute part for time part blinks. 2) Press dec or inc to select the minute part of set time. Short-press timer/time then hour part blinks. Press dec or inc can set hour part time. Short-press timer/time then week part of timer blinks. Press dec or inc can set week part of time. 3) No matter when enter is press, set time validate and back to default page; short-press cancel/delete can back to default page, and time setting invalidate. 19

5.6 Key-lock Setting (fig.17) Fig.17. 1) Long press " cancel/delete " button to enter wire controller key-lock operation. 2) "CC" will be displayed when the central controller is enter the key-lock function status. All the unit number will be displayed and the smallest unit number will be blinked. Short press " enter " button to activate the key-lock function and press it again to release this function. An underline will be displayed at the key-locked unit. 3) Short press " cancel/delete " to leave the key-lock function status. E.g.:In fig 17, unit 1 is key-locked. The other units are not activated the key-lock function. 20